• 제목/요약/키워드: Cooling part

검색결과 602건 처리시간 0.037초

Effectiveness analysis of pre-cooling methods on hydrogen liquefaction process

  • Yang, Yejun;Park, Taejin;Kwon, Dohoon;Jin, Lingxue;Jeong, Sangkwon
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제22권3호
    • /
    • pp.20-24
    • /
    • 2020
  • The purpose of this analytic study is to design and examine an efficient hydrogen liquefaction cycle by using a pre-cooler. The liquefaction cycle is primarily comprised of a pre-cooler and a refrigerator. The fed hydrogen gas is cooled down from ambient temperature (300 K) to the pre-cooling coolant temperature (either 77 K or 120 K approximately) through the pre-cooler. There are two pre-cooling methods: a single pre-coolant pre-cooler and a cascade pre-cooler which uses two levels of pre-coolants. After heat exchanging with the pre-cooler, the hydrogen gas is further cooled and finally liquefied through the refrigerator. The working fluids of the potential pre-cooling cycle are selected as liquid nitrogen and liquefied natural gas. A commercial software Aspen HYSYS is utilized to perform the numerical simulation of the proposed liquefaction cycle. Efficiency is compared with respect to the various conditions of the heat exchanging part of the pre-cooler. The analysis results show that the cascade method is more efficient, and the heat exchanging part of the pre-coolers should have specific UA ratios to maximize both spatial and energy efficiencies. This paper presents the quantitative performance of the pre-cooler in the hydrogen liquefaction cycle in detail, which shall be useful for designing an energy-efficient liquefaction system.

가변 금형온도 제어기법을 적용한 사출금형의 냉각성능 고찰 (Investigation of Cooling Performance of Injection Molds Using Pulsed Mold Temperature Control)

  • 손동휘;박근
    • 대한기계학회논문집B
    • /
    • 제37권1호
    • /
    • pp.35-41
    • /
    • 2013
  • 금형온도는 사출성형시 수지의 유동특성이나 성형품의 변형에 영향을 미치는 중요한 변수로서, 고온의 수지 주입과 냉각회로에 주입되는 냉각수의 영향을 받아 사출 사이클이 반복될수록 온도의 상승과 하강이 반복되는 주기적인 변화특성을 가지고 있다. 본 연구에서는 금형 냉각회로에 저온과 고온의 유체를 번갈아 주입하는 가변 금형온도 제어기법을 적용하여 성형전에는 금형온도를 높게 유지하고 성형후에는 낮게 유지함으로써 사출성형시 품질과 생산성을 동시에 높일 수 있는 연구를 수행하였다. 특히 열전달-유동해석을 연계한 다중사이클 사출성형 과도해석을 수행하여 수지와 금형, 냉각수간의 과도적인 온도변화를 수치적으로 고찰하였고, 기존 냉각방법과의 해석결과를 비교하여 제안된 가변 금형온도 제어기법의 가열 및 냉각과정에서의 효율성을 비교하였다.

전력변환장치 캐비넷에서의 내부발열 개선을 위한 열유동 분석 및 유통안전성 향상을 위한 진동특성 분석 (Theoretical Heat Flow Analysis and Vibration Characteristics During Transportation of PCS(Power Conversion System) for Reliability)

  • 주민정;서상욱;오재영;정현모;박종민
    • 한국포장학회지
    • /
    • 제28권2호
    • /
    • pp.143-149
    • /
    • 2022
  • PCS needs to freely switch AC and DC to connect the battery, external AC loads and renewable energy in both directions for energy efficiency. Whenever converting happens, power loss inevitably occurs. Minimization of the power loss to save electricity and convert it for usage is a very critical function in PCS. PCS plays an important role in the ESS(Energy Storage System) but the importance of stabilizing semiconductors on PCB(Printed Circuit Board) should be empathized with a risk of failure such as a fire explosion. In this study, the temperature variation inside PCS was reviewed by cooling fan on top of PCS, and the vibration characteristics of PCS were analyzed during truck transportation for reliability of the product. In most cases, a cooling fan is mounted to control the inner temperature at the upper part of the PCS and components generating the heat placed on the internal aluminum cooling plate to apply the primary cooling and the secondary cooling system with inlet fans for the external air. Results of CFD showed slightly lack of circulating capacity but simulated temperatures were durable for components. The resonance points of PCS were various due to the complexity of components. Although they were less than 40 Hz which mostly occurs breakage, it was analyzed that the vibration displacement in the resonance frequency band was very insufficient. As a result of random-vibration simulation, the lower part was analyzed as the stress-concentrated point but no breakage was shown. The steel sheet could be stable for now, but for long-term domestic transportation, structural coupling may occur due to accumulation of fatigue strength. After the test completed, output voltage of the product had lost so that extra packaging such as bubble wrap should be considered.

