• Title/Summary/Keyword: Correlated errors

Search Result 133, Processing Time 0.025 seconds

A Study on Numerical Modeling of Dynamic CPT using Particle Flow Code (입자결합모델을 이용한 동적콘관입시험(DCPT)의 수치해석 모델링에 관한 연구)

  • You, Kwang Ho;Lee, Chang Su;Choi, Jun Seong
    • International Journal of Highway Engineering
    • /
    • v.16 no.2
    • /
    • pp.43-52
    • /
    • 2014
  • PURPOSES : To solve problems in current compaction control DCPT(Dynamic Cone Penetrometer Test), highly correlated with various testing methods, simple, and economic is being applied. However, it、s hard to utilize DCPT results due to the few numerical analyses for DCPT have been performed and the lack of data accumulation. Therefore, this study tried to verify the validation of numerical modeling for DCPT by comparing and analyzing the results of numerical analyses with field tests. METHODS: The ground elastic modulus and PR(Penetration Rate) value were estimated by using PFC(Particle Flow Code) 3D program based on the discrete element method. Those values were compared and analyzed with the result of field tests. Also, back analysis was conducted to describe ground elastic modulus of field tests. RESULTS : Relative errors of PR value between the numerical analyses and field tests were calculated to be comparatively low. Also, the relationship between elastic modulus and PR value turned out to be similar. CONCLUSIONS : Numerical modeling of DCPT is considered to be suitable for describing field tests by carrying out numerical analysis using PFC 3D program.

Simplified Procedure of Amylose Analysis by Rapid Flow Autoanalyzer RFA-300 (자동분석기 RFA-300 이용한 아밀로스 분석법)

  • Choi, Hae-Chune;Son, Yong-Hee;Cho, Soo-Yeon
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.38 no.1
    • /
    • pp.66-71
    • /
    • 1993
  • Several trials and errors were repeated to develop a simplified recipe of amylose analysis using a Rapid Flow Autoanalyzer(Alpkem, RFA-300). The amylose content of rice samples analyzed by the Rapid Flow Autoanalyzer were compared with those of Williams’ and Juliano’s assay. The results by the simplified recipe of RFA amylose analysis were highly correlated with those by Williams’ and Juliano’s method(r=0.95$^{**}$-0.97$^{**}$). The relative amylose content of defatted rice starch was higher than those of non-defatted rice flour, showing very close correlations between those analyzed by three method.

  • PDF

Case study on the Accuracy Assessment of the rainrate from the Precipitation Radar of TRMM Satellite over Korean Peninsula

  • Chung, Hyo-Sang;Park, Hye-Sook;Noh, Yoo-Jeong
    • Proceedings of the KSRS Conference
    • /
    • 1999.11a
    • /
    • pp.103-106
    • /
    • 1999
  • The Tropical Rainfall Measuring Mission(TRMM) is a United States-Japan project for rain measurement from space. The first spaceborne Precipitation Radar(PR) has been installed aboard the TRMM satellite. The ground based validation of the TRMM satellite observations was conducted by TRMM science team through a Global Validation Program(GVP) consisted of 10 or more ground validation sites throughout the tropics. However, TRMM radar should always be validated and assessed against reference data to be used in Korean Peninsula because the rainrates measured with satellite varies by time and space. We have analyzed errors in the comparison of rainrates measured with the TRMM/PR and the ground-based instrument i.e. Automatic Weather System(AWS) by means of statistical methods. Preliminary results show that the near surface rainrate of TRMM/PR are highly correlated with ground measurements especially for the very deep convective rain clouds, though the correlation is changed according to the type and amount of precipitating clouds. Results also show that TRMM/PR instrument is inclined to underestimate the rainrate on the whole over Korea than the AWS measurement for the cases of heavy rainfall.

