• Title/Summary/Keyword: Core recovery

Search Result 203, Processing Time 0.024 seconds

Zero-Voltage-Transition Synchronous DC-DC Converters with Coupled Inductors

  • Rahimi, Akbar;Mohammadi, Mohammad Reza
    • Journal of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.74-83
    • /
    • 2016
  • A new family of zero-voltage-transition converters with synchronous rectification is introduced in this study. Soft switching condition for all the converter operating points is provided in the proposed converters. The reverse recovery losses of the rectifier switch body diode are also eliminated. In comparison with the main switch voltage stress, the auxiliary switch voltage stress is reduced significantly. The auxiliary switch does not need the floating gate drive. The auxiliary inductor is coupled with the main converter inductor, and the leakage inductor is used as the resonance inductor. Thus, all inductors of the proposed converter can be implemented on a single core. The other features of the proposed converters include no extra voltage and current stresses on the main converter semiconductor elements. Theoretical analysis for a synchronous buck converter is presented in detail, and the validity of the theoretical analysis is justified with the experimental results of a prototype buck converter with 180 W and 80 V to 30 V.

A Study on the Mixed Implementation Method of Management Disposition and Cost Settlement by Public Participation in Urban Renewal Type Redevelopment Projects (도시정비형 재개발사업에서 공공참여에 의한 관리처분 및 원가정산 혼용 시행방식에 관한 고찰)

  • Moon, Myung-Yeol;Jeon, Sang-Hoon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.254-255
    • /
    • 2021
  • The urban renewal type redevelopment project is a project to improve the urban environment for the recovery of urban functions and revitalization of commercial districts in commercial and industrial areas. Urban regeneration projects are not progressing smoothly. The urban renewal type is not so for landowners, who require a high level of professional knowledge and experience to carry out smooth projects. In addition, the core part of business conflicts can be seen as the problem of management and disposal methods. Therefore, as landowners, etc. become the actual subjects, the public will take charge of project execution, but all development gains and losses will be attributed to the owner of the land, etc.

  • PDF

A Study on the Skin Temperature and Discomfort According to the Local Application of Ice Bag. (얼음주머니의 국소적 적용에 따른 피부체온 및 주관적 불편감에 관한 연구)

  • Kim Keum-Soon;Bang Kyung-Sook
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.1 no.1
    • /
    • pp.37-49
    • /
    • 1994
  • The purpose of this study was to measure the oral temperature, skin temperature, and subjective discomfort according to the application time of ice bag on thigh, head, and abdomen. This study was also intended to suggest nursing principles about ice bag application by exploring the recovery time of skin temperature after the removal of ice bag. The design of this study was $8{\times}3$ factorial design with one sample repeated measure. Here, the application time of ice bag(criteria, 5min, 10min, 20min, 30min, 40min, 50min, 60min) and the application site of ice bag(thigh, head, abdomen) were independent variables. The subjects were 10 university woman students, and data collection was made from July, 1 to August 30, 1992. Rubber ice bag halfly filled with ice was covered with towel and applied on thigh, head and abdomen in other three days. Before applying the ice bag, oral temperature and skin temperature were checked for criteria. After ice bag was applied, skin temperature, oral temperature and VAS score were checked at first 5 minutes elapsed, and every 10 minutes until 60 minutes. After that, ice bag was removed, and oral temperature and skin temperature were also measured every ten minutes until 60 minutes. In this study, skin temperature and core temperature were measured by thermistor probe, and subjective discomfort was measured by 200mm VAS (Visual Analogue Scale). Some of the findings were as follows : 1. There were significant differences in skin temperature among the three application sites of ice bag as time go by. It was most decreased to $15.87^{\circ}C$ in thigh, and $19.47^{\circ}C$ in abdomen at 50 minutes after the application of ice bag, whereas $26.1^{\circ}C$ at 40 minutes in head. Before the application of ice bag, skin temperature showed significant differences in three sites, so that they were compared after the criteria was covariated. In other words, there was significantly more decrease of skin temperature in thigh and abdomen than head, after ice bag was applied for 20 minutes and more. 2. There was no significant difference in core temperature among the three application sites of ice bag during the time of application 3. There was no significant difference in subjective discomfort (VAS) among the three application sites of ice bag. 4. After the removal of ice bag, the recovery of skin temperature was significantly different in three sites during first 30 minutes. In head, skin temperature came up to criteria at 30 minutes after the removal of ice bag, but it was not recovered In thigh and abdomen even 60 minutes elapsed. 5. After the removal of ice bag, there was no significant difference in oral temperature among the three application sites of ice bag. 6. There was significant correlation between the skin temperature and VAS score only in thigh. In conclusion, it is suggested that head in more suitable site for the application of ice bag if it is used for the relief of fever or pain. When we apply ice bag on thigh or abdomen for the relief of pain, careful attention is required.

