• 제목/요약/키워드: Cooling-air cooler

검색결과 121건 처리시간 0.024초

이산화탄소 에어컨 시스템을 이용한 연료전지 자동차의 스택 냉각성능에 대한 실험적 연구 (Experimental Studies on the Stack Cooling Performance Using a $CO_2$ Air Conditioning System in Fuel Cell Vehicles)

  • 김성철;김민수;원종필
    • 한국자동차공학회논문집
    • /
    • 제16권3호
    • /
    • pp.87-93
    • /
    • 2008
  • The $CO_2$ air conditioning system installed in fuel cell vehicles could be used either for stack cooling or for cabin cooling, and thus was used for the stack cooling when additional stack heat release was required over a fixed radiator capacity for high power generation. This study investigated the performance of the stack cooling system using $CO_2$ air conditioner at various operating conditions. Also, the heat releasing effectiveness and mutual interference were analyzed for the stack cooling system using an air conditioner and compared with the conventional radiator cooling system with/without cabin cooling. The heat release of the stack cooling system with the aid of $CO_2$ air conditioner increased up to 36% more than that of the conventional radiator cooling system with cabin cooling. Furthermore, the heat release of the stack cooling system using $CO_2$ air conditioner increased more by 7% than that of the conventional radiator cooling system without cabin cooling.

곡물냉각기의 개발 (Development of a New Commercial Grain Cooler)

  • 김동철;김의웅;금동혁;한종규
    • 한국식품저장유통학회지
    • /
    • 제11권2호
    • /
    • pp.250-256
    • /
    • 2004
  • 국내의 기상조건 및 벼의 수확후 처리여건에 적합한 곡물냉각기를 개발하고, 냉각능력, 재열능력, 가열능력, 소요전력 및 성능계수 등의 성능을 측정하여 설계조건에 적합한지를 분석하였다. 그 결과를 요약하면 다음과 같다. 압축기 무부하전자변과, 재열기 및 증발기에 고온고압의 냉매가스를 공급하여 냉각능력을 0∼100%까지 제어할 수 있고, 온도 5$^{\circ}C$이상, 상대습도 54∼95%의 정온정습 공기를 발생할 수 있는 1일 최대 벼 200톤을 냉각할 수 있는 곡물냉각기를 개발하였다. 이 곡물냉각기의 최대냉각능력은 35,284㎉/hr, 송풍량 및 정압은 각각 120㎥/min, 279mmAq이었으며, 재열기를 통한 냉각공기의 최대 온도상승 및 상대습도의 저하범위는 각각 7.6∼8.6$^{\circ}C$, 34.5∼41.0%이었으며, 최대가열능력은 5.6$^{\circ}C$이었다. 또한, 최대 소요동력은 22.8㎾이었으나, 압축기의 무부하 전자변이 작동될 때는 총소요동력의 33.3%, 압축기 소요축동력의 44.7%가 절약되는 것으로 나타났으며, 제어조건에 따라 전체소요동력의 26.7~33.3%정도가 절약되는 것으로 나타났으며, 냉동시스템의 성능계수는 과냉각으로 인해 표준냉동사이클하에서의 4.0보다 높은 4.71이었으며, 전성능계수는 1.8로 나타났다.

자동차 엔진냉각계의 해석 프로그램의 개발 (Development of Simulation Program of Automotive Engine Cooling System)

  • 배석정;이정희;최영기
    • 설비공학논문집
    • /
    • 제15권11호
    • /
    • pp.943-956
    • /
    • 2003
  • A numerical program has been developed for the simulation of automotive engine cooling system. The program determines the mass flow rate of engine coolant circulating the engine cooling system and radiator cooling air when the engine speed is adopted by appropriate empirical correlation. The program used the method of thermal balance at individual element through the model for radiator component in radiator analysis. This study has developed the program that predicts the coolant mass flow rate, inlet and outlet temperatures of each component in the engine cooling system (engine, transmission, radiator and oil cooler) in its state of thermal equilibrium. This study also combined the individual programs and united into the total performance analysis program of the engine cooling system operating at a constant vehicle speed. An air conditioner system is also included in this engine cooling system so that the condenser of the air conditioner faces the radiator. The effect of air conditioner to the cooling performance, e.g., radiator inlet temperature, of the radiator and engine system was examined. This study could make standards of design of radiator capacity using heat rejection with respect to the mass flow rate of cooling air. This study is intended to predict the performance of each component at design step or to simulate the system when specification of the component is modified, and to analyze the performance of the total vehicle engine cooling system.

초임계 $CO_2$의 헬리컬 코일관 내 열선단과 압력강하 특성 (Heat Transfer and Pressure Drop Characteristics of Supercritical $CO_2$ in a Helically Coiled Tube)

  • 유태근;김대희;손창효;오후규
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.353-358
    • /
    • 2005
  • The heat transfer and pressure drop of supercritical $CO_2$ cooled in a helically coiled tube was investigated experimentally. The experiments were conducted without oil in the refrigerant loop. The experimental apparatus of the refrigerant loop consist of receiver, a variable speed pump, a mass flowmeter, a pre-heater, a gas cooler(test section) and an isothermal tank. The test section is a helically coiled tube in tube counter flow heat exchanger with $CO_2$ flowed inside the inner tube and coolant( water) flowed along the outside annular passage, It was made of it copper tube with the inner diameter of 4.55[mm]. the outer diameter of 6.35 [mm] and length of 10000 [mm]. The refrigerant mass fluxes were $200^{\sim}600$ [kg/m2s] and the inlet pressure of gas cooler varied from 7.5 [MPa] to 10.0 [MPa]. The main results are summarized as follows : The heat transfer coefficient of supercritical $CO_2$ increases, as the cooling pressure of gas cooler decreases. And the heat transfer coefficient increases with the increase of the refrigerant mass flux. The pressure drop decreases in increase of the gas cooler pressure and increases with increase the refrigerant mass flux.

