• 제목/요약/키워드: Cooling time

검색결과 1,635건 처리시간 0.027초

Towards a reduced order model of battery systems: Approximation of the cooling plate

  • Szardenings, Anna;Hoefer, Nathalie;Fassbender, Heike
    • Coupled systems mechanics
    • /
    • 제11권1호
    • /
    • pp.43-54
    • /
    • 2022
  • In order to analyse the thermal performance of battery systems in electric vehicles complex simulation models with high computational cost are necessary. Using reduced order methods, real-time applicable model can be developed and used for on-board monitoring. In this work a data driven model of the cooling plate as part of the battery system is built and derived from a computational fluid dynamics (CFD) model. The aim of this paper is to create a meta model of the cooling plate that estimates the temperature at the boundary for different heat flow rates, mass flows and inlet temperatures of the cooling fluid. In order to do so, the cooling plate is simulated in a CFD software (ANSYS Fluent ®). A data driven model is built using the design of experiment (DOE) and various approximation methods in Optimus ®. The model can later be combined with a reduced model of the thermal battery system. The assumption and simplification introduced in this paper enable an accurate representation of the cooling plate with a real-time applicable model.

급기환기량에 따른 공조기의 설정온도 도달특성 분석 연구 (A Study on the Reaching Time of Setting Temperature with Ventilation Air)

  • 강태욱
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권1호
    • /
    • pp.50-57
    • /
    • 2006
  • This study describes to analyze the cooling load characteristics for a room air conditioner as a function of supply ventilation air when an air conditioner is running An experimental apparatus consists of a test room, a room air conditioner, a humidifier, an electrical heater a supply fan and a controller The reaching time to the inside setting temperature of the room air conditioner with is evaluated theoretically and experimentally in a conditioned space cooling loads such as supply ventilation air, lighting, occupancy and infiltration. In the conditions of cooling loads for the supply ventilation air of 9.5 L/s(0.98 ACH). lights. one Person, and infiltration, the reaching time to the inside setting temperature ($27\;^{\circ}C$ dry-bulb) increases up to $35\%$ more than for no supply ventilation air condition. Theoretical modelling of the reaching time shows good agreement with experimental results.

Al-7wt%Si-0.3wt%Mg 합금의 응고 및 미세조직에 미치는 Sr 첨가와 금형예열온도의 영향 (The Effect of Sr Addition and Mold Preheating Temperature on the Solidification and Microstructure of Al-7wt%Si-0.3wt%Mg Alloy)

  • 권일수;김경민;윤의박
    • 한국주조공학회지
    • /
    • 제17권6호
    • /
    • pp.608-614
    • /
    • 1997
  • The effect of mold preheating temperature on the microstructure such as grain size, eutectic silicon morphology was investigated for the Al-7wt%Si-0.3wt%Mg alloy. Microstructural variations have been characterized as a function of Sr addition and cooling rate during solidification. Microstructures were correlated with cooling rate, local solidification time and eutectic nucleation temperature, etc. In this study, Sr addition caused increase of local solidification time, undercooling and reduction of eutectic plateau temperature. In logarithmic scale, local solidification time was in inverse proportion to cooling rate. Eutectic nucleation temperature was in inverse proportion to cooling rate of logarithmic scale. Increasing the cooling rate refined dendrite arm spacing and eutectic silicon. Dendrite arm spacing was logarithmically in inverse proportion to cooling rate. Without modifier addition, eutectic silicon was modified at cooling rate of $7^{\circ}C/s$ or higher.

  • PDF

The Effect of Exposure in Elevated Temperatures on Bending Properties of Wood

  • Park, Joo-Saeng;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • 제27권4호
    • /
    • pp.20-29
    • /
    • 1999
  • Temperature has important effect on mechanical properties of wood. These effect needs to be understood and taken into account in the structural use of wood. Furthermore, the effect of cooling after exposing to high temperature must be explained. In this study, the effect of temperature, exposure time, specific gravity, and cooling on bending properties were investigated. The boundary temperatures at which bending MOE and MOR reduced rapidly were approximately $200^{\circ}C$ and $150^{\circ}C$, respectively. This boundary temperature was nearly constant with independence of species(specific gravity), exposure time, and cooling. Above the boundary temperature, the effect of exposure time was increased with temperature and the reduction of bending MOE and MOR for Japanese Larch with relatively higher specific gravity was smaller than that of Hem-fir. The recovery of bending MOE and MOR after cooling was also more significant above the boundary temperature than below. The degree of cooling effect was larger for MOR than MOE. Consequently, bending properties of wood in elevated temperatures should be considered in terms of the boundary temperature, $200^{\circ}C$ for bending MOE, $150^{\circ}C$ for MOR, and these boundary temperatures must be considered an important factor. Furthermore, to evaluate the safety of structure, the recovery after cooling should be considered.

  • PDF

축냉 시스템을 적용한 쇼케이스 운전에 대한 실험적 연구 (Experimental Study of Showcase Using Cold Storage System)

  • 이은지;이동원;김용찬
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1111-1116
    • /
    • 2008
  • The purpose of this study is to maintain high efficiency and reasonable use of cold-heat storage systems operated the showcase. An experimental study is carried out to manufacture the showcase system in a laboratory. Comparing the result at general operation condition with that at the new condition using ice storage system, this study showed the effects of the refrigerant sub-cooling, and with using inverter. At the condition using ice storage system, the ice making process was operated during midnight being not needed the cooling of the showcase through the continuous running of the condenser unit. And then, the refrigerant was sub-cooled using stored cold-heat after being discharged from the air cooling condenser during the day time. The cooling performance was increased owing to the sub-cooling of refrigerant during day time, hence the running time of the compressor was effectively decreased. In other words, this study showed that power consumption during daytime can be transferred to the midnight for making use of the refrigerant sub-cooling.

