• Title/Summary/Keyword: Corneal Power

Search Result 52, Processing Time 0.022 seconds

Analysis of Astigmatism in Korean Adults from 20 to 29 Yesrs Old (20세부터 29세까지 한국인 성인 난시 분석)

  • Kim, Douk-Hoon;Park, Sang-Youl
    • Journal of Korean Clinical Health Science
    • /
    • v.9 no.1
    • /
    • pp.1478-1485
    • /
    • 2021
  • Purpose. To analysis of astigmatism in Korean adults from 20 to 29 years old. Methods. From January 2019 to February 2020, one hundred two subjects were performed in refraction test using the Auto-Refractometry. Results. In the type of astigmatism based on refractive error, the male's right eye was 4.26% simple myopic astigmatism and 95.74% complex myopic astigmatism, and the left eye was 2.22% simple myopic astigmatism and 97.78% complex myopic astigmatism. However, in the female's right eye, simple myopic astigmatism was 2.27%, complex myopic astigmatism was 97.73%, and left eye was simple myopic astigmatism was 2.17%, complex myopic astigmatism was 97.83%. The types of astigmatism in men and women similar to other. The mean refractive astigmatism values were -0.922±-0.798 diopter and -0.877±-0.707 diopter for male right and left eye, and -0.765±-0.599 diopter and -0.853±-0.586 diopter for female. On the other hand, the refraction values of the right and left eyes of men and women have statistical significance(p=0.000). The mean power comparative between refractive astigmatism and corneal astigmatism power were -0.186±-0.745 diopter, -1.091±-0.589 diopter in male and -1.140±-0.593 diopter, -1.140±-0.534 diopter in female. Therefore, the mean power values of the refractive astigmatism and corneal astigmatism of men and women were statistical significance(p=0.000). At the 0.75 diopter or more, which can have clinical symptoms of astigmatism power, males have 60.86% and 72.09% of the right and left eyes, and females have 47,64% and 60.10% of the right and left eyes. At 0.75 diopter or more, which can have clinical symptoms of corneal astigmatism power, males have 68.75% and 74% of the right and left eyes, and females have 86.50% and 82.35% of the right and left eyes. In the type of astigmatism axis, both men and women had a high frequency of the rule astigmatism. However, men had a high frequency of against-the-rule astigmatism and women showed a high frequency of oblique astigmatism. Conclusions. In this study, the complex myopic astigmatism and with-the rule astigmatism was the most common of all subjects. However, there was a statistical significance between right and left eyes of all subjects. The corneal astigmatism was higher refractive values in both males and females than refractive astigmatism. This study suggests that the analysis of the astigmatism can provide the useful diagnosis information for the correction of visual acuity.

Refractive Power Changes after Removal of Contact Lenses (콘택트렌즈를 임시 제거한 상태에서의 착용 조건에 따른 굴절력 변화)

  • Cho, Yun-Kyung;Kim, Soo-Woon;Yu, Dong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.279-289
    • /
    • 2013
  • Purpose: To evaluate the changes of refractive power when worn soft contact lenses were temporarily removed. Methods: 91 soft contact lens wearers (15 males and 76 females; total 182 eyes) from 17 to 39 years of age (average: $24{\pm}4.8$ years) were participated. Objective and subjective refraction, and corneal radius were measured at 0, 30, 60 and 90 min after lens removal. The changes in refractive power were evaluated between measurements over time. The other parameters such as types of lenses, fitting and wearing conditions were also assessed. Results: Objective refraction, subjective refraction and corneal radius were significantly changed according to measured time (p<0.0001). A moderate myopic shifts was observed at the beginning (30 min after lens removal) and a slight myopic shift at the late of measurement (60 min to 90 min after lens removal). There are no significant differences between lens types, fitting states, wearing time, wearing days and sleeping time in the previous day. However, there was significant interaction in changes for corneal radius between measuring time and lens type (p=0.017), fitting state (p=0.019), and sleeping time prior to the test (p=0.010). Conclusions: Time to reach refractive and corneal radius stability after contact lens removal revealed at least more than 60 min, regardless of types of lenses, fitting and wearing conditions. Therefore, refraction for correction should be performed after waiting for more than that time as possible.

