• 제목/요약/키워드: Cooling Air

검색결과 2,710건 처리시간 0.024초

공작기계용 고속주축계의 공기냉각특성에 관한 연구 (Air Cooling Characteristics of a High Speed Spindle System for Machine Tools)

  • 최대봉;김석일;송지복
    • 한국정밀공학회지
    • /
    • 제11권1호
    • /
    • pp.123-128
    • /
    • 1994
  • A high speed spindle system for machine tools can be used to reduce the machining time, to improve the machining accuracy, to perform the machining of light metals and hard materials, and to unite the cutting and grinding processes. In this study, a high speed spindle system is developed by applying the oil-air lubrication method, angular contact ball bearings, injection nozzles with dual orifices, cooling jacket and so on. And an air cooling experiment for evaluating the performance of the spindle system is carried out. Especially, in ofder to establish the air cooling conditions related to the development of a high speed spindle system, the effects of cooling air pressure, oil supply rate, air supply rate and rotational spindle speed are studied and discussed on the bearing temperature rise and frictional torque. Also the effects of cooling air pressure, rotational spindle speed and spindle system structure is investigated on the bearing temperature distribution. The experiment on the test model reveals the usefulness of the air cooling method.

  • PDF

냉각탑 백연방지의 성능 향상에 관한 실험적 연구 (An Experimental Study on the Cooling Tower of Plume Prevention and Performance Improvements)

  • 정순영;이병천;김성
    • 한국수소및신에너지학회논문집
    • /
    • 제30권6호
    • /
    • pp.578-584
    • /
    • 2019
  • The occurrence of white plume in the cooling tower is phenomenon that the steam in the air through the cooling tower fan is condensed again by the cold ambient air to become saturated moist air. Accordingly, this can cause many problems like spoiling landscape around the cooling tower, odor of ambient air, falling accident by frozenness in the winter, and traffic accident, etc. This study was to install the heat exchanger in the inside of the cooling tower in order to prevent the white plume phenomenon in the cooling tower without affecting the performance of cooling tower. In addition, this study was to discharge the part of cooling water into the atmosphere through the recirculation of heat exchanger after creating dry air by heating the saturated moist air to the dew point temperature. At that time, this study was to conduct the experimental study in order to secure the optimal design data to prevent the white plume in the cooling tower because it checked the dry·moist temperature and relative humidity in the inside·outside of cooling tower on the moist air, and evaluated the performance of the heat exchanger.

히트 스프레더가 탑재된 노트북 PC의 냉각특성연구 (Cooling Characteristics of a Notebook PC Mounted with Heat Spreader)

  • 노홍구;임경빈;박만흥
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.77-82
    • /
    • 2000
  • Parametric study fur the cooling characteristic investigation of a notebook PC mounted with heat spreader has been numerically performed. Two oases of air-blowing and air-exhaust at inlet were tested. The cooling effect on Parameters such an, velocities of air-blowing and air-exhaust, materials of heat spreader, and CPU powers were simulated for two cases. Cooling performance in the case of air-blowing was better than the case of air-exhaust.

  • PDF

공냉-수냉 혼합냉각계통 개발 (Development of an Air-Water Combined Cooling System)

  • 권태순;배성원
    • 한국유체기계학회 논문집
    • /
    • 제17권6호
    • /
    • pp.84-88
    • /
    • 2014
  • A long term passive cooling system is considered as the most important safety feature for the nuclear design after the Fukushima Daiichi nuclear power plant accident in 2011. The conventional active pump driven safety systems are not available during a station Black Out (SBO) accident. The current design requirement on cooling time of the Passive Auxiliarly Feedwater System (PAFS) is about 8 hours only. To meet the 72 hours cooling time, the pool capacity of cooling water tank should be increased as much as 3~4 times larger than that of current water cooling tank. In order to extend the cooling time for 72 hours, a new passive air-water combined cooling system is proposed. This paper provides the feasibility of the combined passive air-water cooling system. The current pool capacity of water cooling system is preserved, and the cooling capability is extended by an additional air cooler.

압축냉각공기와 오일미스트를 이용한 환경친화 연삭가공기술 (Ecological Grinding Technology Using Compressed Cold Air and Oil Mist)

  • 이석우;최헌종;허남환
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.24-27
    • /
    • 2002
  • The environmental problems by using coolant demanded the new cooling methods. As one of them, the studies on the finding with compressed cold air and oil mist have been done. The cooling method using compressed cold air was effective through going down the temperature of compressed air supplied below $-25^{\circ}$ and increasing the amount of compressed cold air, but had not enough cooling effect due to the low performance of lubrication. Therefore, the cooling methods using oil mist newly were suggested. This method can satisfy both cooling effect and lubrication with only small amount of coolant, also have the benefit in the point of decreasing the environmental pollution. This paper focused on analyzing the grinding characteristics of the cooling method using oil mist. The grinding test according to compressed cold air, oil mist spray pressure and oil mist supply direction were done.