  • PDF

Gas Hydrate Exploration by using PCS(Pressre Core Sampler): ODP Leg 204 (압력코어를 이용한 가스 하이드레이트 탐사: ODP Leg 204)

  • Lee Young-Joo
    • Economic and Environmental Geology
    • /
    • v.38 no.2 s.171
    • /
    • pp.165-176
    • /
    • 2005
  • Natural gas in deep sediment may occur in three phases based on the physical and chemical conditions. If the concentration of gas in pore water is less than the solubility, gas is dissolved. If the concentration of gas is greater than its solubility (water is saturated or supersaturated with gas), gas occurs as a fee gas below the gas hydrate stability Lone (GHSZ) and is present as solid hydrate within the GHSZ. The knowledge of gas concentration in deep sediment appears critical to determine the phase of natural gases and to understand the formation and distribution of gas hydrate. However, reliable data on gas concentration are usually available only from the upper section of marine sediment by the headspace gas technique, which is widely used for sampling of gases from the sediments. The headspace gas technique represents only a fraction of gases present in situ because sediments release most of the gases during recovery and sampling. The PCS (Pressure Core Sampler) is a downhole tool developed to recover a nominal $1{\cal}m$ long, $4.32{\cal}cm$ diameter core containing $1,465cm^3$ of sediment, pore water and gas at in situ pressure up to 68.9 MPa. During Leg 204, the PCS was deployed at 6 Sites. In situ methane gas concentration and distribution of gas hydrate was measured by using PCS tool. Characteristics of methane concentration and distribution is different from site to site. Distribution of gas hydrate in the study area is closely related to characteristics of in situ gas concentration measured by PCS.

A Study on the Vent Path Through the Pressurizer Manway and Steam Generator Manway under Loss of Residual Heat Removal System During Mid-loop Operation in PWR (가압경수로의 부분충수 운전중 잔열제거계통 기능 상실사고시 가압기와 증기발생기 Manway 유출유로를 이용한 사고완화에 관한 연구)

  • Y. J. Chung;Kim, W. S.;K. S. Ha;W. P. Chang;K. J. Yoo
    • Nuclear Engineering and Technology
    • /
    • v.28 no.2
    • /
    • pp.137-149
    • /
    • 1996
  • The present study is to analyze an integral test, BETHSY test 6.9c, which represent loss of RURS accident under mid-loop operation. Both the pressurizer manway and the steam generator outlet plenum manway are opened as vent paths in order to prevent the system from pressurization by removing the steam generated in the core. The main purposes are to gain insights into the physical phenomena and identify sensitive parameters. Assessment of capability of CATHARE2 prediction can be established the effective recovery procedures using the code in an actual plant. Most of important physical phenomena in the experiment could be predicted by the CATHARE2 code. The peak pressure in the upper plenum is predicted higher than experimental value by 7 kPa since the differential pressure between the pressurizer and the surge line is overestimated. The timing of core uncovery is delayed by 500 seconds mainly due to discrepancy in the core void distribution. It is demonstrated that openings of the pressurizer manwey and the steam generator manway can prevent the core uncovery using only gravity feed injection. Although some disagreements are found in the detailed phenomena, the code prediction is considered reasonable for the overall system behaviors.

