• 제목/요약/키워드: Cooling curve

검색결과 183건 처리시간 0.025초

Analysis of Hardenability for Carbon Steel using Finite Element Method(II) (유한요소법을 이용한 탄소강의 경화능해석(II))

  • Kim, O.S.
    • Journal of Power System Engineering
    • /
    • 제3권3호
    • /
    • pp.76-82
    • /
    • 1999
  • This study presents a methodology to predict the hardenability of quenched carbon steels. The equation of transient heat conduction is analyzed to formulate a cooling curve by a finite element method which incorperates coupled effects of temperature on physical properties, the metallic structures and also the latent heat by phase transformation. The volume traction of martensite and pearlite are the structural analysis for hardenability analysis. In order to demonstrate the feasibility of adopting a full quench model respectively. This procedure could be used as the database for optimal condition of heat treatment processes.

  • PDF

Synthesis of Graphene Using 3C-SiC Thin Films with Thermal Annealing Conditions (열처리 조건에 따른 3C-SiC 박막을 이용한 그래핀 합성)

  • Kim, Kang-San;Chung, Gwiy-Sang
    • Journal of Sensor Science and Technology
    • /
    • 제21권5호
    • /
    • pp.385-388
    • /
    • 2012
  • This paper describes the synthesis and characterization of graphene by RTA process. Amorphous 3C-SiC were deposited using APCVD for carbon source and Ni layer were employed for transition layer. Various parameters of the ramping speed, the annealing time and the cooling speed are evaluated for the optimized combination allowed for the reproducible fabrication of graphene using 3C-SiC thin film. For analysis of crystalline Raman spectra was employed. Transferred graphene shows a high IG/ID ratio of 2.73. SEM and TEM images show the optical transparency and 6 carbon network, respectively. Au electrode deposited on the transferred graphene shows linear I-V curve and its resistance is 358 ${\Omega}$.

Heat Sink Design Optimization using Genetic Algorithm (Genetic Algorithm을 활용한 Heat Sink 최적 설계)

  • Kim, Won Gon
    • Proceeding of EDISON Challenge
    • /
    • 제4회(2015년)
    • /
    • pp.500-509
    • /
    • 2015
  • This paper presents the single objective design optimization of plate-fin heat sink equipped with fan cooling system using Genetic Algorithm. The proper heat sink and fan model are selected based on the previous studies. And the thermal resistance of heat sinks and fan efficiency during operation are calculated according to specific design parameters. The objective function is combination of thermal resistance and fan efficiency which have been taken to measure the performance of the heat sink. And Decision making procedure is suggested considering life time of semiconductor and Fan Operating cost. And also Analytical Model used for optimization is validated by Fluent, Ansys 13.0 and this model give a quite reasonable and reliable design.

  • PDF

Genetic Algorithm을 활용한 Heat Sink 최적 설계

  • Kim, Won-Gon
    • CDE review
    • /
    • 제21권2호
    • /
    • pp.39-49
    • /
    • 2015
  • This paper presents the single objective design optimization of plate-fin heat sink equipped with fan cooling system using Genetic Algorithm. The proper heat sink and fan model are selected based on the previous studies. And the thermal resistance of heat sinks and fan efficiency during operation are calculated according to specific design parameters. The objective function is combination of thermal resistance and fan efficiency which have been taken to measure the performance of the heat sink. And Decision making procedure is suggested considering life time of semiconductor and Fan Operating cost. And also Analytical Model used for optimization is validated by Fluent, Ansys 13.0 and this model give a quite reasonable and reliable design.

  • PDF

Numerical study on the flow characteristics in Air-conditioner duct of EMU (전동차 공조기 덕트 내의 유동특성에 관한 수치해석적 연구)

  • Kim Seung-Tech;Kim Sung-Jong;Park Geun-Soo;Park Hyung-Soon
    • Proceedings of the KSR Conference
    • /
    • 한국철도학회 2003년도 추계학술대회 논문집(III)
    • /
    • pp.345-350
    • /
    • 2003
  • The inside of EMU is supplied with the cooling air from air-conditioner and the fresh air from exterior through the air-conditioner duct which is one of the air conditioning system. The shape of air-conditioner duct is a major factor in determining the air-conditioning efficiency, thermal comfort and energy efficiency. Therefore, this study is to understand the flow characteristics in the air-conditioner duct by three dimensional numerical simulation. The air-conditioner duct was calculated for the design volume flow rate, $2,726\;m^3/h/unit$. From the result of calculation and measurement, the velocity at diffuser outlet presented good agreement in general. [n this present study, the calculation was also performed for three volume flow rate(1,800, 2,200, 3,000 $m^3/h/unit$) and total pressure characteristic curve with volume flow rate was presented.

  • PDF

A Analysis of Solidification of Castings by Computer (전산기(電算機)를 이용(利用)한 주물(鑄物)의 응고해석(凝固解析)에 관하여)

  • Yoon, Eui-Pak;Cho, Soon-Hyoung
    • Journal of Korea Foundry Society
    • /
    • 제3권2호
    • /
    • pp.83-91
    • /
    • 1983
  • In this paper analytical and numerical methods fur analysis of solidification of castings are described, and the matrix method, one of numerical method, where the nodal point is designated on the element boundary was adapted. The cooling curve obtained by experimental values, when cast steel (0.29%C. 0.62%Si) was poured into $CO_2$ mold, is compared with that of computed values by exploiting computer (V77-600 Data Proceeding System, UNIVAC). The computed value is nearly approximation to the experimental. But the computed value shows a tendency that is a little higher than the experimental in solid-liquid coexisting temperature ranges and much lower than the experimental after solidification. It is considered to result from the lacks and difficulties of ultimately appropriate adaptation of various physical properties and also air cap between castings and mold.

