• Title/Summary/Keyword: Copper-tube

Search Result 264, Processing Time 0.026 seconds

Deformation of the Tubes in Copper/Brass Radiator with Rise of Temperature and Pressure (온도 및 압력상승에 따른 동/황동 라디에터 튜브의 변형)

  • 정명진
    • Journal of the Korean Society of Safety
    • /
    • v.8 no.4
    • /
    • pp.16-20
    • /
    • 1993
  • The combined effect of increased pressure/temperature and the reduced material thicknesses act to increase the stress on the radiator componets. The design life of the radiator is influenced by the cyclic stresses and corrosion, which act to weaken the materials, radiator mechanical failure occurs when a tube or solder Joint ruptures, causing coolant loss or insufficient heat rejection. Therefore, in this study, through strain measurement of the tubes in copper/brass radiator, the strain distribution of the tubes in radiator as function of temperature and pressure is obtained.

  • PDF

Efficient Fault Location Detecting Mechanism for Optical Submarine Cable (해저광케이블 고장지점 탐지기법)

  • Park, Hong-Tae;Yoo, Jae-Duck;Yoon, Suk-Min;Jo, Gi-Rayng;Shin, Hyun-Sik
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.1 no.1
    • /
    • pp.63-69
    • /
    • 2006
  • The optical submarine cable has a long distance cable and the repeater for optical amplification compared to territorial optical cable so conventional OTDR utilization for the optical submarine cable is limited. in case the optical core in the optical submarine cable system cut, by using Coherent OTDR that utilize OTDR path in repeater the cable fault point can be detected and in case the faulty of the copper tube in the cable that provide power for the repeater to amplify optical signal, the ways using the current/voltage characteristic, the capacitance per Km and so on is required. this report suggest efficient fault location detecting mechanism by categorized cable fault type.

  • PDF

Cooling Heat Transfer Characteristics of $CO_2$ on Tube Geometry of Inclined Helical Coil Type Gas Coolers (경사진 헬리컬 코일형 가스냉각기의 관형상에 따른 $CO_2$ 냉각 열전달 특성)

  • Son, Chang-Hyo;Oh, Hoo-Kyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.9
    • /
    • pp.640-646
    • /
    • 2007
  • The cooling heat transfer coefficient of $CO_2$ (R-744) for tube and coil diameter (CD), inclined angle of tube and coil pitch of inclined helical coil type copper tubes were investigated experimentally. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and a inclined helical coil type gas cooler (test section). The test section consists of a smooth copper tube of 2.45 and 4.55 mm inner diameter (ID). The refrigerant mass flukes were varied from 200 to 800 [$kg/m^2s$] and the inlet pressures of gas cooler were 7.5 to 10.0 [MPa]. The heat transfer coefficients of $CO_2$ in inclined helical coil tube with 2.45 mm ID are $5{\sim}10.3%$ higher than those of 4.55 mm. The heat transfer coefficients of 41.35 mm CD are $8{\sim}32.4%$ higher than those of 26.75 mm CD. Comparison between $45^{\circ}\;and\;90^{\circ}$ of coil angle, the heat transfer coefficients of $45^{\circ}$ are higher than those of $90^{\circ}$. For coil pitch of gas cooler, the heat transfer coefficients of inclined helical coil gas cooler with coil pitch of 5 mm are similar to those of 10 and 15 mm.

Improving hydrophilic and antimicrobial properties of membrane by adding nanoparticles of titanium dioxide and copper oxide

  • Khosroyar, Susan;Arastehnodeh, Ali
    • Membrane and Water Treatment
    • /
    • v.9 no.6
    • /
    • pp.481-487
    • /
    • 2018
  • Membrane clogging or fouling of the membrane caused by organic, inorganic, and biological on the surface is one of the main obstacles to achieve high flux over a long period of the membrane filtration process. So researchers have been many attempts to reduce membrane fouling and found that there is a close relationship between membrane surface hydrophilicity and membrane fouling, such that the same conditions, a greater hydrophilicity were less prone to fouling. Nanotechnology in the past decade is provided numerous opportunities to examine the effects of metal nanoparticles on the both hydrophilic and antibacterial properties of the membrane. In the present study the improvement of hydrophilic and antimicrobial properties of the membrane was evaluated by adding nanoparticles of titanium dioxide and copper oxide. For this purpose, 4% copper oxide and titanium dioxide nanoparticles with a ratio of 0, 30, 50, and 70% of copper oxide added to the polymeric membrane and compare to the pure polymeric membrane. Comparison experiments were performed on E. coli PTCC1998 in two ways disc and tube and also to evaluate membrane hydrophilic by measuring the contact angle and diameter of pores and analysis point SEM has been made. The results show that the membrane-containing nanoparticle has antibacterial properties and its impact by increasing the percentage of copper oxide nanoparticles increases.

Evaluation for the Usefulness of Copper Filters according to Mode Change in Digital Radiography System (DR 시스템에서 모드 변화에 따른 구리필터의 유용성 평가)

  • Kim, Jae-Kyeom;Kim, Jeong-Koo
    • Journal of radiological science and technology
    • /
    • v.44 no.1
    • /
    • pp.39-46
    • /
    • 2021
  • This study confirmed the usefulness of the copper filter according to the mode change by comparing and analyzing the energy change according to the application of the copper filter and the change in effective dose and image quality according to the distance to the subject in the DR(Digital Radiography) system. The average energy increased when the copper filter was applied and the reduction rate by 50% of mAs was increased as the thickness of the copper filter increased according to the application of the 10 kVp rule in AEC mode. The effective dose decreased as the thickness increased when the copper filter was applied in AEC(Automatic Exposure Control) mode and manual mode according to the application of the 10 kVp rule, and the decrease rate decreased with increasing 10 kVp increments. As a result of analyzing the dicom images for AEC mode and manual mode with Image J. the PSNR(Peak Signal to Noise Ratio) values were approximate values of less than 30 dB for each mode and for each copper filter thickness. When the copper filter was applied, the average energy increased, so when the 10 kVp rule was applied, the mAs for each mode could be reduced, and the effective dose could also be reduced. However, as the distance and tube voltage increased, the reduction rate of mAs decreased, and the quality of the image was found to decrease when the copper filter was applied, but there was no difference in quality of the image when the copper filter thickness increased.

