• Title/Summary/Keyword: Core wall

검색결과 451건 처리시간 0.024초

복합 프리캐스트 콘크리트 패널의 구조 거동에 대한 실험적 연구 (A Experimental Study on Structural Behavior of Hybrid Precast Concrete Panel)

  • 이상섭;박금성
    • 대한건축학회논문집:구조계
    • /
    • 제34권9호
    • /
    • pp.11-18
    • /
    • 2018
  • As the height of the modular buildings increases, their stability becomes more and more dependent on the core. All traditional construction methods in structural concrete and steel can be utilized for cores in modular buildings but a core system with dry connection is more desirable to complete a greater degree of factory finish and faster erection of modular buildings. In order to do that, the hybrid PC(precast concrete) panel, which has a pair of C-shaped steel beams combined at the top and bottom of a concrete wall, was developed, In this study the cyclic lateral loading test on the hybrid PC panel is carried out and the panel configurations are examined to enhance the structural performance in comparison with the RC wall. Experimental results show that the strength of hybrid PC panel is about 70% of thar ot RC wall and the anchorage of vertical reinforcing bar welded to C-shaped steel beam needs to be improved.

Research on three-point bending fatigue life and damage mechanism of aluminum foam sandwich panel

  • Wei Xiao;Huihui Wang;Xuding Song
    • Steel and Composite Structures
    • /
    • 제51권1호
    • /
    • pp.53-61
    • /
    • 2024
  • Aluminum foams sandwich panel (AFSP) has been used in engineering field, where cyclic loading is used in most of the applications. In this paper, the fatigue life of AFSP prepared by the bonding method was investigated through a three-point bending test. The mathematical statistics method was used to analyze the influence of different plate thicknesses and core densities on the bending fatigue life. The macroscopic fatigue failure modes and damage mechanisms were observed by scanning electron microscopy (SEM). The results indicate that panel thickness and core layer density have a significant influence on the bending fatigue life of AFSP and their dispersion. The damage mechanism of fatigue failure to cells in aluminum foam is that the initial fatigue crack begins the cell wall, the thinnest position of the cell wall or the intersection of the cell wall and the cell ridge, where stress concentrations are more likely to occur. The fatigue failure of aluminum foam core usually starts from the semi-closed unit of the lower layer, and the fatigue crack propagates layer by layer along the direction of the maximum shear stress. The results can provide a reference for the practical engineering design and application of AFSP.

Eccentric compressive behavior of novel composite walls with T-section

  • Qin, Ying;Chen, Xin;Xi, Wang;Zhu, Xingyu;Chen, Yuanze
    • Steel and Composite Structures
    • /
    • 제35권4호
    • /
    • pp.495-508
    • /
    • 2020
  • Double skin composite walls are alternatives to concrete walls to resist gravity load in structures. The composite action between steel faceplates and concrete core largely depends on the internal mechanical connectors. This paper investigates the structural behavior of novel composite wall system with T section and under combined compressive force and bending moment. The truss connectors are used to bond the steel faceplates to concrete core. Four short specimens were designed and tested under eccentric compression. The influences of the thickness of steel faceplates, the truss spacing, and the thickness of web wall were discussed based on the test results. The N-M interaction curves by AISC 360, Eurocode 4, and CECS 159 were compared with the test data. It was found that AISC 360 provided the most reasonable predictions.

알긴산소다를 이용한 멸치어유의 미세캡슐화 (Microencapsulation of Anchovy Oil by Sodium Alginate)

  • 임상빈;좌미경
    • 한국식품영양과학회지
    • /
    • 제28권4호
    • /
    • pp.890-894
    • /
    • 1999
  • Microencapsulation of anchovy oil as a core material in sodium alginate as a wall material was inves tigated. Microencapsulation was accomplished by injecting an oil/water emulsion, consisting of a mixture of liquefied sodium alginate and emulsifier, under high pressure through an orifice submerged in a calcium lactate solution. Microcapsules suspended in a dispersion fluid were observed under a fluorescence mi croscope to verify the presence of the capsules and to note coalescence or degradation of the capsules. Optimum conditions for microencapsulation of anchovy oil were obtained when 1.0% aqueous solution of sodium alginate contained 3% of a 1:1 ratio of ESPR 25(polyglycerine+polylinoleate) and TW 20(sorbitan laurate+ethylene oxide) as an emulsifier in terms of capsule size and size distribution, and emulsion stability. The airless sprayer produced microcapsules with a diameter between 15.9 and 73.9 m with different concentration of a wall material. The optimum mixing ratio of wall material to core material was 90:10(wt/wt). 0.2% calcium lactate was appropriate as a dispersion fluid.

  • PDF

Several Issues Closely Related to Construction in the Structural Design of Wuhan Center

  • Jian, Zhou
    • 국제초고층학회논문집
    • /
    • 제11권3호
    • /
    • pp.189-196
    • /
    • 2022
  • The practical difficulties of construction will impose many restrictions on the structural design, and the construction method can also provide unexpected ideas for solving design problems. Through the discussion of three issues closely related to construction in the structural design of Wuhan Center, this paper illustrates the importance of in-depth consideration of the construction situations in the structural design stage. The topics of "Connection between Embedded Steel Plates in Steel Plate Composite Shear Wall" and "Connection Joint between Outrigger Truss and Core Wall" are about how to facilitate on-site construction by simplifying and optimizing detail design. The topic of "Adjusting Internal Force Distribution by Optimizing Construction Sequence" is about how to make the construction process a tool for structural design.

