측정용 전압 변성기 오차 보상 알고리즘 (Compensation Algorithm for a Measurement Voltage Transformer)

  • 강용철;박종민;이미선;장성일;김용균
    • 전기학회논문지
    • /
    • 제57권5호
    • /
    • pp.761-766
    • /
    • 2008
  • This paper describes a compensation algorithm for a measurement voltage transformer (VT) based on the hysteresis characteristics of the core. The error of the VT is caused by the voltages across the primary and secondary windings. The latter depends on the secondary current whilst the former depends on the primary current, i.e. the sum of the exciting current and the secondary current. The proposed algorithm calculates the voltages across the primary and secondary windings and add them to the measured secondary voltage for compensation. To do this, the primary and secondary currents should be estimated. The secondary current is obtained directly from the secondary voltage and used to calculate the voltage across the secondary winding. For the primary current, in this paper, the exciting current is decomposed into the two currents, i.e. the core-loss current and the magnetizing current. The core-loss current is obtained by dividing the primary induced voltage by the core-loss resistance. The magnetizing current is obtained by inserting the flux into the flux-magnetizing current curve. The calculated voltages across the primary and secondary windings are added to the measured secondary current for compensation. The proposed compensation algorithm improves the error of the VT significantly.

Iron Core Design of 3-Phase 40MVA HTS Power Transformer Considering Voltages per Turn

  • Lee, Chan-joo;Seok, Bok-yeol
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제4B권2호
    • /
    • pp.54-58
    • /
    • 2004
  • This paper presents the iron core design method of a high temperature superconducting (HTS) transformer considering voltages per turn (V/T). In this research, solenoid type HTS coils were selected for low voltage (LV) winding and double pancake coils for high voltage (HV) winding, just as in conventional large power transformers. V/T is one of the most fundamental elements used in designing transformers, as it decides the core cross sectional area and the number of primary and secondary winding turns. By controlling the V/T, the core dimension and core loss can be changed diversely. The leakage flux is another serious consideration in core design. The magnetic field perpendicular to the HTS wire causes its critical current to fall rapidly as the magnitude of the field increases slowly. Therefore in the design of iron core as well as superconducting windings, contemplation of leakage flux should be preceded. In this paper, the relationship between the V/T and core loss was observed and also, through computational calculations, the leakage magnetic fields perpendicular to the windings were found and their critical current decrement effects were considered in relation to the core design. The % impedance was calculated by way of the numerical method. Finally, various models were suggested.

A Transformer Protection Relay Based on Induced Voltages

  • Kang, Yong-Cheol;Lee, Byung-Eun
    • KIEE International Transactions on Power Engineering
    • /
    • 제3A권2호
    • /
    • pp.70-78
    • /
    • 2003
  • This paper describes a transformer protection relay based on induced voltages. The ratio of the induced voltages of the primary and secondary windings is equal to the turns ratio during normal operating conditions such as magnetic inrush, overexcitation, and steady state, but it differs from the turns ratio in the case of internal faults. For a single-phase and a three-phase Y-Y transformer, the induced voltages are estimated and the ratios are compared with the turns ratio. For three-phase Y-Δ transformers, the differences between the induced voltages are estimated to use the line currents because delta-winding currents are practically unavailable. The proposed relay is tested under various conditions such as magnetic inrush, internal winding faults, overexcitation, and different core characteristics. The results evidently indicate that the relay successfully discriminates internal faults from magnetic inrush and overexcitation. This paper concludes by implementing the relay into a TMS320C6701 digital signal processor and reports satisfactory results. The relay requires no hysteresis data and can reduce the operating time of a relay.

