• Title/Summary/Keyword: Cooling Time

Search Result 1,641, Processing Time 0.044 seconds

Fabrication and Testing of Injection Mold for Cosmetic Container with Conformal Cooling Channels Using Vacuum Diffusion Bonding (진공확산접합을 이용한 형상적응형 냉각채널을 가진 화장품 용기용 사출금형의 제작 및 시험사출)

  • Yu, Man-Jun;Park, Jong-Cheon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.3
    • /
    • pp.92-98
    • /
    • 2020
  • In this study, an injection mold with conformal cooling channels was designed and manufactured for use in the production of a thick plastic cosmetic container that required high gloss surfaces. A cooling analysis verified the design of the conformal cooling channel for the cosmetic container, and also showed that the cooling efficiency was superior to that of the straight cooling channel. Slide cores designed with the conformal cooling channel were manufactured using the Layers Parting method and vacuum diffusion bonding. Subsequent test injection and quality inspection showed no problem in the appearance and dimensional accuracy of the produced product. The cycle time for product production was about 110 seconds, sufficient for mass production.

Cooling Characteristics of a Hot Steel Plate by a Circular Impinging Liquid Jet (원형수직 충돌 수분류에 의한 고온강판의 냉각특성 연구)

  • 오승묵;이상준
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.6
    • /
    • pp.1150-1155
    • /
    • 1992
  • The cooling characteristics of a hot steel plate by a laminar impinging water bar were investigated experimentally. The dynamic parameters investigated were nozzle height L between nozzle and the hot plate, flow rate Q, and initial cooling temperature. Because the boiling phenomena on a hot steel plate are unsteady and change discontinuously, it is difficult to analyze the cooling characteristics directly. In this study the cooling efficiency was estimated by using the temperature decay rates and expansion speed of the water cooling zone. Temperature in the water cooling zone decreased rapidly and the radius of the water cooling zone expanded nearly in proportion to square root of the cooling time. With increasing initial temperature of a hot steel plate, the cooling efficiency became descendent. The cooling curve in the case of L/D = 30 showed the largest temperature decay rate and excellent cooling performance.

Analysis of Urban Warming Phenomenon using Degree days in Major Korean Cities (냉난방도일을 이용한 우리나라 주요도시의 도시승온화현상 특성분석)

  • Kim, Hae Dong;Park, Myeong Hui;Song, Gyeong Suk
    • Journal of Environmental Science International
    • /
    • v.13 no.3
    • /
    • pp.189-196
    • /
    • 2004
  • Characteristics of urban wanning phenomenon were studied using degree days for three big cities(Seoul, Busan, Daegu) adjacent to airport. Time variation of the cooling and heating degree days was analyzed using the daily mean air temperature data measured at the six meteorological observatory for long-term periods(25~43years). The results for the big cities are as followings: 1) It was found that the heating degree days trended to decrease from year to year. 2) The cooling degree days were nearly unchanged during the same analysis periods. 3) The number of days calling for air-heating also tended to decrease as time passes. 4) Those of air-cooling were nearly unchanged during the same time. It suggests that the change of air-heating condition owing to urbanization came in evidence in the winter season, but that of air-cooling condition was slight in the summer season. On the other hand, the long-term trends of degree days were very small in airport areas except for Kimhae airport. Hence, the gaps of degree days between big cities and rural airport areas are increasing.

Study on the Performance Optimization of Commercial Metal Hydride Refrigerator Powered by Exhaust Gas from Micro Gas Turbine (마이크로가스터빈의 부하에 따른 상용 수소흡장냉동기의 성능 최적화에 관한 연구)

  • Kim Hyoungsik;Sohn Wha-seung;Choi Kyoung-shik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.9
    • /
    • pp.824-829
    • /
    • 2005
  • MHR(Metal Hydride Refrigerator) powered by MGT exhaust gas is investigated to find out the optimum conditions corresponding to MGT operating powers. There are many factors to affect cooling capacity of MHR. In this study, the effect of switching time, flow rate of brine on cooling temperature and capacity is investigated. The present results show (1) hydrogen reaction is saturated with 25 min switching time at 25 kW MGT power, (2) cooling power shows maximum phenomenon with increasing switching time, (3) optimum switching times are 20 minutes for 15kW MGT power and 15 minutes for 20, 25kW MGT power, (4) according to increasing brine flow rate, cooling capacity shows decrease at 15 kW MGT power and changes little at above 20 kW MGT power.

