Study on Energy Consumption according to Building Envelope Performance and Indoor Temperature (건축물의 외피성능 및 실내온도에 따른 에너지 사용량에 관한 연구)

  • Yoo, Ho-Chun;Kang, Hyun-Gu
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.3
    • /
    • pp.101-108
    • /
    • 2011
  • This study aims to suggest an energy consumption improvement plan for university buildings through an analysis of energy consumption. Upon a simulation of subject building to interpret energy consumption, it was found that 154.07kWh/$m^2$ of energy is consumpted annually. Improvement of design elements can cut down the energy consumption to 135.61kWh/$m^2$ according to an energy reduction analysis related to envelope performance improvement. Additional improvement of lights and heat exchanger can curtail annual energy consumption to 108.32kWh/$m^2$. Also, an analysis of energy consumption while increasing indoor temperature gradually showed that the two factors are in proportion. $6^{\circ}C$ higher temperature requires over twice of the current energy. Based on this survey result, performance improvement due to building management and envelope elements which influence to building cooling and heating loads can curtail building energy consumption.

COMPARISON OF THE EFFECTS OF THERMAL MASS EXTERIOR WALLS ON HEATING AND COOLING LOADS IN COMMERCIAL BUILDINGS - Evaluation of Delta Load Concept Used in The Draft Standard ASHRAE 90. 1 - (상업용 건물에 있어서 외벽의 축열용량이 난방부하에 미치는 영향 연구 - ASHRAE Standard 90. 1안에서 사용된 Delta Load 개념의 평가 -)

  • Park, Sang-Dong;Kusuda, Tamami
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.15 no.4
    • /
    • pp.372-379
    • /
    • 1986
  • 본고는 상업용 건물에 있어서의 냉난방부하에 대한 외벽의 축열(열용량)효과를 비교$\cdot$분석하는데 그 목적이 있다. 가장 최근에 발표된 에너지 해석 프로그램인 DOE-2.1C를 이용하여 Berkeley Solar Group (BSG) 이 제안한 축열효과를 분석하였다. 본 고에서의 축열효과는 "delta load"로서 표현되어 있으며 "delta load"는 전형적인 나무구조 건물과 벽돌조 건물의 연간 냉난방부하의 차이로서 표시된다. BSG 보고서에 의하면 delta load는 (1)구조물의 위치와 관련한 단열방법 (2)벽의 열용량 (3)벽의 열관류을 (4)기후조건에 따라 달라진다고 되어 있다. 본 고에서의 delta load 계산은 중규모 사무소 건물을 대상으로 하였으며 Lake Charles, LA와 Madison, WI 기후 데이터를 사용하였는데 DOE-2.1C 사용에 의한 delta load는 BSG의 결과와 일반적으로 잘 조화가 되는 것으로 나타났으나 외주부의 방향에 따른 dalta load와 난방에 있어서는 다소 큰 차이를 보여 주고 있으며, 외단열과 중간열의 효과는 BSG의 결과와 마찬가지로 비슷하였다.

  • PDF

Parametric Analysis of Building Energy Impact of Semi-transparent PV (STPV의 건물 에너지 성능에 대한 파라메트릭 분석)

  • Kwak, In-Kyu;Mun, Sun-Hye;Huh, Jung-Ho
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.7
    • /
    • pp.35-42
    • /
    • 2018
  • Semi-transparent Photovoltaics (STPV) works as an exterior material replacing windows as well as functioning as a electricity generator. As a result, it also affects the building's heating, cooling and lighting loads. In this study, we used the concept of Net Electricity Benefit(NEB) to conduct a parametric analysis of building energy impact of STPV. The NEB of STPV is from $-1kWh/m^2$ to $6kWh/m^2$. Since NEB represents the amount of energy increase or decrease when STPV is applied compared to the standard window, a value of 0 or less means that the demand for building energy can be increased rather than applying a general window having high thermal performance and high visible light transmittance value. Therefore, it is necessary to perform a comprehensive performance evaluation considering both the performance evaluation based on the existing power generation performance and the influence on the building energy.

