Sung, Ji Hee;Kim, Do Hoon;Oh, Mi-Jung;Lee, Kyoung Ju;Bae, Young A;Kwon, Kye Won;Lee, Seung Min;Kang, Ho Joon;Choi, Jinyoung
Tuberculosis and Respiratory Diseases
/
v.78
no.3
/
pp.276-280
/
2015
Cryptococcal pneumonia usually occurs in immunocompromised patients with malignancy, acquired immune deficiency syndrome, organ transplantations, immunosuppressive chemotherapies, catheter insertion, or dialysis. It can be diagnosed by gaining tissues in lung parenchyma or detecting antigen in blood or bronchoalveolar lavage fluid. Here we report an immunocompetent 32-year-old male patient with diabetes mellitus diagnosed with cryptococcal pneumonia after a ultrasound-guided percutaneous supraclavicular lymph node core needle biopsy. We treated him with fluconazole at 400 mg/day for 9 months according to the guideline. This is the first case that cryptococcal pneumonia was diagnosed from a percutaneous lymph node biopsy in South Korea.
So Yeong Jeong;Jung Hwan Baek;Sae Rom Chung;Young Jun Choi;Dong Eun Song;Ki-Wook Chung;Won Woong Kim;Jeong Hyun Lee
Korean Journal of Radiology
/
v.23
no.10
/
pp.1019-1027
/
2022
Objective: Thyroidectomy bed lesions frequently show suspicious ultrasound (US) features after thyroid surgery. Fine-needle aspiration (FNA) may not provide definitive pathological information about the lesions. Although core-needle biopsy (CNB) has excellent diagnostic performance in characterizing suspicious thyroid nodules, no published studies have evaluated the performance of CNB specifically for thyroidectomy bed lesions. Therefore, we aimed to evaluate the diagnostic performance and safety of CNB for characterizing thyroidectomy bed lesions. Materials and Methods: A total of 124 thyroidectomy bed lesions in 113 patients (79 female and 34 male; age, 23-85 years) who underwent US-guided CNB between December 2008 and December 2020 were included. We reviewed the US imaging features of the target lesions and the histories of previous biopsies. The pathologic results, diagnostic performance for malignancy, and complications of CNB were analyzed. Results: All samples (100%) obtained by CNB were adequate for pathological analysis. Pathological analysis revealed inconclusive results in two lesions (1.6%). According to the reference standard, 50 lesions were ultimately malignant (40.3%), and 72 were benign (58.1%), excluding the two inconclusive lesions. The performance of CNB for diagnosing malignant thyroidectomy bed lesions in the 122 lesions had a sensitivity of 98.0% (49/50), a specificity of 100% (72/72), positive predictive value of 100% (49/49), and negative predictive value of 98.6% (72/73). Eleven lesions were referred for CNB after prior inconclusive FNA results in thyroidectomy bed lesions, for all of which CNB yielded correct conclusive pathologic diagnoses. According to the pathological analysis of CNB, there were various benign lesions (58.9%, 73/124) besides recurrence, including benign postoperative lesions other than suture granuloma (32.3%, 40/124), suture granuloma (15.3%, 19/124), remnant thyroid tissue (5.6%, 7/124), parathyroid lesions (4%, 5/124), and abscesses (1.6%, 2/124). No major or minor complications were associated with the CNB procedure. Conclusion: US-guided CNB is accurate and safe for characterizing thyroidectomy bed lesions.
Background: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a technique developed to allow mediastinal staging of lung cancer and also to evaluate intrathoracic lymphadenopathy. In a tuberculosis-endemic area, tuberculosis should be considered as an etiology of mediastinal lymphadenopathy. The aim of this study was to investigate the utility of the routine culture for tuberculosis from specimens of EBUS-TBNA. Methods: We prospectively performed routine culture for tuberculosis from aspiration or core biopsy specimens got from 86 patients who had undergone EBUS-TBNA due to mediastinal lymphadenopathy between March 2010 and March 2011. Results: A total of 135 lymph node aspiration and 118 core biopsy specimens were included in this analysis. We confirmed the malignancy in 62 (72.9%), tuberculosis in 7 (8.1%), sarcoidosis in 7 (8.1%), asperogillosis in 2 (2.3%) and pneumoconiosis in 2 (2.3%) patients. One lung cancer patient had pulmonary tuberculosis coincidentally and 5 patients had unknown lymphadenopathy. The number of positive culture for Mycobacterium tuberculsosis by EBUS-TBNA is 2 (1.5%) from 135 lymph node aspiration specimens and 2 (1.7%) from 118 core biopsy specimens. Out of eight patients confirmed with tuberculosis, only one patient had positive mycobacterial culture of aspiration specimen from EBUS-TBNA without histopathologic diagnosis. Conclusion: These results propose that routine culture for tuberculosis from EBUS-TBNA may not provide additional information for the diagnosis of coincident tuberculous lymphadenitis. However, if there is any possibility of tuberculous lymphadenopathy or pulmonary tuberculosis, it should be considered to perform EBUS-TBNA in patients who have negative sputum AFB smears or no sputum production.
