• 제목/요약/키워드: Corporation performance

검색결과 1,793건 처리시간 0.028초

Embedded micro processor를 이용한 저항용접기용 SCR 위상제어장치 개발 (Development of SCR Phase Controller of SPOT Welder using an Embedded u-Processor)

  • 이영준;최영준;최용범;양항준;홍순욱;이학성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2578-2580
    • /
    • 1999
  • In this paper, an embedded micro processor based resistance spot welding controller is introduced which has been recently developed by Hyosung Co. Ltd. The performance of rapid and constant high current control is tested experimentally. This paper shows configurations of measuring system for high current and realtime RMS conversion techniques of sampled discrete data. A digital proportional control is adopted for this system and the result shows that this new product is working well at wide range of welding current and the performance is improved compared with some other commercially available controllers that are widely used in our industries. User friendly MMI system and a computer network system to monitor each welding processes are also presented.

  • PDF

A Study on DVR Control for Unbalanced Voltage Compensation

  • Jung Hong-Ju;Suh In-Young;Kim Byung-Seob;Kim Rae-Young;Choi See-Young
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.803-807
    • /
    • 2001
  • This paper presents a new control scheme for a DVR (Dynamic Voltage Restorer) system consisting of series voltage source PWM converters. To control the negative sequence components of the source, it is necessary to detect the negative sequence components. Generally, a filtering process is used which has some undesirable effects. This paper suggests a new method for separating positive and negative sequences components. This control system is designed using differential controllers and digital filters. The positive and negative sequences are extracted and controlled individually. The performance of the presented controller and scheme are confirmed through simulation and actual experiment with a 2.5kVA prototype DVR system.

  • PDF

설비 모델링 기술을 이용한 발전성능평가 시스템 구성방안 연구 (Development of Power Performance Evaluation System using Modeling Technology)

  • 이지훈;이인태;정남준;배중석;안영모
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제4권2호
    • /
    • pp.81-88
    • /
    • 2018
  • 발전소의 성능을 효율적으로 관리 및 유지하기 위한 발전소 성능평가는 매우 중요한 절차이다. 하지만 기존의 성능평가 방식은 엑셀 기반의 수작업 방식이다 보니 준비절차가 복잡하고, 범용성이 떨어지는 문제가 있었다. 이에 본 논문에서는 기존 성능평가 시스템의 문제점을 분석하고, 설비를 효과적으로 모델링하고 누락된 물성치를 계산하며, 이를 바탕으로 자동 지표계산을 수행하는 설비 모델러를 통해 성능평가의 범용성, 효율성 및 정확성을 높이는 방법을 기술하고자 한다.

미생물 혼입 자기치유 콘크리트의 균열 치유성능 및 내구성능 (Crack-healing and durability performance of self-healing concrete with microbial admixture)

  • 추인엽;우상균;이병재;이윤;이효섭
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제7권2호
    • /
    • pp.295-299
    • /
    • 2021
  • Recently, interest in maintenance has been increasing due to the enlargement and aging of infra structures. Therefore, a new paradigm is required to secure and improve the durability of structures differentiated from the past. Accordingly, research on smart concrete incorporating the concept of self-healing into concrete is being actively conducted. In this study, the crack healing performance and durability performance of self-healing concrete applied with a hydrogel containing biomineral-forming microorganisms were evaluated. As a result of evaluating the dispersion of the hydrogel in concrete, it was confirmed that the hydrogel was well distributed in concrete matrix with a dispersion coefficient of 0.35 to 0.46. The crack healing performance evaluation was verified by a water permeability test, and showed a recovery rate of 95% or more at the age of 28 days, confirming the applicability of self-healing concrete. The durability performance of self-healing concrete was evaluated in terms of resistance to penetration of chloride ion and freezing and thawing. Regardless of the mixing of the hydrogel, the same level of durability performance was shown for various compressive strength level. Therefore, it was confirmed that the microbial admixture did not affect concrete durability. In the future, long-term crack healing performance and durability verification studies should be supplemented.

