• 제목/요약/키워드: Cooling and Heating

검색결과 1,915건 처리시간 0.03초

An Examination of Load Cut-off Effect Using Modern Buildings in Korean Traditional Passive Methods

  • Kim, Hwan-yong;Song, Young-hak;Kim, Hyemi
    • Architectural research
    • /
    • 제19권2호
    • /
    • pp.45-52
    • /
    • 2017
  • Recently, as a new perspective to view the architecture in relation to global environmental problems, interest in environmental architecture that conforms to the surrounding environment and nature with nature has been expanded as a part of the natural ecosystem, rather than seeing the building as an independent entity. Traditional Korean architecture creates a comfortable indoor environment by appropriately using the natural energy around, ranging from the arrangement of the building and the space composition to the use of detailed materials and to harmonize the artificial architectural environment without harming the natural ecosystem. The purpose of this study is to propose a method to apply the environmental control techniques of traditional buildings to modern buildings. As a research method, the characteristics of Korean traditional buildings according to the climatic characteristics of Korea were recognized through existing literature data and when applied to methods of traditional buildings, ventilation systems, control through eaves, and humidity control using Hanji the effect of energy load control on traditional buildings was analyzed and identified through existing literature. After analyzing the problems of modern architecture, we analyzed the effect of the environmental control system of traditional architecture on modern architecture. Simulation results show that the application of the environmental control system of traditional buildings to modern buildings reduces the cooling and heating load of modern buildings and has an effect on humidity control. This study suggests that quantitative energy saving will be possible if the environmental control techniques of traditional buildings are appropriately applied to modern buildings.

제어 방식에 따른 지열 히트펌프 시스템의 성능 시뮬레이션 (Performance Simulation of Geothermal Heat Pump (GHP) System with Different Control Schemes)

  • 이두영;최재호;민경천;손병후
    • 대한기계학회논문집 C: 기술과 교육
    • /
    • 제4권1호
    • /
    • pp.35-41
    • /
    • 2016
  • 지열 히트펌프 시스템에서 히트펌프 등 시스템 구성 요소의 에너지 소비량을 효율적으로 관리하면, 냉난방 성능을 더 높일 수 있다. 본 논문은 외기온도 제어 방식이 지열 시스템의 성능에 미치는 영향을 분석하였다. 또한 분석 결과를 현재 국내에서 주로 적용하는 제어 방식(Control-A)과 비교하였다. 이를 위해 상용 소프트웨어(TRNSYS 17)를 이용하여 가상 지열 시스템의 모델을 구축한 후, 시뮬레이션을 수행하였다. 외기 온도 제어 방식(Control-B)은 버퍼 탱크의 온도를 외기 온도에 따라 제어하기 때문에, 간절기 때 효과적이었다. 기존 제어 방식과 비교했을 때, 외기 온도 제어 방식은 히트펌프 전력 소비량을 7.7%(147 kWh 절감) 그리고 순환펌프 전력 소비량을 7.5%(28.1 kWh 절감) 줄일 수 있었다.

그래핀을 포함하는 폴리설폰 멤브레인의 구조 및 열 특성 (Structural and Thermal Properties of Polysulfone Membrane Including Graphene)

  • 최현명;최용진;성충현;오원태
    • 멤브레인
    • /
    • 제28권1호
    • /
    • pp.37-44
    • /
    • 2018
  • Polysulfone 수지를 사용한 그래핀 복합조성물을 제조하고, 이것들의 멤브레인에 대한 잔류응력과 열전도 특성을 분석하였다. 그래핀을 포함하는 polysulfone 멤브레인의 잔류응력분석은 Si (100) 기판에 스핀코팅으로 $10{\mu}m$ 두께의 막을 도포하여 준비한 시료를 대상으로 하였으며, 잔류응력의 측정은 온도를 승온하고 냉각하는 완전한 1주기 동안 수행하였다. 그래핀을 포함하는 polysulfone 평막을 증류수를 사용한 상전이법으로 제조하여 두께방향과 면방향으로 열전도도를 구분하여 각각 측정하였으며 평막시료의 열전도 이방성을 분석하였다. 그래핀의 구조적 특징에 의해 이를 포함하는 polysulfone 막의 잔류응력은 그래핀 함량이 증가함에 따라 점차로 완화되는 경향을 나타내었고, 열전도특성은 평막형성의 구조적 특성과 그래핀의 고유특성에 의해 두께방향과 면방향의 차이를 확인할 수 있었다.

