• Title/Summary/Keyword: Corneal thickness

Search Result 52, Processing Time 0.026 seconds

Study of Ocular Optical Components (안구의 광학적 구조에 관한 연구)

  • Seo, Y.W.;Choe, Y.J.
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.2
    • /
    • pp.139-144
    • /
    • 2000
  • In this study, anterior corneal radius of curvature in korean subjects aged between 16 to 79 year-olds were measured using a keratometer. Refractive power was also measured without cyloplegia. A-mode Ultrasonography was used to measure anterior chamber depth, crystalline lens thickness, vitreous chamber depth & axial length. Measurements of anterior chamber depth of subjects in their 20s were between 3.0 mm & 4.0 mm, 70s age group were between 2 mm & 3.50 mm, showing a decrease with age. Crystalline lens thickness of 20s age group was 2.64 mm while 70s age group was 4.62 mm showing an increase with age. Vitreous chamber depth, unaffected by age, was about 17 mm. Axial length was 24.47 mm in subjects below 40s age groups decreasing to 24.11 mm in above 40s age groups. Corneal radius of curvature was 7.79 mm and 7.72 mm in younger and older age groups respectively, showing a decrease with age.

  • PDF

Evaluation of Oxygen Permeability of Soft Contact Lenses Based on Thickness (두께 기준에 따른 소프트 콘택트렌즈의 산소투과성 평가)

  • Yu, Dong-Sik;Moon, Byeong-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.8
    • /
    • pp.2157-2163
    • /
    • 2009
  • The oxygen permeability of a soft contact lens is an important parameter for determining corneal health when considering the physiological response of the eye. The aim of this study is to evaluate the oxygen permeability of soft contact lenses based on thickness, using the polarographic method. The thickness of lens was measured using contact and non-contact method. To assess accuracy and reliability, the Bland-Altman plot was used. The reliability was high for the oxygen permeability based on center thickness measured by contact method, whereas the accuracy was high for the oxygen permeability based on center thickness measured by non-contact method. These results indicate that the permeability characteristics were variable according to the measurement and criteria of thickness of soft contact lenses and the measurement of soft contact lenses by non-contact method was more reasonable. Thus, contact lens practitioners should consider some basic differences between methodologies when interpreting or quoting oxygen performance data.

Comparison of the Clinical Effect after Wearing Conventional and 2-Weeks Cosmetic Tinted Contact Lens (일반 미용 칼라 콘택트렌즈와 2주 교체용 미용 칼라 콘택트렌즈 착용에 따른 임상성능 비교)

  • Kim, Chang Jin;Kim, Jai-Min;Kim, Hyun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.2
    • /
    • pp.15-26
    • /
    • 2009
  • Purpose: To compare and analyze the ocular changes after wearing conventional and 2-weeks cosmetic tinted contact lens, which were made of different material and fabrication method. Methods: Thirty five university students, age of twenties, participated in this study. With daily wearing schedule, they had worn temporary cosmetic tinted lens for 2 weeks and conventional tinted lens for two month in their right and left eye, respectively. Subjective symptoms and objective signs were graded by using CCLRU scales and corneal thickness were measured after 1 day and 2 months wearing, and under or over 5 hours wearing in a day, respectively. Results: Major subjective symptoms found in the student wearing cosmetic tinted contact lens for a 1 day and 2 months were dryness, redness, foreign body sensation and itchiness. It was also found that those symptoms were more severe in left eye (conventional cosmetic tinted contact lens) than right eye (2-weeks cosmetic tinted contact lens). However, symptoms of redness in both eyes showed statistically significant difference in the case of 1 day and 2 months wearing and under or over 5 hours wearing in a day (p=0.000). After 2 months wearing, left eye with conventional cosmetic tinted contact lens showed limbal redness (p=0.000) and bulbar conjunctival redness (p=0.012) with statistically significance, whereas there was no significant difference in both eyes before lens wear. Left eye showed statistically significant changes in all objective signs, but right eye showed palpebral conjunctival redness, corneal staining and conjunctival staining. Therefore, it was concluded that conventional cosmetic tinted contact lens may be more effective on ocular changes after wearing of lens. A statistically significant changes in both eyes after wearing lens were found that corneal thickness increased about $5{\mu}m$ (p=0.001) in right eye whereas $7{\mu}m$ (p=0.004) in left eye. Conclusions: A statistically significant number of participants in this study preferred to wearing of high Dk/t temporary cosmetic tinted contact lens made by sandwich method which resulted in less ocular changes and may give more healthy and safe ocular conditions.

