• 제목/요약/키워드: Cooling loss

검색결과 567건 처리시간 0.029초

하나로 2차 냉각탑의 냉각능력 평가 (Evaluation for the Cooling Capability of Secondary Cooling Tower in HANARO)

  • 박용철;우종섭;조영갑;류정수
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2000년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.345-350
    • /
    • 2000
  • The heat produced by the fission in the fuel of HANARO, 30 MW research reactor, is transferred from the primary cooling water to the secondary cooling water through heat exchangers, and the heat absorbed by the secondary cooling water is released into the atmosphere by the 33 MW cooling tower which is a mechanical induced draft and counter flow type. If the outlet temperature of cooling tower exceeds 33 of due to the loss of the cooling tower performance under reactor operation above $50\%$ of the full power, the reactor power should be reduced to half of the full power for safe operation. Therefore, the cooling capability of cooling tower should be maintained for the reactor to be normally operated. To predict the capability of cooling tower for full power reactor operation of 30 MW, the performance test of cooling tower was done at the reactor present power of 24 MW and the capability was respectively evaluated by characteristics and performance curves methods in accordance with the Code of Cooling Tower Institute of U.S.A. to confirm the reliability of evaluation. As a result, it was confirmed, through the results of each evaluation, that the cooling capability of cooling tower meets the design required heat load. Also, the equations of the performance and the characteristics curves of the cooling tower, based on the collected data during this performance test, was obtained for developing the calculation program to predict the cooling capability during reactor operation.

  • PDF

아파트 냉각탑의 소음 평가 및 대책 (Noise Evaluation and Measures of Cooling Tower at Apartment)

  • 이규배
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.1020-1023
    • /
    • 2004
  • Recently, Cooling tower are used the necessary element in a residential area and living space on the viewpoint of indoor temperature control. The purpose of this study is to assistance the comfortable environment and economical measures of noise transmission mechanism on tile cooling tower. The results show that noise evaluation interact the main factor of distance reduction and diffraction reduction. Noise criterion apply to the NC level and equivalent transmission loss about already the design of noise reduction.

  • PDF

Intermittent Heating and Cooling Load Calculation Method -Comparing with ISO 13790

  • Lee, Sang-Hoon
    • Architectural research
    • /
    • 제14권1호
    • /
    • pp.11-18
    • /
    • 2012
  • College of Architecture, Georgia Institute of Technology, Atlanta, GA, US Abstract The intermittent heating and cooling energy need calculation of the ISO 13790 monthly method was examined. The current ISO 13790 method applies a reduction factor to the continuous heating and cooling need calculation result to derive the intermittent heating and cooling for each month. This paper proposes a method for the intermittent energy need calculation based on the internal mean temperature calculation. The internal temperature calculation procedure was introduced considering the heat-balance taking into account of heat gain, heat loss, and thermal inertia for reduced heating and cooling period. Then, the calculated internal mean temperature was used for the intermittent heating and cooling energy need calculation. The calculation results from the proposed method were compared to the current ISO 13790 method and validated with a dynamic simulation using EnergyPlus. The study indicates that the intermittent heating and cooling energy need calculation method using the proposed model improves transparency of the current ISO 13790 method and draws more rational outcomes in the monthly heating and cooling energy need calculation.

더운환경에서의 냉각조끼의 착용효과에 관한 연구 (Effectiveness of Cooling Vest in Hot Environment)

  • 최정화;황경숙
    • 한국의류학회지
    • /
    • 제25권1호
    • /
    • pp.83-90
    • /
    • 2001
  • Cooling garments are being considered for reducing heat strain in hot environment. We evaluated the effectiveness of ice gel-based cooling vest in hot environment both resting and exercising. Four male subjects were exposed to heat(4$0^{\circ}C$, 50%RH) with vest or without it. The results were as follows; In case of the trial wearing ice gel-based cooling vest, total body weight loss, and local sweat volume were less than those without it. Mean skin temperature, rectal temperature, pulse, energy expenditure, temperature of inside clothes, and humidity of inside also were lower than those without cooling vest. By subjective thermal sensation, subjective humidity sensation, and thermal comfort sensation, it was proved that non-wearing vest decreased comfort than wearing that. These results suggested that wearing ice gel-based cooling vest reduced human heat strain in hot environment both resting and exercising.

