• 제목/요약/키워드: Cooling Oil

검색결과 367건 처리시간 0.035초

건물용 연료전지 기반 하이브리드 제습냉방시스템 성능 및 에너지 절감 분석 (Analysis of Performance and Energy Saving of a SOFC-Based Hybrid Desiccant Cooling System)

  • 인정현;이율호;강상규;박성진
    • 한국수소및신에너지학회논문집
    • /
    • 제30권2호
    • /
    • pp.136-146
    • /
    • 2019
  • A solid oxide fuel cell (SOFC) based hybrid desiccant cooling system model is developed to study the effect of fuel utilization rate of the SOFC on the reduction of energy consumption and $CO_2$ emission. The SOFC-based hybrid desiccant cooling system consists of an SOFC system and a Hybrid desiccant cooling system (HDCS). The SOFC system includes a stack and balance of plant (BOP), and HDCS. The HDCS consists of desiccant rotor, indirect evaporative cooler, electric heat pump (EHP), and heat exchangers. In this study, using energy load data of a commercial office building and SOFC-based HDCS model, the amount of ton of oil equivalent (TOE) and ton of $CO_2$ ($tCO_2$) are calculated and compared with the TOE and $tCO_2$ generation of the EHP using grid electricity.

다양한 화상 응급처치의 치료효과 비교 (Comparison of Clinical Outcomes Using Various First-Aid Cooling Method for Burn)

  • 이정환;송우진;권민주;박양서;고장휴
    • 대한화상학회지
    • /
    • 제24권1호
    • /
    • pp.7-13
    • /
    • 2021
  • Purpose: Currently, the most recommended method for burn first aid is the cool running water for 20 minutes (CRW20). If CRW20 is not practicable, cooling dressing products with tea tree oil are used as substitutes. In this study, we analyze the effect of various burn first aids, including CRW20, cooling products, on the treatment period. Methods: This study was conducted on patients who suffered burns and visited Hangangsoo Hospital from March 2019 to March 2020. The study conducted in a retrospective method. The duration of treatment was analyzed by dividing the experimental group. Results: The treatment period was shortened when first aid was given (P<0.001). Cold water, ice, and ice packs resulted in reduced treatment periods (P<0.001, P=0.004). The treatment period was reduced when cooling dressing products were used in all groups (P=0.041). The implementation of first aid has reduced the duration of burn treatment. This means that cooling helps burn treatment. CRW20 did not show statistically meaningful results. This is the result of a failure to fully control the temperature and time of tap water. In addition, the change in temperature of tap water according to season, the use of water is higher than that of animal testing, and the general lack of information on proper burn first aid may have affected. Conclusion: The treatment period was statistically significantly reduced in the group that performed first aid. Among the various first aid methods, cold water and ice reduced the treatment period.

Coal Oil을 사용한 스파크 점화기관의 압축비 변화에 따른 엔진 성능에 관한 연구 (A Study on the Performance Characteristics According to the Compression Ratio of Spark Ignition Engine Fuelled with Coal Oil)

  • 한성빈;정연종
    • 한국수소및신에너지학회논문집
    • /
    • 제28권2호
    • /
    • pp.225-230
    • /
    • 2017
  • Coal oil is widely used as a home heating fuel for portable and installed coal oil heaters. Today, Coal oil is widely used as fuel for jet engines and some rocket engines in several grades. This paper describes the performance characteristics according to the compression ratio of spark ignition engine fuelled with coal oil. As a result, the following knowledge is obtained: As the compression ratio is decreased, there is an increase in torque, indicated mean effective pressure (IMEP), heat release rate, and brake thermal efficiency. Higher compression ratio of the engine decreases the ignition delay period, combustion period, and cooling loss.

