• Title/Summary/Keyword: Cooling Condition

Search Result 1,247, Processing Time 0.025 seconds

Effect of Post Solidification Cooling Condition on the Mechanical Behavior of the 0.36Mn Containing Ductile Iron (0.36Mn이 함유된 구상흑연주철의 냉각조건에 따른 기계적 거동 고찰)

  • Kim, Suck-Dong;Kim, Sung-Gyoo
    • Journal of Korea Foundry Society
    • /
    • v.41 no.4
    • /
    • pp.349-356
    • /
    • 2021
  • Effects of cooling condition after solidification on the microstructure and the mechanical properties of 0.36Mn containing ductile cast iron have been studied based on the minimized addition of Cu and Sn for vehicle component applications with better quality and cost competitiveness. Cu and Sn were selected for additional elements judging from the well-known fact of strong tendency of pearlite promotion followed by the tensile property improvement. After pouring of the Mg treated cast iron melt with various chemical compositions into the block specimens, two ways of post solidification cooling conditions were applied for comparison; both cooling in the mold and cooling in the air after dismantle at 800℃. The pearlite fraction of the mold-cooled specimens was analyzed as 27-44%, with the tensile strength and elongation of 513-568N/mm2 and 10.4-14.3%, respectively. Whilest, the air cooled specimens showed the pearlite fraction of 77~85%, with the tensile strength and elongation of 728~758N/mm2 and 3.2~6.0%, respectively. It is worthwhile to note that the remarkable improvement of both tensile strength and elongation of the ductile iron was achieved by the present air cooling condition with the minimized combined addition of Cu and Sn to the 0.36Mn containing ductile iron.

Numerical Study on the Three-Dimensional Natural Convection Cooling of Periodically Fully Developed PCB Channel (주기적으로 완전발달된 PCB 채널의 3차원 층류 자연대류 냉각에 관한 수치적 연구)

  • 이관수;백창인;김우승
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.10
    • /
    • pp.2751-2761
    • /
    • 1994
  • A numerical investigation on the three-dimensional laminar natural convection heat transfer in the periodically fully developed PCB channel has been performed. When heat generating blocks mounted on the adiabatic wall make a channel with their facing shrouding wall, the flow inside the channel becomes periodically fully developed. A single module in the periodically fully developed region is chosen for computational domain in order to save computer storage and computational time. The periodic boundary condition is applied in the anlaysis. The effects of the parameters such as the Rayleigh number, the number of the modules, and the height of channel are examined to obtain the optimum condition for the enhancement of the cooling effectiveness. The result shows that the cooling effect is improved with increasing Rayleigh number and channel height, and decreasing the number of the module. The result also indicates that increasing the height of the channel and number of the module is recommended for a limited space.

Flow Characteristics of a Primary Cooling System in 5 MW Research Reactor (5MW 연구용 원자로의 1차 냉각 계통 유동 특성)

  • Park, Young-Chul;Lee, Young-Sub
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.5
    • /
    • pp.5-10
    • /
    • 2010
  • 5MW, open pool type research reactor, is commonly used to education and experimental purpose. It is necessary to prepare a standardization of system designs for considering a demand. HANARO has prepared the standardization of 5MW research reactor system designs based on the design, installation, commissioning and operating experiences of HANARO. For maintaining an open pool type reactor safety, a primary cooling system (after below, PCS) should remove the heat generated by the reactor under a reactor normal operation condition and a reactor shutdown condition. For removing the heat generated by the reactor, the PCS should maintain a required coolant flow rate. For a verification of the required flow rate, a flow network analysis of the PCS was carried under a normal operating condition. Based on the flow network analysis result, this paper describes the PCS flow characteristics of a 5MW open pool type research reactor. Through the result, it was confirmed that the PCS met design requirements including design flow rate without cavitation.

