• Title/Summary/Keyword: Corneal Power

Search Result 52, Processing Time 0.021 seconds

The Study of the Corneal Diopter Power and Corneal Radius on the Contact Lens Wear of the Korean Female in the Twenties Age (20대 한국여성의 콘택트 렌즈 착용자에 대한 각막 굴절력과 곡률반경에 대한 연구)

  • Kim, Douk-Hoon;Hwang, Sun-Hyung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.2 no.1
    • /
    • pp.127-131
    • /
    • 1997
  • An analysis on the corneal diopter power and corneal radius has been carried out the Korean female in the twenties age. The results were as follows. The most contact lens wears have the early stage of the twenties age, but the increase of aging have a decrease. The mean corneal diopter power on the right eye have 44.04 diopter, but left eye have 43.92 diopter. The mean of corneal radius on the right eye have the 7.66 mm, but left eye have the 7.69 mm. As a results, In increasing of the age, Most mean corneal diopter power have increase, but the mean of corneal radius have not change.

  • PDF

Study on the Analysis of Corneal Variation by Refractive Error (굴절이상에 의한 각막 변화도 분석에 관한 연구)

  • Lee, Hae-Jung;Oh, Hyun-Jin;Jung, Mi-A
    • Journal of Digital Convergence
    • /
    • v.12 no.12
    • /
    • pp.485-490
    • /
    • 2014
  • The purpose of this Study investigated corneal power, corneal astigmatism and corneal axis according to spherical equivalent of refractive error. We measured spherical equivalent, corneal power and corneal astigmatism in 100 subjects from January 2014 to July 2014. Measured spherical equivalent of refractive error were $-3.01{\pm}3.79D$, corneal power of $43.79{\pm}1.60D$ and corneal astigmatism of $-1.17{\pm}0.79D$ respectively. Prevalence of spherical equivalent of refractive error were as follows : myopes (61%), emmetropes (22%), hyperopes(17%). Corneal astigmatism of refractive error greater than +0.75D was 63% and prevalence of corneal astigmatism were as follows : with-the-rlue astigmatism (84.13%), against-the-rule astigmatism(9.52%) respectively. Corneal power by spherical equivalent increased from hyperopia to myopia. Between spherical equivalent of refractive error and the mean corneal power was significant correlation(r=-0.25, p=0.01). A correlation were found between corneal power and spherical equivalent of refractive error in adults. They have the highest distribution of prevalence myopia among the refractive error. When the refractive error was increased, we found that corneal power was steeper. It is recognized that this can be refractive error factor and correct visual function is considered.

The Change of Corneal Refractive Power by Everted Silicone Hydrogel Contact Lens Wear (역방향 실리콘 하이드로겔 렌즈 착용에 따른 각막 굴절력 변화)

  • Kim, Soo-Hyun;Shin, Dong-Min;Jeong, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.271-277
    • /
    • 2013
  • Purpose: The purpose was to study the corneal refractive power changes associated with the wearing of everted silicone hydrogel soft lenses. Methods: The corneal refractive power and corneal astigmatism were measured using corneal topographer (CT-1000, Shin-nippon Co., Japan) for checking change of corneal refractive power and objective refractive error was measured by auto-refractometer (Natural vision-K 5001, Shin-nippon Co., Japan). We measured at baseline and 1 week after lens wearing. Results: The correcting of corneal refractive power could be effective in low myopia. It's more effective to the higher power of greatest meridian of cornea and the more corneal astigmatism. 73% of subjects' refractive error was decrease less than 1 D and 17% of the subjects had an reverse effect (increase) occurs. The reduction of objective refractive error was more effective when cornea refractive power was great or corneal astigmatism was much. Conclusions: Pressure which the everted silicone hydrogel lens to the cornea could be caused. It occurred as the degrees of corneal power, corneal astigmatism and objective refractive error differences. Selection of an appropriate subject is important considering difficulty of changing the parameters of the lens.

The Relationship between Refractive Myopia and Corneal Astigmatism in Korea Women University Students (한국 여자대학생의 굴절성 근시와 각막난시 관계)

