• Title/Summary/Keyword: Cooling Time

Search Result 1,642, Processing Time 0.029 seconds

Hardness and microstructural changes by cooling rate and holding time during porcelain firing of a multi-purpose dental gold alloy (다목적용 치과용 금합금의 소성 시 냉각속도와 계류시간에 따른 경도와 미세구조의 변화)

  • Cho, Mi-Hyang
    • Journal of Technologic Dentistry
    • /
    • v.33 no.4
    • /
    • pp.271-281
    • /
    • 2011
  • Purpose: The aim of this study is to investigate the changes in hardness and microstructure of a dental multipurpose alloy after simulated complete firing with controlled cooling rate and holding time by characterizing the changes in hardness and microstructure after simulated firing with various cooling rates and holding times. Methods: Before hardness testing, the specimens were solution treated and then were rapidly quenched into ice brine. The specimens were completely fired in furnace. Hardness measurements were made using a Vickers microhardness tester. The specimens were examined at 15 kV using a field emission scanning electron microscope. Results: The maximum hardness value was obtained at stage 0 after simulated firing with various cooling rates (quick cooling, stage 0, stage 1, stage 2, stage 3). By the repetitive firing, the hardness of the tested alloy decreased gradually. By holding the specimen at $500^{\circ}C$ for 10-20min after simulated firing, the hardness increased apparently. However, to hold the alloy for long periods of time in the relatively high temperature after simulated firing resulted in the formation of thick oxidation layer. The oxide film formed on the surface of the alloy after simulated complete firing with controlled cooling rate, which was mainly composed of O and Zn. Conclusion: It is reasonable to hold the alloy at $500^{\circ}C$ for 10-20min after complete firing in other to improve the final hardness of the alloy.

The Effect on the Heating and Cooling Load of Building by Slat Angle Variation of Venetian Blind (베네치안 블라인드의 슬래트 각도변화가 건물의 냉난방 부하에 미치는 영향)

  • Cho, S.H.;Shin, K.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.2
    • /
    • pp.171-183
    • /
    • 1995
  • Generally, among many kinds of shading devices such as venetian blind, sunscreen, louver and curtain, venetian blind is using widely because the mechanism is so simple and easy to use solar insolation by controlling the slat angle. Analysis of time dependent heat transfer through the window with venetian blind is very important in order to use it effectivly. Therefore, in this study, theoretical thermal analysis method was developed to analyze time dependent heat transfer through a double pane window with and without venetian blind, and was made one module of TRNSYS(A Transient Simulation Program)program. By this way, it was analyzed that how much the variation of slat angle, slat colour and slat absorptivity of venetian blind would be affected on the heating and cooling load of building, and also which colour and angle of slat was optimal for the heating and cooling load of building.

  • PDF

레이저 절단 판재의 브레이징을 이용한 적층 사출금형

  • 조용무;김재도
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1993.04b
    • /
    • pp.323-327
    • /
    • 1993
  • Mold-making industry demands currently to reduce the tooling costs and time in mold making, and to improve the productivity and quality in injection molding process. These problems can be easily removed by laminated injection mold which is made with metal sheets prepared by laser cutting and bonded by brazing. Comparing withthe conventional mold making technology which mainly depends on the machining, this new technologyenables an arbitary design of cooling circuit without anyrestrictions of geometry. So it brings about high production rates of the injection molding processes. This paper estimate the conventional and laminated injection mold making process with a simple molding, and also the cooling efficiencyof thoes two kinds of mold with the filling and cooling analysis. The results show that the laminated injectionmold has much shorter tooling time, uniform mold temperature, and shorter cooling time in injection molding process.

Evaporation Cooling of Single Droplet on a Heated Solid Surface (가열된 고체표면에 부착된 단일 액적의 증발냉각)

  • Yu, Gap-Jong;Bang, Chang-Hun;Kim, Jeong-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.6
    • /
    • pp.845-852
    • /
    • 2001
  • The characteristics of evaporation cooling of single droplet on a heated surface were studied experimentally. The two kinds of heater modules were tested to measure cooling characteristics of metal surface (high conductivity) and Teflon surface (low-energy surface, low conductivity). The results showed that time averaged heat flux during droplet evaporation increased exponentially with initial surface temperatures of brass, copper and steel. The heat flux and evaporation time did not varied with metal conductivities. However, the temperature drop after the deposition of droplet was larger on Teflon than on the metals. Thus, the correlation of interface temperature between liquid droplet and metal surface was proposed as a function of the initial surface temperature of heating materials, which could be applied to both metal and non-metal ones.

Change of Secondary Dendrite Arm Spacing of Hypoeutectic Al-Si Alloys according to Si Content and Cooling Rate (아공정 Al-Si 합금에서 Si 함량과 냉각속도에 따른 제이차수지상간격의 변화)

  • Park, Kyeong-Seob;Kim, Hee-Soo
    • Journal of Korea Foundry Society
    • /
    • v.37 no.4
    • /
    • pp.108-114
    • /
    • 2017
  • In this study, we investigated the effect of the Si content on the secondary dendrite arm spacing (SDAS) of hypoeutectic Al-Si binary alloys in the range of 4~10 wt% Si. Cooling curves were measured during the solidification of the alloy cast in a step-wise mold. We compared two kinds of solidification time: the first is the total solidification time for both dendritic and eutectic growth, and the second is the solidification time for only dendritic growth. The proportional constant in the relationship between SDAS and cooling rate was estimated, as this constant represents the stability of the cast microstructure. The proportional constant decreased with the Si contents from 4 wt% to 8 wt%, and it remains relatively uniform with up to 10 wt% of Si.

