• 제목/요약/키워드: Correlation test

검색결과 12,446건 처리시간 0.042초

빈혈환자에서 자동 ESR 기기인 Test 1과 Westergren법의 비교 (Comparative Evaluation of Erythrocyte Sedimentation Rate by the Test 1 Analyzer and Westergren method in Patients with Anemia)

  • 김일택;김종석;박연보;임재실
    • 대한임상검사과학회지
    • /
    • 제36권2호
    • /
    • pp.137-143
    • /
    • 2004
  • Erythrocyte sedimentation rate(ESR) measurements were performed in a total of 191 blood samples from patients below a hematocrit of 35% by both the Test-1(SIRE Analytical Systems, Udine, Italy) and the Westergren method, endorsed as the reference method for ESR by the International Council for Standardization in Hematology(ICSH). The corrected Westergren ESR values were also obtained applying the formula of Fabry (corrected ESR = ESR measured x 15/55-Hct). Linear regression analysis showed a close correlation (r=0.85) between the two methods both before and after ESR correction in total samples. There was no significant correlation difference between two methods in both two groups with hemoglobin $${\geq_-}9g/dl$$ and <9g/dl before and after ESR correction (r=0.873, r=0.827 respectively before correction and r=0.867, r=0.830 respectively after correction). Also, for two groups with hematocrit $${\geq_-}24%$$ and <24%, no significant difference was observed (r=0.859, r=0.792 respectively before correction and r=0.782, r=0.842 respectively after correction). However, for samples with <60mm of Westergren ESR before correction, a better correlation coefficient was obtained than samples with $${\geq_-}60mm$$(r=0.701, r=0.541 respectively). In corrected Westergren ESR, also samples that were obtained with <40mm showed better correlation than samples with $${\geq_-}40mm$$ (r=0.690, r=0.347 respectively). In conclusion, we found a good correlation between Test-1 and Westergren measurements in patients with anemia but an expert group discussion is required to solve discrepancy between two methods in blood samples with very high ESR.

  • PDF

비탈면 취약도 평가를 위한 동적콘관입시험기 모듈개발과 표준관입시험값과의 상관관계 연구 (Development of Dynamic Cone Penetration Tester Module for Slope Vulnerability Assessment and Correlation of Its Results with Standard Penetration Test Values)

  • 채휘영;권순달
    • 지질공학
    • /
    • 제31권4호
    • /
    • pp.541-547
    • /
    • 2021
  • 비탈면의 유실, 붕락사고 등 비탈면에 대한 안정성을 파악하기 위해서 지층의 구성상태, 역학적 특성 등의 지반정보 파악이 필요하다. 이러한 지반정보를 파악하기 위해서 일반적으로 표준관입시험(SPT) 및 콘 관입시험 등이 널리 이용되고 있다. 대부분이 급경사로 이루어지고 진입로가 없는 비탈면에 대한 접근성 문제로 표준관입시험이 널리 활용되지 못하고 있다. 이러한 단점을 보완할 수 있는 있는 휴대용 장비인 Drop Cone Penetrometer(DCP)를 이용한 조사도 여러 가지 문제로 제한적으로 사용되고 있다. 따라서 본 연구에서는 비탈면 현장접근이 용이한 휴대용 시추기와 동적콘관입시험 모듈을 개발하고, 개발된 동적콘관입시험기를 이용한 결과와 동일 현장에서 수행한 표준관입시험값과 상관성을 분석하였다. 에너지전단율로 보정된 동적콘관입시험과 표준관입시험간의 상관식은 Nd' = 3.13 N'으로 나타났다.

