• Title/Summary/Keyword: Corrosion Defect

Search Result 157, Processing Time 0.031 seconds

Durability and Crack Control of Concrete Using Fluosilicates Based Composite (규불화염계 복합 조성물을 혼입한 콘크리트의 균열제어 및 내구성)

  • Yun, Hyun-Do;Yang, Il-Seung;Kim, Do-Su;Khil, Bae-Su;Han, Seung-Gu
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.1 s.91
    • /
    • pp.57-64
    • /
    • 2006
  • The crack presented in concrete structures causes a structural defect, the durability decrease, and external damages etc. Therefore, it is necessary to improve durability through the effort to control the crack. Fluosilicic acid($H_2SiF_6$) is recovered as aqueous solution which absorbs $SiF_4$ produced from the manufacturing of industrial-graded $H_3PO_4$ or HF. Generally, fluosilicates prepared by the reaction between $H_2SiF_6$ and metal salts. Addition of fluosilicates to cement endows odd properties through unique chemical reaction with the fresh and hardened cement. Mix proportions for experiment were modulated at 0.45 of water to cement ratio and $0.0{\sim}2.0%$ of adding ratio of fluosilicate salt based inorganic compound. To evaluate correlation of concrete strength and adding ratio of fluosilicate salt based inorganic compound, the tests were performed about design strength(21, 24, 27 MPa) with 0.5% of adding ratio of fluosilicate salt based inorganic compound. Applications of fluosilicate salt based inorganic compound to reduce cracks resulted from plastic and drying shrinkage, to improve durability are presented in this paper. Durability was evaluated as neutralization, chloride ion penetration depth, freezing thawing resistant tests and weight loss according reinforcement corrosion. It is ascertained that the concrete added fluosilicate salt based inorganic compound showed m ability to reduce the total area and maximum crack width significantly as compared non-added concrete. In addition, the durability of concrete improved because of resistance to crack and watertightness by packing role of fluosilicate salt based inorganic compound obtained and pozzolanic reaction of soluble $SiO_2$ than non-added concrete.

Study on the Micro Crack Detection in Joints by Using Ultrasound Infrared Thermography (초음파 적외선 열화상을 이용한 접합부의 미세균열 검출 연구)

  • Park, Hee-Sang;Choi, Man-Yong;Park, Jeong-Hak;Lee, Seung-Seok;Huh, Yong-Hak;Lee, Bo-Young;Kim, Jae-Seong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.2
    • /
    • pp.162-169
    • /
    • 2012
  • This study detected SCC defects of dissimilar metal welded(STS304 and SA106 Gr. b) pipes using the ultrasonic infrared thermography method and the lock-in image treatment method among infrared thermography method. The infrared excitement equipment has 250 Watt of output and 20 kHz of frequency. By using the ultrasound infrared thermography method, the internal defects of dissimilar metal weld joints of pipes used at nuclear power plants could get detected. By an actual PT test, it was observed that the cracks inside the pipe existed not as a single crack but rather as a multiple cracks within a certain area and generated a hot spot image of a broad area on the thermography image. In addition, UT technology could not easily defects detected by the width of $10\;{\mu}m$ fine hair cracks. but, ultrasound infrared thermography technique was defect detected.

Evaluation of Weld Defects in Stainless Steel 316L Pipe Using Guided Wave (스테인레스 316L강의 배관용접결함에 대한 유도초음파 특성 평가)