  • PDF

Study of the compression index for Busan and Inchon clays (부산점토와 인천점토의 압축지수 분석)

  • Hong, Sung-Jin;Choi, Yung-Min;Lee, Joo-Hyung;Lee, Moo-Joo;Lee, Woo-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.1200-1205
    • /
    • 2010
  • The compression index is one of the geotechnical properties which represent the compressibility of clay. The compression index are generally obtained from consolidation tests, otherwise it has been predicted by soil properties due to the efficiency time and cost. In this study, consolidation tests result for Busan and Inchon clays are analyzed to suggest the correlations between the compression index and soil properties. It is found that the compression index is well correlated with the void ratio and natural water contents. The prediction errors, which is difference of compression indices between measured from consolidation test and predicted by liquid limits, decrease with ${\Delta}e_0/e_L$.

  • PDF

Signal Detection for Pattern Dependent Noise Channel (신호패턴 종속잡음 채널을 위한 신호검출)

  • Jeon, Tae-Hyun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.14 no.5
    • /
    • pp.583-586
    • /
    • 2004
  • Transition jitter noise is one of major sources of detection errors in high density recording channels. Implementation complexity of the optimal detector for such channels is high due to the data dependency and correlated nature of the jitter noise. In this paper, two types of hardware efficient sub-optimal detectors are derived by modifying branch metric of Viterbi algorithm and applied to partial response (PR) channels combined with run length limited modulation coding. The additional complexity over the conventional Viterbi algorithm to incorporate the modified branch metric is either a multiplication or an addition for each branch metric in the Viterbi trellis.

Comparison of 3-D structures of Halo CMEs using cone models

  • Na, Hyeon-Ock;Moon, Y.J.;Jang, Soo-Jeong;Lee, Kyoung-Sun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.1
    • /
    • pp.95.1-95.1
    • /
    • 2012
  • Halo coronal mass ejections (HCMEs) are major cause of geomagnetic storms and their three dimensional structures are important for space weather. In this study, we compare three cone models: an elliptical cone model, an ice-cream cone model, and an asymmetric cone model. These models allow us to determine the three dimensional parameters of HCMEs such as radial speed, angular width, and the angle (${\gamma}$) between sky plane and cone axis. We compare these parameters obtained from three models using 62 well-observed HCMEs from 2001 to 2002. Then we obtain the root mean square error (RMS error) between maximum measured projection speeds and their calculated projection speeds from the cone models. As a result, we find that the radial speeds obtained from the models are well correlated with one another (R > 0.84). The correlation coefficients between angular widths are less than 0.53 and those between ${\gamma}$ values are less than 0.47, which are much smaller than expected. The reason may be due to different assumptions and methods. The RMS errors of the elliptical cone model, the ice-cream cone model, and the asymmetric cone model are 213 km/s, 254 km/s, and 267 km/s, respectively. Finally, we discuss their strengths and weaknesses in terms of space weather application.

  • PDF

Accuracy Evaluation of Tidal Volume Measured on the Abdomen (복부에서 측정하는 일회 호흡용적의 정확도 평가)

  • Lee, In-Kwang;Kim, Seong-Sik;Jang, Jong-Chan;Kim, Koon-Jin;Kim, Kyung-Ah;Lee, Tae-Soo;Cha, Eun-Jong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.7
    • /
    • pp.1298-1303
    • /
    • 2008
  • Respiration is induced by muscular contraction of the chest and abdomen, resulting in the abdominal volume change. Thus, continuous measurement of the abdominal dimension enables to monitor breathing activity. Conductive rubber cord has been previously introduced and tested to develop wearable application for respiratory measurements. This study implemented respiratory monitoring system with the conductive rubber cord in the patient's pants in purpose of quantitative estimation of tidal volume. Air mixed with $0{\sim}5%$ $CO_2$ was inhaled and the respiratory air flow rate, abdominal dimension change, and end tidal $CO_2$ concentration were simultaneously measured in steady state. $CO_2$ inhalation significantly increased the tidal volume in normal physiological state with the subject unawared. The tidal volume estimated from the abdominal dimension change linearly correlated with the tidal volume measured by a pneumotachometer with a correlation coefficient of 0.88. Customized calibration for each subject resulted in relative errors less than 10%. Therefore, the tidal volume was accurately estimated by measuring the abdominal dimension change.

