• 제목/요약/키워드: Cooling load prediction

검색결과 52건 처리시간 0.021초

부하예측 외기냉방에 의한 건물에너지 절약에 관한 연구 (A Study on Building Energy Saving using Outdoor Air Cooling by Load Prediction)

  • 김태호;유성연;김명호
    • 설비공학논문집
    • /
    • 제29권2호
    • /
    • pp.43-50
    • /
    • 2017
  • The purpose of this study is to develop a control algorithm for outdoor air cooling based on the prediction of cooling load, and to evaluate the building energy saving using outdoor air cooling. Outdoor air conditions such as temperature, humidity, and solar insolation are predicted using forecasted information provided by the meteorological agency, and the building cooling load is predicted from the obtained outdoor air conditions and building characteristics. The air flow rate induced by outdoor air is determined by considering the predicted cooling loads. To evaluate the energy saving, the benchmark building is modeled and simulated using the TRNSYS program. Energy saving by outdoor air cooling using load prediction is found to be around 10% of the total cooling coil load in all locations of Korea. As the allowable minimum indoor temperature is decreased, the total energy saving is increased and approaches close to that of the conventional enthalpy control.

수경온실의 양액 냉각부하 예측모델 개발 (Development of a Numerical Model for Prediction of the Cooling Load of Nutrient Solution in Hydroponic Greenhouse)

  • 남상운;김문기;손정익
    • 생물환경조절학회지
    • /
    • 제2권2호
    • /
    • pp.99-109
    • /
    • 1993
  • Cooling of nutrient solution is essential to improve the growth environment of crops in hydroponic culture during summer season in Korea. This study was carried out to provide fundamental data for development of the cooling system satisfying the required cooling load of nutrient solution in hydroponic greenhouse. A numerical model for prediction of the cooling load of nutrient solution in hydroponic greenhouse was developed, and the results by the model showed good agreements with those by experiments. Main factors effecting on cooling load were solar radiation and air temperature in weather data, and conductivity of planting board and area ratio of bed to floor in greenhouse parameters. Using the model developed, the design cooling load of nutrient solution in hydroponic greenhouse of 1,000$m^2$(300pyong) was predicted to be 95,000 kJ/hr in Suwon and the vicinity.

  • PDF

열환경챔버의 냉방 시뮬레이션 프로그램 개발에 관한 연구 (A Study on the Development of Cooling Simulation Program for Thermal Environmental Chamber)

  • 이한홍
    • 한국생산제조학회지
    • /
    • 제8권5호
    • /
    • pp.108-114
    • /
    • 1999
  • The thermal environmental chamber has been using in maintaining weather condition keeping thermal capacity under heating and cooling load fluctuation and for the performance testing of cooling system or air-conditioner on artificial envi-ronment. In ordder to make the various environmental conditions in the thermal environmental chamber the proper cooling system is necessary to eliminate the heating load produced inside the chamber and to maintain the designed environmental condition. For this reason the optimal design of cooling system and the prediction of performance is also required. This paper describes the prediction of performance of cooling system in the thermal environmental chamber with the capacity of 37,000kcal/hr which is developed for the test of performance in heating mode of heat pump system, In the results this paper is trying to develop simulation program on the base of mathematical models and which can be applied effectively to the optimal design of cooling system and prediction of performance to the inside and outside change of envi-ronmetal load.

  • PDF

건물 면적을 이용한 시간별 냉방부하 예측에 관한 연구 (A Study on Prediction of Hourly Cooling Load Using Building Area)

  • 유성연;한규현
    • 설비공학논문집
    • /
    • 제22권11호
    • /
    • pp.798-804
    • /
    • 2010
  • New methodology is proposed to predict the hourly cooling load of the next day using maximum/minimum temperature and building area. The maximum and minimum temperature are obtained from forecasted weather data. The cooling load parameters related to building area are set through a database provided from reference buildings. To validate the performance of the proposed method, the predicted cooling loads in hourly bases are calculated and compared with the measured data. The predicted results show fairly good agreement with the measured data for benchmarking building.

창원시 학교 건축물의 냉난방부하에 대한 전력 소비량 추정에 관한 연구 (A Study on Prediction of Power Consumption Rate for Heating and Cooling load of School Building in Changwon City)

  • 박효석;최정민;조성우
    • 교육녹색환경연구
    • /
    • 제11권2호
    • /
    • pp.19-27
    • /
    • 2012
  • This study was carried out in order to establish the estimation equation for school power consumption using regression analysis based on collected power consumption for two years of weather data and schools are located in Central Changwon and Masan district in Changwon city. (1) The power consumption estimation equation for Heating and cooling is calculated using power consumption per unit volume, the difference between actual power consumption and results of estimation equations is 4.1%. (2) The power consumption estimation equation for heating load is showed 2.6% difference compared to actual power consumption in Central Changwon and is expressed 2.9% difference compared to that in Masan district. Therefore, the power consumption prediction for each school using the power consumption estimation equation is possible. (3) The power consumption estimation equation for cooling load is showed 8.0% difference compared to actual power consumption in Central Changwon and is expressed 2.9% compared to that in Masan district. As the power consumption estimation equation for cooling load is expressed difference compared to heating load, it needs to investigate influence for cooling load.