  • Lee, Jin-Kyung;Lee, Joon-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.1
    • /
    • pp.46-51
    • /
    • 2015
  • Stainless steel is a popular structural materials for liquid-hydrogen storage containers and piping components for transporting high-temperature fluids because of its superior material properties such as high strength and high corrosion resistance at elevated temperatures. In general, tungsten inert gas (TIG) arc welding is used for bonding stainless steel. However, it is often reported that the thermal fatigue cracks or initial defects in stainless steel after welding decreases the reliability of the material. The objective of this paper is to clarify the characteristics of ultrasonic guided wave propagation in relation to a change in the initial crack length in the welding zone of stainless steel. For this purpose, three specimens with different artificial defects of 5 mm, 10 mm, and 20 mm in stainless steel welds were prepared. By considering the thickness of s stainless steel pipe, special attention was given to both the L(0,1) mode and L(0,2) mode in this study. It was clearly found that the L(0,2) mode was more sensitive to defects than the L(0,1) mode. Based on the results of the L(0,1) and L(0,2) mode analyses, the magnitude ratio of the two modes was more effective than studying each mode when evaluating defects near the welded zone of stainless steel because of its linear relationship with the length of the artificial defect.

Surgical treatment on the stenosis of the esophagus (식도섬책에 대한 외과적 치료)

  • Kim, Geun-Ho;Kim, Yeong-Hak
    • Journal of Chest Surgery
    • /
    • v.22 no.1
    • /
    • pp.134-140
    • /
    • 1989
  • A clinical evaluation was made on total 207 cases of corrosive esophageal stricture after ingestion of various corrosive substances and 173 cases of neoplasms in the esophagus and the cardia. The various complications associated with esophageal corrosion were observed on 28 cases [13.5%] in a total of 207 cases. Pathoanatomic findings of complication may be classified to the five category as follow; [1] stenosis in the pharynx due to adhesion of the epiglottis, [2] esophagobronchial fistula, [3] esophageal perforation with bougienation, [4] necrotic rupture of the esophagus and the stomach, and [5] so-called chronic corrosive gastritis. The comparative studies were done on a total of 165 cases of the various procedures of esophagoplasty to the reconstruction of the esophagus, which consists of antethoracal esophagoplasty with jejunum, retrosternal esophagoplasty with jejunum, retrosternal esophagoplasty with right colon, and retrosternal esophagoplasty with left colon. There is no hard and fast rule in selection of jejunum, right colon or left colon as the transplanting bowel and an operative method either antethoracal or retrosternal approach. When there was no possibility of the complication and no any defect of the anatomical states, one stage retrosternal esophagoplasty using right colon was better in various points of view. The 173 patients of the neoplasm of the esophagus consist of 28 cases of benign tumors and 145 cases of malignant tumors in the esophagus and cardia. 28 cases of benign tumors in the esophagus received the surgical treatment and they obtained with excellent results postoperatively. Of the 145 patients of esophageal carcinoma who received surgical managements, 101 cases [69.6%] were found to be operable and 44 cases [30.3%] were inoperable. Due to the various level of carcinoma in the esophagus, the following different surgical procedure was properly used case by case to get the best results in each case. Esophageal carcinoma in the upper and middle third segment received the total esophagectomy and the reconstruction of the esophagus using right colon by substernal procedure. Esophageal carcinoma in the lower third segment received an esophagojejunostomy in the mediastinum after the resection of lower third segment of the esophagus. Carcinoma in the esophago cardia and the stomach received also an esophagojejunostomy after the resection of the lower third segment of the esophagus and subtotal gastrectomy. For the 44 patients with inoperable carcinoma, the several palliative surgical managements such as gastrostomy or jejunostomy for feeding and esophagojejunostomy for bypass of the lower esophagus and the stomach were properly performed case by case for their maximum improvement.

  • PDF

Thickness Evaluation of the Aluminum Using Pulsed Eddy Current (펄스 와전류를 이용한 알루미늄 두께 평가)