큰느타리버섯 재배사의 구조설계용 자료 분석 (Data Analysis for Structural Design of Pleurotus Eryngii Cultivation Facilities)

  • 서원명;윤용철
    • 한국농공학회논문집
    • /
    • 제47권3호
    • /
    • pp.29-37
    • /
    • 2005
  • This study was carried out to file up structural design data for optimizing Pleurotus eryngii growing houses. Design data are including current farm status of Pleurotus eryngii growing houses in the aspect of structural configuration as well as environmental conditions to be controlled and maintained inside. A structural analysis was performed for the on-farm structures as well as some structures modified and suggested through field survey and analysis. The results are summarized as follows. According to the results of status analysis, Pleurotus eryngii growing houses were categorized as arch-roofed simple type and sandwich panel type. Though the size of Pleurotus eryngii cultivation facilities were considerably diverse, the basic dimensions of Pleurotus eryngii cultivation facilities showed relatively similar pattern: more or less of 20m of length, $6.6\~7.0m$ of width, $4.6\~5.0m$ of peak height, $1.2\~1.6m$ of bed width, and 4 layers of bed. In the aspect of spatial use of cultivation facilities, suggested models were shown to be mostly reasonable in the aspect of heating and cooling, micro-meteorological stability, land use efficiency per unit floor area, etc.. Especially, the standard models suggested so far were thought to be not efficient in its surface area and spatial volume per unit floor area as well as its uneffective structural design in the area around ceiling. In the results of structural analysis for the models suggested through this study by using those section frames to be found on farms, the panel type structures of both single span and double span were estimated to be over designed, whereas arch-roofed pipe houses were mostly found to be under-designed.

Mechanical Properties of B-Doped Ni3Al-Based Intermetallic Alloy

  • Oh, Chang-Sup;Han, Chang-Suk
    • 한국재료학회지
    • /
    • 제22권1호
    • /
    • pp.42-45
    • /
    • 2012
  • The mechanical behavior and microstructural evolution during high temperature tensile deformation of recrystallized Ni3Al polycrystals doped with boron were investigated as functions of initial grain size, tensile strain rate and temperature. In order to obtain more precise information on the deformation mechanism, tensile specimens were rapidly quenched immediately after deformation at a cooling rate of more than $2000Ks^{-1}$, and were then observed by transmission electron microscopy (TEM). Mechanical tests in the range of 923 K to 1012 K were carried out in a vacuum of less than $3{\times}10^{-4}$ Pa using an Instron-type machine with various but constant cross head speeds corresponding to the initial strain rates from $1.0{\times}10^{-4}$ to $3.1{\times}10^{-5}s^{-1}$. After heating to deformation temperature, the specimen was kept for more than 1.8 ks before testing. The following results were obtained: (1) Flow behavior was affected by initial strain size; with decreasing initial grain size, the level of a stress peak in the true stress-true strain curve decreased, the steady state region was enlarged and elongation increased. (2) On the basis of TEM observation of rapidly quenched specimens, it was confirmed that dynamic recrystallization certainly occurred on deformation of fine-grained ($3.3{\mu}m$) and intermediate-grained ($5.0{\mu}m$) specimens at an initial strain rate of $3.1{\times}10^{-5}s^{-1}$ and at 973 K. (3) There were some dislocation-free grains among the new recrystallized grains. The obtained results suggest that both dynamic recrystallization and grain boundary sliding are operative during high temperature deformation.

초미세입자 제거를 위한 나노세라믹 필터의 성능 평가 (Performance of Nano Ceramic Filter for the Removal of Ultra Fine Particles)

  • 김종원;안영철;이병권;정현재
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.751-756
    • /
    • 2009
  • In the perspective of saving energy in buildings, the high performance of insulation and air tightness for improving the heating and the cooling efficiency, has brought economically positive effects. However, these building energy saving technologies cause the lack of ventilation, which is the direct cause of increasing the indoor contaminants, and is also very harmful to the residents, because they spend over 90% of their time indoors. Therefore, the ventilation is important to keep the indoor environment clean and it can also save the energy consumption. In this study, a HEPA type nano ceramic filter is designed as a passive ventilation system to collect airborne particles and to supply fresh outdoor air. The double layer filter, which has $30{\mu}m$ in diameter at the conditions of 10wt% of concentration and 3kV/cm of the electric intensity, is produced by electrospinning. The filtration coating technology is confirmed in the solution with $SiO_2$ nano particles using polymer nano fibers. Also double layer filters are coated with $SiO_2$ nano particles and finally the porous construction materials are made by sintering in the electric furnace at $200{\sim}1400^{\circ}C$. The efficiency is measured 96.67% at the particle size of $0.31{\mu}m$, which is slightly lower than HEPA filter. However the efficiency is turned out to be sufficient.

  • PDF

R410A를 이용한 브레이징 타입 판형열교환기에서 물 측 유동방향에 따른 응축/증발 성능 평가 (An Experimental Study on Evaporation/Condensation Heat Transfer with Flow Direction in Brazed Plate Heat Exchanger using Refrigerant 410A)

  • 이성우;정영만;이재근;이동혁
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1096-1101
    • /
    • 2009
  • The plate heat exchanger(PHE) in heat pump has two flow streams of the refrigerant and water. The flow direction of the refrigerant, unlike that of water, can be changed by a 4-way valve depending on operating condition. Therefore the flow arrangement is a parallel flow for heating and a counter flow for cooling, respectively. In this study, the effects of the flow direction of the water on the heat transfer rate are investigated experimentally. The experiments are carried out for brazed plate heat exchangers under a parallel and counter flow conditions in evaporation and condensation. The experimental parameters in this study include the mass flux of the refrigerant 410A from 3 to $14\;kg/m^2s$ and the flow patterns for the pressure of PHE fixed at 0.97 and 2.46 MPa. The results show that both the heat transfer rate and frictional pressure drop across the PHE increase with the mass flux. The heat transfer rate of the refrigerant 410A for evaporation show great sensitivity to flow direction of the water. The heat transfer rate for evaporation with a counter flow are 5-30% higher than that with a parallel flow.

