• 제목/요약/키워드: Copper-tube

검색결과 264건 처리시간 0.032초

선회유동장에서 Al-Mg/물 마이크로 유동의 대류 열전달에 대한 실험적 연구 (An Experimental Study on the Convection heat Transfer of Al-Mg/water Micro Fluid in a Circular Tube with Swirl)

  • 장태현;김치원;길상철;이창환
    • 한국가시화정보학회지
    • /
    • 제10권3호
    • /
    • pp.16-20
    • /
    • 2012
  • In the past decades, extensive studies on convection heat transfer on internal flow have been conducted by using high specific surface area, by increasing heat transfer coefficient and swirl flow, and by improving the transport properties. In this study, we applied a tangential slot swirl generator to improve heat transfer in a horizontal circular copper tube. The Al-Mg particles (approximately $100{\mu}m$ to $130{\mu}m$) were employed for this experimental work. The copper tube was heated uniformly by winding a heating coil with a resistance of 9ohm per meter for heat transfer. Using Al-Mg particles, experiments were performed in the Reynolds number range of 5,000 to 13,130, with and without swirl. Experimental data transfers or comparisons between Nusselt numbers with and without swirl along the test tube and Reynolds numbers are presented. The Nusselt number is improved by increasing Reynolds numbers or swirl intensities along the test tube.

히트파이프 응축부의 초음파 분무냉각에 관한 실험적 연구 (An Experimental Study on Ultrasonic Spray Cooling of Heat Pipe Condenser)

  • 김영찬;한양호
    • 설비공학논문집
    • /
    • 제16권1호
    • /
    • pp.77-83
    • /
    • 2004
  • In this study, the spray cooling heat transfer and working characteristics of the screen wick heat pipe with ultrasonic spray cooling system in condenser were experimentally investigated. The heat pipe was made of copper tube 300 mm long with inner diameter of 11.1 mm. The evaporator and condenser lengths of heat pipe were 40, 200 mm and the wick structure consists of two layer of 100 mesh copper screen. The experimental results show that the ultrasonic spray cooling increases the heat transfer rate on the condenser surface, and the total thermal resistance of heat pipe system decreases remarkably. A comparison is made for the two working fluids, water and ethanol. The surface temperature of the ethanol tube in evaporator section becomes higher than that of the water tube. Thus, the experimental result shows that water is more useful than ethanol as the working fluid because of increasing the operational limit within this experimental conditions.

방전가열형 구리증기레이저의 개발 (Development of the Discharge Heated Copper Vapor Laser)

  • 임창환;차병헌;성낙진;이종민
    • 한국광학회지
    • /
    • 제1권1호
    • /
    • pp.28-32
    • /
    • 1990
  • 방전가열형 구리증기레이저를 제작하였으며 그 동작특성을 조사하였다. 레이저관으로는 내경 25mm, 길이 106cm 인 고순도(99.8%) 알루미나관을 이용하였다. 방전전극은 molybdenum 튜브로 제작하였으며 전극간의 거리는 108cm 이었다. Ne 가스압력 40mbar, 충전전압 10kV, 반복률 5KHz, 레이저관 내부온도 $1500^{\circ}C$일 때 평균출력 10W를 얻었다.

  • PDF

Some Aspects of Experimental in-Tube Evaporation

  • Ha, Sam-Chul
    • Journal of Mechanical Science and Technology
    • /
    • 제14권5호
    • /
    • pp.537-546
    • /
    • 2000
  • The heat transfer characteristics of refrigerant-oil mixture for horizontal in-tube evaporator have been investigated experimentally. A smooth copper tube and a micro-fin tube with nominal 9.5 mm outer diameter and 1500 mm length were tested. For the pure refrigerant flow, the dependence of the axial heat transfer coefficient on quality was weak in the smooth tube, but in the micro-fin tube, the coefficients were 3 to 10 times greater as quality increases. Oil addition to pure refrigerant in the smooth tube altered the flow pattern dramatically at low mass fluxes, with a resultant enhancement of the wetting area by vigorous foaming. The heat transfer coefficients of the mixture for low and medium qualities were increased at low mass fluxes. In the micro-fin tube, however, the addition of oil deteriorates the local heat transfer performance for most of the quality range, except for low quality. The micro-fin tube consequently loses its advantage of high heat transfer performance for an oil fraction of 5%. Results are presented as plots of local heat transfer coefficient versus quality.