Experimental Study on Boiling Heat Transfer of PF-5052 in Spray Cooling (PF-5052의 분무냉각 비등열전달에 관한 실험적 연구)

  • Kim, Yeung-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.12
    • /
    • pp.938-944
    • /
    • 2008
  • The boiling heat transfer was experimentally investigated for the PF-5052 sprays impacting a square heated test surface in a downward direction. Full cone spray nozzles were employed for the spray cooling experiment, and experiments were made under the test conditions of Q=$3.32{\time}10^{-6}{\sim}\;12.98{\time}10^{-6}m^3/s$, ${\Delta}T_{sub}=5{\sim}25^{\circ}C$. Also, heat transfer measurements were made using the copper block of $10{\time}10mm^2$ test area heated by nine cartridge heater. From the experimental results, correlation between the Nusselt number and Reynolds number based on droplet-flow-rate was developed. The correlation shows good predictions with ${\pm}30$ % error for PF-5052.

Development of rapid mold heating & cooling technology to remove weldline on surface appearance in telephone case (전화기 케이스 외관의 Weldline 제거를 위한 금형 급속 가열-냉각 기술 개발)

  • Cha, B.S.;Park, H.P.;Lee, S.Y.;Kim, O.R.;Lee, S.W.;Rhee, B.O.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.10a
    • /
    • pp.439-443
    • /
    • 2008
  • Painting process or coating with acrylic film may improve the surface defects of injection molded parts deteriorated by weldlines. flow marks. and etc. However such processes increase the production costs and increase environmental problems. Recently various types of rapid mold heating & cooling technology have been developed in order to improve surface quality of products. In this study. the heating & cooling performance of a telephone case mold is investigated by heat transfer analysis, in which the rapid mold heating & reeling technology is applied. The surface temperature of the mold was measured using thermal image camera and compared with analysis results. The influence of the rapid mold heating & cooling technology on weldline appearance and cycle time increase was also examined.

  • PDF

A study on the development of injection mould with a high productivity using hybrid rapid manufacturing technologies (Hybrid 쾌속생산공정을 이용한 고생산성 사출성형 금형 개발에 관한 연구)

  • Ahn, Dong-Gyu
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1243-1248
    • /
    • 2007
  • In recent, rapid manufacturing (RM) technology is widely used to develop an injection mould with a high performance. The objective of this paper is to develop the injection mould with a high productivity using a hybrid RM technology combining Laser-aided Direct Metal Tooling process with a machining process. The geometry decomposition has been utilized to improve the speed of the manufacturing for the mould. Mould with conformal cooling channels has been designed to improve cooling characteristics. Several experiments have been carried out to evaluate characteristics of the mould manufactured from the hybrid RM technology. In addition, injection molding tests have been performed to examine the performance of the manufactured mould. The results of the injection molding tests have been shown that a cooling time and the injection time of the designed mould are reduced to one-fifth and one-second that of the mould with convention cooling channels.

  • PDF

A Study of a Conduction Cooling System of a HTS SMES System (고온초전도체 SMES 장치의 전도냉각시스템 연구)

  • Koh, Deuk-Yong;Lee, Kwan-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.4
    • /
    • pp.328-332
    • /
    • 2007
  • A superconducting magnetic energy storage (SMES) system has shorter response time and longer life time, and is more economical, and environment-friendly than other uninterruptible power supply (UPS). A conduction cooling system is well answer for the high temperature superconductor (HTS) SMES system. Because the conduction cooling system is simple, light and small structure. The purpose of this paper is to design and verify the effective conduction cooling system for the HTS SMES system. The analysis of heat loads in cryostat is performed. Thermal shield heat loads, temperatures of HTS coil surface and conduction Cu plate are estimated and measured.

Performance Analysis of Heat Pump System for Greenhouse Cooling (온실 냉방을 위한 히트펌프의 성능 분석)

  • 윤용철;서원명;이석건
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.43 no.6
    • /
    • pp.120-126
    • /
    • 2001
  • This experiment was carried out to analyse on the cooling and dehumidifying effects of greenhouse by air-to-water heat pump system employing the air as cooling source. following results were obtained ; 1. The coefficients of performance (COP) of heat pump itself and total heat pump system were approximately 2.71~2.88 and 1.99~2.22, respectively. 2. The night-time cooling load of experimental greenhouse was 64.9 MJ/h, and the heat absorbed (cooling load) from heat pump system was 816.3~1,004.6 MJ/day. 3. The dehumidified moisture amount from experimental greenhouse was 7.0~15.0 kg/h. 4. The night time temperature of experimental greenhouse cooled by heat pump system could be maintained 4~6$^{\circ}C$ lower than that of control greenhouse which was almost equal to outside air temperature.

  • PDF