• 제목/요약/키워드: Cooling period

검색결과 409건 처리시간 0.025초

고체질소를 이용한 이동형 초전도 에너지 저장장치용 냉각 시스템 설계 (Design of a Cooling System for a portable HTS Superconducting Magnetic Energy Storage Using a Solid Nitrogen)

  • 김광록;송정빈;김경준;이종훈;이해근;고득용;김석호;성기철
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제10권3호
    • /
    • pp.27-31
    • /
    • 2008
  • In order to cool the SMES coil to the operating temperature, conduction cooling is generally used. However, it often consumes a large amount of electric power because of it's continuous cryocooler operation. This can also lead to poor thermal stability and serious protection problems of the system. Solid nitrogen (SN2) can counter those disadvantages in the conduction cooling system because it has a large heat capacity. Particularly, a large amount of enthalpy with a minimal weight to the cold body of SN2 makes a compact and portable system by increase a recooling to recooling time period (RRTP) value. A conceptual design of the proto-type SN2 cooling system for a portable HTS superconducting magnetic energy storage (SMES) system will be introduced in this paper.

Condenser cooling system & effluent disposal system for steam-electric power plants: Improved techniques

  • Sankar, D.;Balachandar, M.;Anbuvanan, T.;Rajagopal, S.;Thankarathi, T.;Deepa, N.
    • Membrane and Water Treatment
    • /
    • 제8권4호
    • /
    • pp.355-367
    • /
    • 2017
  • In India, the current operation of condenser cooling system & effluent disposal system in existing power plants aims to reduce drawal of seawater and to achieve Zero Liquid Discharge to meet the demands of statutory requirements, water scarcity and ecological system. Particularly in the Steam-Electric power plants, condenser cooling system adopts Once through cooling (OTC) system which requires more drawal of seawater and effluent disposal system adopts sea outfall system which discharges hot water into sea. This paper presents an overview of closed-loop technology for condenser cooling system and to achieve Zero Liquid Discharge plant in Steam-Electric power plants making it lesser drawal of seawater and complete elimination of hot water discharges into sea. The closed-loop technology for condenser cooling system reduces the drawal of seawater by 92% and Zero Liquid Discharge plant eliminates the hot water discharges into sea by 100%. Further, the proposed modification generates revenue out of selling potable water and ZLD free flowing solids at INR 81,97,20,000 per annum (considering INR 60/Cu.m, 330 days/year and 90% availability) and INR 23,760 per annum (considering INR 100/Ton, 330 days/year and 90% availability) respectively. This proposed modification costs INR 870,00,00,000 with payback period of less than 11 years. The conventional technology can be replaced with this proposed technique in the existing and upcoming power plants.

디퓨져와 노즐을 이용한 열공압형 마이크로 펌프의 열공압 및 유동특성에 관한 수치해석적 연구 (A Numerical Study on the Thermopneumatic and Flow Characteristics of Diffuser-Nozzle Based Thermopneumatic Micropumps)

  • 정진;김창녕
    • 설비공학논문집
    • /
    • 제17권7호
    • /
    • pp.642-648
    • /
    • 2005
  • This study has been conducted to investigate the thermopneumatic and flow characteristics of diffuser/nozzle based thermopneumatic micropumps. In this study, a transient three-dimensional numerical analysis using FSI (Fluid-Structure Interaction) model has been employed to analyze the effects of the interaction between the membrane and two fluids (air and water) in the thermopneumtic micropump. The transient temperature and pressure in the cavity, the transient displacements of the membrane and the net flow rate of the micropump have been closely calculated for the frequency of 1 Hz. It has been found that the difference of the flow rates at the inlet and outlet is larger in the cooling period than in the heating period and that the duty ratio is very important in association with pump performance because the temperature in the cavity ascends drastically in the heating period and descends slowly in the cooling period. This study can be regarded as fundamental understandings for the design and analysis of thermopneumatic micropumps.