  • PDF

Photoluminescence Quenching and Recovery of the CdSe Nanocrystals by Metal Ions (금속이온에 의한 CdSe 나노결정의 형광 소광 및 회복 특성)

  • Bang, Jiwon;Kim, Bomi;Koo, Eunhae;Kim, Sungjee
    • Journal of the Korean Chemical Society
    • /
    • v.60 no.2
    • /
    • pp.131-136
    • /
    • 2016
  • Copper ion induced photoluminescence (PL) quenching dynamics and recovery of the PL by zinc ions were investigated for CdSe based nanocrystals. When copper ions were added, CdSe quantum dots showed fast and dramatically PL quenching whereas PL of CdSe nanorod gradually decreased. In the presence of zinc ions, the PL of CdSe/CdS (core/shell) nanocrystals that have quenched by copper ions was efficiently recovered. It showed that the PL intensity of nanocrystals increased by 50% in a solution containing 1 μM zinc ions. The PL intensity was increasing with increasing zinc ions, and could be described by Langmuir binding isotherm model. We showcase that the CdSe based nanocrystals can be used as fluorescence turn-on sensor.

Investigation on Strength Recovery after Repairing Impact Damaged Aircraft Composite Laminate (항공기 복합재 라미네이트의 충격 손상 부위 유지 보수 후 강도 복원 평가)

  • Kong, Chang-Duk;Park, Hyun-Bum;Lee, Kyung-Sun;Shin, Sang-Jun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.9
    • /
    • pp.862-868
    • /
    • 2010
  • Development of a small scale aircraft has been carried out for the BASA(Bilateral Aviation Safety Agreement) program in Korea. This aircraft adopted all the composite structures for environmental friendly by low fuel consumption due to its lightness behavior. However the composite structure has s disadvantage which is very weak against impact due to foreign object damages. Therefore the aim of this study is focusing on the damage evaluation and repair techniques of the aircraft composite structure. The damages of composite laminates including the carbon/epoxy UD laminate and the carbon/epoxy fabric face sheets-honeycomb core sandwich laminate were simulated by a drop weight type impact test equipment and the damaged specimen were repaired using the external patch repair method after removing damaged area. The compressive strength test and analysis results after repairing the impact damaged specimens were compared with the compressive strength test and analysis results of undamaged specimens and impact damaged specimens. Finally, the strength recovery capability by repairing were investigated.

Effects of Low-Dose Aspirin Therapy on Thermoregulation in Firefighters

  • McEntire, Serina J.;Reis, Steven E.;Suman, Oscar E.;Hostler, David
    • Safety and Health at Work
    • /
    • v.6 no.3
    • /
    • pp.256-262
    • /
    • 2015
  • Background: Heart attack is the most common cause of line-of-duty death in the fire service. Daily aspirin therapy is a preventative measure used to reduce the morbidity of heart attacks but may decrease the ability to dissipate heat by reducing skin blood flow. Methods: In this double-blind, placebo-controlled, crossover study, firefighters were randomized to receive 14 days of therapy (81-mg aspirin or placebo) before performing treadmill exercise in thermal-protective clothing in a hot room [$38.8{\pm}2.1^{\circ}C$, $24.9{\pm}9.1%$ relative humidity (RH)]. Three weeks without therapy was provided before crossing to the other arm. Firefighters completed a baseline skin blood-flow assessment via laser Doppler flowmetry; skin was heated to $44^{\circ}C$ to achieve maximal cutaneous vasodilation. Skin blood flow was measured before and after exercise in a hot room, and at 0 minutes, 10 minutes, 20 minutes, and 30 minutes of recovery under temperature conditions ($25.3{\pm}1.2^{\circ}C$, $40.3{\pm}13.7%\;RH$). Platelet clotting time was assessed before drug administration, and before and after exercise. Results: Fifteen firefighters completed the study. Aspirin increased clotting time before and after exercise compared with placebo (p = 0.003). There were no differences in absolute skin blood flow between groups (p = 0.35). Following exercise, cutaneous vascular conductance (CVC) was $85{\pm}42%$ of maximum in the aspirin and $76{\pm}37%$ in the placebo groups. The percentage of maximal CVC did not differ by treatment before or after recovery. Neither maximal core body temperature nor heart rate responses to exercise differed between trials. Conclusion: There were no differences in skin blood flow during uncompensable heat stress following exercise after aspirin or placebo therapy.