  • PDF

흡습 냉각 원리를 이용한 소형 냉각 패드에 관한 연구 (Conceptual Development of a Subminiature Cool Pad Applying Sorption Cooling Effect)

  • 황용신;이대영;김우승
    • 설비공학논문집
    • /
    • 제16권2호
    • /
    • pp.121-127
    • /
    • 2004
  • This paper describes conceptual development and idea-verification of a sub-miniature portable cooler which dose not necessitate any pre-cooling nor any external energy supply. The basic principle of the cooling mechanism is the vaporization of water and sub-sequent cooling due to the evaporative latent heat loss. In this work, the vaporization of the water is stimulated by desiccant material to improve the cooling effect. The evaporative cooling caused by the desiccant is modeled and analyzed considering the sorption characteristics of the desiccant. In addition, the portable cooler is fabricated in the shape of a thin pad, and its cooling characteristics are tested and compared with the analytic results.

VM열펌프의 2차해석 (A Second-Order Analysis of VM Heat Pumps)

  • 최연석;정은수
    • 설비공학논문집
    • /
    • 제8권2호
    • /
    • pp.208-218
    • /
    • 1996
  • Performance of a VM heat pump is considerably affected by various losses, such as enthalpy dump, reheat loss, pumping loss, conduction loss and shuttle loss. A second-order analysis model of VM heat pumps, which allows consideration of the major losses, was presented. Actual heat transfer rates for heat exchangers were calculated from the heat transfer rates obtained by the adiabatic analysis and various losses. New effective temperatures of heat exchangers were calculated from the actual heat transfer rates and the mean heat transfer coefficients until there was no appreciable change in the effective temperatures. Effects of design parameters, such as phase angle, swept volume ratio, regenerator length and speed on heating capacity, cooling capacity and COP were shown.

  • PDF

냉매충전량이 초임계 이산화탄소 사이클의 냉방성능에 미치는 영향에 대한 연구 (Effects of Refrigerant Charge Amount on the Cooling Performance of a Transcritical $CO_{2}$ Cycle)

  • 조홍현;류창기;김용찬;심윤희
    • 설비공학논문집
    • /
    • 제17권5호
    • /
    • pp.410-417
    • /
    • 2005
  • The cooling performance of a transcritical $CO_{2}$ cycle varies significantly with a variation of refrigerant charge amount. In this study, the performance of the $CO_{2}$ system was measured and analyzed by varying refrigerant charge amount at a standard test condition. Besides, the losses of the major components in the $CO_{2}$ system were estimated by evaluating entropy generation with refrigerant charge amount. The losses in the expansion device and the gascooler show the major portion of the total loss. For undercharging conditions, the expansion loss dominates the overall system performance, while the gascooler loss increases significantly with an increase of refrigerant charge amount.

수확 후 전처리에 의한 고랭지 배추 '춘광' 품종의 저온 저장 중 품질 변화에 대한 비교 (Comparison of the Quality of Highland-Grown Kimchi Cabbage 'Choon Gwang' during Cold Storage after Pretreatments)