Adhesion Performance of Electromagnetic Induction Heating Pixture for the Integration with a Waterproof & Root Barrier Sheet and a Roof Green Unit System (방수·방근시트와 옥상녹화 박스유닛 시스템의 일체화를 위한 전자기 유도가열 융착 고정구의 부착성능)

  • Oh, Chang-Won
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.5
    • /
    • pp.463-469
    • /
    • 2018
  • A currently used roof green system with multi layers has a low constructability. Therefore a new integrated waterproof & root barrier sheet and roof green box unit system was developed using steel plate fixture and cone type fixture by electromagnetic induction heating method. This study was proceeded to evaluate adhesion performance of two types of fixtures on Engineering PE, TPO, PVC sheet in a normal condition, repeated heating and cooling condition. As a result, adhesion load on Engineering PE sheet showed the highest value. The adhesion loads of steel plate fixture showed higher value as heating temperature was getting higher. However adhesion loads of cone type fixture showed opposite tendency. Regarding to the test conditions, test results of normal condition, repeated heating and cooling condition showed same value. The cone type fixture using butyl tape showed 7 times lower adhesion load than that of cone type fixture using electromagnetic heating and 28% lower adhesion load in a repeated heating and cooling condition than a usual condition.

Experimental Study on The Running Characteristics of Showcase Using Cold Storage System (과냉각 축냉시스템을 적용한 쇼케이스의 운전 특성에 대한 실험적 연구)

  • Lee, Dong-Won;Kim, Jeongbae
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.6
    • /
    • pp.22-28
    • /
    • 2012
  • The purpose of this study was to show how tomaintain high efficiency and to use reasonably when being applied the cold-heat storage systems to the showcase. An experimental study was performed to manufacture the showcase system in a laboratory. Comparing the result at general operation condition with that of the new condition using ice storage system, this study showed the effects of the refrigerant sub-cooling, and with using inverter. Using ice storage system, the ice making process was operated during midnight being not needed the cooling of the showcase through the continuous running of the condenser unit. And then, the refrigerant was sub-cooled using the stored cold-heat after being discharged from the air cooling condenser during the day time. Through the experiments, the load transfer rate for the showcase using inverter and ice storage was estimated about 30.0%. And showed that the total power consumption of the showcase with inverter could be reduced about 37% than that of the showcase without inverter.

Configuration and Analysis of a Feed-forward Control System for Jacket Cooling Water Temperature of Marine Prime Diesel Engine (주기관 쟈케트냉각수 온도를 위한 피드포워드 제어시스템의 구성과 분석)

  • Choi, Soon-Man
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.8
    • /
    • pp.1303-1308
    • /
    • 2008
  • Keeping cooling water temperature higher within the allowable range helps marine engines to run in more efficient condition especially when the engine load is low. Temperature control of jacket cooling water in outlet side of main engine has been more widely adopted to ships these days for the purpose to reduce fuel consumption rate. But If the temperature sensor for the control loop is placed at the outlet of engine, it brings more difficulties in attaining stable and desirable properties due to dead times included in pipe length and engine itself comparing to the case where the measuring point is at the inlet side of main engine. In relation with this problem, Feed-forward control could be one of realistic solutions as it reveals good properties and requires less cost for system configuration. This study suggests a forward control system which leads to improved temperature control performances to disturbance signals which could arise from variation of engine load or weather condition. Two dead times in the modelling were described, considering pipe length between the actuator and the engine as well as the thermal process inside the engine. The results of analysis were shown by simulations to confirm responses under different conditions.

Cycle Simulation of the Air-Conditioner Using Alternatives to R22 (R22의 대체냉매를 사용한 공기조화기의 성능 시뮬레이션)

  • Chang, S.D.;Ro, S.T.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.1
    • /
    • pp.47-53
    • /
    • 1994
  • Cycle simulation of the air-conditioner was carried out using a number of candidate alternatives to R22;R32/R125/R134a(30/10/60, by mass percent), R32/R125/R134a(10/70/20), R32/R134a(25/75), R32/R134a(30/70), R32/R125(60/40), R290(propane) and R134a. In this study, we considered only the basic parts of the air-conditioner such as the compressor, the evaporator, the condenser and the capillary tube, for the purpose of analysis. The performance characteristics of alternatives considered here were examined by comparing with the case using R22 at the constant volumetric flow rate condition. The results of our analysis revealed that the use of refrigerant mixtures, R32/R134a(30/70) and R32/R125/R134a(30/10/60), was appropriate for the alternatives to R22 in view of the cooling capacity and the COP. For the case of using R134a and R290, the COP was observed to increase under the same volumetric flow rate condition, but the cooling capacity was substantially decreased. Therefore the use of R134a and R290 should be accompanied with increasing considerably the size of compressor in order to maintain the same cooling capacity of R22.