Development of Load Prediction Equations of Office Buildings

  • Seok, Ho-Tae;Kim, Kwang-Woo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제10권2호
    • /
    • pp.65-71
    • /
    • 2002
  • The objective of this study is to evaluate the design parameters and to develop the cooling and heating load prediction equations of office buildings. The building load calculation simulation was carried out using the DOE-2.1E program. The results of the simulation were used as data for multiple regression analysis which could develop the load prediction equations.

사무소 건설의 설계변수 열성능 평가 및 부하예측방정식 개발 (Thermal Performance Evaluation of Design Parameters and Development of Load Prediction Equations of Office Buildings)

  • 석호태;김광우
    • 설비공학논문집
    • /
    • 제13권9호
    • /
    • pp.914-921
    • /
    • 2001
  • The objective of this study is to evaluate the design parameters and to develop the cooling and heating load prediction equations of office buildings. The building load calculation simulation was carried out using the DOE-2.1E program. The results of the simulation was used as a data for ANOVA and multiple regression analysis which could develop the load prediction equations.

  • PDF

창의 기울기에 따른 건축물 에너지 소비량 예측 (The Prediction of Energy Consumption by Window Inclination)

  • 조성우
    • 한국태양에너지학회 논문집
    • /
    • 제31권5호
    • /
    • pp.27-32
    • /
    • 2011
  • Most of domestic building generally don't have fixed shading devices considering of appearance and aesthetic issues. In this study is suggested that tilt window simultaneously has a role of shading and blocking solar radiation. The tilt window thermal performance is investigated by relation ship between inclination and heating cooling road. As comparing vertical window with $5^{\circ}$ and $7^{\circ}$ of tilt window respectively, the heating load is increased by 3.6% and cooling load is reduced by 8.1% on $5^{\circ}$ tilt window and the heating load is increased by 5.3% and cooling load is reduced by 11.5% on $5^{\circ}$ tilt window. Especially, the total load of alternative tilt window is showed the reduction rate 2.6% and3.6% compared of vertical window. Therefore, the tilt window is possible to role of shading of solar radiation and reduction of heating and cooling load.

직달일사를 이용한 잠열축열식 바닥난방 시스템이 냉방부하에 미치는 영향에 대한 검토 (Effects of Phase Change Material Floor Heating Systems using Direct Solar Gain on Cooling Load)

  • 김수경
    • 한국태양에너지학회 논문집
    • /
    • 제33권3호
    • /
    • pp.9-16
    • /
    • 2013
  • In this research, the effect of a heating system, which is powered by direct solar energy accumulated in phase change material (PCM) as heat storage material installed on the floor surface, on the cooling load was studied. Cooling load of a test building designed for this research was measured with fan coil unit and factors affecting it were also estimated. Experiments were performed with and without PCM installed on the building floor to understand the effect of the PCM on the cooling load. Additionally, to confirm the experiments results, the prediction calculation formula by average outside temperature and integrated solar radiation was composed using multivariate regression model. The results suggested that the heating system with PCM on the floor surface has the potential to shift electric power peak by radiating heat, stored during the daytime in it, at night, not increasing the total cooling load much.

냉방부하에 영향을 미치는 외기 환경조건의 상관관계에 관한 연구 (A Study on Correlation of Outdoor Environmental Condition about Cooling Load)

  • 이제묘
    • 설비공학논문집
    • /
    • 제24권11호
    • /
    • pp.759-766
    • /
    • 2012
  • To estimate the cooling load for the following day, outdoor temperature and humidity are needed in hourly base. But the meteorological administration forecasts only maximum and minimum temperature. New methodology is proposed for predicting hourly outdoor temperature and humidity by using the forecasted maximum and minimum temperature. The correlations for normalized outdoor temperature and specific humidity has been derived from the weather data for five years at Seoul, Daejeon and Pusan. The correlations for normalized temperature are independent of date, while the correlations for specific humidity are linearly dependent on date. The predicted results show fairly good agreement with the measured data. The prediction program is also developed for hourly outdoor dry bulb temperature, specific humidity, dew point, relative humidity, enthalpy and specific volume.