• 제목/요약/키워드: Cooling heating energy consumption

검색결과 281건 처리시간 0.024초

도시기반 에너지공급시스템의 최적화 방안 연구 (A Study on the Optimal Design of Urban Energy Supply Systems)

  • 김용기;이태원;우남섭
    • 대한기계학회논문집B
    • /
    • 제33권6호
    • /
    • pp.396-402
    • /
    • 2009
  • Recently many efforts have been carried out on the development of energy-efficient and environment-friendly systems in order to preserve natural environment and to reduce environmental loads in the branch of the urban planning and the building design. In this study, a mathematical method was developed and a numerical analysis was carried out with various parameters to provide substantial data for optimal design and operation of urban energy supply systems. Components of the system and their specifications, such as a co-generation system and other heating and cooling systems, could be obtained through this analysis for various resource and energy requirements in urban area. In this study, the system constituents and operating characteristics, and their economic performances such as the value of objective function, the amount of energy consumption were discussed for various load patterns and power load ratios. Also, it turns out that the optimal energy supply system can save energy by $10{\sim}20%$ in comparison with the conventional energy supply system.

민감도 분석을 통한 종합병원 병동부의 에너지 절감 외피 설계요소 도출 (A Study on Envelope Design Variables for Energy Conservation of General Hospital Ward Area by Sensitivity Analysis)

  • 오지현;권순정;김선숙
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제23권1호
    • /
    • pp.7-14
    • /
    • 2017
  • Purpose: Since the large hospitals are one of the most intensive energy users among building types in Korea, it is important to investigate and apply appropriate energy conservation measures. There are many researches on energy conservation measures for HVAC system in hospitals, but only few useful guidelines for envelope design variables were existed. The building envelope is one of the important factors to building energy consumption and patients' comfort. The purpose of this study is to suggest the most influential envelope design variables for each end-use energy demand. Methods: 100 samples were generated by LHS(Latin Hypercube Sampling) method. After energy performance simulation, global sensitivity analysis was performed by the regression method. DesignBuilder, Simlab 2.2 and JEPlus were used in this process. Results: The most influencing variables are SHGC, SHGC and VT for heating, cooling, and lighting, respectively. However, the most influencing variable for total energy demand is WWR(Window to Wall Ratio). The analysis was conducted based on the coefficient of variance results. Implications: The six envelop design variables were ranked according to the end-use energy demand.

다공질 장석으로 제조한 축열층의 열전도 특성 (Thermal Conductivity Effect of Heat Storage Layer using Porous Feldspar Powder)

  • 김성욱;고대홍;최은경;김성환;김태형;이규환;조진우
    • 자원환경지질
    • /
    • 제50권2호
    • /
    • pp.159-170
    • /
    • 2017
  • 다공성 구조의 장석과 주택 시방기준으로 제작된 바닥 축열층 모르타르의 열적 특성과 소비전력을 비교하였다. 실험을 위해 온수관이 설치된 2개의 실대형 모형을 제작하였다. 자외선 열화상 온도와 온도센서를 이용하여 가열과 냉각과정에서 축열층의 온도변화를 모니터링하였다. 시험동의 축열층은 $20-30^{\circ}C$ 구간의 온도 범위의 가열조건에서 $2-3.5^{\circ}C$ 높은 온도를 보였고 목표 온도에 도달하는 시간이 단축되었다. 온수관에서 멀어질수록 $4-4.8^{\circ}C$ 이상의 차이를 보였고 이는 장석 기반의 모르타르 축열층이 열적 평형에 빨리 도달하는 것을 지시한다. 가열 온도 $30^{\circ}C$를 기준으로 산정한 소비전력은 2.2배 차이를 보였고 단계별 온도 상승에서 소비전력은 66% 절감되었다. 냉각에서 시험동의 표면온도는 지속해서 $2^{\circ}C$ 이상 높았고 축열로 인해 보일러의 재가동 시간이 연장되는 것을 고려하면 에너지 효율은 더 증가할 것이다.

주거건물용 이중외피 시스템의 블라인드 조절에 따른 에너지 성능평가에 관한 연구 (Energy Performance Evaluation of a Double-skin Facade with a Venetian Blind in Residential Buildings)

  • 이소연;강재식;김강수
    • 한국태양에너지학회 논문집
    • /
    • 제30권6호
    • /
    • pp.1-9
    • /
    • 2010
  • Apartment balcony has been remodeled since the government permitted remodeling in January 2006.But extended balcony has great impact on building heat gain and loss. Therefore It has problems such as increase of heating and cooling energy. So $\underline{t}echnical$ solutions about window solar gain in summer is an urgent matter. The Purpose of this study is to evaluate energy performance of a blind in a double-skin facade in residential buildings by using EnergyPlus program. The results show that slat angles of $90^{\circ}$ is best in energy performance if we do not consider daylight. Poorly daylighted living room needs electric light and it also causes high cooling load. On the other hand, the results show that the application of blinds controlled automatically is best for energy performance when we consider daylight. Blind slat angles of $50\sim60^{\circ}$ have best performance when blinds are controlled in this angle throughout the day on a clear day in August. Blind slat angles of $0\sim30^{\circ}$ have best performance when blinds $\underline{are\;controlled}$ in this angle throughout the day on a cloudy day (more than 7 of total sky cover) in August.

