• Title/Summary/Keyword: Copper pipe

Search Result 176, Processing Time 0.032 seconds

Development of Bending Machine with High Efficiency and Precision Forming (고효율 배관용 정밀성형 벤딩머시인 개발)

  • Mun, Sang-Don
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.1
    • /
    • pp.7-14
    • /
    • 2011
  • Soft copper tube is one of the popular materials which are used for shipbuilding, automobiles, and freezing and HVAC equipment. However, these materials have problems that they cause occasionally outside wrinkle, spring back, wall thinning phenomena. In this study, to avoid these phenomena, was manufactured a mild materials devoted bending machine, which selected a bending method where the mandrel presses the pipe along with the sliding guide rail during bending process. During the course of confirming this performance, it was found that as the diameter of copper tube used for materials became smaller, the spring back phenomenon increased. And as the bending angle became larger, it became larger. In addition, we could manufacture mold products which scarcely generated wrinkle when bending copper tubes.

Analysis of Thermal Control Characteristics of VCHP by the Charging Mass of Non-Condensible Gas

  • Suh, Jeong-Se;Park, Young-Sik;Chung, Kyung-Taek;Kim, Byoung-Gi
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.14 no.4
    • /
    • pp.125-130
    • /
    • 2006
  • This study has been performed to investigate the thermal performance of variable conductance heat pipe (VCHP) with screen meshed wick. The active length of condenser section in a VCHP is varied by non-condensible gas, which controls the operating temperature, and the heat capacity of VCHP is controlled by the operating temperature. In this study, numerical analysis of the VCHP based on the diffusion model of non-condensible gas is done for the thermal control performance of VCHP. Water is used as a working fluid and nitrogen as a control non-condensible gas in the copper tube. As a result, the thermal conductance of VCHP has been compared with that of constant conductance heat pipe (CCHP) corresponding to the variation of operating temperature.

Theoretical Analysis of the Pressure Drop in Loop Heat Pipe by Sintered Porous Wick Structure (다공성소결윅구조에 따른 루프 히트파이프에서 압력손실의 이론적 분석)

  • Lee, K.W.;Lee, W.H.;Park, K.H.;Lee, K.J.;Chun, W.P.;Ihn, H.M.
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1225-1230
    • /
    • 2004
  • In this paper, the pressure drops were investigated according to the sintered porous wick structure in loop heat pipe(LHP) by theoretical analysis. LHP has the wick only in evaporator for the circulation of working fluid, so utilizes porous wick structure which pore diameter is very small for large capillary force. This paper investigates the effects of different parameters on the pressure drops of the LHP such as particle diameter of sintered porous wick, wick porosity, vapor line diameter, thickness of wick and heating capacity. Working fluid is water and the material of sintered porous wick is copper. According to the these different parameters, capillary pressure, pressure drop in wick were analized by theoretical design method of LHP.

  • PDF

A study on the characteristics of a frozen start up for a variable conductance heat pipe (가변전열 히트파이프의 저온 시동특성에 관한 연구)

  • Hong, Sung-Eun;Kang, Hwan-Kook;Cho, Kwang-Cheal
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.339-345
    • /
    • 2006
  • This these was conducted to investigate tile characteristics of a frozen start up for a VCHP which has water as a working fluid and Nitrogen as a non-condensible gas. The tested heat pipe was made of a copper tube with the outer diameter of 12.7 mm, the length of 340 mm, and the sintered metal wick had the thickness of 0.7 mm. This experiment was conflicted under the thermal load, inclined angle and cooling conditions.

  • PDF

A Study on temperature behavior of pulsating heat pipe with different diameter in evaporator (증발부 내경 변화에 따른 진동형 히트파이프의 온도 거동에 관한 연구)

  • Kim, Jihoon;Park, Chulwoo;Shah, Syed Abdullah;Kim, Daejoong
    • Journal of the Korean Society of Visualization
    • /
    • v.17 no.1
    • /
    • pp.10-18
    • /
    • 2019
  • In this study, the temperature behavior of Pulsating Heat Pipe (PHP) according to the diameter change were studied by limiting the diameter change to only the evaporator. To investigate operation of PHP in various heat input, heat input power was increased from 10 to 120 W. The results show operation can be divided into 3 regimes by temperature behavior. Thermal resistance was increased before start-up and decreased with increasing heat input. At 110 W heat input, thermal conductivity of 2 mm PHP was 8 .times higher compare to thermal conductivity of copper. Further, to investigate details of temperature behavior in higher heat input, FFT analysis was conducted. Based on the results, when the deviation of peak frequency in each section is lowest, the thermal resistance has lowest value.

