컴퓨터 내장형 냉각시스템 개발 (Development for Inserted Type Coling System in Computer)

  • 이현용;임선종
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2009년도 추계학술대회
    • /
    • pp.399-404
    • /
    • 2009
  • The research for computer cooling system has been researched briskly at home and abroad. Most of computer cooling systems are the air cooling method using cooling fan. The air cooling system are most widely used for low cost and easy installation but have limits in cooling. The water cooling system are good for cooling efficiency but bad for installation. This paper presents the developing for cooling system to be inserted in computer using thermoelectric module.

  • PDF

태양열 냉방 및 급탕 시스템의 제어 조건에 따른 열성능 (Thermal Performance of Solar Cooling & Hot-water System According to Control Condition)

  • 이호;주홍진;김상진;곽희열
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.214-219
    • /
    • 2008
  • This study is describes thermal performance of solar cooling and hot water for demonstration system with ETSC(Evacuated tubular solar collector) installed at Seo-gu culture center of Kwanju. Control condition for solar cooling and hot water system is changed by connection of auxiliary heater. Demonstration system was connected to central air conditioning system. Demonstration system was operated by two types. First type(A) was operated to cooling and hot water supply in that order. Second type(B) was operated to hot water supply and cooling in that order. As a result. it was indicated that the total solar energy consumption of (A) was 799 MJ and the solar energy consumption rate for the cooling and hot water supply was 70% and 30% respectively. Total solar energy consumption of (b) was 898 MJ and the solar energy consumption rate for the cooling and hot water supply was 31% and 69% respectively.

  • PDF

사례 분석을 통한 해양심층수의 지역냉방시스템 적용 방안 (Application of District Cooling System for Deep Ocean Water by Case Study)

  • 진수휘;박진영;김삼열;김현주
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 춘계학술발표대회 논문집
    • /
    • pp.179-184
    • /
    • 2011
  • The development of new energy has attracted consideration attention due to the high oil price and environmental problems. In advanced country, they have tried to carry out a long range plan for energy. We need to develop new energy for Low Carbon Green Growth in Korea. The building is 30% among ratio of energy consumption in Korea. And in the past, heating energy was high ratio for energy using at home. But recently, the demand for cooling energy keeps growing due to rising average temperature on the earth and improvement of life quality. In this situation, the energy of lake water and ocean water has studied to utilize in advanced country because of low temperature at underwater. But the study for deep water is still a lot left to do. In this study, we analyzed district cooling system and the present condition. Analyzing the deep lake water cooling system in Toronto, we found an application of district cooling system using deep ocean water. Deep lake water uses heat source for district cooling and water source for city in Toronto. So reducing the initial cost, this city had economic effect. When DLWC was applied at existing building, the heat exchanger was installed instead of cooling tower and refrigerator. And the heat exchanger used to connect main pipe with cool water on city. System using deep ocean water can be applied as a similar way to supply cool water from lake to building.

  • PDF

냉각재킷의 설계인자에 따른 열전냉각장치의 성능에 관한 연구 (A Study on the Performance of Thermoelectric Cooling System for Design Parameters of the Cooling Jacket)

  • 박상희;이정은;김경진;김동주
    • 설비공학논문집
    • /
    • 제21권3호
    • /
    • pp.149-156
    • /
    • 2009
  • A small-scale thermoelectric cooling system was built in an effort to enhance the performance of the refrigeration system by utilizing the water-cooled jacket which was attached to the hot side of the thermoelectric module. Considered design parameters for the water-cooled jacket were the geometry of the flow passage inside the jacket and the flow rate of cooling water. The higher flow rate of cooling water in the jacket resulted in a better performance of the refrigeration system. The increase in the number of channels for water flow passage inside the cooling jacket also showed significant improvement on the performance of the thermoelectric cooling system such as the cooling capacity and the COP of the refrigeration system.

부식 및 스케일 억제제에 의한 냉각수 수질향상 (Improvement of Cooling Water Quality by Corrosion and Scale Inhibitor)

  • 조관형;우달식;황병기
    • 한국환경과학회지
    • /
    • 제18권2호
    • /
    • pp.187-195
    • /
    • 2009
  • This study was investigated to control the corrosion and scale at the cooling water system in steel works. Laboratory and field tests were performed for the indirect cooling water system of plate mill. Throughout the experiment, various factors such as leakage of pipes, heating rate and capacity, and the reaction between existing and substitute inhibitors were carefully monitored. The results showed that the harmful effect of high temperature could be minimized, and satisfactory corrosion/scale controls were effectively achieved using inhibitor, even at the increased temperature of $80^{\circ}C$. The batch and field tests in the gas scrubbing cooling water system of blast furnace and cooling water system of corex plant indicated that the new inhibitor was more effective for the prevention of corrosion and scale than the existing one.

