• Title/Summary/Keyword: Corrective control

Search Result 125, Processing Time 0.029 seconds

GPS Anti-Jamming Using Beamforming Technique (빔포밍 기법을 이용한 GPS 재밍 대응)

  • Choi, Chang-Mook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.2
    • /
    • pp.451-456
    • /
    • 2016
  • Because GPS signals are weak, system jamming is a real and present danger. This can happen when the receiver is subjected to intentional or unintentional interference by a transmitter. If the jamming signal is strong enough, the receiver can be operated to take corrective action automatically. Current methods to protect GPS receiver from jamming condition are based on spatial filtering. In this paper, the beamforming as referred to in signal processing technique used in arrays for directional signal reception was suggested and analyzed for anti-jamming. In order to change the directionality of the array when receiving a jamming signal, a beamformer can control the signal at each sensor. Therefore, cutoff angle ${\theta}$ was measured in the opposite direction of the jammer. GPS signals are only processed when the antenna element is within inside the cutoff angle. As a result, GPS positioning can be used in condition under cutoff angle $30^{\circ}$.

Remanufacturing Process Design for Automotive Alternator (자동차 교류발전기의 재제조 프로세스 설계)

  • Roslan, Liyana;Azmi, Nurul Ain;Jung, Won
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.34 no.4
    • /
    • pp.179-188
    • /
    • 2011
  • This paper outlines a systematic guideline for remanufacturing process using the Failure Mode and Effect Analysis (FMEA) method in order to estimate the reliability and quality of the remanufactured alternator. The method is just a tool to help, but the remanufacturer must determine the optimal remanufacturing process and specific inspection and production that will turn the alternator as-good-as new and place the product into the market with reliability and quality equal to a new product. FMEA is a method that is widely used in industry and has shown its value and effectiveness in the above remanufacturing case study. Actions taken often result in a lower severity, occurrence or detection rating. Redesign may result in lower severity and occurrence ratings while inserting validation controls and maintenance can reduce the detection rating. The revised ratings are recorded with the originals on the FMEA template form. After these corrective actions and revisions have been established, evaluation of the ranks can be repeated, until the redesign and control parameters comply with safety standards.

Airway Evaluation for Endotracheal Intubation of Mandibular Prognathic Patient (하악전돌증 환자에서 기관내 삽관을 위한 기도평가에 관한 연구)

  • Lee, Sung-Ju;Kim, Hyun-Jeong;Yum, Kwang-Won
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.3 no.1 s.4
    • /
    • pp.28-33
    • /
    • 2003
  • Background: The fundamental responsibility of an anesthesiologist is to maintain adequate gas exchange. Failure to maintain a patent airway can result in brain damage or death. Generally, in patients with mandibular prognathism, who have the protruded mandible, the mask ventilation was thought to be not easy. The purpose of this study was to observe the degree of the difficulty of airway management in mandibular prognathism using some anatomic criteria for defining and grading difficulty of airway and difficulty of endotracheal intubation with direct laryngoscope. Methods: The observations and measurements are done to the 54 patients with mandibular prognathism, who were scheduled for corrective esthetic surgery. The case study is done to the 30 patients with normal mandible for control group. In all patients, mouth opening distance (MOD), mouse opening angle (MOA), mandibular length (ML), mandibular depth (MD), thyromental distance (TMD), thyromental area (TMA), Mallampati grades, and Cormack and Lehane grades are measured. T-test and Chi-square test are done (P < 0.05). Results: In the mandibular prognathism cases, the measurements of MD, TMD and TMA are more greater than those of controls (P < 0.05). Mallampati grades with tongue thrust are higher in the female mandibular prognathism cases than those of female controls. Most of the grades of the mandibular prognathism cases with Cormack and Lehane grading system are I or II being easy intubation cases (P < 0.05) Conclusions: In the patients of mandibular prognathism, the intubation with laryngoscope will be easer than that of normal mandible in general. It is for that their laryngeal aperture can be easily visible when the laryngoscope are used.

  • PDF

Unstable Approach Mitigation Based on Flight Data Analysis (비행 데이터 분석 기반의 불안정 접근 경감방안)

  • Kim, Hyeon Deok
    • Journal of Advanced Navigation Technology
    • /
    • v.25 no.1
    • /
    • pp.52-59
    • /
    • 2021
  • According to the International Air Transport Association (IATA), 61% of the accidents occurred during the approach and landing phase of the flight, with 16% of the accidents caused by unstable access of the commercial aircraft. It was identified that the pilot's unstable approach and poor manipulation of correction led to accidents by continuing the excessive approach without go-around manuever. The causes of unstable access may vary, including airport approach procedures, pilot error, misplanning, workload, ATC (Air Traffic Contol) congestion, etc. In this study, we use the flight data analysis system to select domestic case airports and aircraft type where unstable approach events occur repeatedly. Through flight data analysis, including main events, airport approach procedures, pilot operations, as well as various environmental factors such as weather and geographical conditions at the airport. It aims to identify and eliminate the tendency of unstable approach events and the causes and risks of them to derive implications for mitigating unstable approach events and for developing navigation safety measures.