Pit를 이용한 건물 급기방식의 효용성 평가에 관한 사례 연구 (A Case Study on Effectiveness Assessment of Supply Air System Using Pit in Building)

  • 민준기
    • 한국지열·수열에너지학회논문집
    • /
    • 제13권2호
    • /
    • pp.16-21
    • /
    • 2017
  • In this study, the flow effect of warming and cooling in the air supply of a pit for air conditioning were evaluated in BS art museum. We simulated the flow temperature for a pit winter and summer seasons using computational fluid dynamics. Consequential, energy saving, energy saving costs and initial payback periods were calculated and the following conclusions were drawn. The warming effect of the winter increased by $18.1^{\circ}C$ and $0.2^{\circ}C/m$ and the cooling effect of the summer decreased by $6.1^{\circ}C$ and dropped to $0.07^{\circ}C/m$. Energy saving appeared to be 19.1 kW in the summer and 54.3 kW in winter. Energy saving costs ranged from 2,567,119 won/year to 5,134,238 won/year and at minimum, initial payback period for initial investment was 3.9 years. As a result, the air supply system using an existing pit without any burden on initial investment costs is believed to contribute to energy saving through warming and cooling of unutilized energy effects.

기상 데이터 산정 기간에 따른 국내의 설계용 외기온도 분석 (Analysis of South Korea Outdoor Design Temperature with respect to Assigned Period of the Weather Data)

  • 남아영;김영일;정광섭
    • 한국지열·수열에너지학회논문집
    • /
    • 제13권2호
    • /
    • pp.1-8
    • /
    • 2017
  • Outdoor design temperature is important for selecting proper capacity of heating and cooling systems of a building to implement indoor thermal comfort and save energy consumption. The purpose of this study is to investigate the change of South Korea outdoor design temperature according to the assigned period. When outdoor design temperature of 8 locations calculated with the latest weather data during 2008~2015 years using ASHRAE Bin method are compared to the standard temperature of Ministry of Land, Infrastructure and Transport which is widely used for designing South Korea air-conditioning system at present, the maximum temperature difference becomes $0.97^{\circ}C$ for cooling, and $1.94^{\circ}C$ for heating. Due to wide outdoor temperature variation, update of outdoor design temperature based on recent weather data is recommended.

히트펌프 성능 평가 동향과 국내 지열원 히트펌프 성능 평가 규격 및 제도 분석 (Analysis on the Performance Evaluation Trends of Heat Pumps and the Test Standards of a Geothermal Heat Pump in Korea)

  • 강신형;최종민
    • 한국지열·수열에너지학회논문집
    • /
    • 제13권4호
    • /
    • pp.31-38
    • /
    • 2017
  • The heating and cooling air conditioning field has been increasing the problems of energy consumption and global warming in the world. A geothermal heat pump has been known as one of the highest efficient heating and cooling system. In this study, the analysis about the test standards of the geothermal heat pump of the Republic of Korea was executed. From the research, the following results were given. It is needed to address the domestic test standard for direct heat exchange geothermal heat pump. Water to air multi geothermal heat pump test standard was only developed in Korea. The test standard to calculate a seasonal energy efficiency ratio for cooling period and heat seasonal performance factor for heating period should be newly developed to estimate actual annual energy consumption and $CO_2$ emission.

도서관의 공간사용 특성에 따른 냉난방설비 리모델링의 경제성 평가 (Energy Efficiency Evaluation of Heating and Cooling Systems as Space Program in Renovated Library)

  • 박강현;차정훈;김수민;박경원
    • 설비공학논문집
    • /
    • 제24권3호
    • /
    • pp.205-211
    • /
    • 2012
  • Unlike the previous approaches, we analyzed for economic efficiency of renewed heating and cooling systems as the characteristics of space. The purpose of this study is to analysis the energy consumption and economical efficiency of absorption chillers and EHP systems in renovated library. It is important that equipment selection should be considering energy cost as well as space program. In recently, many EHP systems were installed in the building for reducing the energy cost and for seeking the convenience of individual control. In contrast, though absorption chillers have the disadvantage of a central control, absorption chillers are appropriate for the conditions of the library that needs simultaneous operation. The results by payback period method, show that selection of heating and cooling systems should be consider for space program and the characteristics of space.