Characteristics of Hydration Heat Control of Mass Concrete using Pulsating Heat Pipe in the Winter Season (진동형 히트 파이프를 이용한 매스 콘크리트의 겨울철 수화열 제어 특성)

  • Yang, Tae-Jin;Kim, Jeung-Hoon;Youm, Chi-Sun;Kim, Myung-Sik;Kim, Jong-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.2
    • /
    • pp.169-174
    • /
    • 2007
  • In process of reinforced concrete (RC) box structure, the heat of hydration may cause serious thermal cracking. This paper reports results of hydration heat control in mass concrete using the oscillating heat pipe. There were three RC box molds ($1.2m{\times}1.8m{\times}2.4m$) which were different from each other. One was not equipped with pulsating heat pipe. The others were equipped with pulsating heat pipe. All of them were cooled with natural air convection. The pulsating heat pipe was composed of 10 turns of serpentine type copper pipe whose outer and inner diameters were 4 and 2.8 mm respectively. The working fluid was R-22 and charging ratio was 40% by volume. The temperature of the concrete core was approximately $55^{\circ}C$ in the winter without pulsating heat pipe. For a concrete with pulsating heat pipe, however, the temperature difference with the outdoor one reduced up to $12^{\circ}C$. The index figure of crack was varied from 0.75 to 1.38.

A Study on the Characteristics of an Arc-Inducing Driven Rod with Needles (아크유도형 침부 접지봉의 특성 연구)

  • 박중신;정종욱;곽희로
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.1
    • /
    • pp.118-123
    • /
    • 2000
  • This paper describes the characteristics of a newly suggested arc-inducing driven rod with needles which could effectively spread out both the failure current with power frequency and the lightning current. The structural characteristic of the driven rod was that needles were attached on the surface of the conventional shaped driven rod and the driven rod with needles was installed inside of a copper pipe.As a result of analyzing the characteristics of this suggested driven rod when it was employed as the driven rod of an arrester in distribution system, it was verified that the primary voltage of the arrester was reduced by effectively exhausting the electrical energy since the arc occurred between the needle and the copper pipe.

  • PDF

Experimental study of the heat pipe phenomenon in porous media heated from above (상부가열인 다공물질내의 열파이프 현상에 관한 실험적 연구)

  • 이진호;김홍제;함윤영;남궁규완
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.4
    • /
    • pp.825-832
    • /
    • 1988
  • An experiment was performed to study the heat pipe phenomenon of porous media heated above at one-dimensional steady state for the range of heat flux, 300 W/ $m^{2}$ ~ 2000w/ $m^{2}$. Glass beads, sand, and copper particles were used as porous media and distilled water was used as a working fluid. Result of experiment shows that the length of the two-phase zone increases with the decreasing particle size for the same heat flux. At relatively lower heat flux the length of the two-phase zone increases with the increasing heat flux, which contradicts the result of earlier work. However, its length remains nearly constant when the heat flux increases above a certain value. The length of the two-phase zone is proportional to the product of the heat flux by the hydrostatic capillary height under the limited value on heat flux, that is, $l_{t}$ = A(q. $l_{cap}$)+B, q.leg.1/A(C+B/ $l_{cap}$) where A is 1.7*10$^{-4}$ $m^{2}$/w, B is 1.9*10$^{-2}$ m, and C is 0.43 for copper particles and 0.31 for glass beads and sand.d.d.d.

Effect of Air-earth Heat Exchange System on Growth of Leafy Lettuce in Greenhouse (온실내 잉여에너지 이용을 위한 지중 열교환 시스템의 상추 재배 효과)

  • Paek, Yee;Jeon, Jong-gil;Yun, Nam-kyu;Kang, Geum-Choon;Lee, Si-Young
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.4
    • /
    • pp.71-76
    • /
    • 2011
  • Earth to air heat exchangers made by iron, aluminium, copper and poly-ethylene pipe for single greenhouse heating were experimented and blowers. Earth to air heat exchanger was installed by pipelines in earth tube at 70cm depths and air blower was the heating capacity 3kW/h, As the result, Temperature difference due to temperature history of the inlet and outlet air on the various type in earth tube in greenhouse showed that air temperature at the various type in earth tube, comparison tube were make no difference respectively. Under the experimental condition, heat fluxes and heating load were showed 6,800Kcal/h, 19,699kcal/h generally yield of Lactuca Sativa cultured during days of sowing 90day in greenhouse using copper pipe was 170% incleased.

Manufacturing and Operating Performance of the Heat Pipe with Sintered Wick (소결윅 히트파이프의 제작 및 작동성능)

  • Yun, Ho-Gyeong;Moon, Seok-Hwan;Ko, Sang-Choon;Hwang, Gunn;Choy, Tae-Goo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.9
    • /
    • pp.1260-1266
    • /
    • 2002
  • In this study, to make an excellent heat pipe, the manufacturing technology of a sintered wick was investigated. Making a sintered wick is known to be very difficult but it has many advantages. For example, the porosity and pore size can be controlled and the capillary force is great. The mixture of copper and pore former powder was used as a wick material and ceramic-coated stainless steel was used as a mandrel which is necessary for vapor flow. To analyze the feature of the manufactured wick, not only porosity and pore size were measured but also the sintered structure was observed. A heat pipe with sintered wick was manufactured and the performance test of the heat pipe was performed in order to review cooling performance. The performance test results for the 4mm diameter heat pipe with the sintered wick shows the stability since the temperature difference between a evaporator and a condenser of the heat pipe is less than 4.4$^{\circ}C$, and thermal resistance is less than 0.7$^{\circ}C$/W, In the meantime the composite wick that is composed with sintered and woven wire was also examined. The heat transfer limit of the heat pipe with composite wick was enhanced about 51%~60% compare to the one with sintered wick.