SWOT Analysis and Expert Assessment of the Effectiveness of the Introduction of Healthcare Information Systems in Polyclinics in Aktobe, Kazakhstan

  • Lyudmila, Yermukhanova;Zhanar, Buribayeva;Indira, Abdikadirova;Anar, Tursynbekova;Meruyert, Kurganbekova
    • Journal of Preventive Medicine and Public Health
    • /
    • v.55 no.6
    • /
    • pp.539-548
    • /
    • 2022
  • Objectives: The purpose of this study was to assess the organizational effectiveness of the introduction of a healthcare information system (electronic medical records and databases) in healthcare in Kazakhstan. Methods: The authors used a combination of 2 methods: expert assessment and strengths, weaknesses, opportunities, and threats (SWOT) analysis. SWOT analysis is a necessary element of research, constituting a mandatory preliminary stage both when drawing up strategic plans and for taking corrective measures in the future. The expert survey was conducted using 2 questionnaires. Results: The study involved 40 experts drawn from specialists in primary healthcare in Aktobe: 15 representatives of administrative and managerial personnel (chief doctors and their deputies, heads of medical statistics offices, organizational and methodological offices, and internal audit services) and 25 general practitioners. Conclusions: The following functional indicators of the medical and organizational effectiveness of the introduction of information systems in polyclinics were highlighted: first, improvement of administrative control, followed in descending order by registration and movement of medical documentation, statistical reporting and process results, and the cost of employees' working time. There has been no reduction in financial costs, namely in terms of the costs of copying, delivery of information in paper form, technical equipment, and paper.

Critical Hazard Factors in the Risk Assessments of Industrial Robots: Causal Analysis and Case Studies

  • Lee, Kangdon;Shin, Jaeho;Lim, Jae-Yong
    • Safety and Health at Work
    • /
    • v.12 no.4
    • /
    • pp.496-504
    • /
    • 2021
  • Background: With the increasing demand for industrial robots and the "noncontact" trend, it is an appropriate point in time to examine whether risk assessments conducted for robot operations are performed effectively to identify and eliminate the risks of injury or harm to operators. This study discusses why robot accidents resulting in harm to operators occur repetitively despite implementing control measures and proposes corrective actions for risk assessments. Methods: This study collected 369 operator-injured robot accidents in Korea over the last decade and reconstructed them into the mechanism of injury, work being undertaken, and bodily location of the injury. Then, through the techniques of Systematic Cause Analysis Technique (SCAT) and Root Cause Analysis (RCA), this study analyzed the root and direct causes of robot accidents that had occurred. Causes identified included physical hazards and complex combinations of hazards, such as psychological, organizational, and systematic errors. The requirements of risk assessments regarding robot operations were examined, and three case studies of robot-involved tasks were investigated. The three assessments presented were: camera module processing, electrical discharge machining, and a panel-flipping robot installation. Results: After conducting RCA and comparing the three assessments, it was found that two-thirds of injury-occurring from robot accidents, causative factors included psychological and personal traits of robot operators. However, there were no evaluations of the identifications of personal aspects in the three assessment cases. Conclusion: Therefore, it was concluded that personal factors of operators, which had been overlooked in risk assessments so far, need to be included in future risk assessments on robot operations.

Efficient Application of Westgard Multi-Rules and Quality Control Implementation Improvement (Westgard Multi-Rules의 효율적 적용과 조치사항의 개선)

  • Jung, Heung Soo;Oh, Youn Jung;Bae, Jin Soo;Baek, Jin Young;Hwang, Bo ra;Shin, Yong Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.60-64
    • /
    • 2017
  • Purpose Westgard multi-rules application based on test quality improvement and commercialized international standard has been widely used in quality control. However, it is difficult to applicate the Westgard multi-rules in nuclear medicine in vitro tests due to the larger sample sizes and the simultaneous measurement of quality control material and patient sample. This study investigated the usefulness of Westgard multi-rules application in nuclear medicine in vitro tests. Materials and Methods A total of 282 systematic error multi-rules (22s, 101s) recorded in the samsung medical center computer system from January 2013 to June 2016 along with 117 cases of corrective measure record was analyzed. The Quality control implementation is recorded in Hospital information system were divided into 4 high-level areas including quality control material error, experimental procedural error, Kit lot number management error, and others. To prevent quality control material error, the existing method that each staff used their own method was changed. The staff who in charge of managing the quality control material was designated and daily consumption amount of every test was strictly controlled by one person. To prevent other errors, every test step was standardized so that the entire test procedures are identically implemented. Results The total quality control implementation was 117 cases; As a result, 62 quality control material errors were 62 cases, experimental process errors were 24 cases, Kit lot number control errors were 18 cases, and other errors were 13 cases. The quality control material error was corrected and could be used fresh materials within 2 days after thawing. The cases of systemic error were decreased to causes as quality control material error. The quality control materials were reduced above 10 vials to a monthly average. In addition, these errors of experimental processing and Kit lot number were improved by test standardization. Consequently, the cases of 101s and 22s in systematic error rules decreased at least 2 cases to a monthly average. Conclusion To confirm of systematic error through multi-rules application quickly, it is necessary to base on management of the QC material, target values and standard deviation. Moreover, in the event of a systematic error, it was found important to record measures based on test cause analysis. The experiment results are expected to contribute to internal quality control improvement and prompt and accurate result reporting through error recording and causal analysis based on Westgard multi-rules analysis.

