• 제목/요약/키워드: Cooling and heating ratio

검색결과 166건 처리시간 0.026초

VM열펌프의 2차해석 (A Second-Order Analysis of VM Heat Pumps)

  • 최연석;정은수
    • 설비공학논문집
    • /
    • 제8권2호
    • /
    • pp.208-218
    • /
    • 1996
  • Performance of a VM heat pump is considerably affected by various losses, such as enthalpy dump, reheat loss, pumping loss, conduction loss and shuttle loss. A second-order analysis model of VM heat pumps, which allows consideration of the major losses, was presented. Actual heat transfer rates for heat exchangers were calculated from the heat transfer rates obtained by the adiabatic analysis and various losses. New effective temperatures of heat exchangers were calculated from the actual heat transfer rates and the mean heat transfer coefficients until there was no appreciable change in the effective temperatures. Effects of design parameters, such as phase angle, swept volume ratio, regenerator length and speed on heating capacity, cooling capacity and COP were shown.

  • PDF

재생온도가 저온인 경우 제습로터의 재생부/제습부 면적비율과 회전속도 최적화 (Optimization of the Area Ratio of Regeneration to Dehumidification and Rotor Speed on the Condition of Low Regeneration Temperature)

  • 정재동;이대영;윤석만
    • 설비공학논문집
    • /
    • 제19권7호
    • /
    • pp.521-528
    • /
    • 2007
  • The desiccant rotor is the most essential component of desiccant cooling system, but its design relies on manufacturer's experience and principles are not yet clear in spite of a lot of theoretical/experimental work published. The mathematical modeling of desiccant rotor needs solution of coupled partial differential equations of heat and mass transfer. In this study, numerical program is developed and validated using a real desiccant rotor. The calculation results are in reasonable agreement with the experimental data and other available numerical results. Optimization of desiccant rotor on the condition of low regeneration temperature are investigated. The optimal rotor speed at which the process outlet humidity becomes minimized, shows same as that of the system optimization. Compared to high regeneration temperature, broad is the range of optimal speed of low regeneration temperature. Systematic analysis on the optimal area ratio of regeneration to dehumidification section has also been conducted.

도심 오피스건물의 옥상녹화 조성 유형별 건물에너지 절감 비교 연구 (Comparative of Energy-Saving by Green Roof Type on Urban Office Building)

  • 김정호;권기욱;주창훈;윤용한
    • 한국환경과학회지
    • /
    • 제23권8호
    • /
    • pp.1437-1446
    • /
    • 2014
  • This study, the urban energy used office building green roof type composition of the target by analyze building energy reductions. Green roof is total 6 types(type A~F) were selected, EnergyPlus the energy simulation programs were used. Top floor of green roof types evaluation, the reduction of the cooling peak load type E(1.26%), type D(1.30%), type C(1.37%), type B(1.45%), type F(1.49%), and heating peak load is type D(1.32%), type E(1.40%), type C(1.47%), type F(1.69%), type B(2.13%) order. Annual cooling load of heating load is reduced more than about 1% effect. The heating load reduction ratio for a maximum of 9% respectively. Cooling peak load of the building energy performance evaluation of type F > type B > type C > type D > type E in the order and in the case of peak loads heating type B > type F > type D > type E>type C order. Annual total energy use reduction of 1.07 to 1.22% and earn, type B in the best good. In primary energy use reductions in the presence of a green roof were in the 4249~4876 kWh/yr. Annual $CO_2$ emissions reductions of unapplied type A were analyzed on average 469.78 kg.

효과적인 패널 냉각을 위한 대향류형 냉각장치의 개발 (A Development of Counter Flow Type of Cooling System for Effective Panel Cooling)

  • 이중순
    • 한국산학기술학회논문지
    • /
    • 제11권3호
    • /
    • pp.802-807
    • /
    • 2010
  • 산업용 컴퓨터를 포한한 다양한 형태의 공작기계나 자동화 시스템의 배전반이나 제어 패널을 고효율적으로 냉각시킬 수 있는 시스템은 매우 중요한 요소이다. 따라서 이러한 냉각장치는 산업용 로봇, 수치제어 공작기계 등과 같은, 다양한 산업용 시스템에 널리 사용되고 있다. 본 연구에서는 패널 내부를 순환하는 공기를 강제적으로 유동시키는 냉각방식을 채택하여 효과적인 패널 냉각을 위한 대향류형 냉각장치를 개발하였다. 본 연구를 통하여 효과적인 냉각장치를 위한 핀 어셈블리를 개발하여 제어용 패널에 적용한 결과, 기존의 시스템에 비하여 냉각 성능과 열교환율이 개선된 결과를 확인할 수 있었다. 연구에 적용된 상용의 시스템에 비해 공기의 유동량은 약 20% 정도 증가하는 현상을 보였고, 열교환량은 약 2배 이상 증가하는 현상을 확인할 수 있었다.

