• 제목/요약/키워드: Cooling and Heating

검색결과 1,915건 처리시간 0.025초

Temperature Dependent Self-Diffusion Coefficients of Valinomycin and the Potassium-Valinomycin Complex

  • Kim, Su-Deuk;Lee, Yun-Jung;Joo, Hyun-Hye;Ahn, Sang-Doo
    • 한국자기공명학회논문지
    • /
    • 제12권1호
    • /
    • pp.51-59
    • /
    • 2008
  • Convection effect in liquids has been one of the main targets to be overcome in pulsed-field-gradient NMR measurements of self-diffusion coefficients since the temperature gradient along the sample tube generated by the heating and/or cooling process causes the effect, resulting in additional diffusion. It is known that the capillary is the most appropriate tube type for diffusion experiments at variable temperatures since the narrower tube suppresses convection effectively. For evaluating the properties of hydrogen bonding, diffusion coefficients of the $K^+$-complexed and free valinomycin in a micro tube have been determined at various temperatures. From the analysis of the obtained diffusion coefficient values, we could conclude that the intramolecular hydrogen bonding in both of the $K^+$ complexed and free valinomycin in a non-polar solvent is preserved over the observed temperature range, and the temperature dependence of hydrogen bonding is more pronounced in free valinomycin. It is also thought that there is no big change in the radius of the $K^+$-complexed as temperature is varied, and the ratio of overall radius, $r_{complex}/r_{free}$ is slightly decreased as temperature rises.

구내외 정보통신기기 제어를 위한 Linux System상에서의 UPnP프로토콜 구현 (Implementation of UPnP Protocol on the Linux System for Controlling Premises Equipment)

  • 최동진
    • 조명전기설비학회논문지
    • /
    • 제19권5호
    • /
    • pp.103-108
    • /
    • 2005
  • 본 연구에서는 UPnP(Universal Plug and Play)기술을 이용하여 사용자가 구내외의 제어 가능한 모든 디바이스 즉 조명설비, 냉난방용 보일러, 방범장치와 같은 다양한 기기들을 쉽게 제어할 수 있고, 인터넷이나 휴대폰 등을 이용하여 구내외 어디에서든지 제어할 수 있도록 하였다. 이러한 UHnP프로토콜을 각 디바이스 제조사들은 자신의 기기에 탑재하기 위해 현재 PC시장의 대부분을 차지하는 윈도우즈뿐만 아니라 Linux와 같은 유연한 OS(Operating System)로의 포팅이 필요하다. 그러므로 모든 사용자들이 보다 표준화되고 안정적인 기본 네트워크 위에서 자신이 원하는 기능을 제공받아 사용하기 위하여 본 연구에서는 이러한 기능들을 Linux system에서 구현하였다.

Fe-30%Mn-6% Si 합금의 형상기억효과에 미치는 Training(SIM↔γ)의 영향 (Effect of Training( SIM↔γ) on Shape Memory Effect of Fe-30%Mn-6%Si Alloy)

  • 한상호;전중환;최종술
    • 열처리공학회지
    • /
    • 제7권2호
    • /
    • pp.118-128
    • /
    • 1994
  • Five alloys were selected randomly in the composition range showing the best shape memory effect in Fe-Mn-Si system reported by Murakami. The shape memory effects of those alloys were mainly investigated through the training treatment which consisted of the repetition of 2% tensile deformation at room temperature and subsequent annealing at $600^{\circ}C$ above $A_r$ temperature. At the same deformation degress in rolling $600^{\circ}C$-annealing for 1 hr. showed the best shape memory effect, and 10%-deformation degrees represented maxima of the shpae memory effects at all annealing temperatures, $500^{\circ}C$, $600^{\circ}C$ and $700^{\circ}C$. The shape memory effects of the alloys were increased by increasing training cycle up to 5 cycles. This was because a large number of dislocations introduced by training process gave rise to increase in the austenite yield stress, and acted as nucleation sites for stress induced ${\varepsilon}$ martensite. The thermal cycling treatment, repetition of cooling in nitrogen at $-196{\circ}C$ and heating to $300^{\circ}C$ for 5 min., did not improve the shape memory effect.