  • PDF

Gas cooling heat transfer coefficient for $CO_2$-PEC9 mixture under supercritical condition (초임계조건에서 $CO_2$-PEC9 혼합물의 물성예측을 통한 냉각 열전달특성 연구)

  • Yun, Rin
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.821-826
    • /
    • 2009
  • Due to environmental concerns $CO_2$ has been reintroduced as a potential candidate to replace HFCs in refrigeration systems. Oils are always required in a vapor-compression cycle, and thus actual working fluid in the system is $CO_2$-oil mixtures even though the oil concentrations are low at the heat exchangers and the expansion device. The cooling heat transfer coefficients for $CO_2$-oil mixtures under supercritical condition are required to designing of the gas cooler in the $CO_2$ refrigeration system properly. In the present study, the gas cooling heat transfer coefficients for $CO_2$-PEC9 was estimated by using the Gnileinski correlation, and the Kim and Ghajar model through the previous prediction models for the thermo-physical properties of $CO_2$-oil mixture. The Gnileinski correlation was used when the oil wt.% in the mixture is less than 1.0, and for the higher oil concentration the Kim and Ghajar model was applied. The estimated results agree with the experimental results conducted by the Dang et al.

  • PDF

Effect of Two Step Austenitizing Treatment Conditions on the Microstructural Characteristics of ADI (ADI의 조직특성에 미치는 2단 오스테나이트화 처리조건의 영향)

  • Choi, S.L.;Yun, K.H.;Moon, W.J.;Kang, C.Y.;Kim, H.G.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.11 no.1
    • /
    • pp.46-53
    • /
    • 1998
  • The variation of the mechanical properties, microstructures and the formation of retained austenite with heat treatment conditions in austempered ductile cast iron has been investigated. In the case of austempered ductile cast iron below 25mm diameter, it has been found that a pearlite structure are not obtained under a super cooled condition at range of $0.05^{\circ}C/sec{\sim}10^{\circ}C/sec$, and the matrix is precipitated in graphite, bainite and retained austenite. After austempering treatment the retained austenite is increased with decreasing cooling rate. The elongation increases with decreasing super cooling rate, and the optimum result has been shown to be the elongation of 15.6% at super cooling rate of $0.05^{\circ}C/sec$. The optimum result has been shown to be the tensile strength-elongation balance of $1656kgf/mm^2.%$ and it is more than doubled to as the casting state and continuous cooling condition.

  • PDF

An Experimental Study of the Air-side Particulate Fouling of Finned-Tube Heat Exchangers of Air Conditioners by using Accelerated Particle-Loading System (파울링 형성 가속장치를 이용한 공기조화기용 열교환기의 공기측 파울링 특성에 대한 실험적 연구)

  • 안영철;조재민;이재근;이현욱;안승표;윤덕현;하삼철;강태욱;옥주호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.10
    • /
    • pp.802-808
    • /
    • 2003
  • The air-side particulate fouling of the HVAC heat exchangers degrades the performance of cooling capacity, pressure drop across a heat exchanger, and indoor air quality. The purpose of this study is to investigate the fouling characteristics using accelerated particle loading system. The fouling characteristics are analyzed as functions of a dust concentration, a face velocity and a wet or dry surface condition. The pressure drop increases with increasing test operation and reaches constant asymptotic level. For the saturated condition due to particle loading, the pressure drop across the slitted finned-tube heat exchangers at the face velocity of 1 m/sec increases up to 57% and the cooling capacity decreases about 2%. The cooling capacities are not affected greatly by the presence of the fouling deposits if the thickness of the fouling deposits can not change substantially the flow pattern through the fins.