• Title/Summary/Keyword: Cooling Passage

Search Result 125, Processing Time 0.022 seconds

Design and Analysis of Two-Directional Regenerative Cooling Passages for Liquid Rocket Nozzle (액체로켓연소실의 양 방향 재생냉각유로 설계/해석)

  • Kim, Seong-Ku;Kim, Jong-Gyu;Han, Yeoung-Min;Choi, Hwan-Seok
    • Aerospace Engineering and Technology
    • /
    • v.7 no.1
    • /
    • pp.129-135
    • /
    • 2008
  • The 30 tonf-class liquid rocket combustor currently being developed is designed to connect the fuel feeding line at a middle position of the supersonic nozzle in order to reduce both pressure loss in the regenerative cooling passage and overall envelope of the thrust chamber in spite of increase in design complexity. To verify the design of cooling passages including fuel ring, connecting holes, two-directional cooling channels and collectors, numerical analysis has been performed.

  • PDF

A Combined Effect of Differential Cooling and Topography on the Formation of Ulleung Warm Eddy

  • SEUNG Young Ho;NAM Soo Yong;LEE Sang Yong
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.22 no.6
    • /
    • pp.375-384
    • /
    • 1990
  • A numerical experiment is made to study the combined effect of differential cooling and bottom topography on the formation of Ulleung Warm Eddy. The Ulleung Warm Eddy appears after the passage around the Ulleung Basin of coastal trapped baroclinic waves generated in the north initial density front to the north, the continental slopes both to the west and south, and the Yamato Rise to the east. It resides therefore always inside the Ulleung Basin, as confirmed by observations.

  • PDF

An Experimental Study on the Operating Characteristics with HVAC Type of Shopping Center in Underground Passage (지하도상가의 HVAC 구성방식에 따른 운전특성 연구)

  • Lee, Hong-Cheol;Hwang, In-Ju
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.76-81
    • /
    • 2007
  • The shopping center in underground passage increased for efficient space utilization in urban area. This study describes operation characteristics of all air type and hybrid type with local ventilation and fan coil unit fixed to ceiling. In order to compare energy saving, thermal environment and installation space, etc., integrated simulator with heat production and indoor distribution system is designed and constructed. Energy saving of the hybrid system is calculated as over 30% compared to conventional all air type. And also the results showed that humidity decreased about 6%, also indoor thermal distribution is improved as temperature variation of around $1^{\circ}C$.

  • PDF

Typhoon Simulation with a Parameterized Sea Surface Cooling (모수화된 해면 냉각을 활용한 태풍 모의 실험)

  • Lee, Duho;Kwon, H. Joe;Won, Seong-Hee;Park, Seon Ki
    • Atmosphere
    • /
    • v.16 no.2
    • /
    • pp.97-110
    • /
    • 2006
  • This study investigates the response of a typhoon model to the change of the sea surface temperature (SST) throughout the model integration. The SST change is parameterized as a formulae of which the magnitude is given as a function of not only the intensity and the size but the moving speed of tropical cyclone. The formulae is constructed by referring to many previous observational and numerical studies on the SST cooling with the passage of tropical cyclones. Since the parameterized cooling formulae is based on the mathematical expression, the resemblance between the prescribed SST cooling and the observed one during the period of the numerical experiment is not complete nor satisfactory. The agreements between the prescribed and the observed SST even over the swath of the typhoon passage differ from case to case. Numerical experiments are undertaken with and without prescribing the SST cooling. The results with the SST cooling do not show clear evidence in improving the track prediction compared to those of the without-experiments. SST cooling in the model shows its swath along the incomplete simulated track so that the magnitude and the distribution of the sea surface cooling does not resemble completely with the observed one. However, we have observed a little improvement in the intensity prediction in terms of the central pressure of the tropical cyclone in some cases. In case where the model without the SST treatment is not able to yield a correct prediction of the filling of the tropical cyclone especially in the decaying stage, the pulling effect given by the SST cooling alleviates the over-deepening of the model so that the central pressure approaches toward the observed value. However, the opposite case when the SST treatment makes the prediction worse may also be possible. In general when the sea surface temperature is reduced, the amount of the sensible and the latent heat from the ocean surface become also reduced, which results in the weakening of the storms comparing to the constant SST case. It turns out to be the case also in our experiments. The weakening is realized in the central pressure, maximum wind, horizontal temperature gradient, etc.