청소년기 특발성 척추측만증 환자의 임상적 균형 평가지수와 균형 수행 모니터 측정값의 상관성 연구 (The study of correlations between clinical balance scales and balance performance monitor parameters in patients with adolescent idiopathic scoliosis)

  • 신승섭
    • PNF and Movement
    • /
    • 제8권3호
    • /
    • pp.39-47
    • /
    • 2010
  • Purpose : The purpose of this study was to investigate the correlations between clinical balance scales and Balance Performance Monitor parameters in patient with adolescent idiopathic scoliosis (AIS). Methods : Twenty AIS subjects (age, $14.26{\pm}1.93yrs$; height, $160.56{\pm}7.98cm$; weight, $47.54{\pm}6.94kg$)were participated in this study. Postural sway(mean balance, sway angle, sway area, sway path, maximal sway velocity) were were evaluated by balance performance monitor. Measurements for clinical balance scales were Functional reach test (both side), the Lateral reach test (both side) and One leg standing test (both legs). Results : The results were as follows. There were positive strong correlation between major curve direction and left-right sway angle, sway path, maximal sway velocity. There were negative strong correlation between the functional reach and left-right sway angle, sway area, sway path, maximal sway velocity. And the lateral reach were also showed negative strong correlation parameters of balance performance monitor. One leg standing were negatively correlated with left-right sway angle, sway path, maximal sway velocity. Conclusion : The clinical balance scales will be useful tools for balance measurements, and basic tools for clinical setting for patient with AIS.

  • PDF

소아용 균형 감각검사(PCTSIB)를 이용한 6세 및 7세 아동의 균형 수행력 비교 (A Comparative Study of Balance Performance in 6,7 years old by means of the Pediatric Clinical Test of Sensory Interaction for Balance)

  • 이한숙;권혁철;김진상
    • The Journal of Korean Physical Therapy
    • /
    • 제11권1호
    • /
    • pp.87-93
    • /
    • 1999
  • The purpose of this study were to compare the balance performance with 44 children, who aged 6 and 7years old by means of the Pediatric Clinical Test of Sensory Interaction for Balance(PCTSIB), second is to determine whether age and gender-relatad difference were present, third is to found correlation of weight, height with duration of balance performance. All subjects were performed with different foot position that were feet-together, heel-toes. The starting position was that subject placed their hands on the hips. The results of each test were measured by stop watch. These collected data were analyzed by using oneway ANOVA, Sheffe test t-test and correlation. The results of this study were as follows ; 1. There were all significiant difference is all instances except condition 4 with heel-toes(p<0.05). The duration of balance performance of 7-year-olds group was more increased than 6-year-olds group. 2. There was statistically significiant difference in all instances by gender(p<0.05). 3. There was no correlation between weight or height duration of balance performance (p<0.05).

  • PDF

자아탄력성, 학업적 자아개념이 대학생의 시험불안에 미치는 영향 (The Influence of Self-resilience and Academic Self-concept on Test Anxiety in Undergraduates)

  • 유혜숙;양야기
    • 기본간호학회지
    • /
    • 제21권3호
    • /
    • pp.275-282
    • /
    • 2014
  • Purpose: This study was conducted to investigate the relationship of self-resilience, academic self-concept and test anxiety in undergraduates. Method: The participants were 403 undergraduates in H, C University in G City, and K University in S City. Data were collected from March 1 to April 30, 2012, and analyzed using SPSS/WIN 18.0. Results: The mean score per item for self-resilience was 2.77. The mean academic self-concept score was 3.17 and the mean score for test anxiety was 2.38. Self-resilience showed a negative correlation with test anxiety (r=-.186, p<.001) and a positive correlation with academic self-concept (r=.312, p<.001). Academic self-concept showed a negative correlation with test anxiety (r=-.353, p<.001). Conclusion: The findings of this study indicate that self-resilience and academic self-concept enhancement programs should be developed to reduce test anxiety in undergraduates and that further study should be done on the effects of such programs.

Correlation between Insulation Diagnostic Test and AC Breakdown Test for 3.3 kV Class Induction Motor

  • Byun, Doo-Gyoon;Hong, Jin-Woong
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권5호
    • /
    • pp.262-266
    • /
    • 2006
  • The insulation diagnostic test and the AC breakdown test were performed under off-line using the 3.3 kV class induction motor which have been served for 10 years. These tests were conducted in means of nondestructive and destructive test. In this paper, we compared the correlation between the nondestructive and destructive test. Furthermore we setup an experimental condition with moisture and compared the insulation characteristics between moist and dry sample. From the results of the nondestructive and destructive test, it was found that the second AC current, which is the previous step of insulation breakdown, suddenly increased at a point of around 8.5 kV. The insulation breakdown of moist sample occurred at 12-14 kV, which is 4-5 kV lower than dry sample.

