• Title/Summary/Keyword: Corona Charger

Search Result 15, Processing Time 0.016 seconds

Design and Evaluation of a High Concentration, High Penetration Unipolar Corona Ionizer for Electrostatic Discharge and Aerosol Charging

  • Intra, Panich;Tippayawong, Nakorn
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.5
    • /
    • pp.1175-1181
    • /
    • 2013
  • The aim of this paper is to design and evaluate a high concentration, high penetration unipolar corona ionizer. The electrostatic characteristics in terms of voltage-current relationships of the present ionizer in the discharge zones for positive and negative coronas were discussed. Using ion current measurement, the concentration and penetration of ions were evaluated at corona voltages across the needle electrodes between 1 and 4 kV, flow rates between 1 and 5 L/min, and an operating pressure of 1 atm. In the discharge zone of the ionizer, the highest ion concentrations were found to be about $1.71{\times}10^{14}$ and $5.09{\times}10^{14}\;ions/m^3$ for positive and negative coronas, respectively. At the outlet of the ionizer, it was found that the highest ion concentration was about $1.95{\times}10^{13}$ and $1.91{\times}10^{13}\;ions/m^3$ for positive and negative coronas, respectively. The highest ion penetration for positive and negative coronas through the ionizer was found to be about 98 % and 33 %, respectively. The $N_it$ product for positive and negative coronas was also found to $1.28{\times}10^{13}$ and $7.43{\times}10^{13}\;ions/m^3s$, respectively. From the findings, this ionizer proved to be particularly useful as an aerosol charger for positive and negative charge before the detector in an electrical aerosol detector.

Design and Performance Evaluation of a Portable 3-Stage Electrical Low Pressure Impactor(P-ELI) for Measurements of Submicron Aerosol (미세입자 측정용 간이형 3단 전기적 저압 임펙터의 설계 및 성능평가)

  • Cho, Myung-Hoon;Ji, Jun-Ho;Park, Dong-Ho;Bae, Gwi-Nam;Hwang, Jung-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.7
    • /
    • pp.826-833
    • /
    • 2004
  • Cascade impactors are widely used to collect size classified aerosol. A major disadvantage of this instrument is the required long sampling time. Electrical low pressure impactor has been developed to overcome this disadvantage and to achieve real-time measurements on the particle size distribution. The instrument consists primarily of a corona charger, low pressure cascade impactor and multi channel electrometer. We designed and evaluated the performance of a potable 3-stage low pressure impactor using an electrical method. For the calibration of the impactor, monodispersed particles were generated using evaporation-condensation method followed by electrostatic classification using a DMA(Differential Mobility Analyzer). The collection efficiency curves of the stages can be determined by analysing the fraction of particles collected by each stage.

A Study on collection efficiency of two-stage electrostatic precipitator using PET-coated non-metallic electrode with respect to relative humidity (PET 코팅된 비금속 집진판을 사용한 2단 전기집진기의 상대습도에 따른 집진효율 연구)

  • Haneol Lee;Gwangtaek Lee;So-Hee An;Ye Won Park;Gunhee Lee;Kee Jung Hong;Inyong Park;Sang Bok Kim;Daehoon Park;Yeawan Lee;Dong-Keun Song;Yong-Jin Kim;Bangwoo Han;Hak-Joon Kim
    • Particle and aerosol research
    • /
    • v.19 no.3
    • /
    • pp.53-62
    • /
    • 2023
  • This study compared the collection efficiency of a two-stage electrostatic precipitator (ESP) with a lightweight PET film-coated carbon electrode collector plate, depending on the relative humidity of the exhaust gas and the applied voltage to the pre-charger. It was confirmed that the onset voltage at which corona discharge occurs decreases and the discharge current decreases at the same voltage as the relative humidity increases. On the other hand, even though there was almost no change in the diameter of the particles generated depending on the relative humidity, the efficiency was higher at the same voltage as the relative humidity increased. In addition, by applying a two-stage ESP structure, the collection efficiency was higher than that of a single-stage electrostatic precipitator under the same conditions. The ESP using the carbon electrode coated with PET film used in this study is expected to be effective in various aspects such as weight and in the current situation where environmental regulations are rapidly tightening.

Effect of Performance of Aerosol Charge Neutralizers on the Measurement of Highly Charged Particles Using a SMPS (에어로졸 중화기의 성능이 고하전 입자의 크기분포 측정에 미치는 영향)

  • Ji, Jun-Ho;Bae, Swi-Nam;Hwang, Jung-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.10
    • /
    • pp.1498-1507
    • /
    • 2003
  • A SMPS(scanning mobility particle sizer) system measures the number size distribution of particles using electrical mobility detection technique. An aerosol charge neutralizer, which is a component of the SMPS, is a bipolar charger using a radioactive source to apply an equilibrium charge distribution to aerosols of unknown charge distribution. However, the performance of aerosol charge neutralizers is not well known, especially for highly charged particles. In this study, the effect of the particle charging characteristics of two aerosol charge neutralizers on the measurement using a SMPS system was experimentally investigated for highly charged polydisperse particles. One has radioactive source of $^{85}$ Kr (beta source, 2 mCi) and the other has $^{210}$ Po (alpha source, 0.5 mCi). The air flow rate passing through each aerosol charge neutralizer was changed from 0.3 to 3.0 L/min. The results show that the non-equilibrium character in particle charge distribution appears as the air flow rate increases although the particle number concentration is relatively low in the range of 1.5∼2x10$^{6}$ particles/㎤. The low neutralizing efficiency of the $^{85}$ Kr aerosol charge neutralizer for highly charged particles can cause to bring an artifact in the measurement using a SMPS system. However, the performance of the $^{210}$ Po aerosol charge neutralizer is insensitive to the air flow rate.

Nano Particle Charging Characteristics of Aerosol Charge Neutralizers (에어로졸 중화기의 나노 입자 하전 특성)

  • Ji, Jun-Ho;Bae, Swi-Nam;Hwang, Jung-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.10
    • /
    • pp.1489-1497
    • /
    • 2003
  • Aerosol charge neutralizers with various radioactive sources have been used to apply an equilibrium charge distribution to aerosols of unknown charge distribution. However, the performance of aerosol charge neutralizers is not well known, especially for highly charged particles. Measurements of highly charged particles are needed in air cleaning devices, e.g. electrostatic precipitator, bag filter with a pre-charger, and electrical cyclone. In this study, the particle charging characteristics of two different aerosol charge neutralizers were experimentally investigated for singly charged monodisperse particles and highly charged polydisperse particles. One has radioactive source of $^{85}$ Kr (beta source, 2 mCi) and the other has $^{210}$ Po (alpha source, 0,5 mCi). The air flow rate passing through each aerosol charge neutralizer was changed from 0.2 to 2.5 L/min. The results show that the charge distribution of singly charged monodisperse particles passing through the $^{85}$ Kr aerosol charge neutralizer is well agreed with the Boltzmann equilibrium charge distribution at an air flow rate of 0.3 L/min, However, it deviates from the equilibrium charge distribution when the air flow rates are 0.6, 1,0, and 1,5 L/min, On the other hands, the effect of air flow rate is insignificant for the $^{210}$ Po aerosol charge neutralizer. The non-equilibrium character in charge distribution of highly charged polydisperse particles passing through the $^{85}$ Kr aerosol charge neutralizer greatly depends on the air flow rate, however it is insensitive to the air flow rate for the $^{210}$ Po aerosol charge neutralizer.