마이크로기포제를 사용한 콘크리트의 열적 특성에 관한 연구 (Study on the Thermal Characteristics of Concrete Using Micro Form Admixture)

  • 박영신;김정호;전현규;서치호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권2호
    • /
    • pp.101-109
    • /
    • 2013
  • 최근 전세계는 급격한 기후조건과 환경변화에 의해 냉난방 에너지 사용이 증가되고 있으며 이는 화석 연료 사용량 증가와 함께 $CO_2$ 배출량 상승, 지구 온난화 등 환경과 에너지에 대한 수많은 문제를 유발하고 있어 세계 각국은 온실가스 배출 및 에너지 소비 감소를 위한 대응책을 마련하고 있다. 우리나라 또한 정부의 '저탄소 녹색 성장' 및 '친환경 주택 건설기준 및 성능' 등의 정책을 선포하는 등 건물 부분에 있어 환경과 에너지 관리에 대한 노력을 하고 있다. 우리나라의 총 에너지 소비량 중 건물 부문이 차지하는 비율은 약 25%에 달하며 다른 산업 분야에 비해 연간 에너지 소비 증가율이 높은 편이다. 건물에서 에너지 손실이 가장 큰 부위는 외피로서, 이 부분의 에너지 손실을 감소하기 위한 연구가 활발히 진행되고 있으나 이는 대부분 창호 및 단열재를 사용한 연구이며 건물 외피의 70% 이상을 차지하고 있는 콘크리트에 대한 연구는 미미한 실정이다. 따라서 건물의 에너지 손실을 최소화하기 위해서는 콘크리트 자체에서 단열성능을 확보할 수 있어야 하며 이에 대한 연구가 필요하다. 따라서 본 연구는 콘크리트의 단열성능을 확보하면서 구조용으로 사용이 가능한 콘크리트를 개발하기 위한 실험을 진행하였다. Test 1의 실험결과로써, Micro Foam Admixture (MFA)를 사용한 콘크리트는 슬럼프 경시변화가 개선되었으며, MFA의 혼입율을 증가할 경우 압축강도는 감소되고 열전도율은 증가되는 결과를 나타내었다. Test 2의 실험결과에서는 물시멘트비 변화시 물시멘트비 증가에 따라 압축강도는 감소하였고 열전도율은 증가하였다. 그러나 잔골재율 변화에 대한 물성 및 열적 특성은 큰 차이를 나타내지 않았다.

교육 시설기준 변화에 따른 학교건축물의 에너지원 변화에 관한 연구 (A study on the Energy resource in School Buildings with the Changes of Educational Facilities Standard)

  • 김태우;이강국;홍원화
    • KIEAE Journal
    • /
    • 제10권6호
    • /
    • pp.73-80
    • /
    • 2010
  • Since the Korean War, Korea has experienced modernization. The population increase by baby booming has asked for more space for educational facilities. In such a situation, the purpose of educational facilities was to accommodate continuously increasing students, rather than seeking for quantitative demands. In addition, in accordance with social changes, educational shifts were required. After the revision of the seventh national curriculum in education in 1997, the school buildings became varied. The design of buildings in accordance with educational curriculum has been improved, but still lack of forming comfortable environment and considering energy efficiency in school buildings. For the improvement of educational environments, educational media such as TV and computers have been provided, and energy systems, including heating and cooling systems, has been continuously increased. As a result, it appeared that energy use in school buildings and facilities has been steadily increased and that the structure of energy consumption has been also changed, especially with regard to electricity use. Living in the 21st century, human beings face global environmental issues, such as global warming, geographical climate changes, and ozone destruction that are the consequences of fossil energy use. Therefore, even in industrial areas, considering a counterplan for low energy use is being paid attention. Starting with Kyoto Protocol in 1992, people try to decrease carbon dioxide and to develop alternative energies (i.e. natural energy); for example, solar energy, wind force, terrestrial heat, and water power. Advanced countries already set up a criterion for $CO_2$ decrease ranging from office buildings to residential houses and also propose alternatives for the $CO_2$ decrease. However, there is no such a plan for low energy use and $CO_2$ decrease in school facilities, and any research on the actual conditions was not accomplished. Thus, this study examines energy demand in classrooms that take up a large portion of energy demand in school building structure.