An experimental study of magnetic diffusion in Bi-2212 High-Tc supercondutor tube (Bi-2212 고온초전도체 튜브의 자기확산에 관한 연구)

  • 정성기;설승윤
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.2
    • /
    • pp.66-70
    • /
    • 2003
  • Transient magnetic diffusion process in a melt-cast Bi2Sr2CaCu20X(Bi-2212) tube was studied by experimental and numerical analyses. The transient diffusion partial differential equation is transformed into an ordinary differential equation by integral method. The penetration depth of magnetic field into a superconducting tube is obtained by solving the differential equation numerically. The results show that the penetration depth as a function of time which is somewhat different from the results by Bean's critical state model. The reason of the difference between the present results and that of Bean's model is discussed and compared in this paper. This experiment measure the magnetic flux density in the supercondutor after supply direct-current of Bi-2212 rounded by copper coil. This study was discussed of valid of a previous numerical solution which is compared by the penetrate time and the magnetic flux density difference of between the present results and the numerical solution.

A Study on the Collector Characteristics of Evacuated Double Glass Tube by Artificial Sun (인공태양에 의한 이중 진공 유리관의 집열특성에 관한 연구)

  • Nam, Yong-Han;Shin, Jae-Ho;Mo, Joung-Gun;Chung, Han-Shik;Jeong, Hyo-Min;Suh, Jeong-Se
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1542-1547
    • /
    • 2003
  • This paper represents the solar collector performance with type of an evacuate double glass, and a copper tube was installed in center of collector to get a solar thermal energy. The one module of solar collector and artificial sun were used in this experiment The distance between artificial sun and solar collector was fixed at 0.5m, and this experimental condition was focused on winter season. The experiments were carried out. three times for getting a accurate data and the heat amount of one module evacuate d solar collector was estimated at out. 48 kcal/hr.

  • PDF

Experimental study of heat transfer and pressure drop characteristics for flow of water inside circular smooth and micro-fin tubes (평활관 및 미세휜관 내에서의 물을 이용한 열전달 및 압력강하 특성에 관한 실험)

  • Park, H.B.;You, S.M.;Youn, B.;Yoo, K.C.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.4
    • /
    • pp.454-461
    • /
    • 1997
  • Heat transfer and pressure drop for single phase flow of water in circular smooth and micro-fin tubes are measured. Copper tubes of 9.52 and 7mm outer diameter were used. The internal roughness in micro-fin tubes was formed by spiral grooves having $25^{\circ}$ helx angle, 0. 12mm fin height and 0.454mm pitch in 9.52mm tubes; $18^{\circ}$ helix angle, 0.15mm fin height and 0.322mm pitch in 7mm tubes. The measured friction factor and heat transfer coefficient are compared with relevant previous works, and the correlations for micro-fin tube are developed.

  • PDF

Comparison of Collecting Performance according to Contact Types of Heatpipe in Vacuum Tube Type Solar Collector (진공관형 집열기 히트파이프 접촉방식에 따른 집열성능 비교)

  • Yun, Ji-Hun;Jeong, In-Guk;Yi, Chung-Seob;Chung, Kyung-Teak;Suh, Jeong-Se
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.6
    • /
    • pp.122-127
    • /
    • 2011
  • In this study, it was compared collecting performance according to contact types between heatpipe and manifold of vacuum tube type solar collector. Between two types, direct contact type is better in collecting performance. On the other hand, Indirect type have advantage in maintenance. In the result of numerical analysis, As the temperature of heatpipe and flow rate of working fluid increased, difference of outlet mean temperature of two types became large. Also, it could be confirmed, as contact resistance between heatpipe and copper tube in indirect type increased, the difference increased too. Useful data in selection and design in vacuum tube type solar collector were proposed by the results of numerical analysis.

A Study on Finned Tube Used in Turbo Refrigerator(II) - on boiling heat transfer - (터보 냉동기용 핀 튜브에 관한 연구(II) - 비등 열전달에 관하여 -)

  • Han, Kyu-Il;Kim, Si-Young;Cho, Dong-Hyun
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.5 no.2
    • /
    • pp.119-127
    • /
    • 1993
  • This work studies for heat transfer and pressure drop performance of integral inner and outer fin tubes, designed to enhance the heat transfer performance of smooth tubes for in recipro and turbo refrigerator or high performance compact heat exchangers. Eight different inner spiral fin copper tubes with integral fin at outside surfaces were employed to improve boiling heat transfer coeffcient. For comparison, tests were made using a plain tube having the inside diameter and an outside diameter equal to that at the root of the fins for the finned tubes. Pool boiling heat transfer is investigated experimentally and theoretically on single tube arrangement. The refrigerant evaporates at a saturation state of 1 bar on the outside tube surface heated by hot water. The refrigerant R11 ($CFCl_3$) was used at a pressure of $P_s=1bar$ as a convenient test fluid with a boiling temperature of $T_s=23.6^{\circ}C$. The observed heat transfer enhancement of boiling for finned tubes significantly exceeded that to be expected on grounds of increased area. The maximum Vapor - side enhancement(i.e., vapor - side heat transfer coefficient of finned tube/vapor - side coefficient for plain tube) was found to be around 4 at 1299fpm - 30grooves tube.

  • PDF