  • PDF

사출금형 냉각시스템 최적화를 위한 설계변수의 감소 방법 연구 (A study on the reduction of design variables for injection mold cooling system optimization)

  • 최재혁;태준성;이병옥
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.361-364
    • /
    • 2009
  • The cooling system optimization for injection molds was studied with a response surface method in the previous research. It took so much time to find an optimum solution for a large product due to an extensive amount of calculation time for the CAE analysis. In order to use the optimization technique in the actual design process, the calculation time should be much reduced. In this study, we tried to reduce the number of design variables with the concept of the close relationship between the depth and the distance of cooling channels. The optimum ratio of the distance to the depth of cooling channels for a 2-dimensional problem was 2.0 so that the optimum ratio was again sought out for 4 industrial products. The major cooling effect of the injection molds for large products rely on baffle tubes. The optimum ratio of the distance to the depth for baffle tubes was 2.0 for the large products. The result enables us to reduce the number of the design variables by half in the cooling system optimization problem.

  • PDF

적외선 센서용 극저온 용기의 냉각특성에 관한 실험적 연구 (An Experimental Study on the Cooling Characteristics of an Infrared Detector Cryochamber)

  • 강병하;이정훈;김호영
    • 설비공학논문집
    • /
    • 제16권10호
    • /
    • pp.889-894
    • /
    • 2004
  • Infrared (IR) detectors are widely used for many applications, such as temperature measurement, intruder and fire detection, robotics and industrial equipment, thermoelstic stress analysis, medical diagnostics, and chemical analysis. Quantum detectors commonly need to be refrigerated below 80 K, and thus a cooling system should be equipped together with the detector system. The cooling load, which should be removed by the cooling system to maintain the nominal operating temperature of the detector, critically depends on the insulation efficiency of the cryochamber housing the detector. Thermal analysis of cryochamber includes the conduction heat transfer through a cold well, the gases conduction and gas outgassing, as well as radiation heat transfer, The transient cooling characteristics of an infrared detector cryochamber are investigated experimentally in the present study. The transient cooling load increases as the gas pressure is increased. Gas pressure becomes significant as the cooling process proceeds. Cool down time is also increased as the gas pressure is increased. It is also found that natural convection effects on cool down time become significant when the gas pressure is increased.

CNC 공작기계의 위치결정 정밀도 향상에 관한 연구 (An Improvement of Positioning Accuracy for CNC Machine Tools)

  • 전언찬;광전강굉;제정신;남궁척
    • 한국정밀공학회지
    • /
    • 제11권6호
    • /
    • pp.5-11
    • /
    • 1994
  • We have investigated the variation of dwell and warm-up time for effects of positioning accuracy of the CNC machine tools with an laser measuring system. Also, we strdied the effect of improvement of the positioning accuracy by variation of the temperature for hollow ball screw, which mostly used as drive mechanism of CNC machine tools. We dbtained the effectiveness of cooling effect of the new cooling system, compared with the conventional cooling system.

  • PDF

Cu를 함유한 HSLA강의 미세 조직과 인성에 미치는 냉각 속도의 영향 (Effect of cooling rate on the microstructure and impact toughness of Cu-bearing HSLA steels)

  • 박태원;심인옥;김영우;강정윤;박화순
    • Journal of Welding and Joining
    • /
    • 제13권2호
    • /
    • pp.122-131
    • /
    • 1995
  • The effects of cooling rate on the microstructures, precipitation of Cu-cluster, .epsilon.-Cu and impact toughness of high strength low alloy(HSLA) steel were studied using hardness tester, impact tester, DSC(differential scanning calorimetry), AES(auger electron spectroscopy) and TEM(transmission electron microscopy). Not only the Cu-precipitates but also the segregation of Cu, As, Sb, P, S, N, Sn along grain boundary were not observed at the specimens heat treated from 800.deg. C to 300.deg. C with the cooling time of 12-125 sec. The Cu-cluster, .epsilon.-Cu are formed by introducing ageing after cooling and the effect of precipitates on hardening increase after cooling was the same in all cooling rate. The peak hardness was obtained at an ageing of 500.deg. C in all cooling conditions. The impact energy become higher as the cooling time increases. This fact can be explained to be due to the tempering effect applied on the cooling stage since the present alloy has a relatively high Ms temperature and the local high concentration of the retained austenite.

  • PDF

히트파이프를 부착한 구동모터의 냉각성능에 관한 연구 (Investigation of Cooling Performance of the Driving Motor Utilizing Heat Pipe)

  • 이동렬
    • 동력기계공학회지
    • /
    • 제10권4호
    • /
    • pp.11-16
    • /
    • 2006
  • This research is to verify the cooling effect of the acting surface on the rotary motor using heat pipe and conventional cooling fan. In order to show the cooling performance of the rotary motor and heat pipe with the fin-typed heat sink, the surface temperature of the motor and condenser was measured in real time. The experiments were also conducted as for not only cooling device installed with heat pipe only, but with heat pipe and conventional cooling fan simultaneously. The present experiment reveals that the cooling combination of the heat pipe and cooling fan is far superior to the conventional cooling device for the driving motor such as the fin-typed heat sink. When the driving voltage of 20V and 14V were supplied to the driving motor, the cooling performance of the rotary motor with heat pipe was 170% and 500%, respectively better than that without heat pipe on steady state condition.

  • PDF