• Title/Summary/Keyword: Cooling-to-Heating load ratio

Search Result 35, Processing Time 0.025 seconds

Economic Analysis of Cooling-Heating System Using Ground Source Heat in Horticultural Greenhouse (시설원예의 지열냉·난방시스템 경제성 분석)

  • Ryoo, Yeon-Su;Joo, Hye-Jin;Kim, Jin-Wook;Park, Mi-Lan
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.6
    • /
    • pp.60-67
    • /
    • 2012
  • Government Geothermal Cooling-Heating Projects has made efforts to reduce GHG(Greenhouse Gas) emissions and to manage cost of greenhouse farm households. This study evaluated the economic benefits of heating load rate of change by comparing Geothermal Cooling-Heating System with the existing system(greenhouse diesel heating) in the Government Geothermal Cooling-Heating Projects. Economic analysis results shows that, 1) When installing the Cooling-Heating system according to the ratio of 70% heating load in policy standards, the geothermal cooling-heating system has economic efficiency with greenhouse type or scale independent because the investment cost is recovered within 7 years. And It was more economic efficiency the ratio of 50% heating load than70% heating load. 2) When installing the Cooling-Heating system according to the glass greenhouse of the ratio of 90% heating load, pay period of investment cost is recovered within 5 years. Therefore it is necessary to apply flexible heating sharing according to greenhouse type or scale.

Performance Analysis of Water-to-Air Heat Pump System under Water Temperature and Load Ratio (열원 및 부하조건에 따른 물-공기 히트펌프 시스템의 성능분석)

  • Cho, Yong;Lee, Dong Keun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.194.2-194.2
    • /
    • 2011
  • Heating and cooling performance has been analyzed for the water-source heat pump system using raw water from Daechung reservoir. During heating operation from March to May, water temperature is not good condition for a heat source due to the higher atmospheric temperature. Avearged heating load ratio is only 14.3%, and the averaged unit COP and system COP are estimated to be 2.46 and 2.15 respectively. The COP is affected considerably by the water temperature, and the unit COP is increased from 2.16 at $5^{\circ}C$ to 2.95 at $11^{\circ}C$. Cooling performance is analyzed with the measured data from June to August. During cooling operation, raw water has lower temperature by 4. $5^{\circ}C{\sim}4.7^{\circ}C$ than the atmosphere. The load ratio is 39.2%, and the averaged unit COP and system COP are estimated to be 7.25 and 6.13 respectively. The heating COP is affected by the load ratio rather than water temperature. The COP is increased for 20%~40% load ratio, while is decreased for 40%~60% load ratio. It is estimated that the compressor operation combination for 3 (two constant speed and one inverter) compressors is changed for the load ratio.

  • PDF

Interaction Analysis between Cooling-to-Heating Load Ratio and Primary Energy Consumption of HVAC&R System for Building Energy Conservation (건물의 냉, 난방 부하비율과 HVAC&R 시스템 1차 에너지 소비량의 상관관계분석 및 합리적 설계방안 연구)

  • Cho, Jinkyun;Kim, Jinho;Lee, Suengjae;Kang, Hosuk
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.3
    • /
    • pp.113-122
    • /
    • 2015
  • HVAC&R systems account for more than 50% of the energy consumption of buildings. The purpose of this study is to propose an optimal design method for the HVAC&R system and to examine the possibility for the energy conservation of a selected system. The energy demand for cooling and heating is determined by using TRNSYS and HEET. By an interaction between total system efficiency and cooling-to-heating load ratio, the optimal HVAC&R systems will be decided. The results showed that this proposed method is significantly capable of determining optimal system and building design for saving energy.