  • PDF

The Clinical Study on the Visual Acuity and Cornea of ez-NANOsence II RGP Contact Lens (ez NANOsence II RGP 콘택트렌즈의 시력과 각막에 미치는 임상적 연구)

  • Kim, Douk-Hoon;Bae, Han-Young;Han, Mung-Gyo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.4
    • /
    • pp.55-69
    • /
    • 2007
  • The purpose of this study was to perform a clinical test using ez NANOsence II RGP contact lenses for the effects of visual acuity and cornea on subjects with abnormal refraction status. One hundred twenty one adults (twenty nine males, ninety two females, range = 17 to 43, mean = 22.86) were recorded. The subject's history including, the symptoms from previous lens wear, were studied. The subjects were observed, both pre and post lens wear, for any symptoms and signs of change of the eye. The Visual acuity and the binocular status were tested at the far distance using the contact lens. The refraction test was performed on the naked eye using the objective method (Topcon KR-8100, Japan). The Stereopsis test was performed at the near distance after contact lens wear by the Titmus fly (Stereo Optical Co., U.S.A) and TNO (TECH, The netherlands). The contrast sensitivity diagnosis was performed at 1m distance after contact lens wear by the contrast sensitivity chart (pelli-Robertson, USA). The corneal topography was analyzed on the naked eye after lens wear by ORB scan (Bausch Lomb, U.S.A.). The ultra structure of surface on the contact lens was observed using SEM (JMS-5800, Japan). The chemical component's of the contact lens was analyzed by EDS program. The results of this study were as follows: 1. The longer of contact lens wear period, The subjects have acquired the most improved visual function. 2. Subjects had experienced few side effects wearing the contact lenses. 3. The lenses were easy to use by the subjects. 4. The longer of contact lens wear period, the power of cornea had more decrease. but the base curve of cornea had more increase and corneal astigmatism was decrease (p<0.01). Also, the thickness of corneal center was few decrease. 5. Longer periods of using the contact lens showed stereopsis and contrast sensitivity at more normal values. 6 The corneal topographical after lens wear showed most subjects with similar morphology for different wear periods. 7. The surface ultrastructure of the new and used contact lens was the similar fine shape. 8. The chemical component's of in the new and used contact appeared to have similar results. In conclusion, this study showed that the surface ultrastructure and chemical component's of the new and used contact lens are similar. In addition, the subjects had improved the quality of vision and few experienced any side effects during long periods of contact lens wear. Also they have decrease of corneal astigmatism during the long period of lens wear. Our test has showed that the chemical composition and fine structure of contact lens have related to the visual function on contact lens wearer. In this paper, we suggested that ez NANOsence II RGP contact lenses had a moderate effect for correcting vision of abnormal refraction eye.

  • PDF

A Study on the Comparison of Viscoelastic Materials used in Phacoemulsifcation in Dogs and Their Substitute (개의 수정체 유화흡인술에 사용되는 점탄물질들의 비교와 대체물에 관한 연구)