친환경 식물성절연유의 유동대전현상 연구 (Research of Flow Electrification Phenomena of the used Environment-Friendly Vegetable Insulating Oils)

  • 최순호;허창수
    • 전기학회논문지
    • /
    • 제61권4호
    • /
    • pp.580-584
    • /
    • 2012
  • The insulating oils perform a cooling and insulation action in electric power transformer. The mineral oil has immanent fire dangerousness and environmental contamination problem. Vegetable insulating oil has higher ignition point, flash point and more excellent biodegradability than conventional mineral oil. In a real oil-filled transformers, some of the power is dissipated in the form of heat. And transformer require the heat to be removed from the winding and insulator by forced convection of the insulating oil. The flow electrification occurs when insulating oil was forced to be circulated. In this paper, influence of temperature, velocity of flow, and insulating pipe and diameter on streaming electrification of vegetable insulating oil was investigated using forced circulation apparatus. Temperature effects were most significant, and it showed a peak in the temperature $30^{\circ}C$ to $35^{\circ}C$ at insulating and copper pipe. The change of flow electrification according to area variety could be checked by change of diameter.

합성 폴리올에스테르류 기능성 윤활유의 제조 및 특성 (Preparation and Properties of Functional Lubricant based Synthetic Polyolesters)

  • 이재덕;정노희
    • 한국응용과학기술학회지
    • /
    • 제27권4호
    • /
    • pp.522-530
    • /
    • 2010
  • We developed functional synthetic lubricant for internal combustion engine oil, which would improve engine oil performance for internal combustion engine and extend engine life. We made base oil by synthesizing nonanoic acid, 1.1.1-trimethylol propane (which has good bio-degradability) and pentaerythrytol ester. We synthesized catalyst using p-toluene sulfonic acid 0.15 wt% and coloring-prevention agent hypo-phosphorus acid 0.18 wt% at 180-$190^{\circ}C$. Reaction temperature was increased at the rate of $10^{\circ}C$ for every 1 hour. When acid value reached below 3, reaction was completed. After cooling and deoxidization, we washed it by distilled water two times. After dehydration and filtering, we obtained trimethylol propane tripelargonate (TMTP) and pentaerythrytol tetrapelargonate (PETP) at yields of 96 % and 98 % respectively.

고효율 나노절연유 제조 및 변압기에의 적용 (Preparation of High-Efficient Oil-based Nanofluids and It's Application to the Transformer)

  • 유현성;최철;오제명
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.31-32
    • /
    • 2007
  • Oil-based nanofluids are prepared by dispersing spherical and fiber-shaped $Al_2O_3$ and AlN nanoparticles in transformer oil. Two hydrophobic surface modification processes are compared in this investigation. It is obvious that the combination of nanoparticle, surfactant and surface modification process is very important for the dispersity of nanofluids. For ($Al_2O_3$+AIN) particles with 1% volume fraction, the enhancement of thermal conductivity and convective heat transfer coefficient is nearly 11% and 30%, respectively, compared to pure transformer oil. The cooling effect of ($Al_2O_3$+AlN)-oil nanofluids on the heating element and oil itself is confirmed by a natural convection test using a prototype transformer.

  • PDF

붕소도핑 다이아몬드 전극을 이용한 수용성 폐절삭유의 전기화학적 특성연구 (A Study on the Electrochemical Properties of Water-soluble Waste Cutting Oil using Boron-Doped Diamond Electrodes)

  • 박진혁;김태규
    • 열처리공학회지
    • /
    • 제35권6호
    • /
    • pp.337-342
    • /
    • 2022
  • In metal cutting, water-soluble cutting oil is used for cooling the surface of the workpiece and improving the surface roughness. However, waste cutting oil contains preservatives and surfactants, and if it is discarded as it is, it has an great influence on environmental pollution. For this reason, regulations on the use of cutting oil are being stricter. Hence, the development of eco-friendly treatment technologies is required. In this study, a diamond electrode doped with boron on a niobium substrate was deposited by thermal filament chemical vapor deposition and waste cutting oil was treated using an electrochemical method. Compared to the total amount of organic carbon contained in the waste cutting oil, it was confirmed that the boron-doped diamonds developed from this study showed much better performance than electrodes that has been widely used before.