Sun Hwa Chung;Hyun Ji Kang;Hyo Jeong Lee;Jin Sil Kim;Jeong Kyong Lee
Journal of the Korean Society of Radiology
/
v.82
no.5
/
pp.1207-1217
/
2021
Purpose To evaluate the safety and efficacy of ultrasound-guided percutaneous core needle biopsy (USPCB) of pancreatic and peripancreatic lesions adjacent to critical vessels. Materials and Methods Data were collected retrospectively from 162 patients who underwent USPCB of the pancreas (n = 98), the peripancreatic area adjacent to the portal vein, the paraaortic area adjacent to pancreatic uncinate (n = 34), and lesions on the third duodenal portion (n = 30) during a 10-year period. An automated biopsy gun with an 18-gauge needle was used for biopsies under US guidance. The USPCB results were compared with those of the final follow-up imaging performed postoperatively. The diagnostic accuracy and major complication rate of the USPCB were calculated. Multiple factors were evaluated for the prediction of successful biopsies using univariate and multivariate analyses. Results The histopathologic diagnosis from USPCB was correct in 149 (92%) patients. The major complication rate was 3%. Four cases of mesenteric hematomas and one intramural hematoma of the duodenum occurred during the study period. The following factors were significantly associated with successful biopsies: a transmesenteric biopsy route rather than a transgastric or transenteric route; good visualization of targets; and evaluation of the entire US pathway. In addition, the number of biopsies required was less when the biopsy was successful. Conclusion USPCB demonstrated high diagnostic accuracy and a low complication rate for the histopathologic diagnosis of pancreatic and peripancreatic lesions adjacent to critical vessels.
Korea is rapidly entering into an aging society, and an increasing socioeconomic burden related to prostate cancer is inevitable. Therefore, the need for early detection and accurate diagnosis of prostate cancer is becoming increasingly critical. Ideally, a biopsy should accurately detect cancers using a minimum number of cores. However, as prostate cancer is often indistinguishable on imaging, image-guided targeted biopsies alone are insufficient for diagnosis. After decades of trial and error, the diagnosis of prostate cancer relies heavily on systematic biopsy, which is characterized by random and repetitive core acquisition throughout the gland. This review will provide an overview of the historical aspects of prostate cancer diagnosis. Moreover, the review will also address the general considerations involved in prostate biopsy, and discuss the periprocedural management of the patients.
Metastases to the thyroid gland have rarely been reported in clinical settings, and the thyroid gland is an uncommon site for breast carcinoma metastasis. We report a case of a 64-year-old breast cancer patient diagnosed with metastatic breast carcinoma in the thyroid gland after performing ultrasonography (US)-guided core needle biopsy (CNB) and subsequent total thyroidectomy. On US, the thyroid lesion appeared to be mildly enlarged with multiple internal hypoechoic lines and a few microcalcifications without mass formation. Under US-guidance, CNB was performed by targeting the area with microcalcifications and subsequently diagnosed as metastatic breast carcinoma. Total thyroidectomy revealed that the patient had metastatic invasive ductal carcinoma of the breast with lymphatic spread involving both lobes and the isthmus of the thyroid gland. Although the thyroid gland is an uncommon metastatic site, the unusual features of thyroid metastasis can be observed on US; thus, US-guided CNB effectively aids the diagnosis of thyroid metastasis.
Park, Mina;Kim, Eun-Kyung;Kim, Min Jung;Moon, Hee Jung
Investigative Magnetic Resonance Imaging
/
v.17
no.2
/
pp.101-109
/
2013
Objective: To investigate roles of dynamic contrast enhanced magnetic resonance (DCE MR) and diffusion-weighted (DW) imaging in preoperative prediction of underestimation of ductal carcinoma in situ (DCIS) ${\geq}2cm$ on US guided core needle biopsy. Materials and Methods: Twenty two patients with DCIS on US-guided 14 gauge core needle biopsy were included. Patients were divided into a group with and without DCIS underestimation based on histopathology. MR images including DCE and DW imaging were obtained with a 3.0-T MR. The lesion type (mass or non-mass), enhancement pattern, peak enhancement, and apparent diffusion coefficient (ADC) values of proven malignant masses were generated using software of CADstream and compared between two groups using Fisher's exact test and Mann Whitney test. Results: Eight patients were in the group with underestimation and 14 patients were in the group without underestimation. The lesion type and enhancement pattern were not different between two groups (P values = 1.000 and 0.613, respectively). The median peak enhancement of lesions with underestimation was 159.5%, higher than 133.5% of those without underestimation, but not significant (P value = 0.413). The median ADC value of lesions with underestimation was $1.26{\times}10^{-3}mm^2/sec$, substantially lower than $1.35{\times}10^{-3}mm^2/sec$ of those without underestimation (P value = 0.094). Conclusion: ADC values had the potential to preoperatively predict DCIS underestimation on US-guided core needle biopsy, although a large prospective series study should be conducted to confirm these results.