  • 배상준;엄향란;김병섭;윤정로;홍세진
    • 원예과학기술지
    • /
    • 제33권2호
    • /
    • pp.233-241
    • /
    • 2015
  • 강원도 강릉에 위치한 고랭지 지역에서 재배된 배추 '춘광' 품종은 수확 직후 차압식예냉, 통풍식예냉, 예건 처리를 하였고, 전처리 후 각각 처리에 대해 0.02mm HDPE film으로 liner 처리 유무에 따라 분류한 다음 $2^{\circ}C$에 저장을 하면서 품질 조사를 실시하였다. 저장 중 무게 손실은 liner 처리구에서 차압예냉이 3% 미만의 손실률을 보였고, 통풍예냉 또한 4% 미만의 손실률을 보였다. 그러나 liner 무처리 구에서는 통풍예냉이 10% 미만의 손실률을 보였고, 차압예냉의 경우 15% 이상으로 가장 많은 손실률을 보였으며, 오히려 대조구가 손실률이 가장 적었다. 가용성고형물의 경우 $2-4^{\circ}brix$ 정도로 나타났으며, 색도는 CIE $L^*$ 값은 50 내외로 큰 차이를 보이지 않았고, hue angle 값은 조금씩 감소하였으나 $120{\pm}2^{\circ}C$ 사이 녹색의 범위 안에 분포하여 색의 변화에 대한 차이는 없었다. Chroma 값의 경우에도 28-32 사이에 분포하였다. 경도는 22N 정도로 나타났으며, 처리에 따른 유의적 차이는 보이지 않았다. 관능 평과 결과, 외관과 아삭거림 정도의 경우 차압예냉을 실시한 후 liner를 적용한 배추에서 가장 좋은 결과가 나타났으며, 나머지 항목에서는 유의적 차이가 없었다. 저장 6주 경과 후 liner 무처리구에서 외관이 많이 손상되었고, 7주 경과 후 liner 처리구에서 통풍예냉과 예건에서 내부 갈변이 심하게 발생하였다.

채널의 분기 및 병합이 있는 액체로켓 연소기 재생냉각 유로에서의 수력학적 특성 (Hydraulic Characteristics of Branching and Merging of Channels in Regenerative Cooling Passage in Liquid Rocket Combustors)

  • 김홍집;김성구;최환석
    • 한국항공우주학회지
    • /
    • 제36권11호
    • /
    • pp.1087-1093
    • /
    • 2008
  • 고성능 로켓엔진용 연소기에서 열적 건전성을 확보하기 위해 적용되는 재생냉각 채널은 채널의 분기/병합, 방향 전환과 같이 복잡한 유동구조를 포함한다. 냉각유로에서 발생하는 압력 손실을 마찰과 국소유동저항으로 나눠, 각각의 유동조건에 따라 경험적으로 제시된 문헌상의 계수를 적용함으로써, 재생냉각유로 설계에 효과적으로 적용할 수 있도록 수력학적 자료를 구하였다. 해석의 타당성을 검증하기 위하여 실물형 연소기의 냉각유로 설계안에 적용하였다. 먼저, 물을 사용하였을 때 모사시제를 사용한 수류시험 결과와 비교하였다. 정량적으로 타당한 결과를 얻은 것으로 확인되어, 실유체인 케로신을 사용한 수력해석을 수행하여 CFD 결과와 비교하여 수력해석 방법의 타당성을 확인할 수 있었다.

막냉각에 따른 추력실의 냉각 성능 (The Cooling Performance of Thrust Chamber with Film Cooling)

  • 김선진;정해승
    • 한국군사과학기술학회지
    • /
    • 제9권1호
    • /
    • pp.117-124
    • /
    • 2006
  • Experiments on film cooling were performed with a small scale rocket engine homing liquid oxygen (LOx) and Jet A-1(jet engine fuel). Film coolants(Jet A-1 and water) were injected through the film cooling injector. Film cooled length and the outside wall temperature of the combustor were determined for chamber pressure, and the different geometries(injection angle) with the flow rates of film coolant. The loss of characteristic velocity due to film cooling was determined for the case of film cooling with water and Jet A-1. As the coolant flow increases, the outside wall temperatures decrease but the decrease in the outside wall temperatures reduced over the 8 percent film coolant flow rate. The efficiency of characteristic velocity was decreased with the Increase of the film coolant flow rate.