• 제목/요약/키워드: Corona-discharge

검색결과 475건 처리시간 0.046초

Development of AC Transmassion Line Audible Noise Prediction Formulas Using Evolutionary Computations

  • Yang, Kwang-Ho;Park, June-Ho;Hwang, Gi-Hyun;Kim, Jeong-Boo
    • Journal of Electrical Engineering and information Science
    • /
    • 제2권6호
    • /
    • pp.116-122
    • /
    • 1997
  • The audible noise produced by corona discharge in high voltage transmission lines is the most important line design consideration. In this paper, more accurate and useful formulas for predicting the A-weighted audible noise during heavy and light rain in alternative current (AC) transmission lines are proposed through comparison with the existing formulas. The proposed formulas are developed by the applications of evolutionary computations (ECs) to audible noise data base from long-term measurement.

  • PDF

전기집진장치의 코로나 전류 발생 전극 제작에 따른 추타력 비교에 관한 연구 (The Study of Comparison on Rapping Force on Generation of Corona Discharge Electrode of Electrostatic Precipitator)

  • 이강욱;박정호;장성호;임우택;서정민
    • 한국환경과학회지
    • /
    • 제26권2호
    • /
    • pp.231-238
    • /
    • 2017
  • Rapid industrial development has led to a serious problem of pollution in the industrial sector. With the increasing social need for environmental protection, research on air pollution prevention equipment for reducing pollutants in industrial processes is actively being undertaken. The deterioration of existent, installed facilities, their increased emission rates, and the strengthening of the effluent quality standards make complying with permissible emission standards difficult. In fact, installing new electric precipitators or complementing existent facilities is inevitable. The expansion and complementation of the installed electrical precipitators have led to improvements in dust collection efficiency, shorter working times, and lower costs. Because of its easy installation and simple manufacturing process, the production method with the discharge electrode of an electric precipitator is widely used. The following conclusions were reached by classifying discharge electrodes into four types based on the production method and mutually comparing them by their dust collection efficiency. None of the four types used in this study were damaged by impact. However, we were able to confirm some strain from the compression sites of both type A and type B. Both type B and type C are expected to have greater dust collection efficiencies than the other models due to their large vibration transmissibility. Moreover, the high vibrational energy is expected to cause rapping damage during its operation. Particularly, in the case of type B, some of the strain was found at the end of the compression site. The coupling schemes of both type C and type D are out of vibration transmissibility. On the other hand, the ability to maintain straightness and solidity of the side is regarded as outstanding and stable. Type D has outstanding on-site workability, considering the presence of locking, structural stability, and work conditions. From these experiments, we determined that type C is the most ideal connection method of discharge electrode, considering its construction period of renovation. Type C is inferior to type D with regard to on-site workability. However, type C has outstanding dedusting transmission with regard to the straightness, solidity maintenance, and vibration of shearing stress.

Electron Density and Electron Temperature in Atmospheric Pressure Microplasma

  • Tran, T.H.;Kim, J.H.;Seong, D.J.;Jeong, J.R.;You, S.J.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.152-152
    • /
    • 2012
  • In this work we measured electron temperature and electron density of a microplasma by optical emission spectroscopy. The plasma is generated from a small discharge gap of a microwave parallel stripline resonator (MPSR) in Helium at atmospheric pressure. The microwave power supplied for this plasma source from 0.5 to 5 watts at a frequency close to 800 MHz. The electron temperature and electron density were estimated through Collisional-radiative model combined with Corona-equilibrium model. The results show that the electron density and temperature of this plasma in the case small discharge gap width are higher than that in larger gap width. The diagnostic techniques and associated challenges will be presented and discussed.