  • 권오경;김완회
    • Journal of Veterinary Clinics
    • /
    • v.15 no.2
    • /
    • pp.364-369
    • /
    • 1998
  • The purposes of the present study were to compare the effects of viscoelastic materials available in phacoemulsification in dogs and to evaluate $ARTZ^{\circledR}$ as their substitute. Six eyes from the healthy adult dogs were used in each group with different viscoelastic materials, $Healon$^{\circledR}, Viscoat^{\circledR}$ and $Occucoat^{\circledR} and ARTZ^{\circledR}$. The phacoemulsification was carried out with surgical micmscope(Leica M65l, Germany) and pbacoemulsiscation gystemGfidek 6000, Japan). $ARTZ^{\circledR}$ had lower pseudoplasocity than other viscoelastics. There was not significant difference in phacotime, rate of posterior capsule rupture, incidence of the intraocular inflammation among the viscoelastic materials. The corneal thickness in all groups was significantly increased in a day after operation and decreased gradually. However $ARTZ$^{\circledR}$ had more time to recover the preoperative thickness than the others. CoBiunctival congestion in the group with $ARTZ^{\circledR}$ was more severe but. there were no postoperative posterior capsule opacity and visual loss. The present study indirated that $ARTZ^{\circledR}$ could be used as viscoelastic material in dogs with respect to the vision after surgery.

  • PDF

A Frequency Domain Analysis of Corneal Deformation by Air Puff (Air puff에 의한 각막 변형의 주파수 영역 분석)

  • Hwang, Ho-Sik;Lee, Byeong Ha;Lee, Chang Su
    • Journal of IKEEE
    • /
    • v.18 no.2
    • /
    • pp.240-247
    • /
    • 2014
  • Intraocular pressure is measured after a cornea air puff by observing biomechanical properties such as thickness or displacement of the cornea. In this paper, we deal with a frequency domain analysis of corneal deformation in the air puff tonometry that is used to diagnose glaucoma or lasik. We distinguish the patient from the normal by measuring the oscillation frequency in the neighborhood of the central cornea section. A binary image was obtained from the video images, and cornea vertical oscillation profile was extracted from the difference between the vertical displacement data and the curve fitting. In terms of Fourier transform, a vibration frequency of 479.2Hz for the patient was obtained as well as more higher 702.8Hz for the normal due to stiffness. Hilbert-Huang transform's empirical mode decomposition generally describes local, nonlinear, and nonstationary data. After the data were decomposed into intrinsic mode functions, a spectrum and power were analysed. Finally, we confirm that the patient has 6 times more higher power ratio for the specific intrinsic mode function between the patient and the normal.

Fabrication of Ex vivo Cornea Model for a Drug Toxicity Evaluation (약물 독성 평가용 생체외 각막 모델 제작 연구)

  • Kim, Seon-Hwa;Park, Sang-Hyug
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.5
    • /
    • pp.143-150
    • /
    • 2019
  • To evaluate the toxicity of ophthalmic drug, the Draize test and Bovine Corneal Opacity and Permeability (BCOP) test commonly used. In Draize test, experimental animals were under stress and pain due to long-term exposure of drug. In addition, regarding physiological functions, animal model is not perfectly reflected a human eye condition. Although some models such as $EpiOcular^{TM}$, HCE model, LabCyte Cornea-Model, and MCTT $HCE^{TM}$ were already presented advanced cornea ex-vivo model to replace animal test. In this sense, cornea tissue structure mimicked ex-vivo toxicity model was fabricated in this study. The corneal epithelial cells (CECs) and keratocytes (CKs) isolated from rabbit eyeball were seeded on non-patterned silk film (n-pSF) and patterned silk film (pSF) at $32,500cells/cm^2$ and $6,500cells/cm^2$. Sequentially, n-pSF and pSF were stacked to mimic a multi-layered stroma structure. The thickness of films was about $15.63{\mu}m$ and the distance of patterns was about $3{\mu}m$. H&E stain was performed to confirm the cell proliferation on silk film. F-actin of CKs was also stained with Phalloidin to observe the cytoskeletal alignment along with patterns of the pSF. In the results, CECs and CKs were shown the good cell attachment on the n-pSF and pSFs. Proliferated cells expressed the specific phenotype of cornea epithelium and stroma. In conclusion, we successfully established the ex-vivo cornea toxicity model to replace the eye irritation tests. In further study, we will set up the human ex-vivo cornea toxicity model and then will evaluate the drug screening efficacy.