A Study on Analysis Method for Performance Evaluation of Double-leaf facade of Office Building (업무용 건물의 이중외피 성능평가를 위한 해석기법의 고찰 - 이중외피 설계안의 에너지 저감 성능 및 환기성능을 중심으로 -)

  • Chung, Hwan-Kyo;Chung, Kwang-Seop;Lee, Yong-Jun;Shin, Seung-Chul;Kim, Young-Il
    • Journal of Energy Engineering
    • /
    • v.21 no.2
    • /
    • pp.168-178
    • /
    • 2012
  • The objective of this study is applied to office buildings to evaluate quantitative evaluation method about performance of double-skin at design stage to establish the basis for the purpose of evaluation performance. Select the evaluation building about design plan for applying the double-skin using the dynamic heat load analysis program the annual heating and cooling load of before and after the double-skin. Using CFD to analyze wind factor and applied ventilation for realistic results. Effects of double-skin to apply, and control techniques that can be done more realistically proposed through to set and control for shade control mode of ventilator and inside cavity wall of double-skin. Apply for the building the double-skin due to interpretation of the annual heating and cooling loads applied to interpret the quantitative effect confirmed the possibility. According to the form of a double skin was confirmed cavity environmental changes.

A Study on An Integrated GEO/TES with Geothermal Heat Exchanger and Thermal Ice Storage (지중열 교환기와 빙축열조(Thermal Ice Storage)를 연계시킨 통합 지중열-빙축열조 시스템(Integrated GEO/TES))

  • Lohrenz ED.;Hahn Jeongsang;Han Hyuk Sang;Hahn Chan;Kim Hyoung Soo
    • Economic and Environmental Geology
    • /
    • v.38 no.6 s.175
    • /
    • pp.717-729
    • /
    • 2005
  • Peak cooling load of large buildings is generally greater than their peak heating load. Internal and solar heat gains are used fur selection of adquate equipment in large building in cold winter climate like Canada and even Korea. The cost of geothermal heat exchanger to meet the cooling loads can increase the initial cost of ground source heat pump system to the extend less costly conventional system often chosen. Thermal ice storage system has been used for many years in Korea to reduce chiller capacity and shift Peak electrical time and demand. A distribution system designed to take advantage of heat extracted from the ice, and use of geothermal loop (geothermal heat exchanger) to heat as an alternate heat source and sink is well known to provide many benifits. The use of thermal energy storage (TES) reduces the heat pump capacity and peak cooling load needed in large building by as much as 40 to $60\%$ with less mechanical equipment and less space for mechanical room. Additionally TES can reduce the size and cost of the geothermal loop by 1/3 to 1/4 compared to ground coupled heat pump system that is designed to meet the peak heating and cooling load and also can eliminate difficuties of geothermal loop installation such as space requirements and thermal conditions of soil and rock at the urban area.

Study on Thermal Performance of Energy Textile in Tunnel (터널 지열 활용을 위한 에너지 텍스타일의 열교환 성능 연구)

  • Lee, Chulho;Park, Sangwoo;Sohn, Byonghu;Choi, Hangseok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.5
    • /
    • pp.1907-1914
    • /
    • 2013
  • Textile-type heat exchangers installed on the tunnel walls for facilitating ground source heat pump systems, so called "energy textile", was installed in an abandoned railroad tunnel around Seocheon, South Korea. To evaluate thermal performance of the energy textile, a series of long-term monitoring was performed by artificially applying daily intermittent cooling and heating loads on the energy textile. In the course of the experimental measurement, the inlet and outlet fluid temperatures of the energy textile, pumping rate, temperature distribution in the ground, and air temperature inside the tunnel were continuously measured. From the long-term monitoring, the heat exchange rate was recorded as in the range of 57.6~143.5 W per one unit of the energy textile during heating operation and 362.3~558.4 W per one unit during cooling operation. In addition, the heat exchange rate of energy textile was highly sensitive to a change in air temperature inside the tunnel. The field measurements were verified by a 3D computational fluid dynamics analysis (FLUENT) with the consideration of air temperature variation inside the tunnel. The verified numerical model was used to evaluate parametrically the effect of drainage layer in the energy textile.