Study of Ocular Components in Determining the Refractive State of the Eye (굴절이상을 결정하는 안광학 요소에 관한 연구)

  • Seo, Y.W.;Choe, Y.J.
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.1
    • /
    • pp.7-14
    • /
    • 1999
  • The purpose of this study is to evaluate the relationship between ocular components and refractive error for human eye. Ocular components were measured by keratometry, phakometry, and ultrasonography. Refractive error was measured by subjective refraction on 38 subjects aged from 17 to 30. The results were as follows; 1) Refractive error and axial length, vitreous chamber depth, axial length/corneal radius were highly correlated that the correlation coefficients were 0.95, 0.96, 0.95, respectively. 2) Refractive error and corneal radius, corneal power, lens thickness were correlated with the correlation coefficients for 0.60, 0.66, 0.67 respectively. 3) There were no significant correlation between refractive error and corneal thickness.

  • PDF

A Comparison of Refractive Components in Anisometropia and Isometropia (굴절부등안과 동등안의 양안 굴절요소 차이 비교)

  • Shim, Hyun-Seog;Shim, Jun-Beom;Kim, Eun-Suck
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.187-193
    • /
    • 2011
  • Purpose: This study was to compare differences between both eyes in corneal powers, axial lengths, anterior chamber depths in anisometropia and isometropia, and to investigate the relationship between anisometropia and refractive components. Methods: The subject was a total of 83 patients, anisometropia 45 patients (90 eyes) and isometropia 38 patients (76 eyes) from 2.7 to 15.3 years old, prescribed eyeglasses and contact lenses by refraction from July 2010 to August 2010 in Gwangju City B eye clinic. Axial length, anterior chamber depth, corneal curvature, and corneal refractive power were measured using IOL Master. Refractive error was measured using an Auto-refractometer. Results: Anisometropia was a statistically significant difference in axial length, binocular refractive components, refractive error, and axial length, Axial length/corneal radius (AL/CR) ratio showed a statistically significant difference in anisometropia and isometropia. The major cause of anisometropia all 45 subjects was the axial length. Among the refractive components axial length, AL/CR had a strong correlation, but corneal refractive power had no correlation. Anterior chamber depth had a weak correlation. Conclusions: This study found that refractive error was the most axial ametropia caused by the axial length. The main cause of anisometropia was the axial length, but refractive components had a weak correlation.

Photobiomodulation Mediated by Red and Infrared Light: A Study of Its Effectiveness on Corneal Epithelial Cells and Wound Healing (적색 및 적외선 빛을 이용한 Photobiomodulation: 각막상피세포에 대한 효과와 상처 치유에 관한 연구)

  • Sun Hee Ahn;Jae Sung Ahn;Byeongil Lee
    • Korean Journal of Optics and Photonics
    • /
    • v.34 no.2
    • /
    • pp.45-52
    • /
    • 2023
  • In this study, we have investigated the effect of photobiomodulation (PBM) on corneal wound healing, using a low-power light-emitting diode (LED) at different wavelengths. We found that LEDs with wavelengths ranging from 623 to 940 nm had no significant cytotoxic effects on corneal epithelial cells. The effect of PBM on promoting cell migration was analyzed by scratch assay, and it was found that PBM at 623 nm significantly increased cell migration and promoted wound healing. Furthermore, the expression of genes related to cell migration and wound healing was analyzed, and it was found that PBM at 623 nm upregulated the expression of the genes FGF-1 and MMP2, which are known to promote cell proliferation and extracellular matrix degradation. These findings suggest that PBM with low-powered light at specific wavelengths, particularly 623 nm, could be utilized to treat corneal injury.

