• 제목/요약/키워드: Corrosion Cell

검색결과 388건 처리시간 0.027초

Proposed Guidelines for Selection of Methods for Erosion-corrosion testing in Flowing Liquids

  • Matsumura, Masanobu
    • Corrosion Science and Technology
    • /
    • 제6권6호
    • /
    • pp.291-296
    • /
    • 2007
  • The corrosion of metals and alloys in flowing liquids can be classified into uniform corrosion and localized corrosion which may be categorized as follows. (1) Localized corrosion of the erosion-corrosion type: the protective oxide layer is assumed to be removed from the metal surface by shear stress or turbulence of the fluid flow. A macro-cell may be defined as a situation in which the bare surface is the macro-anode and the other surface covered with the oxide layer is the macro-cathode. (2) Localized corrosion of the differential flow-velocity corrosion type: at a location of lower fluid velocity, a thin and coarse oxide layer with poor protective qualities may be produced because of an insufficient supply of oxygen. A macro-cell may be defined as a situation in which this surface is the macro-anode and the other surface covered with a dense and stable oxide layer is the macro-cathode. (3) Localized corrosion of the active/passive-cell type: on a metal surface a macro-cell may be defined as a situation in which a part of it is in a passivation state and another in an active dissolution state. This situation may arise from differences in temperature as well as in the supply of the dissolved oxygen. Compared to uniform corrosion, localized corrosion tends to involve a higher wall thinning rate (corrosion rate) due to the macro-cell current as well as to the ratio of the surface area of the macro-anode to that of the macro-cathode, which may be rationalized using potential vs. current density diagrams. The three types of localized corrosion described above can be reproduced in a Jet-in-slit test by changing the flow direction of the test liquid and arranging environmental conditions in an appropriate manner.

고분자전해질형 연료전지 가스확산층의 탄소 부식에 관한 실험적 분석 (Experimental Study on Carbon Corrosion of Gas Diffusion Layer in PEM Fuel Cell)

  • 하태훈;조준현;박재만;민경덕;이은숙;정지영
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.76.1-76.1
    • /
    • 2010
  • Recently, many efforts to solve the durability problem of PEM fuel cell are carried on constantly. However, despite this attention, durability researches of gas diffusion layer (GDL) are not much reported yet. Generally, GDL of PEM fuel cell experiences three external attacks, which are dissolution of water, erosion of gas flow, corrosion of electric potential. In this study, among these degradation factors, carbon corrosion of electric potential was focused and investigated with accelerated carbon corrosion test. Through the test, it is confirmed that carbon corrosion occurred at GDL, and corroded GDL decreased a performance of operating fuel cell. The property changes of GDL were measured with various methods such as air permeability meter, pore distribution analyzer, thermo gravimetric analyzer, and tensile stress test to discover the effects of carbon corrosion. Carbon corrosion caused not only loss of weight and thickness, but also degradation of mechanical strength of GDL. In addition, to analysis the reason of GDL property changes, a surface and a cross section of GDL were observed with scanning electron microscope. After 100 hours test, the GDL showed serious damage in center of layer.

  • PDF

고온형 고분자 전해질막 연료전지(HT-PEMFC) 구동환경에 따른 탄소 담지체 부식 평가 (Effect of operating conditions on carbon corrosion in High temperature polymer electrolyte membrane fuel cells (HT-PEMFCs))

  • 이진희;김한성
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.89.1-89.1
    • /
    • 2011
  • The influence of potential and humidity on the electrochemical carbon corrosion in high temperature polymer electrolyte membrane fuel cells(HT-PEMFCs) is investigated by measuring $CO_2$ emission at different potentials for 30 min using on-line mass spectrometry. These results are compared with low tempterature polymer electrolyte membrane fuel cells(LT-PEMFCs) operated at lower temperature and higher humidity condition. Although the HT-PEMFC is operated at non humidified condition, the emitted $CO_2$ in the condition of HT-PEMFC is more than LT-PEMFC at the same potential in carbon corrosion test. Thus, carbon corrosion shows a stronger positive correlation with the cell temperature. In addition, the presence of a little amount of water activate electrochemical carbon corrosion considerably in HT-PEMFC. With increased carbon corrosion, changes in fuel cell electrochemical characteristics become more noticeable and thereby indicate that such corrosion considerably affects fuel cell durability.