The Energy Analysis and Evaluation of the NEO-Hanok

  • Han, Sang Hee;Park, So Yeon;Park, Hyo Soon
    • KIEAE Journal
    • /
    • 제14권2호
    • /
    • pp.77-86
    • /
    • 2014
  • Plenty of efforts have been made in the traditional architecture of Korea, Hanok, to develop various elements such as restoration, the introduction of new design, and energy-saving while systemic setups on standard and evaluation of eco-friendly energy design of Hanok are lacking. If we evaluate energy performance based on current standards without reflecting unique features of Hanok on the system, Hanok will be included in the very low grade among the residential buildings being included in the approval system of eco-friendly architecture or the unique features will be modified and the burden of increased construction cost. Therefore, this study is to prepare the basic reference for the introductory evaluation system by evaluating the energy performance level of NEO-Hanok based on the current building energy rating system. The result for NEO-Hanok based on the building energy rating system, we propose the rating standard with scorecard elements of NEO-Hanok by considering the necessity of identity and standard for NEO-Hanok. As a result of infiltration test to check the tightness, it was measured as 10.81 times/h (50 ACH). As we switch from the main insulation for the wall from the glass wool 64k(0.035W/mk) to rigid polyurethane foam first class first unit (0.024W/mk), the result was slightly increased from the first demand quantity rating yield $249.8kWh/m^2{\cdot}yr$ to $235.0kWh/m^2{\cdot}yr$. Current certificate system is focused more on the heating load than the cooling load, it is disadvantageous for Hanok, which has less cooling energy consumption in summer. The rating result from the target building study is level 4.

가스엔진 구동 건물에너지 통합 공급시스템 개발을 위한 기술동향 사례연구 (Integrated Building Energy Supply System : An Overview of Technical Trends for Gas Engine Driven Combined Heat and Power System)

  • 박병용;정용대;신현철;조진균
    • 설비공학논문집
    • /
    • 제29권11호
    • /
    • pp.612-620
    • /
    • 2017
  • Power consumption in Southeast Asia is steadily increasing due to industrialization and the effects of hot and humid climates. However, there are not enough energy generation facilities and infrastructures to meet the growing demand because it is difficult to secure the construction and operation costs of the transmission and distribution systems. This study aims to develop a gas engine driven heat pump system that supplies heating, cooling and electric power to buildings. This system, besides its normal function to produce heat, has the capacity to generate electricity on a household level. This paper investigates similar cases overseas before developing the system. Through the investigation of commercialized similar systems, the level of technology and market trend of development system were identified. Features and specifications of commercial and industrial systems will be used for system development.

A Study on the Development of Building Envelope Elements for Energy Reduction in Multi- Rise Residential Buildings

  • Lee, Myung Sik
    • Architectural research
    • /
    • 제18권4호
    • /
    • pp.151-155
    • /
    • 2016
  • It is necessary to improve the performance of buildings with respect to the energy efficiency while improving the quality of occupants' lives through a sustainable built environment. During the design and development process, building projects must have a comprehensive, integrated perspective that seeks to reduce heating, cooling and lighting loads through climate-responsive designs. The aim of this study is to find an optimal thermal transmittance (U-values) for building envelope elements for low energy multi-rise residential buildings in the early design phase in Korea. The study found that using small U-values of $0.15w/m^2K$ for exterior walls, ceilings and floors and $1.0w/m^2K$ for south and north facing windows has resulted in energy reduction of 22.1%-59.4% in the south facing rooms and 43%-77.6% of the north facing rooms. It has also found the energy load reduction potential of using small U-values are higher on the north facing rooms. The findings of this study can be suggested to be used as a baseline case for low energy consumption studies. It can also be used to determine appropriate envelope materials and insulation values.

메탄올-글리세린을 이용한 재흡수 열펌프의 열역학적 모사 연구 (A Study on a Resorption Beat Pump Using Methanol-Glycerine)

  • 민병훈
    • 에너지공학
    • /
    • 제15권4호
    • /
    • pp.284-290
    • /
    • 2006
  • 냉 난방 수요에서 일어나는 환경오염의 최소화와 화석연료 소비를 감소시키기 위해서 에너지 회수를 개선시키는 것은 필수적이다. 이러한 점에서 흡수식 열펌프기술은 에너지 절약을 위해서 많은 가능성을 가지고 있다. 흡수식 열펌프는 에너지를 주입하지 않고 폐열의 이용을 높일 수 있는 방법이다. 본 연구에서는 에너지 회수를 위한 재흡수 열펌프 연군를 메탄올-글리세린을 이용하여 수행하였다. 이 물질의 열역학 데이터를 이용하여 재흡수 열펌프의 이론적 열효율 값을 각 기관의 조업 조건에 따라서 계산하였다. $70{\sim}80^{\circ}C$의 산업 폐열 온도를 가지고 $40{\sim}50^{\circ}C$ 승온 시킬 때 열효율 값 0.4 이상을 얻을 수 있었다.