Nodular pulmonary amyloidosis is one of the rare manifestation of amyloid disease. It is known to be caused by amyloid L fibrils in the majority of cases. We experienced an unusual case of a forty-one year-old woman who was presented with multiple nodular lesion on the chest X-ray. CT-guided core needle biopsy, performed on the lesion, showed apple green birefringes, when stained Congo red and examined under polarized light, Ultrastructurally, there are randomly oriented, forming densed networks, and consists of fine, 7.5 to 10nm diameter, rigid, non-branching filaments of various lengths in electron-microscopic finding. We report a case of primary diffuse nodular pulmonary amyloidosis only localized in the lung, which was confirmed by CT guided core needle biopsy.
Background: Pulmonary sarcoidosis often involves mediastinal or hilar lymph nodes in the lung parenchyma. Mediastinoscopy is the gold standard for diagnosis, but it is invasive and expensive. Transbronchial needle aspiration using conventional bronchoscope is less invasive than mediastinoscopy, but its diagnostic accuracy is in question due to the blind approach to targeting lymph nodes. Transbronchial needle aspiration (TBNA) via endobronchial ultrasound (EBUS) has high diagnostic value due to direct visualization of lymph nodes and to its relatively safeness. The purpose of this study was to assess the usefulness of EBUS-TBNA in the diagnosis of pulmonary sarcoidosis. Methods: Twenty-five patients with symptoms of sarcoidosis were enrolled into this study. Core tissue was obtained for a definitive diagnosis. Endobronchial biopsy, transbronchial lung biopsy, and bronchoalveolar lavage were performed to verify diagnosis. For patients without a confirmed diagnosis after the above procedures were performed, the additional procedures of mediastinoscopy or video-associated thoracoscopic surgery were performed to confirm a final diagnosis. Results: A total 25 EBUS procedures were done and 50 lymph nodes were aspirated. Thirty-three (37) out of 50 lymph nodes were consistent with non-caseating granuloma, confirming sarcoidosis as the final diagnosis. Sarcoidosis was the final diagnosis for all 25 patients, and 21 required EBUS-TBNA for a final diagnosis. There were no complications associated with the procedure. Conclusion: EBUS-TBNA is already a well-known procedure for diagnosing mediastinal or hilar lymphadenopathy. We used EBUS-TBNA for the diagnosis of pulmonary sarcoidosis and our results showed 84% diagnostic accuracy and no complications related to the procedure. EBUS-TBNA is a reliable and practical diagnostic modality in the diagnosis of pulmonary sarcoidosis.
Youn, You Sook;Yun, Hye Won;Kim, Sun Young;Sul, Ji Yeong;Song, Chang Jun;Kim, Jin Man;Park, Kyung Duk
Clinical and Experimental Pediatrics
/
v.48
no.8
/
pp.839-845
/
2005
Purpose : Neck masses, in pediatric population, derive from a multitude of congenital, inflammatory, or neoplastic diseases. The majority of these masses represent benign conditions. However, thorough clinical evaluation is required to rule out malignant diseases. We evaluated the causes, clinical characteristics and outcomes of children with neck masses who underwent tissue biopsy. Methods : A total of 28 medical records of children with neck mass who underwent tissue biopsy at Chungnam National University Hospital, from January 2000 to March 2004 were retrospectively analyzed. The methods of biopsy were ultrasonography guided core biopsy(CB), fine needle aspiration biopsy(FNAB) and excisional biopsy. Results : Out of 28 patients, half were boys. The most common location of the mass was the posterior cervical area(N=19, 67.9%). Laboratory findings of peripheral blood and serologic studies were nonspecific. In 25(89.3%) cases, CB or FNAB was initially performed for neck masses. Among them 10 cases(40%) were reactive hyperplasia, 8(32%) inflammatory granulation tissues, 4(16%) necrotizing lymphadenitis, and 3(12%) acute suppurative inflammations. Initially, excisional biopsy was performed for diagnosis in 3(10.7%) cases. Diagnosis of these cases was thyroglossal duct cyst, dermoid cyst and lymphoblastic lymphoma, respectively. Conclusion : Most neck masses in children were benign. CB and FNAB were safe methods for tissue sampling, without need for general anesthesia.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.