Performance Prediction of a Combined Heat and Power Plant Considering the Effect of Various Gas Fuels

  • 주용진;김미영;박세익;서동균
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제3권2호
    • /
    • pp.133-140
    • /
    • 2017
  • The performance prediction software developed in this paper is a process analysis tool that enables one to foretell the behavior of processes when certain conditions of operation are altered. The immediate objective of this research is to predict the process characteristics of combined heat and power plant under varying operating conditions. A cogeneration virtual power plant that mimics the mechanical performance of the actual plant was constructed and the performance of the power plant was predicted in the following varying atmospheric conditions: temperature, pressure and humidity. This resulted in a positive outcome where the performance of the power plant under changing conditions were correctly predicted as well as the calorific value of low calorific gas fuel such as shale gas and PNG. The performance prediction tool can detect the operation characteristics of the power plant through the performance index analysis and thus propose the operation method taking into consideration the changes in environmental conditions.

On the performance of Multi-Valued Image Entropy Coding for LCD source drivers

  • Sasaki, Hisashi;Arai, Tooru;Hachiuma, Masayuki;Masuko, Akira;Taguchi, Takashi
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.1240-1243
    • /
    • 2004
  • Multi-Valued Image Entropy Coding (MVIEC) is a new class of joint source channel coding, which reduces both input-width (1/4) and average current (0.36-1.3) for LCD source drivers. This paper describes the detail results on MVIEC for several image sets in order to verify the practical performance.

  • PDF

배전 선로 부하예측 모델의 신뢰성 평가를 위한 비교 검증 시스템 (Development of Comparative Verification System for Reliability Evaluation of Distribution Line Load Prediction Model)

  • Lee, Haesung;Lee, Byung-Sung;Moon, Sang-Keun;Kim, Junhyuk;Lee, Hyeseon
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제7권1호
    • /
    • pp.115-123
    • /
    • 2021
  • Through machine learning-based load prediction, it is possible to prevent excessive power generation or unnecessary economic investment by estimating the appropriate amount of facility investment in consideration of the load that will increase in the future or providing basic data for policy establishment to distribute the maximum load. However, in order to secure the reliability of the developed load prediction model in the field, the performance comparison verification between the distribution line load prediction models must be preceded, but a comparative performance verification system between the distribution line load prediction models has not yet been established. As a result, it is not possible to accurately determine the performance excellence of the load prediction model because it is not possible to easily determine the likelihood between the load prediction models. In this paper, we developed a reliability verification system for load prediction models including a method of comparing and verifying the performance reliability between machine learning-based load prediction models that were not previously considered, verification process, and verification result visualization methods. Through the developed load prediction model reliability verification system, the objectivity of the load prediction model performance verification can be improved, and the field application utilization of an excellent load prediction model can be increased.

Surface Densification Coupled with Higher Density Processes Targeting High-performance Gearing

  • Hanejko, Francis;Rawlings, Arthur;King, Patrick;Poszmik, George
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part2
    • /
    • pp.738-739
    • /
    • 2006
  • This paper will describe a powder and processing method that facilitates single press-single sintered densities approaching $7.5g/cm^3$. At this sintered density, mechanical properties of the powder metal (P/M) component are significantly improved over current P/M technologies and begin to approach the performance of wrought steels. High performance gears have the added requirement of rolling contact fatigue durability that is dependent upon localized density and thermal processing. Combining high density processing of engineered P/M materials with selective surface densification enables powder metal components to achieve rolling contact fatigue durability and mechanical property performance that satisfy the performance requirements of many high strength automotive transmission gears. Data will be presented that document P/M part performance in comparison to conventional wrought steel grades.

  • PDF

수소연료전지자동차의 충돌시 절연성능 평가방법에 관한 고찰 (Study on the Evaluation Method of Electrical Isolation Property for Hydrogen Fuel Cell Vehicle in Post Crash)

  • 이기연;길형준;김동욱;김동우;강대철
    • 한국수소및신에너지학회논문집
    • /
    • 제23권6호
    • /
    • pp.612-618
    • /
    • 2012
  • In this paper, in order to prevent electric shock of high voltage system of HFCV after crash test, insulation performance measurement methods were studied. Under conditions of in-use, insulation performance tests can be divided into measurement method using the vehicle's own RESS as DC voltage source and measurement method using DC voltage from off-vehicle sources. However, these tests can not be applied after a post-crash because parts of high voltage system cover should be removed, and insulation performance can be influenced during these tests. Therefore, we proposed post-crash insulation performance test methods for preventing electric shock through problem analysis of previous post-crash insulation performance tests. Also, test equipment which can measure voltage absence and total energy was developed. We verified performance of the equipment through experiments with vehicle test.