스팀 에젝터에 의한 강제 증발 방식의 냉각 특성에 관한 연구 (Study on Cooling Charcteristics of Forced Evaporation by using Steam Ejector)

  • 손호재;이윤환;김영근;정효민
    • 동력기계공학회지
    • /
    • 제10권2호
    • /
    • pp.41-46
    • /
    • 2006
  • This study shows a water cooling system by using a steam ejector and jet condenser to drop the temperature of the water by about $5^{\circ}C\;from\;25^{\circ}C$ or higher. In this research, to replace the present water cooling system, we focused on a water cooling system by latent heat of evaporation, thus this system needs a vacuum pressure to evaporate the water in enclosed tank. The water cooling effects are depended on the vacuum pressure in the enclosed tank, and the cooling water is generated by latent head of evaporation. As the experimental results, the absolute vacuum pressure obtained was about $5{\sim}8$ mmHg using a steam driven ejector with jet condenser.

  • PDF

HVDC 시스템의 수냉식 냉각 시스템 (Water-Cooling System of HVDC System)

  • 김찬기
    • 전력전자학회논문지
    • /
    • 제4권3호
    • /
    • pp.257-267
    • /
    • 1999
  • 본 논문은 대용량 컨버터의 수냉식 방열 시스템에 관한 내용을 담고 있다. 본 논문은 수냉식 방열 시스템의 이론적 근거와 모델링을 제시하고 전력용 반도체(싸이리스터)의 열량 계산을 수학적인 모델링에 근거하여 제시하였으며 실제로 우리나라에 설치되어 있는 제주-해남 HVDC 시스템에 적용하여 타당성을 검증하였다.

  • PDF

대용량 전기추진시스템 설계를 위한 제어알고리즘 개발 (Control Algorithm Development for Design of Cooling System in High-power Propulsion Motor)

  • 오진석;정성영;공영경;빈재구;김한호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제34권1호
    • /
    • pp.195-201
    • /
    • 2010
  • 본 논문에서는 에너지 절감 기능을 포함한 대용량 전기추진모터용 냉각 시스템을 제안한다. 기존 시스템에서 청수, 해수 펌프 속도는 일정하며, 냉각수의 과냉각을 방지하기 위해 3-way valve으로 열교환기에 들어가는 유량을 제어하였다. 그리하여 외부 해수 온도의 변화와 관계없이 펌프의 전력 사용량은 일정하였다. 제안된 시스템은 외부 해수 온도에 따라 청수, 해수 펌프의 속도를 인버터로 제어하여 3-Way valve를 최소한으로 동작하도록 함으로써 에너지 손실을 방지한다. 본 연구에서는 제안한 시스템의 효율성을 확인하기 위해 시뮬레이션을 통하여 검증하였다.

밀폐용기내의 물의 저압 증발 최적조건에 관한 실험적 연구 (An Experimental Study on the Water Evaporation Conditions of the Enclosed Tank)

  • 김세현;신유식;이윤환;정한식;정효민
    • 동력기계공학회지
    • /
    • 제8권1호
    • /
    • pp.41-47
    • /
    • 2004
  • Cooling towers are widely used not only for cooling products and equipment in manufacturing process but HVAC(Heating, Ventilation and Air Conditioning) system. As a cooling tower is the terminal apparatus which discharges heat from industrial process, the efficiency of heat exchange in the cooling tower greatly affects to the overall performance of a thermal system. In this paper, we constituted a new water cooling system by using a Latent heat of evaporation in an enclosed tank, and this system is consisted of an enclosed vacuum tank and water driven ejector system. Several experimental cases were carried out for improvement methods of high vacuum pressure and water cooling characteristics. The ejector performance was tested in case of water temperature variations that flows into the ejector. Based on the vacuum pressure by water driven ejector, the water cooling characteristics were investigated for the vaporized air condensing effects.

  • PDF

HEV용 인버터의 방열을 위한 수냉식 배관구조 (Water Cooling Pipe Structure for Heat-Dissipation of HEV Inverter System)

  • 김경만;우병국;이용화;강찬호;전태원;조관열
    • 전력전자학회논문지
    • /
    • 제15권1호
    • /
    • pp.27-34
    • /
    • 2010
  • 하이브리드 전기자동차(HEV)용 인버터의 스위칭 소자에서 발생하는 열을 효율적으로 냉각시키기 위한 수냉식구조를 제안한다. 기존의 볼트형 냉각구조는 강한 수압에서 누수현상이 발생할 수 있으므로 본 논문에서는 이를 방지하기 위해 방열판 내에 파이프 형태의 구조를 적용하였다. 발열원을 기준으로 수로의 이격거리 변화와 여러 형태의 수로에 대해 방열현상을 시뮬레이션으로 해석하고, 방열효과가 우수한 2가지 배관구조 모델을 기준으로 방열효과를 비교 분석하였다. 시뮬레이션 결과를 토대로 2가지 배관구조를 적용한 HEV용 30kW급 인버터를 제작하여 방열효과를 검증하였다.