A Study for the Methodology of Analyzing the Operation Behavior of Thermal Energy Grids with Connecting Operation (열 에너지 그리드 연계운전의 운전 거동 특성 분석을 위한 방법론에 관한 연구)

  • Im, Yong Hoon;Lee, Jae Yong;Chung, Mo
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.1 no.3
    • /
    • pp.143-150
    • /
    • 2012
  • A simulation methodology and corresponding program based on it is to be discussed for analyzing the effects of the networking operation of existing DHC system in connection with CHP system on-site. The practical simulation for arbitrary areas with various building compositions is carried out for the analysis of operational features in both systems, and the various aspects of thermal energy grids with connecting operation are highlighted through the detailed assessment of predicted results. The intrinsic operational features of CHP prime movers, gas engine, gas turbine etc., are effectively implemented by realizing the performance data, i.e. actual operation efficiency in the full and part loads range. For the sake of simplicity, a simple mathematical correlation model is proposed for simulating various aspects of change effectively on the existing DHC system side due to the connecting operation, instead of performing cycle simulations separately. The empirical correlations are developed using the hourly based annual operation data for a branch of the Korean District Heating Corporation (KDHC) and are implicit in relation between main operation parameters such as fuel consumption by use, heat and power production. In the simulation, a variety of system configurations are able to be considered according to any combination of the probable CHP prime-movers, absorption or turbo type cooling chillers of every kind and capacity. From the analysis of the thermal network operation simulations, it is found that the newly proposed methodology of mathematical correlation for modelling of the existing DHC system functions effectively in reflecting the operational variations due to thermal energy grids with connecting operation. The effects of intrinsic features of CHP prime-movers, e.g. the different ratio of heat and power production, various combinations of different types of chillers (i.e. absorption and turbo types) on the overall system operation are discussed in detail with the consideration of operation schemes and corresponding simulation algorithms.

A Study on the Calculation Method of Load standard for ZEB activation (ZEB 활성화를 위한 부하기준 산정 방법 연구)

  • Lee, Hangju;Kim, Insoo
    • Journal of Energy Engineering
    • /
    • v.26 no.4
    • /
    • pp.92-99
    • /
    • 2017
  • In Korea, the zero energy building was designated as the 7 new industries in the Ministry of Land and the 8 new industries in the Ministry of Industry. In order to maximize the insulation performance of the building envelope, improve the efficiency of building equipment, We are aiming. It is necessary to analyze the energy requirements of the buildings (cooling, heating, hot water supply, lighting, ventilation) of buildings with energy efficiency level of 1++ which is equivalent to the zero energy building certification system in Korea, It is aimed to be used as basic data for the advancement of energy building certification system. Zero Energy Building certification is estimated to be 61 buildings by 2017, and the approximate reference value and the first energy requirement for each of the five loads are calculated considering passive and active aspects. It is difficult to say that it is a clear standard because there is a small sample of data for calculating the load standard. However, it is necessary to interpret various methods in order to upgrade the Zero Energy Building certification standard in the future.

Prediction of Transpiration Rate of Lettuces (Lactuca sativa L.) in Plant Factory by Penman-Monteith Model (Penman-Monteith 모델에 의한 식물공장 내 상추(Lactuca sativa L.)의 증산량 예측)

  • Lee, June Woo;Eom, Jung Nam;Kang, Woo Hyun;Shin, Jong Hwa;Son, Jung Eek
    • Journal of Bio-Environment Control
    • /
    • v.22 no.2
    • /
    • pp.182-187
    • /
    • 2013
  • In closed plant production system like plant factory, changes in environmental factors should be identified for conducting efficient environmental control as well as predicting energy consumption. Since high relative humidity (RH) is essential for crop production in the plant factory, transpiration is closely related with RH and should be quantified. In this study, four varieties of lettuces (Lactuca sativa L.) were grown in a plant factory, and the leaf areas and transpiration rates of the plants according to DAT (day after transplanting) were measured. The coefficients of the simplified Penman-Monteith equation were calibrated in order to calculate the transpiration rate in the plant factory and the total amount of transpiration during cultivation period was predicted by simulation. The following model was used: $E_d=a*(1-e^{-k*LAI})*RAD_{in}+b*LAI*VPD_d$ (at daytime) and $E_n=b*LAI*VPD_n$ (at nighttime) for estimating transpiration of the lettuce in the plant factory. Leaf area and transpiration rate increased with DAT as exponential growth. Proportional relationship was obtained between leaf area and transpiration rate. Total amounts of transpiration of lettuces grown in plant factory could be obtained by the models with high $r^2$ values. The results indicated the simplified Penman-Monteith equation could be used to predict water requirements as well as heating and cooling loads required in plant factory system.