  • PDF

The Effectiveness of Explicit Form-Focused Instruction in Teaching the Schwa /ə/ (영어 약모음 /ə/ 교수에 있어서 명시적 Form-Focused Instruction의 효과 연구)

  • Lee, Yunhyun
    • The Journal of the Korea Contents Association
    • /
    • v.20 no.8
    • /
    • pp.101-113
    • /
    • 2020
  • This study aimed to explore how effective explicit form-focused instruction (FFI) is in teaching the schwa vowel /ə/ to EFL students in a classroom setting. The participants were 25 female high school students, who were divided into the experimental group (n=13) and the control group (n=12). One female American also participated in the study for a speech sample as a reference. The treatment, which involves shadowing model pronunciation by the researcher and a free text-to-speech software and the researcher's feedback in a private session, was given to the control group over a month and a half. The speech samples, for which the participants read the 14 polysyllabic stimulus words followed by the sentences containing the words, were collected before and after the treatment. The paired-samples t test and non-parametric Wilcoxon signed-rank test were used for analysis. The results showed that the participants of the experimental group in the post-test reduced the duration of the schwa by around 40 percent compared to the pre-test. However, little effect was found in approximating the participants' distribution patterns of /ə/ measured by the F1/F2 formant frequencies to the reference point, which was 539 Hz (F1) by 1797 Hz (F2). The findings of this study suggest that explicit FFI with multiple repetitions and corrective feedback is partly effective in teaching pronunciation.

Features and Cost Reduction Effect of High Pressure LNG Pipeline Network (고압 LNG 배관망의 특성 및 비용절감 효과)

  • Kim, Ho-Yeon;Hong, Young-Soo;Noh, Joo-Young;Eom, Yun-Seong;Kim, Cheol-Man
    • Journal of Energy Engineering
    • /
    • v.17 no.3
    • /
    • pp.139-144
    • /
    • 2008
  • Recently due to march as the high oil price, It is necessary for Korea to grope a plan, which is to increase the energy efficiency of existing facilities as well as to develop overseas gas and oil resources. With this point, this work carried out to approach the high pressure LNG pipeline network of Inchon receiving terminal with Newton method as corrective flowrate. We found that the high pressure network mainly depends on FCVs(Flow Control Valves). The high pressure pump showed the maximum efficiency at the FCVs of 50% opening and could discharge LNG only above the LNG head of 1,500m from a system curve obtained. The operating cost of pumps was estimated from their operating points. We compared the operating cost under normal operation with the operating cost under maximum efficiency. Especially, we obtained the day savings of a year as wells as the hour savings of a day. From the results, the high pressure network win be able to reduce the operating cost of 138 million wons in a year. This means that a pump can reduce the operating cost of 9,823 thousands won. Consequently, this work could find the operating features of the pumps under the complicated high pressure LNG network and the savings effect of the pump operating cost. Also, the results will be able to macroscopically contribute the heightening of national energy competitiveness as well as to microscopically contribute the future effective operation of LNG receiving terminal.

Building practical treatment protocol by comparing the effect of adjustment between Thompson Terminal Technique and Exercise in malpositioned pelvic which induces imbalance of body (골반변위에 따른 신체 불균형에 대한 톰슨터미널테크닉과 운동요법의 교정 효과비교분석을 통한 임상치료프로토콜의 구성)

  • Park, Joon-Ki;Choi, Eun-Seok;Kim, Min-Jung;Lee, Man-Su;Lee, Min-Sun
    • Journal of Digital Convergence
    • /
    • v.14 no.5
    • /
    • pp.445-457
    • /
    • 2016
  • The purpose of the study is to provide frame work of efficient diagnostic and treatment protocol for the people with malpositioned pelvic which causes imbalance of body. Study subjects were grouped as experimental, comparison and control group. Each group consisted of five men and five women randomly assigned. Experimental group was to be tested with Thompson Terminal Technique, its corrective effect and the effect of maintaining the treatment. There were 43.01%p difference in effectiveness of the applied technique between Thompson Terminal Technique and Muscle Energy Technique. It indicates that Thompson Terminal Technique is more effective in treating pelvic misalignment than Muscle Energy Technique. As a result, the use of chiropractic and resistance exercises is proven to be effective for treating the imbalance of body. Also, to maximize the effect of treatment, it is preferable to apply Muscle Energy Technique after applying the Thompson Terminal Technique.