75% 수소 BATCH 소둔시에서의 코일 온도변화에 관한 연구 (A study on coil temperature bariation in 75% hydrogen batch annealing furnace)

  • 전언찬;김순경
    • 한국정밀공학회지
    • /
    • 제11권2호
    • /
    • pp.173-181
    • /
    • 1994
  • A Cold spot temperature control system for the batch annealing furnace has been estabilished in order to reduce energy consumption to improve productivity and stabilize the propertics of products. Therefore we confirmed a relation between annealing cycle time and atmospheric gas, variation of coil cold spot temperature with time during heating and actual temperature measurements at mid-width of each coil during heating and actual temperature measurements at mid-width of each coil during soaking. The results of the tempaeature variation effect on the batch annealing are as follows. 1) Heating time is reduced to one half with increasing atmospheric gas flow rate and changing of atmospheric gas component from HNx to Ax gas, and annealing cycle time is reduced to 2.7 times. 2) In case of short time healing, the slowest heating part is the center of B coil, in case of long time heating, the low temperature point moves from the center of coil to inside coil. And the temperature in this part is higher than other parts when cooling. When finished heating, the cold spot is located 1/3 of coil inside in case of HNx atmospheric gas. But center of coil in case of Ax atmospheric gas. 3) The outside of top coil is the highest temperature point when heating, which becomes the lowest temperature point when cooling. So, this point becomes high temperature zone at heating and low temperature zone at cooling, It has relation according to atmospheric gas component and flow rate. 4) Soaking time at batch annealing cycle determination is made a decision by the input coil width, and soaking time for quality homogenization of 1214mm width coil must be 2.5 hours longer than that of 914mm width coil for the same ciol weight. 5) Annealing cycle time with Ax atmospheric gas is extended 1 hour in of slow cooling during 5 hours in order to avoid rapid cooling.

  • PDF

A Study of the Evaporation Heat Transfer in Advanced Reactor Containment

  • Y. M. Kang;Park, G. C.
    • Nuclear Engineering and Technology
    • /
    • 제29권4호
    • /
    • pp.291-298
    • /
    • 1997
  • In advanced nuclear reactors, the passive containment cooling has been suggested to enhance the safety. The passive cooling has two mechanisms, air natural convection and oater cooling with evaporation. To confirm the coolability of PCCS, many works have been performed experimentally and numerically. In this study, the water cooling test was performed to obtain the evaporative heat transfer coefficients in a scaled don segment type PCCS facility which have same configuration with AP600 prototype containment. Air-steam mixture temperature and velocity, relative humidity and well heat flux are measured. The local steam mass flow rates through the vertical plate part of the facility are calculated from the measured data to obtain evaporative heat transfer coefficients. The measured evaporative heat transfer coefficients are compared with an analytical model which use a mass transfer coefficients. From the comparison, the predicted coefficients show good agreement with experimental data however, some discrepancies exist when the effect of wave motion is not considered. Finally, a new correlation on evaporative heat transfer coefficients are developed using the experimental values.

  • PDF

소형버스 냉각성능 향상 연구(I) (Study for the Cooling Performance Improvement of a Mini Bus)

  • 류명석
    • 한국자동차공학회논문집
    • /
    • 제13권2호
    • /
    • pp.10-15
    • /
    • 2005
  • This study was initiated to evaluate the cooling performance of CAC (charged air cooler) and radiator in the engine room of a mini bus. So we had firstly to predict the mass flow rate coming from radiator grille and front bum per opening using computational fluid dynamics (CFD) simulation based on 3D configuration. And simulations were carried out for different cooling module layout and bum per opening hole size on sam e vehicle operating condition. Simulation results show that CAC cooling performance at reverse protecting plate-applying model was much efficient than that of the bum per opening hole size-increasing model in IMTD point of view. Part of the CFD simulation results was com pared to with experimental data. It was confirm ed that the CFD approach using STAR-CD based on pursuing no-com promise solution could provide design engineers with useful design information in the early design stage of vehicle development.