Available Technology and Integrated Management Plan for Energy-positive in the Sewage Treatment Plant (에너지 생산형 하수처리장을 위한 가용 기술과 통합관리 방안)

  • Song, Minsu;Kim, Hyoungho;Bae, Hyokwan
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.1
    • /
    • pp.55-68
    • /
    • 2020
  • Because of the intensified environmental problems such as climate change and resource depletion, sewage treatment technology focused on energy management has recently attracted attention. The conversion of primary sludge from the primary sedimentation tank and excessive sludge from the secondary sedimentation tank into biogas is the key to energy-positive sewage treatment. In particular, the primary sedimentation tanks recover enriched biodegradable organic matter and anaerobic digestion process produces methane from the organic wastes for energy production. Such technologies for minimizing oxygen demand are leading the innovation regarding sewage treatment plants. However, sewage treatment facilities in Korea lack core technology and operational know-how. Actually, the energy potential of sewage is higher than sewage treatment energy consumption in the sewage treatment, but current processes are not adequately efficient in energy recovery. To improve this, it is possible to apply chemically enhanced primary treatment (CEPT), high-rate activated sludge (HRAS), and anaerobic membrane bioreactor (AnMBR) to the primary sedimentation tank. To maximize the methane production of sewage treatment plants, organic wastes such as food waste and livestock manure can be digested. Additionally, mechanical pretreatment, thermal hydrolysis, and chemical pretreatment would enhance the methane conversion of organic waste. Power generation systems based on internal combustion engines are susceptible to heat source losses, requiring breakthrough energy conversion systems such as fuel cells. To realize the energy positive sewage treatment plant, primary organic matter recovery from sewage, biogas pretreatment, and co-digestion should be optimized in the energy management system based on the knowledge-based operation.

Effect of multiple-failure events on accident management strategy for CANDU-6 reactors

  • YU, Seon Oh;KIM, Manwoong
    • Nuclear Engineering and Technology
    • /
    • v.53 no.10
    • /
    • pp.3236-3246
    • /
    • 2021
  • Lessons learned from the Fukushima Daiichi nuclear power plant accident directed that multiple failures should be considered more seriously rather than single failure in the licensing bases and safety cases because attempts to take accident management measures could be unsuccessful under the high radiation environment aggravated by multiple failures, such as complete loss of electric power, uncontrollable loss of coolant inventory, failure of essential safety function recovery. In the case of the complete loss of electric power called station blackout (SBO), if there is no mitigation action for recovering safety functions, the reactor core would be overheated, and severe fuel damage could be anticipated due to the failure of the active heat sink. In such a transient condition at CANDU-6 plants, the seal failure of the primary heat transport (PHT) pumps can facilitate a consequent increase in the fuel sheath temperature and eventually lead to degradation of the fuel integrity. Therefore, it is necessary to specify the regulatory guidelines for multiple failures on a licensing basis so that licensees should prepare the accident management measures to prevent or mitigate accident conditions. In order to explore the efficiency of implementing accident management strategies for CANDU-6 plants, this study proposed a realistic accident analysis approach on the SBO transient with multiple-failure sequences such as seal failure of PHT pumps without operator's recovery actions. In this regard, a comparative study for two PHT pump seal failure modes with and without coolant seal leakage was conducted using a best-estimate code to precisely investigate the behaviors of thermal-hydraulic parameters during transient conditions. Moreover, a sensitivity analysis for different PHT pump seal leakage rates was also carried out to examine the effect of leakage rate on the system responses. This study is expected to provide the technical bases to the accident management strategy for unmitigated transient conditions with multiple failures.