LiYSiO4: La 열형광체의 온도에 따른 열발광 특성 (Thermoluminescent Properties by the Cooling Temperature and Grain Size in the LiYSiO4 : La Phosphors)

  • 김영국
    • 한국재료학회지
    • /
    • 제19권9호
    • /
    • pp.494-498
    • /
    • 2009
  • The thermoluminescent phosphors of LiYSi$O_4$ containing rare earth metal(La) dopants of 1 wt.%5 wt.% were prepared, and their TL characteristics have been investigated as a function of parameters such as the doping level and the heating rate. The grain size and cooling temperature of the highly sensitive LiYSi$O_4$: La phosphors have been investigated. The glow curve of LiYSi$O_4$: La has two peaks ($P_1,\;P_2$), and the peak height ratio of the two peaks is called $P_2/P_1$; here, the main peak is $P_2$. Experimental results indicate that the peak height ratios of the glow curve for LiYSi$O_4$: La are clearly correlated with the grain size and cooling temperature. The maximum $P_2/P_1$ ratio 3.25, the maximum sensitivity was observed for a grain size between 100-150 ${\mu}m$. The intensity of the TL peak of the phosphors was linearly proportion to the dose of X-rays.

Analysis of restrained steel beams subjected to heating and cooling Part II: Validation and parametric studies

  • Guo, Shi-Xiong;Li, Guo-Qiang
    • Steel and Composite Structures
    • /
    • 제8권1호
    • /
    • pp.19-34
    • /
    • 2008
  • This paper presents the results of a validation and parametric study for the theory presented in the companion paper. The parameters investigated include the stiffness of axial and rotational restraints, load ratio, depth-span ratio of the beam, the yield strength of steel, load type and the temperature distribution in the crosssection of the beam.

사례 분석을 통한 해양심층수의 지역냉방시스템 적용 방안 (Application of District Cooling System for Deep Ocean Water by Case Study)

  • 진수휘;박진영;김삼열;김현주
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 춘계학술발표대회 논문집
    • /
    • pp.179-184
    • /
    • 2011
  • The development of new energy has attracted consideration attention due to the high oil price and environmental problems. In advanced country, they have tried to carry out a long range plan for energy. We need to develop new energy for Low Carbon Green Growth in Korea. The building is 30% among ratio of energy consumption in Korea. And in the past, heating energy was high ratio for energy using at home. But recently, the demand for cooling energy keeps growing due to rising average temperature on the earth and improvement of life quality. In this situation, the energy of lake water and ocean water has studied to utilize in advanced country because of low temperature at underwater. But the study for deep water is still a lot left to do. In this study, we analyzed district cooling system and the present condition. Analyzing the deep lake water cooling system in Toronto, we found an application of district cooling system using deep ocean water. Deep lake water uses heat source for district cooling and water source for city in Toronto. So reducing the initial cost, this city had economic effect. When DLWC was applied at existing building, the heat exchanger was installed instead of cooling tower and refrigerator. And the heat exchanger used to connect main pipe with cool water on city. System using deep ocean water can be applied as a similar way to supply cool water from lake to building.

  • PDF

외기 전용 공조기의 동특성 시뮬레이션 (Dynamic Simulation of a Dedicated Outdoor Air-conditioning System)

  • 김정민;김영일;정광섭;박승태
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.322-327
    • /
    • 2007
  • Dedicated outdoor air-conditioning(DOA) system that utilizes pre-cooling and desiccant dehumidification can be superior to conventional cooling and reheating system with respect to energy consumption and indoor thermal comfort. In this work, simulation has been conducted to study various factors that affect the performance of DOA. Dynamic simulation shows the transient variation of temperature and humidity as the on/off control logic is imposed. Exit humidity of process air and flow rate are varied to study the effect on exit temperature of process air, dehumidification quantity, required regeneration temperature and exit humidity of regeneration air. For an outdoor air condition of $28.5^{\circ}C$ temperature, 16 g/kg humidity ratio and 2000 cmh flow rate, the dehumidification efficiency is increased by 4.6% as the flow rate is doubled.