Dynamic-Voltage/Frequency-Scaling 알고리즘에서의 다중 인가 전압 조절 시스템 용 High-speed CMOS Level-Up/Down Shifter (A Novel High-speed CMOS Level-Up/Down Shifter Design for Dynamic-Voltage/Frequency-Scaling Algorithm)

  • 임지훈;하종찬;위재경;문규
    • 대한전자공학회논문지SD
    • /
    • 제43권6호
    • /
    • pp.9-17
    • /
    • 2006
  • SoC(System-On-Chip) 시스템에서 초 저전력 시스템을 구현하기 위한 dynamic voltage and frequency scaling (DVFS)알고리즘에 사용될 시스템 버스의 다중 코어 전압 레벨을 생성해주는 새로운 다계층(multi-level) 코어 전압용 high-speed level up/down Shifter 회로를 제안한다. 이 회로는 내부 회로군과 외부 회로군 사이에서 서로 다른 전압레벨을 조정 접속하는 I/O용 level up/down shifter interface 회로로도 동시에 사용된다. 제안하는 회로는 인터페이스 접속에서 불가피하게 발생하는 속도감쇄와 Duty Ratio 불안정 문제를 최소화하는 장점을 갖고 있다. 본 회로는 500MHz의 입력 주파수에서 $0.6V\sim1.6V$의 다중 코어 전압을 각 IP들에서 사용되는 전압레벨로, 또는 그 반대의 동작으로 서로 Up/Down 하도록 설계하였다 그리고 제안하는 I/O 용 회로의 level up shifter는 500MHz의 입력 주파수에서 내부 코어 용 level up shifter의 출력전압인 1.6V를 I/O 전압인 1.8V, 2.5V, 3.3V로 전압레벨을 상승 하도록 설계하였으며, level down shifter는 반대의 동작으로 1Ghz의 입력 주파수에서 동작하도록 설계하였다. 시뮬레이션 및 결과는 $0.35{\mu}m$ CMOS Process, $0.13{\mu}m$ IBM CMOS Process 와 65nm CMOS model 변수를 이용한 Hspice를 통하여 검증하였다. 또한, 제안하는 회로의 지연시간 및 파워소모 분석과 동작 주파수에 비례한 출력 전압의 Duty ratio 왜곡에 대한 연구도 하였다.

공축 전기방사를 이용한 Core-Sheath형 복합나노섬유의 제조 (Fabrication of Core-Sheath Nanocomposite Fibers by Co-axial Electrospinning)

  • 강민정;이승신
    • 한국의류학회지
    • /
    • 제37권2호
    • /
    • pp.224-234
    • /
    • 2013
  • This study investigates the fabrication of core-sheath nanocomposite fibers by locating germanium (Ge) and silicon dioxide ($SiO_2$) nanoparticles selectively in the sheath layer by co-axial electrospinning. Co-axially spun fibers were prepared by electrospinning a pure PVA solution and Ge/$SiO_2$/PVA solution as the core and sheath layer, respectively. Core-sheath nanocomposite fibers were electrospun under a variety of conditions that include various feed rates for the core and sheath solutions, voltages, and concentric needle diameters, in order to find an optimum spinning condition. Ge/$SiO_2$ nanocomposite fibers were also prepared by uniaxial electrospinning to compare fiber morphology and nanoparticle distribution with core-sheath nanofibers. Using scanning electron microscopy, transmission electron microscopy, and energy dispersive X-ray analysis, it was demonstrated that the co-axial approach resulted in the presence of nanoparticles near the surface region of the fibers compared to the overall distribution obtained for uni-axial fibers. The co-axially electrospun Ge/$SiO_2$/PVA nanofiber webs have possible uses in high efficiency functional textiles in which the nanoparticles located in the sheath region provide enhanced functionality.

2축 마이크로 플럭스게이트 센서 제작을 통한 전자 나침반 개발 (Development of Electronic Compass Using 2-Axis Micro Fluxgate Sensor)