  • PDF

RTV 실리콘 고무 코팅재의 표면전하 축적이 발수성에 미치는 영향 (Effect of Accumulated charges on Surface Hydrophobicity of RTV Silicone Rubber)

  • 연복희;허창수;조한구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.597-600
    • /
    • 2001
  • In this paper, we evaluated the effect of accumulated charges on hydrophobicity of room temperature vulcanized(RTV) silicone rubber, which could improve the contamination performance of porcelain insulators, with uv radiation time. Outdoor insulating material could be charged by the corona discharge on field intensified area of insulator and discharge between the water drops. In addition, we performed the accelerated uv radiation on samples and investigated the change of charging decay with time. In this results, it is found that silica-like structure on the surface of RTV silicone rubber was formed by uv treatments and this layer have the characteristic of retaining the charges on surface for a long time. These charges have effects on its hydrophobicity and so adversely effects on contamination performance. Based on our results, we discussed the other degradation mechanism with well known ones.

  • PDF

원통형 플라즈마 반응기에서 $NO_x$ 제거에 미치는 슬러지의 촉매효과 (Catalistic effect of sludge on $NO_x$ removal in cylinder type reactor)

  • 박재윤;이경호;박상현;김형만;김종석;하현진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1777-1779
    • /
    • 2001
  • In this experiment, an attempt to use the sludge pellets as catalyst for NO removal from simulated gas is experimentally investigated by using cylinder type reactor. An experimental investigation has been conducted for NO concentration of 50[ppm], 100[ppm], 200[ppm] balanced with air. a gas flow rate of 5[1/min]. Cylinder type reactor is at upstream of system for corona discharge and packed bed type reactor filled with sludge pellets ate put at downstream of Cylinder type reactor for catalystic effect. And AC voltage to discharge the gases was supplied. In the result, NO removal with magnetic field is higher than that without magnetic field, when packed-bed reactor with sludge pellet is installed at downstream of cylinder reactor NO, $NO_2$ removal rate increased and $O_3$ is not generated.

  • PDF

저온 플라즈마와 첨가제를 이용한 NOx 제거실험 및 수치해석 (The Study of NOx Removal Experiment and Numerical Analysis Modeling using Chemical Addition with Non-thermal Plasma)

  • 채재우;문승일;김관영;김상우;박용광;이창민
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.720-725
    • /
    • 2000
  • To remove harmful gases from combustion exhaust gases. fundamental study on NOx removal using pulse corona discharge has been performed through experiments and simulations. The energy consumption should be decreased in order to apply non-thermal plasma technology to industry process. This work summarized the effects of $H_2O$ and Hydrocarbon additive in NOx removal efficiency. The Radical program is used to simulate high voltage discharge and the process of NOx removal. At last, experimental results were compared with simulation results to verify the reliability of this program.

  • PDF

운전중인 변압기의 부분방전 측정기법 적용 (Application of the Partial Discharge Measuring Method in Operating Transformer)

  • 권동진;최인혁;정길조
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2000년도 학술대회논문집
    • /
    • pp.94-98
    • /
    • 2000
  • This paper describes an application of the partial discharge measuring method in operating transformer. In the operating transformer, the useful PD signal may be superimposed by radio intereference voltage and impulse shaped noise signals generated by external corona or power electronics. In this paper, initial investigations after connecting the PD measuring system to the terminals of the measuring impedance showed a very high noise level of 3,700pC due to sinusoidal interferences. In order to reject these noises, this paper applied RIV and band-pass filters and noise gating method. The resulting measuring sensitivity was improved from 3,700pC to 160pC.

  • PDF

포켈스 효과를 이용한 불평등 전계 측정 (A possible application of the nonuniform electric field measurement using Pockets effect)

  • 강원종;임윤석;최재옥;장용무;구자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.513-515
    • /
    • 2000
  • In this paper, new Partial Discharge (PD) detection technique using Pockels-cell was proposed. For this purpose, PD was generated from needle-plane electrode in air and detected by optical measuring system using Pockets cell, based on Mach-Zehnder interferometer, consisting of He-Ne laser, single mode optical fiber, 50/50 beam splitter and photo detector. We show the characteristic of the proto-type sensor for the corona discharge.

  • PDF