  • PDF

반전지-전위 측정방법을 활용한 슬래그 콘크리트의 철근 부식 저항성능 평가 (Evaluation of Steel Corrosion of Slag Concrete by Half-cell Potential Method)

  • 이보경;김규용;김래환;윤민호;이영욱;최경철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 추계 학술논문 발표대회
    • /
    • pp.3-4
    • /
    • 2014
  • There is high probability of steel corrosion on the reinforced concrete exposed to marine environment by penetration of chloride ion. When making concrete structure with slag as admixture in marine environment, salt damage can be prevented. Therefore, this paper presents experimental results of steel corrosion resistance of slag concrete considering marine environment through half-cell potential method which is one of the nondestructive test. As a result of half-cell potential experiment, it was assumed that every specimen exposed to marine environment was not corroded, and as a result of destroying specimens, it was confirmed that there was no corrosion in specimens.

  • PDF

용융탄산염연료전지(MCFC) 스택의 1200시간 운전 후 분리판 채널부 표면 열화 분석 및 연구 (Study of Corrosion and Post Analysis for the Separator Channel of MCFC Stack after Cell Operation for 1200 hours)

  • 조계현
    • 한국표면공학회지
    • /
    • 제40권3호
    • /
    • pp.149-158
    • /
    • 2007
  • Of all components of MCFC(molten carbonate fuel cell), corrosion of separator is one of the most decisive factor for commercializing of MCFC. In order to provide better understanding of corrosion behavior and morphology for gas channel of separator plate, post-analysis after cell operation for 1200 hours at $650^{\circ}C$ was performed by optical microscope, SEM and EPMA. Intergranular corrosion was observed on gas channel of separator plate. Corrosion product layer was identified as Fe-oxide, Cr-oxide and Ni-oxide by EPMA, and oxide thickness was measured with a $60{\mu}m-150{\mu}m$. Also, gas channel of separator was damaged by severe intergrannular attack with post analysis in consistent with immersion test. Moreover, pitting on the channel plate was observed with a depth of $18{\sim}24{\mu}m$. The results of immersion method are well agreement with post analysis measurements.

고로슬래그 미분말을 사용한 콘크리트 내의 철근부식에 관한 실험적 연구 (An Experimental Study on the Reinforcement Corrosion in Concrete Using Granulated Blast Furnace Slag)

  • 이동혁;김은겸;김영웅;김영철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.761-766
    • /
    • 2002
  • This paper was peformed to verify the effect that granulated blast furnace slag gets in reinforcement corrosion resistance about chloride ion that invade from outside. An experiment accelerated for the reinforcement corrosion through repeat of brine digestion and dry. Reinforcement corrosion investigated half cell potential method of measurement by ASTM C876 and corrosion area ratio. If granulated blast furnace slag metathesis ratio is high generally that looked the corrosion of reinforcement decreasing as a result that evaluate reinforcement corrosion by ASTM C876 canon in this research. It showed high resistance about reinforcement corrosion that use normal portland cement and increase the metathesis rate of granulated blast furnace slag, as a result that evaluate metathesis rate effect of granulated blast furnace slag according to cement kind. when the test piece split destroying, area rate of reinforcement corrosion showed about result of half cell potential measurement.

  • PDF

Corrosion of rebar in carbon fiber reinforced polymer bonded reinforced concrete

  • Bahekar, Prasad V.;Gadve, Sangeeta S.
    • Advances in concrete construction
    • /
    • 제8권4호
    • /
    • pp.247-255
    • /
    • 2019
  • Several reinforced concrete structures that get deteriorated by rebar corrosion are retrofitted using Carbon Fiber Reinforced Polymer (CFRP). When rebar comes in direct contact with CFRP, rebar may corrode, as iron is more active than carbon. Progression of corrosion of rebar in strengthened RC structures has been carried out when rebar comes in direct contact with CFRP. The experimentation is carried out in two phases. In phase I, corrosion of bare steel bar is monitored by making its contact with CFRP. In phase II, concrete specimens with surface bonded CFRP were casted and subjected to the realistic exposure conditions keeping direct contact between rebar and CFRP. Progression of corrosion has been monitored by various parameters: Half-cell potential, Tafel extrapolation and Linear Polarisation Resistance. On termination of exposure, to find residual bond stress between rebar and concrete, pull-out test was performed. Rebar in contact with CFRP has shown substantially higher corrosion. The level of corrosion will be more with more area of contact.