  • 박해석;심동식;나경원;황준식;최상언
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권9호
    • /
    • pp.418-423
    • /
    • 2003
  • This paper describes an electronic compass using micromachined X- and Y-axis micro fluxgate sensors which were perpendicularly aligned each other to measure X- and Y-axis magnetic fields respectively. The fluxgate sensor was composed of rectangular-ring shaped magnetic core and solenoid excitation(49 turns) and pick-up(46 turns) coils. Excitation and pick-up coil patterns which were formed opposite to each other wound the magnetic core alternatively to improve the sensitivity and to excite the magnetic core in an optimal condition with reduced excitation current. The magnetic core has DC effective permeability of ~1000 and coercive field of ~0.1 Oe. The magnetic core is easily saturated due to the low coercive field and closed magnetic path for the excitation field. To decrease the difference of induced second harmonic voltages from X- and Y-axis, excitation condition of 2.8 $V_{P-P}$ and 1.2 MHz square wave was selected. Excellent linear response over the range of -100 $\mu$T to +100 $\mu$T was obtained with 210 V/T sensitivity. The size of each micro fluxgate sensor excluding pad region was about 2.6${\times}$1.7 $mm^2$ and the power consumption was estimated to be 14 mW.W.

1MVA 고온 초전도 변압기 개념설계 (Conceptual Design of 1 MVA HTS Transformer)

  • 김우석;한송엽;최경달;주형길;홍계원
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.233-236
    • /
    • 2002
  • A conceptual design of single phase high Tc superconducting (HTS) 1MVA transformer was presented in this paper. The rated voltages of each sides of the transformer are 22.9kV /6.6kV respectively. Double pancake windings of BSCCO-2223 HTS tape and the room temperature shell type core are adopted. The HTS tapes of windings are going to be cooled down to 65K by sub-cooled liquid nitrogen. A cryostat made of nonmagnetic and nonconducting material with a bore is going to be used in order to locate the core out of the cryostat. This conceptual design will be modified and a fabrication of the machine is going to be based on the presented design in this paper.

  • PDF

3차원 유한요소법을 이용한 비접촉 전력 전달 장치 특성 해석 (Characteristic Analysis of Contactless Energy Transmission System using 3D Finite Element Method)

  • 우경일;박한석;조윤현
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권1호
    • /
    • pp.22-26
    • /
    • 2005
  • This paper proposes the calculation method of magnetic coupling coefficient of the contactless energy transmission system by 3D finite element method with a variation of the secondary core positions. The primary, secondary self and leakage inductances and the capacitances of a resonant circuit are calculated by the finite element analysis results. From these values, the magnetic coupling coefficients are obtained. The secondary voltages and currents according to the secondary core positions are calculated by using the resonant circuit and compared.

Convex형 권선배치방식을 취한 권철심변압기의 충격파절연설계에 관한 연구 (Study on Insulation Design of Surge Voltages for Convex Winding type Ribbon Core Transformer)

  • 황영문;조철제;김중한
    • 전기의세계
    • /
    • 제22권3호
    • /
    • pp.13-24
    • /
    • 1973
  • In this report, as a method to solve the problems on impulse insulation coordination in ribbon core transformer owing to it's BIL stepping up, new design to alter winding distribution of multiple-layer concentric winding to Convex type winding is proposed. The main focus of this method is to settle the weakness of axial direction insulation strength and as a result of theoretical analysis through experiment of model transformers, the following conclusions are obtained; (a) As the electric loadings in a design which increases by strengthenning axial direction insulation endurance in presently avarilable transformers owing to it's BIL stepping up can be restricted in Convex type winding, reasonable design will be suited to the transformer with higher BIL. (b) Convex type winding is a very improved insulation design in respect of insulation coordination because it has shield plate effect to even impulse oscillation. (c) There is a disadvantage to cause leakage flux to increase in Convex type winding, however, the constancy of electric loadings in a design in spite of BIL stepping up restricts the increase of leakage flux to some extent.

  • PDF

3차원 유한요소법을 이용한 비접촉 전력 전달 장치 특성 해석 (Characteristic analysis of contact-less energy transmission system using 3D finite element method)

  • 우경일;박한석;조윤현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.803-805
    • /
    • 2004
  • This paper proposes the calculation method of magnetic coupling coefficient of the contact-less energy transmission system by 3D finite element method with a variation of the secondary core positions. The primary, secondary self and leakage inductances and the capacitances of a resonant circuit are calculated by the finite element analysis results. From these values, the magnetic coupling coefficients are obtained. The secondary voltages and currents at the secondary core positions are calculated by using the resonant circuit and compared.

  • PDF