Estimation of Hydrogen Filling Time Using a Dynamic Modeling (동적 모델링에 의한 수소 충전 시에 걸리는 시간의 산출)

  • NOH, SANGGYUN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.32 no.3
    • /
    • pp.189-195
    • /
    • 2021
  • A compressed hydrogen tank is to be repressurized to 40 bar by being connected to a high-pressure line containing hydrogen at 50 bar and 25℃. Hydrogen filling time and the corresponding hydrogen temperature has been estimated when the filling process stopped according to several thermodynamic models. During the process of cooling the hydrogen tank, hydrogen temperature and pressure vs. time estimation was performed using Aspen Dynamics. Filling time, hydrogen temperature after filling hydrogen gas, cooling time and the final tank pressure after tank filling process have been completed according to the thermodynamic models are almost same.

Effects of performance analysis of a desiccant cooling system with a direct evaporative cooler in the regeneration process (재생 입구 직접증발냉각기 적용이 제습냉방시스템 성능에 미치는 영향)

  • Dash, Ulziiutas;Oh, Myung-Do
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.633-638
    • /
    • 2009
  • In this study the performance analysis and cooling capacity of desiccant cooling system incorporating regenerative cooler and direct evaporative cooler in the regeneration air inlet were investigated on the condition of low regeneration temperature and time rotation 180s and area ratio of regeneration to dehumidification section 0.7. The cooling capacity and COP are evaluated at various effectiveness values of the direct evaporative cooler or the regenerative evaporative cooler. As either of effectiveness of the regenerative and direct evaporative coolers of desiccant cooling system increases, both the cooling capacity and COP increase, but effectiveness value of regenerative cooler gives the opposite effect on the system performance. It is found that effectiveness of regenerative cooler less than 0.7 shows the optimum cooling capacity.

  • PDF

A Study on automatic optimization of cooling circuit design in injection mold (사출금형 냉각회로의 최적설계자동화에 관한 연구)

  • Chang, H.K.;Jung, H.W.;Lee, Y.J.;Rhee, B.O.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2007.10a
    • /
    • pp.262-265
    • /
    • 2007
  • Cooling circuit of injection mold affects part quality and cycle time of injection molding process. Examination on mold cooling circuit is usually omitted in part design stage because cooling circuit is designed in the mold design stage. It is desirable to examine mold cooling circuit with respect to part quality in the part design stage. In order to make the examination process convenient and fast, cooling circuit design should be automated without intervention of skilled designer. In this study, optimization of cooling circuit design is automated with commercial softwares; Visual DOC and Moldflow MPI. Effect of initial value for optimization is examined for the optimization result.

  • PDF

Heat calculation in the slotted cooling liner (슬롯형 냉각라이너에서의 열해석)

  • Jeong, Hae-Seung;Hwang, Ki-Young;Yoon, Hyun-Gull
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.642-647
    • /
    • 2010
  • Film cooling is used to protect thermally the inner wall of combustion chamber exposed to hot gas in air-breathing propulsion system and specially film cooling using slotted cooling liner has been investigated to improve the cooling characteristics for a long time. In this paper results from gas dynamic and heat transfer calculations were presented in the combustion area and cooling area of multi-slotted cooling liner.

  • PDF

A Study on Daily Cooling Load Forecast Using Fuzzy Logic (퍼지 논리를 이용한 일일 냉방부하 예측에 관한 연구)

  • 신관우;이윤섭
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.11
    • /
    • pp.948-953
    • /
    • 2002
  • The electric power load during the peak time in summer is strongly affected by cooling load, which decreases the preparation ratio of electricity and brings about the failure in the supply of electricity in the electric power system. The ice-storage system and heat pump system are possible solutions to settle this problem. In this study. the method of estimating temperature and humidity to forecast the cooling load of ice-storage system is suggested, then the method of forecasting the cooling load using fuzzy logic is suggested by simulating that the cooling load is calculated using actual temperature and humidity. The forecast of the temperature, humidity and cooling load are simulated, and it is shown that the forecasted data approach to the actual data. Operating the ice-storage system by the forecast of cooling load with night electric power will improve the ice-storage system efficiency and reduce the peak electric power load during the summer season as a result.

Cooling Method of the Actuating Motor Using Heat Pipe (히트파이프를 이용한 구동모터에 대한 냉각기술에 관한 연구)

  • Noh, Sang-Hyun;Lee, Dong-Ryul
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1168-1173
    • /
    • 2006
  • This research is to verify the cooling effect of the acting surface on the rotary motor using heat pipe and conventional cooling fan. In order to show the cooling performance of the rotary motor and heat pipe with the fin-typed heat sink, the surface temperature of the motor and condenser was measured in real time. The experiments were also conducted as for not only cooling device installed with heat pipe only, but with heat pipe and conventional cooling fan simultaneously.

  • PDF