A study on the efficiency of sloped type Double-skin System for the Curtailment of Heating/Cooling Load (냉난방부하 절감을 위한 경사형 이중외피시스템의 성능연구)

  • An, Hyung-Jun;Kim, Young-Tag;Choi, Chang-Ho;Lee, Hyn-Woo
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.4
    • /
    • pp.77-87
    • /
    • 2004
  • BIPV or double skin applied to the surface of the building, power and thermal load cannot both be increased. In the case of BIPV, because it is applied to the facade, incident solar energy decreases and efficiency drops off. The system in this paper complements these disadvantages and aims to decrease the heating & cooling load by transforming solar energy to electronic and thermal energy. The research in this paper is about the applicability of the clear PV attached double-skin system. And the PV electronic generation and the factors that affect the heating & cooling load such as the daily radiation, sun shading ratio, heating & cooling load, daylight luminance and glare distributions in the building are simulated.

A Study on the Analysis of Heating and Cooling Load through Applying Window Film Insulation (열 차단 필름의 적용에 따른 냉난방 부하 분석에 관한 연구)

  • Kim, Seok-Hyun;Cho, Young-Hum
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.6
    • /
    • pp.47-53
    • /
    • 2013
  • In order to reduce the energy consumption of the building, much effort is being made. The problems are that excessive solar radiation in summer and the heat loss in winter by the increase of window area. To prevent this problems, government limited the window area ratio or the performance of windows in new buildings. In order to reduce energy consumption of the existing buildings, the window film insulation is spotlight because the window film insulation was simple to installation. This study confirmed the performance of the window film insulation and affect to heating & cooling load of buildings. The impact of the window film insulation coating was confirmed by experiment. And this study confirmed the annual heating & cooling load by simulation. As a results, the surface temperature of coated window was higher than the surface temperature of existing window. The window film insulation was increased surface temperature of window. And this study confirmed that the increased surface temperature was slightly affected the room air temperature through experiment of the insulation box. The results of the heating and cooling load by simulation, this study confirmed that the case of coated window film insulation decreased cooling load in summer and increased heating load in winter. Also the annual total heating & cooling load was increased a little in the case of coated the window film insulation.

Cooling and Heating Load Analysis According to Building Type of Apartment House (공동주택의 주동 유형별 냉난방부하 분석)

  • Yoon, Sung-Meen;Lee, Kyung-Hee;Ahn, Young-Chull;Kim, Yong-Tae
    • Journal of Power System Engineering
    • /
    • v.18 no.1
    • /
    • pp.45-50
    • /
    • 2014
  • This study focuses on the analysis of the cooling and heating load in accordance with apartment houses arrangement type using Ecotect Analysis. Korea have to reduce energy consumption part of building except in industry and transport because the rate of dependence on imports amounts to 94%, Apartment houses built in various forms in order to reduce energy are modelled in each window area ratio, shape, orientation, and climate through simulation. Through this study, we can analyze the cooling and heating load by form, window area ratio, orientation, and climate change and know the optimal elements by the form. In particular, although there have been done research on the window area ratio and the arrangement form, the research of the regional climate characteristics and the direction are hardly carried out. To supplement those problem, adding to seven direction and climatic element of southern region is characteristic(L Type, Y Type, - Type) of this study. The form of apartment houses built 10 years ago is modelled for simulation.

Effect of cooling rate on the post-fire behavior of CFST column

  • Afaghi-Darabi, Alireza;Abdollahzadeh, Gholamreza
    • Computers and Concrete
    • /
    • v.23 no.4
    • /
    • pp.281-294
    • /
    • 2019
  • The post-fire behavior of structural elements and the cooling process has always been one of the main concerns of the structural engineers. The structures can be cooled at different rates, where they affect the structure's behavior. In the present study, a numerical model has been developed using the Abaqus program to investigate the effect of cooling rate on the post-fire behavior of the CFST column. To verify the model, results of an experimental study performed on CFST columns within a full heating and cooling cycle have been used. In this model, coMParison of the residual strength has been employed in order to examine the behavior of CFST column under different cooling rates. Furthermore, a parametric study was carried out on the strength of steel and concrete, the height of the specimens, the axial load ratio and the cross-sectional shape of the specimen through the proposed model. It was observed that the cooling rate affects the behavior of the column after the fire, and thus the higher the specimen's temperature is, the more effect it has on the behavior. It was also noticed that water cooling had slightly more residual strength than natural cooling. Furthermore, it was recognized from the parametric study, that by increasing the strength of steel and concrete and the load ratio, as well as modifying the cross-sectional shape from circular to square, residual strength of column at the cooling phase was less than that of the heating phase. In addition, with reducing column height, no change was witnessed in the column behavior after the cooling phase.