  • PDF

The study of the calculation of energy consumption load for heating and cooling in building using the Laplace Transform solution

  • Han, Kyu-Il
    • 수산해양기술연구
    • /
    • 제50권3호
    • /
    • pp.292-300
    • /
    • 2014
  • The Laplace Transform solution is used as a mathematical model to analyse the thermal performance of the building constructed using different wall materials. The solution obtained from Laplace Transform is an analytical solution of an one dimensional, linear, partial differential equation for wall temperature profiles and room air temperatures. The main purpose of the study is showing the detail of obtaining solution process of the Laplace Transform. This study is conducted using weather data from two different locations in Korea: Seoul, Busan for both winter and summer conditions. A comparison is made for the cases of an on-off controller and a proportional controller. The weather data are processed to yield hourly average monthly values. Energy consumption load is well calculated from the solution. The result shows that there is an effect of mass on the thermal performance of heavily constructed house in mild weather conditions such as Busan. Building using proportional control experience a higher comfort level in a comparison of building using on-off control.

Numerical simulations of mountain winds in an alpine valley

  • Cantelli, Antonio;Monti, Paolo;Leuzzi, Giovanni;Valerio, Giulia;Pilotti, Marco
    • Wind and Structures
    • /
    • 제24권6호
    • /
    • pp.565-578
    • /
    • 2017
  • The meteorological model WRF is used to investigate the wind circulation in Valle Camonica, Italy, an alpine valley that includes a large subalpine lake. The aim was to obtain the information necessary to evaluate the wind potential of this area and, from a methodological point of view, to suggest how numerical modeling can be used to locate the most interesting spots for wind exploitation. Two simulations are carried out in order to analyze typical scenarios occurring in the valley. In the first one, the diurnal cycle of thermally-induced winds generated by the heating-cooling of the mountain range encircling the valley is analyzed. The results show that the mountain slopes strongly affect the low-level winds during both daytime and nighttime, and that the correct setting of the lake temperature improves the quality of the meteorological fields provided by WRF significantly. The second simulation deals with an event of strong downslope winds caused by the passage of a cold front. Comparisons between simulated and measured wind speed, direction and air temperature are also shown.

자연형 태양 챔버 시스템의 계절별 성능 및 크기 결정 방법 (Sizing Method and Seasonal Performance of Passive Solar Chamber System)

  • 장향인;김병구;서승직
    • 한국태양에너지학회 논문집
    • /
    • 제31권4호
    • /
    • pp.66-71
    • /
    • 2011
  • This study focused on the application of the Passive Solar Chamber System (PSCS) as proposed by a previous study. The seasonal performance and sizing method for the system were investigated for a feasibility of the PSCS in Korean climate. For seasonal performance, heat and ventilation performances of the PSCS were analyzed for the months of January and August. This study proposed a simple configuration method in which the designer can decide on the system size at the preliminary design stage by using system efficiency, overall heat transfer coefficient transmission, monthly solar radiation, highest and lowest temperatures. During weeks that require heating, the system showed to acquire a daily average heat amount of $860.28Wh/m^2$ day. For cooling periods, the system was computed to supply a daily average natural ventilation of $1,360.2m^3/day$ to the room. Moreover, proposed sizing method and the overall computation results showed a 6.04~7.24% error of assessment.

수평형 지열교환기 성능의 경년변화 (An Experimental Study on the Thermal Performance Change of Horizontal-type Geothermal Heat Exchanger with Long-Term Operation)

  • 황광일;우상우;김중헌;양기영;신승호
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.725-730
    • /
    • 2006
  • The purpose of this study is on the performance evaluation of horizontally installed GHEX(Geothermal Heat Exchanger, HGHEX) which has been operated for 5 years successfully. Followings are the results. Firstly, in summer season, on Aug. 2000, $33^{\circ}C$ water was flowing out from HGHEX with continuous operating method, and $27{\sim}29^{\circ}C$ with interval operating method on Jul. 2005. But $2.5{\sim}3.0^{\circ}C$ temperature differences are gained from HGHEX. Secondly, in winter season, on Nov. 2000, $25^{\circ}C$ water was flowing out from HGHEX with continuous operating method, and $13{\sim}15^{\circ}C$ with interval operating method on Jan. 2006. But with each operating method, only $0.1^{\circ}C$ and $0.7^{\circ}C$ temperature differences are gained from HGHEX respectively. As the conclusion of this study, at the point of continuos operating method, seasonal balance of heating and cooling loads, and at the point of interval operating method, balance for geothermal restoring time respectively must be considered for better system performances.