  • PDF

실험을 통한 이동형 냉방기의 실내 온도분포 특성의 검토 (Study on Indoor Thermal Environment Controlled by Portable Cooler)

  • 최동균;송두삼;김중호
    • 설비공학논문집
    • /
    • 제28권2호
    • /
    • pp.49-54
    • /
    • 2016
  • The purpose of this study is to analyze the indoor temperature distribution of a room controlled by a personal and portable cooler. As an energy saving strategy, the personal air-conditioning or task conditioning system was developed and installed in office buildings in the 90 s. Many research results regarding the personal air-conditioning (PAC) system were focused on thermal comfort, localized ventilation efficiency and energy savings. However, the conventional PACs were only developed for application in office buildings. In this study, as a type of PAC, a portable cooler was analyzed in terms of indoor temperature distribution changes with the passage of time. The measurement was performed in a bedroom in an apartment house. The results showed that indoor temperature was controlled at about $24^{\circ}C$ around the human body. However, the ambient zone up to 1.5 m away from the the human body stayed at about $27.5^{\circ}C$.

사계절 외기 전용 공조기에 대한 실험적 연구 (An Experimental Study on Four-season Dedicated Outdoor Air Handling Unit)

  • 박승태;김종천;홍영주;김영일
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.577-582
    • /
    • 2008
  • The present study has been conducted to study the performance of Dedicated outdoor air handling unit. Dedicated outdoor air handling unit consists of pre-cooler, dehumidification and after cooler. By combining dedicated outdoor air-conditioning and heat pump, a new four-season dedicated outdoor air handling unit has been developed. Amount of energy saved and condition when this new system is superior to conventional vapor-compression cooling system has been presented.

  • PDF

Cooling-Heating System Using Thermoelectric Module and Parallel Flow Type Pulsating Heat Pipe

  • Kim Jeong-Hoon;Im Yong-Bin;Lee Seong-Ho;Lee Euk-Soo;Kim Jong-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제13권4호
    • /
    • pp.217-224
    • /
    • 2005
  • The purpose of this study was to develop a cooler/heater using a thermoelectric module combined with a parallel flow type pulsating heat pipe with R-142b as a working fluid. The experiment was performed for 16 thermoelectric modules (6A/15V, size: $40\times40\times4mm$), varying design parameters of the heat pipe (inclination angle, working fluid charging ratio, etc.). Experimental results indicate that the optimum charging ratio and the inclination angle of the parallel flow type pulsating heat pipe were $30\%$ by volume and $30^{\circ}$, respectively. The maximum cooler/heater capacity were 479 W (COP: 0.47) and 630 W (COP: 0.9), respectively.

액화천연가스의 냉열을 이용한 가스터빈의 성능향상 (Improvement of Gas Turbine Performance Using LNG Cold Energy)

  • 김동섭;노승탁;이우일;최만수;고상근
    • 대한기계학회논문집B
    • /
    • 제23권5호
    • /
    • pp.653-660
    • /
    • 1999
  • This work describes analysis on the effect of inlet air cooling by the cold energy of liquefied natural gas(LNG) on the performance of gas turbines. Gas turbine off-design analysis program to simulate the influence of compressor inlet temperature variation is prepared and an inlet air cooler is modeled. It is shown that the degree of power augmentation is much affected by the humidity of inlet air. If the humidity is low enough, that is the water content of the air does not condense, the temperature drop amounts to $18^{\circ}C$, which corresponds to more than 12% power increase, in case of a $1350^{\circ}C$ class gas turbine with methane as the fuel. Even with 60% humidity, about 8% power increase is possible. It is found that even though the fuel contains as much as 20% ethane in addition to methane, the power improvement does not change considerably. It is observed that if the humidity is not too high, the current system is feasible oven with conceivable air pressure loss at the inlet air cooler.

원심압축기 소음측정과 계산에 관한 연구 (An Experimental and Numerical Study on Centrifugal Compressor Noise)

  • 선효성;엄승신;신형기;이수갑
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.119-124
    • /
    • 2000
  • The 3-stage centrifugal compressor is used in order to measure the noise spectra of compressor, and analyze the results. Two cases are investigated for compressor noise components. Case I includes total system such as compressor, inter-cooler, motor, and Case II excludes cooling system. BPF tonal noise is important in compressor, and cooling system including inter-cooler contributes to broadband noise. Also, motor, gear box, and motor cooling fan are the second contributions to total compressor noise. Centrifugal compressor flow-field is calculated using two-dimensional grid and Navier-Stokes equations. Static pressure increases, and total pressure decreases, as air passes through the compressor components.

  • PDF