예측 냉방부하를 이용한 빙축열시스템의 최적 운전계획 (Optimal Scheduling of Ice Storage System with Prediction of Cooling Loads)

  • 이경호;최병윤;주용진;이상렬;한승호
    • 설비공학논문집
    • /
    • 제12권11호
    • /
    • pp.982-993
    • /
    • 2000
  • This paper describes an optimal control scheduling of an encapsulated ice storage system with a chiller of nominal chiller 34RT(103,200kcal/hr) and an ice storage tank of 170RT-hrs(514,080 kcal). The optimization technique used in the study is dynamic programing. The objective function is summed cost during a day including charge and discharge periods. Control strategies being used commercially are chiller priority and storage priority control. In chiller priority control, the chiller is allowed to run at full capacity during the day, subject to limitations of the building load, and the ice is only melted when and if the load exceeds the chillers full capacity. In contrast to chiller priority control, the aim in storage priority control is to melt as much as ice as possible during the day time period. The system simulation calculates the operation costs for the three control strategies in the condition of the same cooling load and the same ice storage system. The simulation period is a day, assuming that initially the tank is stored fully and the cooling load is perfectly predicted for the scheduling. Also Final state of the tank is to be charged fully.

  • PDF

애구(艾灸)의 연소(燃燒) 구간별(區間別) 열량비(熱量比)에 대(對)한 연구(硏究) (An Experimental Study on the combustion calorie ratio to moxibustion)

  • 강기원;남상수;이재동;최도영;안병철;박동석;이윤호;최용태
    • Journal of Acupuncture Research
    • /
    • 제15권2호
    • /
    • pp.173-182
    • /
    • 1998
  • In order to evaluate calorie rate of moxa-combustion(direct moxibustion=DM, indirect moxibustion with stainless steel tube=IMS, indirect moxibustion with ginger slice=IMG), calorie rate(%) in the preheating period, heating period, retaining period, and cooling period was calculated respectively to the total combustion calories in all the periods. The result are as follow: 1. Indirect moxibustion with stainless steel tube had the highest rate with the statistical significance than other groups during the preheating period, represented statistical differences between IMS group and IMG group, and also between DM group and IMS group. 2. Indirect moxibustion with ginger slice group showed the highest rate with the statistical significance and followed by DM group and IMG group during the heating period, represented statistical difference among DM, IMS, and IMG group. 3. Direct moxibustion group had the highest rate with the statistical significance than other group during the retaining period, represented statistical difference between DM group and IMG group, and also between DM group and IMS group. 4. Indirect moxibustion with stainless steel tube had the highest rate with the statistical significance than other groups during the cooling period, represented statistical differences between IMS group and IMG group, and also between IMS group and DM group.

  • PDF

분리막을 이용한 주거용 제습공조시스템의 LCC 분석 (LCC Analysis of Residential Dehumidifying Air Conditioning System using Thin Separation Membrane)

  • 정용호;박성룡
    • 설비공학논문집
    • /
    • 제30권1호
    • /
    • pp.10-16
    • /
    • 2018
  • The climate of summer in Korea is quite hot and humid. Many studies have been carried out to reduce the energy required for operating a dehumidifier. The dehumidifier is mainly connected to the cooling system since it operates in the summer. Conventional dehumidification methods often require additional cooling and energy for dehumidification. In this study, a system for increasing the efficiency by applying a membrane was analyzed. Its energy saving effect was analyzed when it was applied to residential buildings. Economic efficiency was also evaluated. As a result of this study, 9.0% energy savings were achieved for residential buildings. The investment recovery period was 28.9 years. Such long investment recovery period was because the initial investment cost was excessive and annual energy saving only appeared in the summer.