철도차량 냉방 및 난방장치의 환경성능 시험방안 연구 (Study on the environmental performance test of cooling and heating equipments' of passenger cabin)

  • 조영민;이준석;박덕신;권순박;정우성
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.223-228
    • /
    • 2009
  • Cooling and heating equipments of railroad passenger cabin is one of the most important part in keeping the good thermal comfort of the passengers. The bad performance of these equipments usually results in the comfort of the passengers. However, there is no testing method for cooling and heating equipments during manufacturing the passenger car, and calculation method is frequently used. Many railroad operators spend a lot of money for the maintenance. In this study, a new environmental performance test for railroad passenger cabin was suggested. The temperature of the chamber will be changed from $-40^{\circ}C$ to $60^{\circ}C$. The performance test of cooling and heating equipment in controlling the passenger cabin temperature was carried out under various temperature condition. The testing method to investigate the effect of artificial sunlight irradiation on the passenger cabin temperature was also suggested.

  • PDF

Ni/Mo 합금분말(FLC-4608)의 소결경화 공정에서 유한요소법을 이용한 마르텐사이트 분율의 예측 (Prediction of Martensite Fraction in the Sintering Hardening Process of Ni/Mo Alloy Powder (FLC-4608) Using the Finite Element Method)

  • 박효욱;주수현;이언식;권기혁;김형섭
    • 한국분말재료학회지
    • /
    • 제22권1호
    • /
    • pp.10-14
    • /
    • 2015
  • In recent years, industrial demands for superior mechanical properties of powder metallurgy steel components with low cost are rapidly growing. Sinter hardening that combines sintering and heat treatment in continuous one step is cost-effective. The cooling rate during the sinter hardening process dominates material microstructures, which finally determine the mechanical properties of the parts. This research establishes a numerical model of the relation between various cooling rates and microstructures in a sinter hardenable material. The evolution of a martensitic phase in the treated microstructure during end quench tests using various cooling media of water, oil, and air is predicted from the cooling rate, which is influenced by cooling conditions, using the finite element method simulations. The effects of the cooling condition on the microstructure of the sinter hardening material are found. The obtained limiting size of the sinter hardening part is helpful to design complicate shaped components.

전기자동차 배터리 안정성 확보를 위한 냉각장치 열특성 연구 (A Study on the Thermal Characteristics of Cooling System for Securing Battery Stability in Electric Vehicle)

  • ;고광수;박윤철
    • 한국지열·수열에너지학회논문집
    • /
    • 제16권2호
    • /
    • pp.7-12
    • /
    • 2020
  • The battery of an electric vehicle is a key part of the energy supply to operate the vehicles. There are many factors affecting battery life such as charging method, discharge rate, and ambient temperature those are requires systematic monitoring and management. To solve the issues like environmental problems and fuel consumption reduction the battery needs more performance improvement. In this study, it was analyzed the thermal characteristics and securing battery stability for electric vehicle battery cooling system. The simulation test was operated using GT-suite software with several conditions like cooling capacity 1, 2 and 4 kW, cooling flow rate 5, 10, 20 and 30 LPM, and battery initial temperatures 40, 35, and 30℃ at the temperature of ambient 25℃. The results shown that the case of cooling flow rate at 20 LPM was most efficient among all above conditions.

케로신을 연료로 하는 10톤급 액체로켓엔진의 막 냉각에 관한 해석적 연구 (Numerical analysis on curtain cooling in Liquid Rocket Engine of 10tf-thrust Level using Kerosene as a Fuel)

  • 남궁혁준;한풍규;조원국
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2003년도 제21회 추계학술대회 논문집
    • /
    • pp.78-82
    • /
    • 2003
  • 우주발사체의 2단용 엔진으로 10톤급 케로신 재생 냉각 방식의 액체로켓엔진에 대한 보조 냉각 기구로서, 막냉각을 고려한 냉각특성에 대한 해석적 연구를 수행하였다. 연소기내에서 연소가스의 유동이 축방향으로 층류화되어 있다는 개념하에, 엔진 단면을 서로 독립적인 중심부와 외곽부로 나누며, 외곽부에는 여분의 연료를 분무시킴으로써 연소가스 온도를 낮추어 냉각채널로 전달되는 열유속량과 벽면 온도를 감소시킬 수 있었으며, 엔진의 열적 안정성을 향상시킬 수 있었다.

  • PDF