  • PDF

Thermal Design of IGBT Module with Respect to Stability (IGBT소자의 열적 안정성을 고려한 방열설계)

  • Lee Joon-Yeob;Song Seok-Hyun
    • Proceedings of the KIPE Conference
    • /
    • 전력전자학회 2002년도 추계학술대회 논문집
    • /
    • pp.205-208
    • /
    • 2002
  • Thermal design is required with considering thermal stability to verify the reliability of electric power device with using IGBT. Numerical analysis is performed to analyzed the change in thermal resistance with respect to the various thermal density of heating element. Correlations between thermal resistance and heat generation density are established. With using these correlations, performance curve is composed with respect to the change in thermal resistance of cooling conditions for natural convection and forced convection. Thermal fatigue is occurred at the Inside and outside of IGBT by repeated heat load. The crack is occurred between base plate and ceramic substrate for the inside. When the crack length is 4mm, the failure is occurred. Therefore, Thermal design method considering thermal density, thermal fatigue resistance is presented on this study and it is expected to thermal design with considering life prediction.

  • PDF

Fabrication of YBCO Superconducting Bulk Magnets (YBCO 초전도 벌크 합성)

  • Sang Heon Lee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • 제37권4호
    • /
    • pp.407-411
    • /
    • 2024
  • In this study, we fabricated single grain YBCO bulk superconductors with control of the distance between the seed and the upper surface of the YBCO compacts. The magnetic levitation force of the YBa2Cu3O7 superconducting bulk, which corresponds to the energy amount of the superconducting bulk, was measured to be 32.634 N at the center of the bulk where the seed was placed. Under field cooling conditions, a capture magnetic force of 2.17 kG was observed at the center of the bulk. The trapped magnetic force curve corresponding to the stability of the superconducting bulk means that the superconducting specimens were well grown in the form of single grains.

Microstructures and Mechanical Properties of API J55 steel with Heat treatment conditions and Alloying elements(B, Ti) (API J55강의 미세조직과 기계적 특성에 미치는 열처리 및 합금원소(B, Ti)의 영향)

  • Choi, Jong-Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제19권4호
    • /
    • pp.69-76
    • /
    • 2018
  • This study examined the effect of the heat treatment and alloying elements (B, Ti) on the microstructures and mechanical properties of API J55 steel. The experiments were carried out using various austenization temperatures ($880^{\circ}C$, $910^{\circ}C$, $940^{\circ}C$), cooling methods (water quenching, oil quenching) and tempering temperatures (none, $550^{\circ}C$, $650^{\circ}C$) with J55 and J55+B,Ti steels. The phase diagram and CCT curve were simulated based on the chemical compositions of the J55 and J55+B,Ti steels to predict the microstructures. The results showed that the A1 and A3 temperatures decreased and, as a result, the noses of the ferrite and bainite parts of the CCT curve moved to the right. Various microstructures were formed, namely martensite, bainite, ferrite and pearlite, in accordance with the heat treatment, which had an effect on the hardness, tensile strength and toughness. Martensite was formed after water quenching, but bainite and ferrite appeared after oil quenching with the J55 specimens. On the other hand, martensite was formed, regardless of the cooling method (water quenching, oil quenching), with the J55+B,Ti specimens, because of the improvement of the hardenability caused by the addition of boron. Therefore, the J55+B,Ti specimens exhibited much higher mechanical properties than the J55 specimens, even after the tempering treatment, since the addition of Ti caused fine precipitates to be formed, which inhibited grain growth at the recrystallization temperature.

Evaluation of Fire Performance of RC Slabs with Half-Depth Precast Panels (반단면 프리캐스트 패널을 적용한 RC 슬래브의 내화성능 평가)

  • Chung, Chul-Hun;Im, Cho-Rong;Kim, Hyun-Jun;Joo, Sang-Hoon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • 제30권4A호
    • /
    • pp.391-398
    • /
    • 2010
  • The fire performance of RC slabs with half-depth precast panel after exposure to the ISO-834 fire standard without loading has been experimentally investigated. During heating, according to the ISO 834 fire curve, concrete spalling was observed for concrete without PP(polypropylene) fibers. No spalling occurred when heating concrete containing PP fibers. The maximum temperature of RC slabs with PP fibers with half-depth precast panel was lower than that of concrete without PP fibers. The ultimate load after cooling of the RC slabs that were not loaded during the furnace tests was evaluated by means of 3 points bending tests. The ultimate load of the RC slabs without PP fibers showed a considerable reduction (around 32.5%) of the ultimate load after cooling if compared with of RC slabs with PP fibers. The ultimate load of the RC slabs with half-depth precast panel with PP fibers is higher than that of a full-depth RC slabs with PP fibers. Also, the addition of PP fibers and the use of half-depth precast panel improve fire resistance.