가속열화에 따른 식물성절연유의 화학적.전기적 특성 분석 (Analysis on the Chemical and Electrical Characteristic of Vegetable oil by Accelerated Aging)

  • 최순호;정중일;허창수
    • 전기학회논문지
    • /
    • 제60권5호
    • /
    • pp.984-989
    • /
    • 2011
  • Electrical insulation is one of the most important part in a high voltage apparatus. Recently, researchers are interested in the environmental friendly vegetable oil from environmental viewpoint. Accelerated aging transformer insulating material in vegetable oil was compared to that of mineral oil. Accelerated aging oil samples produced in the oven at $140^{\circ}C$ for 500, 1000, 1500, 2000hours. And Real transformer insulation oils samples of vegetable oil and mineral oil were aged by thermal cycles repeating from $30^{\circ}C$ to $120^{\circ}C$. Samples were analyzed at 42, 63, 93, 143, 190, 240, 300 cycles. The mineral and vegetable insulating oils were investigated for breakdown voltage, water content, total acid number, viscosity, volume resistivity, insulating paper and oil permittivity, and dissolved gas analyses. The breakdown voltage of the vegetable insulating oil is higher than that found for the mineral oil; the accelerated aging progress decreased the breakdown voltage. The vegetable oil had a higher water saturation than the mineral oil; the vegetable oil has the superior water characteristics and breakdown voltage. And high viscosity of vegetable oil, care has to be taken, especially when designing the cooling system for a large transformer.

원통다관 형 오일냉각기의 최적선정 및 도면 출력 프로그램 개발 (The Optimum Selection and Drawing Output Program Development of Shell & Tube Type Oil Cooler)

  • 이용범;고재명;김태석
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2609-2614
    • /
    • 2007
  • Shell & Tube type Oil Cooler is widely used for hydraulic presses, die casting machines, generation equipments, machine tools and construction heavy machinery. Temperature of oil in the hydraulic system changes viscosity and thickness of oil film. They have a bad effect to performance and lubrication of hydraulic machinery, so it is important to know exactly the heat exchanging efficiency of oil cooler for controlling oil temperature. But most Korean manufacturers do not have test equipment for oil cooler, so they cannot carry out the efficiency test of oil cooler and it is impossible to verify its performance. This paper includes information of construction of necessary utilities for oil cooler test and design and manufacture of test equipment. One can select the optimum product by obtaining performance data through tests of various kinds of oil coolers. And also the paper developed a program which can be easily used for design of 2D and 3D drawings of oil cooler.

  • PDF

식물성 절연유와 광유가 사용된 유입변압기의 온도분포 특성 (Analysis on the Temperature Distribution Characteristics of Insulating oil of Transformer Using the Vegetable oil and Mineral oil)

  • 안정식;심명섭;정중일;김남렬;허창수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1215_1216
    • /
    • 2009
  • Most transformer use insulating and cooling fluids derived from petroleum crude oil, but mineral oil is some possibility of environmental pollution and fire with explosion. vegetable oil fluids extracted from seed has superior biodegradation and fire-resistant properties including an exceptionally high fire point enhancing fire safety. In this study, it is aimed at the practicality of substituting natural ester dielectric fluid for mineral oil in liquid insulation system of transformers. As a rise in coil winding temperature has a direct influence on transformer life time, it is important to evaluate the temperature rise of coil winding in vegetable oil in comparison with mineral oil. Three transformers for the test are designed with 10KVA, 13.2KV, one phase unit. The temperature are directly measured in insulating oil of these transformers with the two sorts of natural ester and mineral oil dielectric fluid respectively. Temperature of vegetable oil transformers was similar to temperature of mineral oil transformer in the same design at 80% load and above.

  • PDF