  • Kim, Douk-Hoon
    • Journal of Korean Clinical Health Science
    • /
    • v.1 no.1
    • /
    • pp.1-7
    • /
    • 2013
  • Purpose. To analysis the prevalence of the myopia and corneal astigmatism in Korea women university students. Methods. From August 2011 to December 2012, one hundreds subjects were performed in refraction test using the Auto-Keratometry. Results. The mean age of the 100 subjects (200 eyes) was $21.23{\pm}2.34$. The mean spherical refractive power was -$1.78{\pm}1.65$(OD) and -$1.83{\pm}1.67$(OS) Diopter. The mean astigmatism power was $1.22{\pm}0.96$ (OD) and $1.27{\pm}0.91$ (OS). The mean corneal astigmatism was $1.44{\pm}0.81$(OD) and $1.55{\pm}0.93$(OS). Corneal astigmatism was between 0.25 D and 1.25 D in 67.7% of eyes, 1.25 D or higher in 27.5% eyes, and less than 0.25 D in 4.8% of eyes. Astigmatism was with the rule in 65%, against the rule in 31.5%, and oblique in 3.5%. There was a statistical significance between right eye and left eye in the spherical equivalent power(p=0.002). Also there was a statistical significance between spherical power and refractive astigmatism in OD(p=0.006) and OS(0.003) and a statistical significance between corneal astigmatism and refractive astigmatism in OS(p=0.0003). However, there was not a statistical significance between spherical power and corneal astigmatism in OD(p=0.08) and OS(0.1) and a statistical significance between corneal astigmatism and refractive astigmatism in OS(p=0.48). Conclusions. In this study, these results suggested that the analysis of the refractive myopia and corneal astigmatism can provide the visual correct and useful diagnosis information for the eyewear dispensing, contact lens fitting and corneal refraction surgery.

  • PDF

The Correlation of Tear Break-Up Time according to Corneal Refractive Power (각막굴절력에 따른 누액층 파괴시간 분포와 연관성)

  • Jeong, Youn Hong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.6
    • /
    • pp.2839-2843
    • /
    • 2013
  • In this study, the relation between the corneal refractive power and the tear break-up time(TBUT) was analyzed. The results can be effectively used in eye clinics and served as the reference on wearing the contact lenses. We had measured the radius of the corneal of university students who are in the range of 21 to 27 year-old and who don't have eye disease. The corneal refractive power was calculated by using the radius of the corneal. And TBUT is the time when the mire image is distorted first time. The relation between the corneal refractive power and TBUT in right eye was a linear as 'y=37.921-0.610x', in which the larger the refractive power of the cornea is, the shorter TBUT is(negative relationship; r=-0.462, p=0.010). The relation in left eye was also a negatively linear as 'y=41.894-0.695x'(r=-0.509, p=0.004). Consequently, in both eyes the corneal refractive power and TBUT have a negative correlation when myopia is a high. It is possible to predict TBUT, which is necessary in deciding on wear of contact lenses, by measuring the corneal radius of subjects.

A Study of the Corneal Refractive Power and Eye Refractive Error (각막굴절력과 시력의 관련성에 관한 고찰)

  • Cha, Jung Won;Chen, Ko Hsein
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.1
    • /
    • pp.27-35
    • /
    • 1999
  • The corneal power and eye refraction error were studed in 472 unaccommodated right eyes of Korean adult human aged above 20 years. The mean corneal refractive power is 44.08D (female : 44.28D, male : 43.76D). It is 1.1D higher than that of the medel eye by Gullstrand (about 43.0D). The mean corneal power of myopia(44.11D) is similar that of emmetropia(43.97D) and hyperopia(44.24D), but mean corneal power of myopia between the ages of 20 and 29 is 1.42D higher than that of emmetropia. The corneal powers as a function of ages are enlarged with increasing rate of 0.2D~0.3D/10years.

  • PDF

Study of the Axial Length/Corneal Radius Ratio in Determining the Refractive State of the Eye (굴절이상과 안축장/각막곡률반경 비와의 관계에 관한 연구)

  • Seo, Y.W.;Choe, Y.J.
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.2
    • /
    • pp.23-31
    • /
    • 1999
  • The purpose of this study is to evaluate the relationship between axial length/corneal radius ratio and refractive error for human eye. Ocular components were measured Baush & Lomb keratometer, Holden-Payor pachometer, and Stoz Compuscan. Refractive error was measured by subjective refraction. The results were as follows; 1) Spherical equivalent refractive error and axial length/corneal radius ratio was very highly correlated with the correlation coefficient for -0.89. 2) Axial length/corneal radius ratio and axial length, vitreous chamber depth were highly correlated that the correlation coefficients were 0.82, 0.80 respectively. 3) Axial length/corneal radius ratio and anterior chamber depth, corneal power, corneal radius, lens power were correlated with the correlation coefficients for 0.57, 0.40, -0.39, -0.35 respectively. 4) There were no significant correlation between axial length/corneal radius ratio and lens thickness, and corneal thickness.