  • PDF

In-X(X=Pb,Sn) 합금의 마르텐사이트변태거동 특성에 관한 연구 (A Study on the Characteristics of Martensitic Transformation Behaviors in In-X(X=Pb,Sn) Alloys)

  • 한창석;한승오
    • 열처리공학회지
    • /
    • 제23권5호
    • /
    • pp.233-238
    • /
    • 2010
  • The phase transformations and the shape memory effect in In-rich Pb alloys and In rich-Sn alloys have been studied by means of X-ray diffractometry supplemented by metallographic observations. The alloys containing 12~15 at.%Pb transform from the ${\alpha}_2$ (fct) phase to the ${\alpha}_1$ (fct) phase by way of an intermediate phase (m phase) on cooling. The results of X-ray diffraction show that the metastable intermediate phase is observed both on cooling and heating, and has a face-centered orthorhombic (fco) structure. It is concluded that the ${\alpha}_1{\rightleftarrows}{\alpha}_2$ transformation is expressed by the ${\alpha}_1{\rightleftarrows}m{\rightleftarrows}{\alpha}_2$ transformation both on usual cooling and heating with the rate more than $8{\times}10^{-3}$ K/s. The $m{\rightleftarrows}{\alpha}_2$ transformation takes place with a mechanism involving macroscopic shear and are of diffusionless (martensitic) type. The temperature hysteresis in the two transformations is 10~13 K between the heating and cooling transformations. The alloys containing 0~11 at.%Sn are -phase solid solutions with a face centered tetragonal structure (c/a > 1) at room temperature, the axial ratio increasing continuously with tin content. The In-(11~15) at.%Sn alloys are mixtures of ${\alpha}$ and ${\beta}$ phases, the ${\beta}$ phase having a f. c. tetragonal structure (c/a < 1). The alloys containing more than 15 at.%Sn are ${\beta}$-phase solid solutions. The In-(12.9~15.0) at.%Sn alloys show a shape memory effect only when quenched to the temperature of liquid nitrogen, although their effect becomes weak and finally disappears after keeping at room temperature for a long time. The ${\beta}{\rightarrow}{\alpha}^{\prime}$ phase transformation is of the diffusionless (martensitic) type, and takes place between 330 K at 12.9 at.%Sn and 150 K at 14.5 at.%Sn. The hysteresis of transformation temperatures on heating and cooling is considerably large (29~40 K), depending on the composition. Both In-Pb and In-Sn alloys showed distinct the shape memory effects.

외부공기 유입방식에 따른 느타리버섯 생육실의 온도변화 및 자실체의 생육특성 (Heating and cooling properties in cultivation room and cultural characteristics of oyster mushroom according to type of air exchange)

  • 장명준;이윤혜;주영철
    • 한국버섯학회지
    • /
    • 제11권4호
    • /
    • pp.214-218
    • /
    • 2013
  • 외부공기 유입방식에 따른 느타리버섯의 생육특성을 조사하기 위하여 3가지 처리구를 두어 실험한 결과 모든 처리구에서 재배기간 중 온도편차가 발생하였고, 처리구 모두 1, 2, 8월에 가장 높았으며, T2(열교환기)와 T3(기밀실)에서 T1(외부공기 직접유입) 보다 온도편차가 작은 경향이었다. 재배기간 중 냉방시간은 T1(외부공기 직접유입)은 1,090.3시간, T2(열교환기)는 661.1시간, T3(기밀실)은 865.0시간이었고, 평균 냉방절감율은 T1(외부공기 직접유입) 대비 T2(열교환기)는 21%, T3(기밀실)은 11%이었다. 재배기간 동안 난방기의 년중 가동시간은 T1(외부공기 직접유입)은 1,506.9시간, T2(열교환기)는 875.6시간, T3(기밀실)은 1,054.2시간으로 T2의 가동시간이 가장 작았고, 년중 평균 난방절감율은 T1(외부공기 직접유입) 대비 T2(열교환기)는 22%, T3(기밀실)은 16%이었다. 외부공기 유입방식에 따른 냉방정도(CD-H)는 T1(외부공기 직접유입)>T3(기밀실)>T2(열교환기)의 순이었고, 난방정도(HD-H)도 냉방정도(CD-H)의 경우와 동일하였다. 수량은 T2(열교환기)와 T3(기밀실)에서 T1(외부공기 직접유입) 보다 4, 9, 10월을 제외한 전 기간에서 높았다. 이와 같은 결과로 시설재배사에서 느타리버섯 병재배시 열교환기 또는 기밀실을 설치하여 재배할 경우 에너지를 절감할 수 있고, 수량 및 고품질의 느타리버섯을 수확할 수 있어 농가소득증대에 기여할 것으로 판단되었다.