Indocyanine Green Videoangiography for Confirmation of Bypass Graft Patency

  • Schuette, Albert J.;Dannenbaum, Mark J.;Cawley, Charles M.;Barrow, Daniel L.
    • Journal of Korean Neurosurgical Society
    • /
    • v.50 no.1
    • /
    • pp.23-29
    • /
    • 2011
  • Objective : The aim of the study is to determine the efficacy of indocyanine green (ICG) videoangiography for confirmation of vascular anastomosis patency in both extracranial-intracranial and intracranial-intracranial bypasses. Methods : Intraoperative ICG videoangiography was used as a surgical adjunct for 56 bypasses in 47 patients to assay the patency of intracranial vascular anastomosis. These patients underwent a bypass for cerebral ischemia in 31 instances and as an adjunct to intracranial aneurysm surgery in 25. After completion of the bypass, ICG was administered to assess the patency of the graft. The findings on ICG videoangiography were then compared to intraoperative and/or postoperative imaging. Results : ICG provided an excellent visualization of all cerebral arteries and grafts at the time of surgery. Four grafts were determined to be suboptimal and were revised at the time of surgery. Findings on ICG videoangiography correlated with intraoperative and/or postoperative imaging. Conclusion : ICG videoangiography is rapid, effective, and reliable in determining the intraoperative patency of bypass grafts. It provides intraoperative information allowing revision to reduce the incidence of technical errors that may lead to early graft thrombosis.

Unambiguous Identification of Fugitive Pollutants and Determination of Annual Emission Flux as Diurnal Monitoring Mode

  • Chang, Shih-Yi;Tso, Tai-Ly;Lo, Jiunn-Gung;Huang, Jer-Luen;Lin, Cheng Ming
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.731-738
    • /
    • 1995
  • Toxic air pollutants are investigated in a petrochemical industrial park in Taiwan by using a movable open path FTIR. The results show the qualitative and quantitative analysis of emission gases from plants, and also provide the emission rate of different compounds. More than twenty compounds under usual operation are found from this industrial park. The concentration variation with time can be correlated exactly with wind direction. It means that by changing the measuring points, the source of emission can be unambiguously identified. An EPA proved PAL model is applied to estimate the emission rate of either a point or an area source. Local atmospheric stability is determined by releasing the $SF_6$ tracer. The origins of errors come mainly from the uncertainty of source's configuration and the variation of meteorological condition. Through the continuous measurement (half an hour base in this study) of OP-FTIR sensor, the maximum value of emission rate and the annual amount of emission can be derived. The emission rate of the measured toxic gases are derived by the model technique and the results show that the emission amount are in the order of ten to hundred tons per year.

  • PDF

Analysis of Measurement Error for PM-2.5 Mass Concentration by Inter-Comparison Study (비교 실험을 통한 PM-2.5 질량농도의 측정오차 분석)

  • Jung, Chang-Hoon;Park, Jin-Hee;Hwang, S.M.
    • Journal of Environmental Impact Assessment
    • /
    • v.19 no.4
    • /
    • pp.431-441
    • /
    • 2010
  • In this study, inter-comparison for PM-2.5 was undertaken. The PM-2.5 mass concentrations using the gravimetric and beta-attenuation methods were compared during the winter in 2007. Two different types of conventional filter-based measurements (Cyclone type and Impactor type) were also collocated and the measurement data was compared with each other. As a result, continuous PM-2.5 data using beta attenuation method show a comparable mass concentration with gravimetric measurement when the inlet of beta-gauge sampler is heated. The results also showed that the cyclone type shows a little high PM-2.5 concentration than Impactor type. In all the sampling cases, the correlations between measurement methods are high. Subsequently, this study suggests that highly correlated relationship between PM-2.5 measurement instruments can be obtained through the inter-comparison results based on filterb-ased gravimetric method and more intensive measurement and theoretical studies are needed in order to clarify the measurement errors for different sampler types.