  • PDF

LEED인증 건축물 분석을 통한 실내공간의 친환경성 개선방안에 관한 연구 (A Study on Eco-friendly Indoor Space of Domestic Eco-certified (LEED)Building through the Cases Analysis & User's Satisfaction)

  • 나민희;한혜련
    • 한국실내디자인학회논문집
    • /
    • 제22권5호
    • /
    • pp.233-240
    • /
    • 2013
  • The building construction sector has been blamed as the main culprit of environmental contamination worldwide. So, there shall be some constructive alternatives in architectural engineering. As one of the alternatives, the LEED ("Leadership in Energy and Environmental Design") has been introduced since 1990s and has been well recognized in saving the resources and energy. "LEED" has also been introduced in Korea since 2002 but it has not put priority on the eco-friendliness of indoor space. In this study, the international and domestic green systems were analyzed and compared in order to restructure the checklist for indoor space. Using the restructured checklists, the questionnaire were sent to 180 people using 6 office buildings which passed the domestic "LEED" certification. LEED certification system put priority on the air quality and heating/cooling environment in its evaluation section and items. However, according to the results of the study, it was found that the people using the buildings were not satisfied enough with the air environment of buildings along with their other indoor environment items. This shows that even though the office buildings are designed according to the requirements of LEED, the buildings do not meet the occupier's needs. In addition, it showed that the evaluation items should be improved so that they are useful to enhance the satisfaction of the occupiers' needs. The paper could be useful in establishing standard for eco friendliness of indoor space of office buildings which pass the LEED certification as the basic data for increasing energy efficiency and working efficiency of occupiers of the buildings.

ARM 마이크로컨트롤러 기반 RTD-1000A의 구현 (The Implemention of RTD-l000A based on ARM Microcontroller)

  • 김민호;홍인식
    • 인터넷정보학회논문지
    • /
    • 제9권6호
    • /
    • pp.117-125
    • /
    • 2008
  • 유비쿼터스 응용 시스템에 대한 관심의 증대와 함께 소형화된 임베디드 컴퓨팅 시스템의 필요성은 커지고 있다. 이러한 가운데 ARM 임베디드 프로세서는 기능의 우수성과 높은 활용도로 인해 임베디드 시스템 시장에서 높은 점유율을 보여주고 있다. 본 논문에서는 ARM 마이크로컨트롤러를 이용해 RTD-1000 컨트롤러 구성과 개발을 위한 최적의 방법을 제안하였다. 기존 RTD-1000은 케이블의 단선, 단락, 파손 등의 진단이 가능한 TDR를 탑재하여 구리선을 삽입한 감지관의 누수 및 누유, 파괴 등을 원격으로 감지할 수 있는 기기이다. 실제로 시공되어 현장에서 운영되고 있는 RTD-1000은 시스템 운영에 필요한 범위에 비해 리소스 낭비가 크고 그에 따라 구축비용이 높다는 단점을 가지고 있다. 또한, 발열이 심해 별도의 냉각장치가 요구되며, 하드 디스크와 같은 보조저장장치의 사용으로 고장 발생율과 전류의 소비가 커지는 등의 문제점을 야기하였다. 본 논문에서는 도출된 문제점의 해결 방법으로 ARM 마이크로컨트롤러 기반의 RTD-1000A 임베디드 시스템을 제안하고 시뮬레이션 하였다.

  • PDF

PLC와 컴퓨터를 이용한 식물생산공장의 환경제어 (Environmental Control of Plant Production Factory Using Programmable Logic Controller and Computer)

  • 김동억;장유섭;김종구;김현환;이동현;장진택
    • 생물환경조절학회지
    • /
    • 제15권1호
    • /
    • pp.1-7
    • /
    • 2006
  • This study was conducted to develop a system and an control algorithm for control the environment of a plant factory. The greenhouse control system for environmental control was largely composed of a computer and a PLC. The screen of control program was composed of a greenhouse figure which was included machinery and equipments for greenhouse, the graph of environmental factors of inside greenhouse and the image of greenhouse. In order to reduce temperature change, the operation time of ventilation window was changed by 3 stage according to difference between a target and present temperature. When is heating, a temperature variation was shown to be $16.7{\pm}0.8^{\circ}C$. When is cooling, a temperature variation was shown to be $23.1{\pm}0.6^{\circ}C$. When is humidifing, a humidity variation was shown to be $39.3{\pm}1.6^{\circ}C$ %RH. An environmental control system and a control algorithm were proved that it was shown a good performance in a control accuracy. So a computer control system should be adapted to a control system of a greenhouse and a plant factory.