  • PDF

Analysis of Refractive Errors of the before and after Cataract Surgery by Auto-refractor (안굴절계를 이용한 백내장 수술전후의 굴절이상 분석)

  • Oh, Hyun-Jin;Jung, Mi-A
    • Journal of Convergence Society for SMB
    • /
    • v.6 no.3
    • /
    • pp.65-69
    • /
    • 2016
  • We investigated refractive errors and corneal power with 3 factors such as M, $J_0$, and $J_{45}$ as power vector to find out the changes of refractive errors of the before and after cataract surgery in 119 adults aged 45~85 years with cataract. After the surgery, the 3 factors were changed as $-0.29{\pm}2.38D$ to $-0.18{\pm}0.69D$ in spherical equivalent power which is the M factor, $-0.34{\pm}0.68D$ to $-0.05{\pm}0.42D$ in the $J_0$ factor, and $0.11{\pm}0.45$ to $0.02{\pm}0.17$ in the $J_{45}$ factor. Before and after the surgery, corneal mean refractive power, $J_0$, and $J_{45}$ were changed from $44.11{\pm}1.61D$ to $44.20{\pm}1.58D$, $0.01{\pm}0.50D$ to $0.08{\pm}0.49D$, and $0.02{\pm}0.29$ to $0.08{\pm}0.49$, respectively. The results showed that $J_0$ was the highest relativeness in correlation of the pre- and post-surgery for refractive errors, mean corneal power was the highest correlation for corneal power factor, and corneal power factor was the higher correlation much more than refractive error factor.

Correlation between Anterior and Posterior Corneal Astigmatism in Total Corneal Astigmatism (전체 각막난시에서 전면과 후면 각막난시의 상관성)

  • Kim, Hyojin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.377-382
    • /
    • 2014
  • Purpose: To investigate the effect of anterior, posterior corneal astigmatism and total corneal astigmatism on posterior corneal astigmatism by analyzing correlation. Methods: Participants were 31 patients (31 eyes) without corneal disease at the age range of 22 to 28 who had visited hospital to receive corneal refractive surgery. The total corneal astigmatism and anterior and posterior corneal astigmatism were measured using a rotating scheimpflug camera before surgery. The magnitude of astigmatism was calculated with the difference between the meridian of the steep refractive power and the flat, and With-The-Rule and inverse astigmatism were divided according to the direction of the meridian that was the steepest. Results: The averages of total corneal astigmatism and anterior and posterior astigmatism were found to be $1.13{\pm}0.76D$, $1.51{\pm}0.84D$, and $-0.59{\pm}0.17D$. The magnitude of posterior corneal astigmatism was distributed between -1.0 D and -0.25 D in all the subjects, and when the magnitude of total corneal astigmatism was set as 100, the magnitude of anterior corneal astigmatism was $142.9{\pm}29.9%$. Total corneal astigmatism indicated the highest correlation with the magnitude of anterior astigmatism (y = 0.871x-0.184, $R^2=0.982$) and high negative correlation with posterior astigmatism (y = -2.974x-0.184, $R^2=0.698$). All the subjects' anterior and posterior corneal astigmatism was classified into With-The-Rule. Conclusions: Anterior and posterior corneal astigmatism in the subjects in their 20's showed the magnitude of -3.8 D in 0.2 D and -0.25 D in -1.0 D separately, and both anterior and posterior astigmatism indicated a high percentage of With-The-Rule.

Corneal Abrasion Occurred during Transconjunctival Blepharoplasty in a Patient with History of LASIK Operation (라식수술을 시행한 환자에서 결막절개를 통한 하안검성형술 시 발생한 각막손상)

  • Shin, Jong-In;Kwon, In-Oh;Kim, Chang-Yeon
    • Archives of Plastic Surgery
    • /
    • v.38 no.4
    • /
    • pp.543-546
    • /
    • 2011
  • Purpose: LASIK, one of the currently popular ophthalmic procedures, can sometimes result in dry eye symptoms. In the patient who had underwent LASIK operation, the periorbital surgery may be more likely to lead to such a complication as dry eye symptom. We would like to report a case of corneal abrasion occurred after transconjunctival blepharoplasty in post-LASIK state and suggest the method about preventing the complication. Methods: A 30-year-old female patient underwent transconjunctival blepharoplasty and microfat graft into the face. She had history of LASIK operation 2 years ago. Corneal protector was applied to both eye during transconjunctival operation. After the surgery, she complained of visual blurring at left side. Ophthalmic examination revealed corneal abrasion of left eye. Results: Cornea protecting lens was applied to left eye for 2 weeks. Steroid and antibiotic eye drops were applied for relieving the symptoms and the prevention from progressing of complication. After 1 week, visual power and acuity was recovered to preoperative state. No other specific complications happened. Conclusion: Post-LASIK patient may have possibility of decreased corneal sensation and tear production. Preoperative ophthalmic examination is recommended for the prevention of complication. When corneal protector is applied, we suggest Optagel$^{(R)}$ as a useful lubricant.