Study of the cornea characteristics using Oculus Pentacam (Oculus Pentacam을 사용한 각막 특성 분석)

  • Lee, Jeung-Young;Park, Eun-Kyoo
    • Journal of the Korea society of information convergence
    • /
    • v.6 no.1
    • /
    • pp.37-41
    • /
    • 2013
  • In this study, by using the Oculus Pentacam, we analyzed the relationship of corneal front astigmatism corneal and the radius of curvature of the rear face of the 20's to 40's. The vertical radius of curvature were man 7.94mm (${\pm}0.22$), women 7.87mm (${\pm}0.21$), the horizontal radius of the anterior corneal appeared man 7.69mm (${\pm}0.27$), women 7.63mm(${\pm}0.23$). And rear vertical radius of curvature were man 6.52mm(${\pm}0.23$), woman 6.55mm (${\pm}0.22$), the horizontal radius of the anterior corneal appeared man 6.06mm (${\pm}0.24$), woman 6.08mm(${\pm}0.24$). The results of correlation analysis between the radius of corneal posterior surface and the anterior corneal surface, it was found out that there is a significant correlation. In this study, similar results were obtained anterior surface of the cornea, the radius of curvature of the rear surface, the refractive power, and astigmatism, as other papers that have been reported. But in this paper, the cornea thickness was thicker than other previously reported paper.

  • PDF

The Comparative Analysis of Male and Female of Adult on the Base Crve, Power and Astigamtism of the Cornea (각막의 곡율반경, 굴절력, 난시에 대한 성인 남녀의 비교 분석)

  • Chio, Ho Seong;Kim, Douk Hoon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.2
    • /
    • pp.27-31
    • /
    • 2000
  • As the functional test of cornea. The clinical value of keratometric information was important for assessment the curvature of the cornea, the quality of the corneal surface, the stability of the corneal curvature, and the direction of the corneal astigmatism. This study was performed the comparative analysis of male and female of adult on the base curve, power and astigmatism of the Cornea. On the corneal base curve, the male right eye was 7.656 mm in vertical and 7.966 mm in horizontal. But, the male left cornea was 7.714 mm in vertical base curve and 8.026 mm in horizontal base curve. On the other hand, the female right eye cornea was 7.559 mm in vertical base curve and 7.695 mm in horizontal base curve. But, the female left eye cornea was 7.444 mm in vertical base curve and 7.742 mm in horizontal base curve. On the corneal diopter power, the male right eye was 44.063 diopter in vertical and 43.738 diopter in horizontal. But the male left eye was 44.046 diopter in vertical and 42.304 diopter in horizontal. On the other hand, the female right eye was 44.082 diopter in vertical and 43.77 diopter in horizontal. But, the female left eye was 44.347 diopter in vertical and 43.495 diopter in horizontal. According to the corneal astigmatism axis. The male right eye have 89.9% positive for with the - rule astigmatism, and 8.1 % positive for against - the - rule astigmatism. But, he male left eye have 91.89% positive for with - the - rule astigmatism, and 8.11 % positive for against - the - rule astigmatism. On the other hand, The female right eye have 76.92% positive for with - the - rule astigmatism, and 23.08 % positive for against - the - rule astigmatism. But, the female left have 80.76 % positive for with - the - rule astigmatism, and 17.31 % positive for against - the - rule as tigmatism. The diopter power of corneal astigmatism have 25.57% positive for behind 1 diopter, 44.89% positive for 1 diopter, 18.18% positive for 2 diopter, 5.11% positive for 3 diopter and 6.25% positive for over 4 diopter.

  • PDF

The Study on Accommodation for eyes with pseudo-crystalline lenses (인공수정체안의 조절반응에 관한 연구)

  • Lee, Seok-Ju;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.203-209
    • /
    • 2004
  • Physiological accommodation in aphakia has been reported 0.50D. Also, accommodation appears in pseudo-crystalline lens. However accommodation was not clear how to works in the eyes. Therefore, the purpose of this study is that accommodation has been affected to changes of axial length and corneal refractive power when the accommodative stimulus was taken 10 diopters to person who has pseudo-crystalline lens. To determine of the accommodative response of pseudo-phakic patients who had no side effects over 2 months, we have measured the axial length, corneal refractive power in 48 patients(96 eyes). When the accommodative stimulus was taken about 10 diopters, the axial length increased by $0.05{\pm}0.06mm$ and corneal refractive power increased $0.04{\pm}0.24$ diopter. The changes of axial length in the myopia was increased by $0.19{\pm}0.18D$, emmetropia was increased by $0.12{\pm}0.16D$ and hyperopia was $0.10{\pm}0.19D$. The results of measurement revealed that the mean value was increased $0.03{\pm}0.13D$ in the myopia, and increased $0.21{\pm}0.13D$ in the emmetropia, and decreased $0.02{\pm}0.34D$ in the hyperopia.