Micro-droplet cell을 이용한 Fe-17Cr 합금의 공식 발생에 대한 연구 (A Study on the Initiation of Pitting Corrosion of Fe-17Cr Alloy Using Micro-Droplet Cell Technique)

  • 김재중;이재봉
    • 대한금속재료학회지
    • /
    • 제46권12호
    • /
    • pp.809-816
    • /
    • 2008
  • The influences of various parameters such as inclusions, surface roughness, exposed areas and chloride ion concentrations on the initiation of pitting of Fe-17Cr alloy were investigated, using micro-droplet cell technique. Micro-droplet cell allows one to align the micro-electrode to the desired spot of the working electrode and measure directly local currents with the potentiodynamic polarization. Micro electrochemical tests were carried out at the inclusions after EDX analysis of inclusion. EDX analysis identified inclusions as Cr-oxides. It was found that some active inclusions among Cr-oxide inclusions acted as initiation sites for pitting corrosion. In addition, the rougher surface and the denser chloride ion concentration offered easier pit initiation sites, causing the more susceptible to pitting corrosion.

해양환경하에 방치한 콘크리트중의 철근의 부식 추정에 대한 연구 (A Study on the Estimation of Steel Corrosion in Concrete Exposed under the Environment of Seawater)

  • 문한영;김성수;류재석
    • 콘크리트학회지
    • /
    • 제6권2호
    • /
    • pp.129-137
    • /
    • 1994
  • 해양환경하에 있는 콘크리트 구조물의 열화를 알아보고 철근의 부식 정도를 추정하기 위한 연구내용으로서 콘크리트 중에 철근을 묻은 공시체를 제작하여 간만의 차가 있는 해변에 1년 동안 노출시킨 상태로 시험을 실시 하여 콘크리트 중의 가용성 염분량, 철근의 자연전위값 및 철근의 부식정도에 대하여 고찰하였다. 본 연구 결과 콘크리트 중의 가용성 염분량은 물-시멘트비가 낮을수록, 혼화재를 혼입할 경우 적게 나타났으며 가용성 염분량이 클수록 철근의 부식이 크게 나타났다. 철근 부식의 정도가 심할수록 자연전위값이 감소하였으며 자연전위와 부식면적율과는 상관관계가 있음을 알 수 있었다.

PEMFC 금속 분리판용 316L 스테인리스강의 전기화학적 특성 및 손상 거동에 미치는 온도 및 염화물 농도의 영향 (Effects of Temperature and Chloride Concentration on Electrochemical Characteristics and Damage Behavior of 316L Stainless Steel for PEMFC Metallic Bipolar Plate)

  • 신동호;김성종
    • Corrosion Science and Technology
    • /
    • 제21권4호
    • /
    • pp.300-313
    • /
    • 2022
  • Interest in polymer electrolyte fuel cell is growing to replace fossil fuels. In particular, in order to reduce the cost and volume of the fuel cell, research on a metallic bipolar plate is being actively conducted. In this research, investigated the effects of temperature and chloride concentration on the electrochemical characteristics and damage behavior of 316L stainless steel in an accelerated solution simulating the cathodic operating condition of PEMFC(Polymer electrolyte membrane fuel cell). As a result of the experiments, the corrosion current density, damage size, and surface roughness increased as the temperature and chloride concentration increased. In particular, the temperature had a significant effect on the stability of the oxide film of 316L stainless steel. In addition, it was described that the growth of the pit was affected by the chloride concentration rather than the temperature. As a result of calculating the corrosion tendency to compare the pitting corrosion rate and the uniform corrosion rate, the uniform corrosion tendency became larger as the temperature increased. And the effects of chloride concentration on corrosion tendency was different according to temperature.