  • PDF

지하수정호와 결합한 복합지열시스템의 열교환 효율에 대한 실험적 연구 (Experimental Study on Heat Exchange Efficiency of Combined Well & Open-Closed Loops Geothermal System)

  • 송재용;이근춘;박남서
    • 대한건축학회논문집:구조계
    • /
    • 제34권5호
    • /
    • pp.43-50
    • /
    • 2018
  • The temperature of underground water generally remains constant regardless of the season. therefore, it is possible to get plenty of energy if we use characteristics of underground water for both cooling and heating. This study evaluates efficiency of real size coaxial and U-tube type complex geothermal system which is combined with underground water well. This study also evaluates relative efficiency/adaptability through comparison with existing geothermal systems(vertical closed loop system, open loop system(SCW)). The heat exchange capacity of complex geothermal system according to temperature difference between circulating water and underground water shows very high significance by increasing proportionally. The temperature change of underground water according to injection energy, shows very high linear growth aspect as injection thermal volume heightens. As a result of evaluation of heat exchange volume between complex geothermal system and comparative geothermal system, coaxial type has 26.1 times greater efficiency than comparative vertical closed type and 2.8 times greater efficiency than SCW type. U-tube type has 26.5 tims greater efficiency than comparative vertical closed type and 2.8 times greater than SCW type as well. This means complex geothermal system has extremely outstanding performance.

하이브리드 센터필러 제조 시 열처리 이력이 7075 알루미늄 합금 판재의 인장강도에 미치는 영향 (Effect of Heat Treatment History in Fabrication of Hybrid Center Pillar on Tensile Strength of 7075 Aluminum Alloy Sheet)

  • 유동훈;김지훈;박상언;장홍규;김대용
    • 소성∙가공
    • /
    • 제30권2호
    • /
    • pp.61-68
    • /
    • 2021
  • As part of efforts to reduce the weight of automotive body-in-white, a hybrid center pillar with high strength 7075 aluminum alloy (AA7075) sheet and carbon fiber reinforced plastic (CFRP) has been recently studied. In the fabrication of the AA7075-CFRP hybrid center pillar, the AA7075 sheet might go through heating-forming-in-die quenching (HFQ), artificial aging, hybridizing, and then paint baking processes. In this study, we investigate the effects of the heat treatment history associated with each process on the tensile strength of the AA7075 sheet. Typical heat treatment conditions are HFQ for 20 minutes at 480℃ and then cooling down with die, artificial aging of T6 temper for 24 hours at 120℃, hybridizing for 10 minutes at 150℃, and paint baking for 20 minutes at 180℃. The tensile strength of the AA7075 sheet is continuously increased by a series of heat treatments of hybridizing and paint baking and is expected to have yield stress above 500MPa without artificial aging of T6 temper.

지열원 히트펌프 유닛 인증 현황 및 성능 분석에 관한 연구 (A Study on the Certified Ground Source Heat Pump and Performance Analysis)

  • 양찬우;강희정;최종민
    • 한국지열·수열에너지학회논문집
    • /
    • 제18권4호
    • /
    • pp.22-32
    • /
    • 2022
  • To reduce energy consumption and CO2 emission in building sector, a ground source heat pump system has been highly adopted due to its high efficient by many regulation. A certification system has been operated to distribute reliable and high-efficient heat pump units. In this study, the performance status of the recently certified ground source heat pump unit with components was investigated. All heat pump units certified from 2015 to 2020 were water to water heat pump types. Compared to the past, higher capacity systems over 400 kW have been certificed. The cooling COP of the heat pump unit based on certification criteria showed higher value than the heating COP. It is highly recommended to revise the certified criteria values considering operating conditions individually. Most of ground source heat pump units have employed scroll type compressors and plate type heat exchangers with HFC refrigerant.