  • PDF

The Changes of The Eye and a Correlation Depending on Watching a Smartphone and taking in Alcohol (스마트폰 시청과 알코올 섭취에 따른 눈의 변화와 상관관계)

  • Lee, Jeong-Yun;Yun, Eon-Jeong;Kim, Sung-Min;Hwang, Hye-Kyung;Park, Gyeung-Ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.473-479
    • /
    • 2013
  • Purpose: This article tried to find the changes of the eye and a correlation depending on watching a smartphone and taking in alcohol. Methods: This paper conducted the refraction inspection, the radius of corneal curvature, tonometry and the corneal thickness measurement and analysis for 31 persons (18 males and 13 females) who have healthy drinking habit, not having the medical history of taking medicine related with disorders of the eye, a mental disease, systemic disease and alcohol metabolism. Results: Of respirations depending on watching a smartphone, the alcohol concentration was significantly decreased in 15 minutes, 30 minutes, 45 minutes, 60 minutes and the convalescent stage. (p<0.01, p<0.001) As the result of comparing the refraction inspection after and before watching a smartphone when drinking alcohol, there was a significant difference in the cylindrical power and the axis. (p=0.005, p=0.001) The change of intraocular pressure depending on watching a smartphone after drinking alcohol was decreased significantly from 30 minutes (p<0.001), and watching a smartphone didn't have any significant effect on the corneal thickness depending on the elapsed time from when drinking alcohol. Conclusions: Watching a smartphone and taking in alcohol had a significant effect on the cylindrical power and the axis. Watching a smartphone and taking in alcohol which may cause the visual function-strain are the factors that need to consider before the refraction inspection.

A Study on a Changed Power of Tear lens at Spherical RGP lens Fitting (구면 RGP렌즈 Fitting시 누액렌즈 굴절력 변화에 대한 연구)

  • Park, Seong-Jong;Joo, Seok-Hee;Jung, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.455-462
    • /
    • 2004
  • In this paper, we measured and analysised the power change of tear lens for 85 patients - 170 myopia eyes - who are fitted using RGP lens, considering the BGR of RGP lens, the corneal astigmatism power, and corneal curvature. We got the following results from these experiments; 1. When the BCR of RGP lens changes, the diopters of tear lens of "on-k", 0.05Pt, 01.0Ft, 0.05St, and 0.10St are -0.25D, -0.46D, -0.63D, +0.07D, and +0.26D, respectively. 2. When the corneal astigmatism power changes, the diopters of tear lens of group below 0.75D, group of 1.00D~1.25D, group of 1.50D~1.75D, and group over 2.00D in "on-k" state, are -0.25D, -0.18D, -0.09D, and -0.39D, respectively. 3. When the corneal astigmatism power changes and the BCR of test lens is changed by 0.05mm step, the change values of tear lens diopter for 0.05St and 0.05Ft approximate to ${\pm}0.25D$, while these for 0.10St and 0.10Ft don't approximate to the value below ${\pm}0.25D$.[are irregular value below ${\pm}0.25D$.] 4. When the corneal curvature and the HCR of RGP lens change, the diopters of tear lens of group below 7.50mm, group of 7.55~7.80mm, group of 7.85~8.20mm, and group over 8.25mm in "on-k" state, are -0.40D, -0.11D, -0.20D, and -0.19D, respectively. 5. When the BCR of test lens is changed by 0.05mm step and the corneal curvature increases, the change values of tear lens diopter decrease, while these over 8.25mm are mean value ${\pm}0.17D$ and the value below ${\pm}0.25D$.

  • PDF