  • Lee, Jeong-Ki;Suh, Dong-Man;Lee, Seung-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.1
    • /
    • pp.15-19
    • /
    • 2005
  • Conventional eddy current testing has been used for the detection of the defect-like fatigue crack in the conductive materials, such as aluminum, which uses a sinusoidal signal with very narrow frequency bandwidth, Whereas, the pulsed eddy current method uses a pulse signal with a broad bandwidth. This can allow multi-frequency eddy current testing, and the penetration depth is greater than that of the conventional eddy current testing. In this work, a pulsed eddy current instrument was developed for evaluating the metal loss. The developed instrument was composed of the pulse generator generating the maximum square pulse voltage of 40V, an amplifier controlled up to 52dB, an A/D converter of 16 bit and the sampling frequency of 20 MHz, and an industrial personal computer operated by the Windows program. A pulsed eddy current probe was designed as a pancake type in which the sensing roil was located inside the driving roil. The output signals of the sensing roil increased rapidly wich the step pulse driving voltage かn off, and the latter part of the sensing coil output voltage decreased exponentially with time. The decrement value of the output signals increased as the thickness of the aluminum test piece increased.

Study on the Conservation of Scale Armor Using Duplication Technique - Focused on the Case of the Conservation Treatment of the Excavated Artifact from Jinyoung 2-Area, Gimhae - (복제 기법을 이용한 찰갑의 보존처리 - 김해 진영 2지구 출토품의 보존처리 사례를 중심으로 -)

  • Kim, Dong Min;Park, Jung Hyeok;Cho, Hyun Kyung;Cho, Nam Chul
    • Journal of Conservation Science
    • /
    • v.31 no.1
    • /
    • pp.75-86
    • /
    • 2015
  • A scale Armor is usually excavated in a scattered form weakened by corrosion after its burial. Therefore, they should be brought into the indoor in a safe environment for the on-site conservation treatment as it was excavated. They should be placed on a stable support with a reinforced base in the indoor treatment. In this process, the bottom surface which can not be observed after the conservation treatment is placed for a record by actual survey and photography. But this method had a limit on figuring out the whole aspects of the artifact. For compensating the defect, duplication of the artifact was considered as an alternative method for the previous two methods in the case of conservation of the scale Armor from Jinyoung 2-Area, Gimhae. Neck guard was excavated in a distorted form by the earth pressure, and was hard to recognize the original shape. However, whole real material of its original form was secured through the combination of each duplicated lamellae. Throughout the application of the duplication technique in the process of conservation of scale Armor and neck guard, it could secure the real material of the bottom surface and elevate the understanding of the artifact. Moreover, a constitution of the armor could be identified more effectively.

The Case Study of Design on Steel Pipe Sheet Pile for Earth Retaining Wall on Deep Excavation (대심도 지반굴착을 위한 벽강관말뚝 흙막이공법의 설계 사례 연구)

  • Byung-Il Kim;Jong-Ku Lee;Kyoung-Tae Kim;Kang-Han Hong;Sang-Jae Han
    • Journal of the Korean Geosynthetics Society
    • /
    • v.22 no.1
    • /
    • pp.53-66
    • /
    • 2023
  • In this study, the results of the elasto-plastic beam analysis, finite element analysis and optimization design of the steel pipe sheet pile applied as an earth retaining wall under the deep excavation were presented. Through this study, it was found that the high-strength and sea resistant steel pipe has high allowable stress, excellent structural properties, favorable corrosion, and high utilization as an earth retaining wall, and the C-Y type joint has significantly improved the tensile strength and stiffness compared to the traditional P-P type. In addition, it was investigated that even if the leak or defect of the wall occurs during construction, it has the advantage of being able to be repaired reliably through welding and overlapping. In the case of steel pipe wall, they were evaluated as the best in views of the deep excavation due to the large allowable bending stress and deformation flexibility for the same horizontal displacement than CIP or slurry wall. Elasto-plastic and finite element analysis were conducted in consideration of ground excavation under large-scale earth pressure (uneven pressure), and the results were compared with each other. Quantitative maximum value were found to be similar between the two methods for each item, such as excavation behavior, wall displacement, or member force, and both analysis method were found to be applicable in design for steel pipe sheet pile wall. Finally, it was found that economical design was possible when determining the thinnest filling method with concrete rather than the thickest hollow shape in the same diameter, and the depth (the embedded length through normality evaluation) without rapidly change in displacement and member force.