  • PDF

접합계면반응에 미치는 직류전원부하의 영향 (Effect of applying a DC voltage on the interfacial reactions at the zirconia to copper interface)

  • 김성진;김인수;오명훈;최환
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 1996년도 특별강연 및 춘계학술발표 개요집
    • /
    • pp.6-9
    • /
    • 1996
  • The Joining of copper rod and zirconia tube was carried out in Ar gas atmosphere. There are two type of the joining. The one is the reaction bond consisting of Cu and zirconia was dominated by surface reaction wi th a undetctable very thin layer. It was found that copper elements were diffused to zirconia side, but that most of Z $r^{4+}$ ions were not diffused to copper side. This result means application of a DC voltage to migrate oxygen to the copper/zirconia interface can oxidize metal at the copper /zirconia interface, and the bonding reaction between zirconia and copper oxide may occur. The other is the reaction bonding was dominated by interdiffusion with a very thick interface layer. This result means application of a DC voltage can reduce zirconia at the interface. The bonding reaction is to be an alloying between Zr and Cr.

  • PDF

Sulfa 제-Cu 착화합물의 형성에 관하여 III. Copper Sulfa-drug Complex 의 세균감수성 (Studies on the Formation of Copper Complex of Sulfa-Drug III. Study on the Sensitivity of Copper Sulfa-Drug Complex on Microorganism.)

  • 이왕규
    • 약학회지
    • /
    • 제9권1_2호
    • /
    • pp.8-13
    • /
    • 1965
  • The sensitivity on microorganisms of ten sulfa-drugs and their Cu-complexes was observed. Ericsson's disc method and modified tube dilution method were applied. Dimethylformamide was used for solvent of sulfa drugs. In general, original sulfa-drugs showed more sensitive patterns than its Cu-complexes except sulfadimethoxine-Cu complex which showed more sensitive patterns than its original drug with disc method.

  • PDF

Hair Pin Bending Machine을 이용한 동 튜브 굽힘 성형가공에 관한 연구 (A study about shape processing for the bend of the Copper-Tube that use Hair Pin Bending Machine)

  • 강흥식;김동성;허신;홍성인
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1705-1708
    • /
    • 2003
  • The purpose of this study is to investigate the manufacturing technique on the U type Draw-Bending of inner grooved tube. This bending process make the U shape tube by Hair Pin Bending machine. The U type tube requires the quality of product that satisfy sufficient conditions for a heat exchanger. The mandrel components act the important roles that prevent wrinkles and keep the shape of cross section of bended tube at bending process. We performed the FEM simulation using LS-DYNA software and the bending test of inner groove tube and then, compared bending simulation with bending test results about mandrel ball diameter, mandrel position and optimal clearance between mandrel and tube.

  • PDF

Evaporation of Water in an Aqueous Lithium Bromide Solution flowing over a Horizontal Tube

  • Kim, Dong-Kwan;Kim, Moo-Hwan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권3호
    • /
    • pp.57-62
    • /
    • 2001
  • Falling film heat transfer analyses with aqueous lithium bromide solution were performed to investigate the transfer characteristics of the copper tubes. Finned (knurled) tube and a smooth tube were selected as test specimens. Averaged generation fluxes of water and the heat flux were obtained. As the film flow rate of the solution increased, the generation fluxes of water decreased for both tubes due to the fact that the heat transfer resistance increased with the film thickness. The effect of the enlarged surface area at the knurled tube was supposed to be dominant at a small flow rate. The generation fluxes of water increased with the increasing degree of tube wall superheat. Nucleate boiling is supposed to occur at a wall superheat of 20K for a smooth tube, and at 10K for a knurled tube. The increased performance of the knurled tube was supposed to mainly come from the effect of the increased heating surface area.

  • PDF

케로신-공기 혼합물의 데토네이션 모델과 구조체 모델을 통한 금속관의 수치해석 (Numerical Analysis of Detonation of Kerosene-Air Mixture and Solid Structure)

  • 이영헌;곽민철;여재익
    • 한국추진공학회지
    • /
    • 제19권2호
    • /
    • pp.29-37
    • /
    • 2015
  • 본 연구는 케로신 연료를 사용하는 액체로켓엔진에서 발생할 수 있는 연소불안정으로 인하여 파괴될 수 있는 연소기의 손상을 수치적으로 모사하는 해석 모델의 기초연구이다. 연소불안정으로부터 야기 될 수 있는 케로신의 데토네이션은 1단계 아레니우스 식의 화학 반응식을 이용하였고, 구조체는 Johnson-Cook 강성모델을 활용하여 데토네이션으로 인한 금속관의 소성 변형을 모델링하였다. 금속관의 소성 변형에 의해 변화하는 유동장과 구조체의 스트레스를 노즐 형상과 관의 두께변화에 따라 해석하였다.