연약지반에 대한 기계식 및 전자식 콘관입시험 비교 연구 (Comparative study of Dutchcone and piezocone test on soft ground)

  • 장병욱;김재현;김동범;윤상묵;원정윤
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.237-244
    • /
    • 2002
  • A comparative study of 134 mechanical (Dutch cone) and 9. electronic cone (Piezocone) penetration data from the southern part of Korea has been performed. In general, Dutch cone results may be different from piezocone results due to the difference in structure of the cones. Cone penetrometer test data were analyzed and plotted in soil classification chart proposed by Robertson et. al.(1986,1990) Cone factors of Dutch cone and piezocone test have empirically been determined using laboratory and field vane test results. Using this cone factors, it was shown that there was good correlation between shear strength estimated using cone resistance and that of laboratory test and field vane tests. It was found that there was a good correlation between cone resistance from Dutch cone and that from piezocone. Dutch cone test provides a useful means for stratigraphic profiling in large project and has some advantage over piezocone in particular situations, such as very soft clay ground and dredged area.

  • PDF

Influence Analysis on a Test Statistic in Canonical Correlation Analysis

  • Jung, Kang-Mo
    • Communications for Statistical Applications and Methods
    • /
    • 제8권2호
    • /
    • pp.347-355
    • /
    • 2001
  • We propose a method for detecting influential observations that have a large influence on the likelihood ratio test statistic for the two sets of variables are uncorrelated with one another. For this purpose we derive a local influence measure for the likelihood ratio test statistic under certain perturbation scheme. An illustrative example is given to show the effectiveness of the proposed method on the identification of influential observations.

  • PDF

골재 미립분에 포함된 토분의 분석방법 고찰 (A Study on the Analysis Method of Soil Dust Included in the Aggregate Fines)

  • 민태범;김인;이재삼;백철승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.257-258
    • /
    • 2023
  • As a result of examining research contents related to soil excretion being studied in Korea, there are five methods for soil excretion testing. As a result of analyzing the correlation between each test method and concrete compressive strength, the chemical test method and the Methylene blue test showed a high correlation index.

  • PDF

Concurrent Validity and Test-retest Reliability of the Core Stability Test Using Ultrasound Imaging and Electromyography Measurements

  • Yoo, Seungju;Lee, Nam-Gi;Park, Chanhee;You, Joshua (Sung) Hyun
    • 한국전문물리치료학회지
    • /
    • 제28권3호
    • /
    • pp.186-193
    • /
    • 2021
  • Background: While the formal test has been used to provide a quantitative measurement of core stability, studies have reported inconsistent results regarding its test-retest and intraobserver reliabilities. Furthermore, the validity of the formal test has never been established. Objects: This study aimed to establish the concurrent validity and test-retest reliability of the formal test. Methods: Twenty-two young adults with and without core instability (23.1 ± 2.0 years) were recruited. Concurrent validity was determined by comparing the muscle thickness changes of the external oblique, internal oblique, and transverse abdominal muscle to changes in core stability pressure during the formal test using ultrasound (US) imaging and pressure biofeedback, respectively. For the test-retest reliability, muscle thickness and pressure changes were repeatedly measured approximately 24 hours apart. Electromyography (EMG) was used to monitor trunk muscle activity during the formal test. Results: The Pearson's correlation analysis showed an excellent correlation between transverse abdominal thickness and pressure biofeedback unit (PBU) pressure as well as internal oblique thickness and PBU pressure, ranging from r = 0.856-0.980, p < 0.05. The test-retest reliability was good, intraclass correlation coefficient (ICC1,2) = 0.876 for the core stability pressure measure and ICC1,2 = 0.939 to 0.989 for the abdominal muscle thickness measure. Conclusion: Our results provide clinical evidence that the formal test is valid and reliable, when concurrently incorporated into EMG and US measurements.