Predictions of the Cooling Performance on an Air-Cooled EV Battery System According to the Air Flow Passage Shape (공기 유로 형상에 따른 공랭식 전기자동차 배터리 시스템의 냉각 성능 예측)

  • Jeong, Seok Hoon;Suh, Hyun Kyu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.12
    • /
    • pp.801-807
    • /
    • 2016
  • This paper aims to compare and study the cooling performance of a battery system in accordance with the inlet and outlet geometry of the air passage in an EV. The arrangement and the heat source of the battery module were fixed, and the inlet/outlet area and its geometry were varied with the analysis of the cooling performance. The results of this study provide suggestions for the air flow stream line inside of a battery, the velocity field, and the temperature distributions. It was confirmed that the volume flow rate of air should be over $400m^3/h$, in order to satisfy conditions under $50^{\circ}C$, which is the limit condition for stable operation. It was also revealed that the diffuser outlet geometry can improve the cooling performance of battery system.

A Flow Channel Design on IR Window Cooling Device (적외선 윈도우 냉각장치 유로 설계)

  • Park, Youn-Jung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.6
    • /
    • pp.559-566
    • /
    • 2011
  • This paper presents the flow passage design for a window cooling device, which have a conical poppet valve and an emissive orifice. Computational flow analysis and experiment are conducted according to the poppet strokes. The results show satisfactory flow characteristics that pressure is reduced enough to endure material strength and the flow does not choked inside window. The correction factor of discharge coefficients is found between 2-dimensional analysis and experiments, which is applied to control coolant flow rates of the window cooling device.

Abnormal Oceanic Conditions Caused by Typhoons Around the Korean Peninsula (태풍에 의해 발생하는 한국근해 해황이상변동)

  • SUH Young-Sang;GU Ji-Young;HWANG Jae-Dong;LEE Na-Kyung;KIM Bok-Kee;JANG Lee-Hyun;KANG Yong-Q;LEE Dong-In
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.36 no.4
    • /
    • pp.417-429
    • /
    • 2003
  • Abnormal oceanic conditions associated with the passage of typhoons are examined using hydrographic and satellite data 1990-2002. During the passage period of typhoons in the Korean waters, an abrupt decrease of sea surface temperature (SST) in range of 5 to $8^{\circ}C$ was observed. The areas of SST decrease were an order of 100-200 km, and the low SST lasted about 15-25 days after passage of typhoon. After passage of typhoon, the water temperatures in the surface mixed layer of 30 m show negative anomalies for quite a long period. In addition, stratification parameters were substantially decreased and chlorophyll a density was rapidly increased.

Abnormal oceanic conditions around the Korean peninsula caused by typhoons

  • Suh, Young-Sang;Gu, Ji-Young;Hwang, Jae-Dong;Lee, Na-Kyung;Jang, Lee-Hyun;Jeon, Kyoung-Ok
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.640-641
    • /
    • 2003
  • Abnormal oceanic conditions associated with the passage of typhoons are examined using hydrographic and satellite data 1990-2002. During the passage period of typhoons in the Korean waters, an abrupt decrease of sea surface temperature(SST) in range of 5 to 8 $^{\circ}$ was observed. The areas of SST decrease were an order of 100-200km, and the low SST lasted about 15-25 days after passage of typhoon. After passage of typhoon, the water temperatures in the surface mixed layer of 30m show negative anomalies for quite a long period. In addition, stratification parameters were substantially decreased and chlorophyll a density was rapidly increased.

  • PDF

Conceptual Design of Coolant Channel for Sub-scale Combustion Chamber (소형 연소기 냉각 유로 개념 설계)

  • 정용현;조원국;한상엽;류철성
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.6 no.4
    • /
    • pp.1-6
    • /
    • 2002
  • A numerical heat transfer analysis and the structural analysis were performed for the design of sub-scale combustion chamber's coolant passage. The heat flux through the combustion chamber wall was estimated by 2-D heat transfer analysis of compressible hot gas and the result was applied as a thermal boundary condition of 3-D analysis. The heat flux estimated by the present method agreed well with the experimental correlation and proved to be insensitive to cooling condition. So the same thermal boundary condition was applied for various operating conditions. The maximum temperature of combustion chamber wall was predicted by 3-D analysis for single coolant passage and the result will be used for the development of a regeneratively cooled combustion chamber. Also estimated were the stress distribution and structural safety of coolant passage through the static structural analysis.