Window-to-Wall-Ratio for Energy Reduction in Early Design Stage of Residential Building

  • Lee, Myung Sik
    • Architectural research
    • /
    • v.19 no.4
    • /
    • pp.89-94
    • /
    • 2017
  • In Korea, it is necessary to improve the performance of buildings with respect to the energy efficiency while improving the quality of occupants' lives through a sustainable built environment. During the design and development process, building projects must have a comprehensive, integrated perspective that seeks to reduce heating, cooling and lighting loads through climate-responsive designs. The aim of this study is to assess the optimal window-to-wall ratio of multi-rise residential units in the early design phase in Korea. The study analyzed the variation of annual heating and cooling energy load in two apartment prototype units located in Seoul city using different WWRs. The analysis was conducted using Autodesk Ecotect Analysis 2011 tool. The study found for total annual building load reductions WWR on the south and north face should be studied independently based on the room function. It also found reducing the WWR for bedrooms and windows on the northern façade resulted in reduced total annual building load.

The Possibility on Utilization of Underground Pit for Reduction of Cooling and Heating Load (냉방과 난방 부하 감소를 위한 지하피트의 이용 가능성)

  • Cho Sung-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.2
    • /
    • pp.144-150
    • /
    • 2006
  • The purpose of this study is to predict outlet temperature and humidity through underground pit for the reduction of cooling load and heating load. Commonly, the underground temperature is lower than outdoor in summer but the reverse happens in winter. When the outdoor average air temperature is $25.7^{\circ}C$ during cooling periods, the average outlet air temperature through underground pit is $23.6^{\circ}C$ with 3 m-depth and 60m-length and is $22.2^{\circ}C$ with 3 m-depth and 150 m-length. When the outdoor average air temperature is $4.9^{\circ}C$ during heating periods, the average outlet air temperature through underground pit is $7.7^{\circ}C$ with 3m-depth and 60 m-length and is $10.8^{\circ}C$ with 3 m-depth and 150 m-length. The outlet air temperature is affected by more length than depth of underground pit. The diffusion ratio of outdoor humidity is $-7.7\times10^{-8}kg/s$ in cooling periods and $9.29\times10^{-7}kg/s$ in heating periods.

Development and comparative analysis of slat angle control algorithm of venetian blind according to window-to-wall ratio and zone orientation (창면적비 및 향변화에 따른 슬랫형 블라인드의 최적각도 제어 알고리즘 산출 및 비교분석)

  • Kwon, Hyuk-Ju;Lee, Keum-Ho;Lee, Kwang Ho
    • KIEAE Journal
    • /
    • v.17 no.4
    • /
    • pp.75-81
    • /
    • 2017
  • Purpose: Most contemporary office buildings supply external views, a sense of openness and a sense of time to their occupants by adopting the curtain walls, which are equipped with an outer cover having large window area. As a result, the amount of radiation increases, adversely affecting cooling load during the summer in office buildings. Although solar radiation decreases heating load and reduces energy costs during the winter period, due to the characteristics of offices where occupants work largely during daytime, the cooling load is important compared to the heating. Therefore, diverse measures to resolve those trade-offs and annual energy cost have been investigated. Method: In this study, the annual thermal load was comparatively analyzed according to the slat angle of the venetian blind along with lighting control technique. Result: After selecting effective conditions, in order to resolve such issues, this study established automated control strategies of slat angle depending on the window-to-wall ratio and zone orientation, so that the findings of this study can be effectively generalized to other circumstances.