Browse > Article
http://dx.doi.org/10.6113/TKPE.2010.15.1.27

Water Cooling Pipe Structure for Heat-Dissipation of HEV Inverter System  

Kim, Gyoung-Man ((주)이지트로닉스)
Woo, Byung-Guk ((주)이지트로닉스)
Lee, Yong-Hwa ((주)동아일렉콤)
Kang, Chan-Ho ((주)이지트로닉스)
Chun, Tae-Won (울산대 전기전자정보시스템공학부)
Cho, Kwan-Yuhl (충주대 정보제어공학과)
Publication Information
The Transactions of the Korean Institute of Power Electronics / v.15, no.1, 2010 , pp. 27-34 More about this Journal
Abstract
To dissipate the heat generated from the switching devices in the inverter system of HEV, the water cooling structure is proposed. The bolt type cooling structure has a problem such as water leakage for high pressure of water, therefore the proposed cooling structure applied pipe structure in the heat sink. The heat dissipation characteristics for various structures of water channel and distance between heat source and water channel was analyzed through the simulation. heat dissipation effect for two types of water cooling structures was investigated. Based on the simulation results, two types of water cooling system for 30kW inverter system of HEV were manufactured and the heat dissipation effect was verified.
Keywords
Heat dissipation; Water cooling; Pipe structure; Inverter; HEV; ICE-PAK program;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 이지명, 이재용, 박래관, 장서건, 최경수, "하이브리드 전기자동차 구동용 전력변환장치", 전력전자학회 논문지, 제13권, 제6호, pp. 420-429, 2008. 12.
2 N. Mohan, T. M. Undeland, and W. P. Robbins, Power Electronics : Converters, Applications, and Design, John Wiley & Sons, pp. 3-6, 1989.
3 김유한, 이현동, 유기호, "연료전지차용 100 kW 전기구동시스템 냉각설계기술 개발", 전력전자학회 2008년도 하계학술대회 논문집, pp. 428-430, 2008. 6.
4 U. Drofenik, G. L. Johan, and W. Kolarb, "Pump Characteristic Based Optimization of Direct Water Cooling System for 110-kW/500-kHz Vienna Rectifier", IEEE Trans. on Power Electronics, Vol. 20, No. 3, pp. 704-714, 2005, May.   DOI   ScienceOn