초고강도 콘크리트로 타설된 내부코아 벽체의 균열발생 및 제어에 관한 실험적 연구 (An Experimental Study on Crack Control of Core-wall Using 700kg/$\textrm{cm}^2$ Ultra High Strength Concrete)

  • 윤영수;이승훈;노병용;박희도
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1995년도 봄 학술발표회 논문집
    • /
    • pp.201-206
    • /
    • 1995
  • This paper presents the experimental study on crack control of core-wall placed with 700kg/$\textrm{cm}^2$ Ultra high strength concrete. The thermal sensors were installed into the core-walls prior to the concrete casting to measure the heat of hydration and atmospheric temperature whose difference might cause the initial crack. Several curing schemes were taken for each basement floor 8 thru 6 to examine the influence of curing method on the crack width, total crack length and the number of crack occurred. This paper demonstrates that the proper curing scheme have a great favorable effect on the initial crack control on the structural elements with noticiable reduction in crack width.

  • PDF

난류경계층에 의한 다층재질 원통형 실린더의 유체소음 해석 연구 (A Study of Flow Induced Noise for Multilayered Cylinder due to Turbulent Boundary Layer)

  • 신구균;홍진숙;이헌곤
    • 소음진동
    • /
    • 제6권5호
    • /
    • pp.671-677
    • /
    • 1996
  • This paper presents the analytical method for predicting turbulence- induced noise in the multilayered cylinder composed of an outer hose, an inner fluid and an internal core. It is assumed that an infinite axisymmetric cylinder is located horizontally in water with free stream velocity and the turbulent boundary layer (TBL) surrounding the outer hose is fully developed and homogeneous. The transfer function at the core surface due to the propagation of the pressure fluctuation within the TBL is formulated using the linearized Navier-Stockes equation for solid and fluid. In the estimation of the energy spectrum of wall pressure fluctuation, the empirical formula proposed by Strawderman based on the Corcos model is used. A general algorithm for the calculation of the pressure level at the surface of a core, that is, turbulence- induced noise, is presented. Through the detailed numerical simulation, it is found that the major noise mechanism is the propagation of the bulge wave along hose.

  • PDF

Reinforced concrete core-walls connected by a bridge with buckling restrained braces subjected to seismic loads

  • Beiraghi, Hamid
    • Earthquakes and Structures
    • /
    • 제15권2호
    • /
    • pp.203-214
    • /
    • 2018
  • Deflection control in tall buildings is a challenging issue. Connecting of the towers is an interesting idea for architects as well as structural engineers. In this paper, two reinforced concrete core-wall towers are connected by a truss bridge with buckling restrained braces. The buildings are 40 and 60-story. The effect of the location of the bridge is investigated. Response spectrum analysis of the linear models is used to obtain the design demands and the systems are designed according to the reliable codes. Then, nonlinear time history analysis at maximum considered earthquake is performed to assess the seismic responses of the systems subjected to far-field and near-field record sets. Fiber elements are used for the reinforced concrete walls. On average, the inter-story drift ratio demand will be minimized when the bridge is approximately located at a height equal to 0.825 times the total height of the building. Besides, because of whipping effects, maximum roof acceleration demand is approximately two times the peak ground acceleration. Plasticity extends near the base and also in major areas of the walls subjected to the seismic loads.

주조 포오스트의 적합도에 관한 연구 (A STUDY ON THE ADAPTATION OF THE CAST POST)

  • 박동관;장익태
    • 대한치과보철학회지
    • /
    • 제24권1호
    • /
    • pp.55-65
    • /
    • 1986
  • An in vitro study was performed to evaluate adaptation of custom direct, custom indirect, and prefabricated post system on 15 extracted upper central incisors. 15 specimens were prepared and equally devided into 3 groups under random sampling. Each group of 5 cast posts was made with custom direct, custom indirect, and prefabricated post core method. Gap between inner wall of the dentin and outer wall of the cast post was measured on electron microphotographic prints at x500 magnification. The result were as follows ; 1. No significant difference of adaptation at cervical portion was found between each method. 2. Prefabricated post core method had poor adaptation compared with other methods. 3. Even distribution of adaptation was found in custom direct method between each portion. 4. Prefabricated post core method showed remarkable difference in adaptation between each portion.

  • PDF

내부 폭발하중을 받는 철근콘크리트 코어의 연쇄붕괴 해석 (Progressive Collapse Analysis of Reinforced Concrete Core Structure Subjected to Internal Blast Loading)

  • 김한수;안재균;안효승
    • 콘크리트학회논문집
    • /
    • 제26권6호
    • /
    • pp.715-722
    • /
    • 2014
  • 본 논문에서는 철근콘크리트 코어 구조물의 내부폭발 효과를 폭발이나 충격해석에 특화되어 있는 하이드로코드인 Ansys Autodyn을 이용하여 조사하였다. 내부폭발의 경우 폭발하중의 반사효과로 인해 더욱 큰 파괴를 일으킬 수 있다. 그러므로, 본 논문에서는 UFC 3-340-02 를 사용하여 내부 폭발현상을 입증하였다. 추가적으로 Autodyn을 사용한 해석에 관하여 UFC에서 예제로 제시하는 폭발하중의 반사에 관한 실험 결과를 비교하여 Autodyn이 내부폭발 효과를 해석하는데 적합함을 증명하였다. 나아가, 초고층빌딩에서 가장 중요한 부분 중의 하나의 코어 구조의 붕괴메커니즘을 Autodyn을 사용하여 해석하였다. 내부폭발이 코어에 충격을 가할 때, 코어는 모서리와 폭발 정면 부분이 대부분 피해를 입었다. 그러므로, 코어 벽체가 피해를 입게 된다면 코어 구조물의 연쇄붕괴가 발생할 수 있다.