The Analysis of the State of Successful Refractive Surgery's Eye (성공적인 굴절교정수술자 안구상태분석에 대한 연구)

  • Jang, Woo-Yeong;Lee, Jeong-Yeong;Park, Jeong-Sik
    • Journal of Korean Clinical Health Science
    • /
    • v.2 no.4
    • /
    • pp.223-230
    • /
    • 2014
  • Purpose. Scheduled calibration of refractive error's have various refractive surgery, and a side effect of post refractive surgery for refractive errors's before refractive surgery, by analyzing the eye condition of the refractive error's good state, it tries to increase the satisfaction of refractive error's refractive surgery. Methods. In response to 60 people preoperative data 20-30 generations of age, were analyzed for eye conditions. Results. IOP, thickness of the cornea, liquid leakage amount inspection, the corneal endothelium inspection, the size of the pupil, have been conducted auto refraction test and showed a numerical value in most normal range. Conclusion. Surgery can be of individual differences of patients, it is difficult to define the full normal range, to the surgery based on the case of this study, the side effects of patients after surgery is expected to be prevention.

Marsupialization of the Nictitating Membrane Cyst Following Cherry Eye Repair in a Dog

  • Kim, Sunhyo;Kang, Seon-mi;Susanti, Lina;Kim, Boyun;Park, Yoonji;Shim, Jaeho;Go, Seokmin;Lee, Eunji;Seo, Kangmoon
    • Journal of Veterinary Clinics
    • /
    • v.37 no.3
    • /
    • pp.149-152
    • /
    • 2020
  • One-year-old male Cocker Spaniel dog was referred for the third eyelid enlargement and inflammation in the left eye (OS). It gradually swelled for 2 weeks after the cherry eye repair by conjunctival mucosa pocket procedure at a private animal clinic. Routine ophthalmic examinations including neuro-ophthalmic examination, Schirmer tear test, intraocular pressure and corneal fluorescein staining were all normal. No lesions were found on slit lamp biomicroscopy and indirect ophthalmoscopy except for third eyelid swelling in the OS. Ultrasonography revealed cystic structure within the OS nictitating membrane. Fluid from the cyst was aspirated and there were no microorganisms or neoplastic changes. Surgical intervention was performed under general anesthesia. On the day of the surgery, there was a deep corneal ulcer in the OS, which had not existed before. Ventral palpebral surface of the third eyelid was incised horizontally to the shaft of the T-shaped hyaline cartilage. And then, a full thickness of the cystic wall was incised and marsupialized. Additionally, a direct suture was performed on the ulcerated cornea. Topical and systemic antibiotics and anti-inflammatory drugs were prescribed. One month after the surgery, the third eyelid swelling and the discharge were improved. Marsupialization of the nictitating membrane cyst relieved the swelling of the third eyelid and inflammation. It could be a simple but effective surgical intervention for the cystic complication of conjunctival mucosa pocket procedure in dogs.

Effects of Base Curve on Fitting with the current Soft Contact Lenses (베이스 커브에 의한 콘택트렌즈 피팅 효과)

  • Choe, Oh Mok;Gang, Myoung Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.2
    • /
    • pp.65-72
    • /
    • 2000
  • The study investigated the effects of base curve radius art the fit of thin, mid-water contact lenses. It was found that central corneal curvature(as measured with the keratometer) was not predictive of the best fitting base curve. Proper lens fit may be the single most important factor that ultimately determines the success of contact lens wear. Comfort, vision, and physiological response are all dependent on the fit of the lens. The percent of optimal fits was highest with the 8.4 mm base curve lens for all three ranges of keratometry values. When fit with the 8.4 mm lens. For most eyes, fitting a flatter lens led to greater decentration, decreased comfort, and no increase in lens movement. The 8.4 mm lens was found to provide on "optimal" fit in over 60% of eyes tested and a fit of "good" or "better" in nearly 90% of eyes tested. Comparisons of different manufactures' lens found that similiar lenses do not always fit in the same way due to subtle design and production differences. Therefore, different products may require different base curve radii to fit the same patient. This is even true when water content, center thickness, and diameter are approximately the same. A praditioner fitting a new patient in this lenses should begin with the 8.4 mm base curve radius.

  • PDF