  • PDF

폴리머 열교환기를 사용한 냉각/재가열 시스템의 성능에 관한 연구 (A Study on the Performance of Cooling/Reheating System Using Polymer Heat Exchanger)

  • 김진혁;유성연;한규현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2154-2159
    • /
    • 2008
  • In conventional air-conditioning systems, when the circulated air from the air-conditioned space pass through the cooling coil in the air-conditioning system, the air is over-cooled to eliminate the moisture as well as to decrease the temperature. The purpose of this study is to test and evaluate performance of the cooling/reheating system which can save both cooling energy and reheating energy by exchanging heat between the cooled air and reheated air. Experimental apparatus consists of fan, ducts, polymer exchangers, cooling coil, electronic auxiliary heater and data acquisition system. Two types of polymer exchanger, plate type and dimple type, made of polypropylene for cooling/reheating system are designed. Heat transfer and dehumidification characteristics of system are tested. The results show that the energy saving is up to 40% in the range of present experimented conditions, and it decreases with increasing velocity, inlet temperature and specific humidity.

  • PDF

저압 에어포그 시스템을 설치한 온실의 냉방효율 (Cooling Efficiency of Low Pressure Compressed Air Fogging System in Naturally Ventilated Greenhouses)

  • 남상운;김영식;성인모;고기혁
    • 한국농공학회논문집
    • /
    • 제54권5호
    • /
    • pp.49-55
    • /
    • 2012
  • In order to derive the efficient utilization of low pressure compressed air fogging system, cooling efficiencies with control types were analyzed through cooling experiments in tomato greenhouses. The control types were set up with temperature control, humidity control, temperature and humidity control, and time control. It showed that the cooling effects were 0.7 to $3.3^{\circ}C$ on average and maximum of 4.3 to $7.0^{\circ}C$, the humidification effects were 3.5 to 13.5 % on average and maximum of 14.3 to 24.4 %. Both the cooling and humidification effect were the highest in the time control method. The cooling efficiency of the air fogging system was not high with 8.3 to 27.3 % on average. However, the cooling efficiency of 24.6 to 27.3 % which appears from the time control is similar to the cooling efficiency of high pressure fogging system experimented in Japan. The air fogging system is operated by low pressure, but its efficiency is similar to high pressure. We think because it uses compressed air. From this point of view, we suggest that the air fogging system can get the cooling efficiency of similar levels to that of high pressure fogging system and it will have an advantage from clogging problem of nozzle etc.

차압통풍 예냉 청과물의 냉각특성 (Cooling Characteristics of Fruits and Vegetables for Pressure Cooling)

  • 윤홍선;박경규
    • 한국식품저장유통학회지
    • /
    • 제4권3호
    • /
    • pp.237-243
    • /
    • 1997
  • Numerous variables affect product cooling rate of pressure cooling system for fruits and vegetables. These include carton vent area, initial and desired final product temperature, flow rate and temperature of the cooling air, product size, shape and thermal properties and product configuration(whether in bulk or packed in shipping cartons). This study was carried out to determine the influence of each of these variables as they affect cooling time. The opening ratio and number of the vent hole were recomended as 4∼10% and 2∼4ea., respectively, for a minimum alt flow resistance and for a uniform air flow pattern. In the cooling experiment for tomatoes and mandarins, optimum air flow rate was 0.04 m3/min.kg in terms of energy saving. The cooling air temperature should be about 2$^{\circ}C$ less than the desired final product temperature for reducing cooling time.

  • PDF

Experimental Study of Moisture-Wicking Fabric as Cooling Pad for Novel Rotary Direct Evaporative Cooler

  • Sang-Hwan Park;Jae-Weon Jeong
    • 국제초고층학회논문집
    • /
    • 제12권4호
    • /
    • pp.335-341
    • /
    • 2023
  • This study proposes a novel rotary direct evaporative cooler and investigates the potential of a moisture-wicking fabric as a cooling pad for the proposed evaporative cooler. The rotary direct evaporative cooler rotates the cooling pad to reduce the water and energy consumption of the pump compared to those of existing direct evaporative coolers. A moisture-wicking fabric is considered as the material of the cooling pad, because of its high moisture-wicking property, enhancing water evaporation. Experiments are performed under various inlet air conditions while measuring the air temperature, relative humidity, air velocity, and differential pressure. The evaporative cooling efficiency and impacts of the inlet air temperature and air velocity on the cooling performance are also evaluated. The results demonstrate the potential of the moisture-wicking fabric as cooling pad of direct evaporative cooler.

광섬유 고속인출공정용 유리섬유 냉각장치 내 공기유입에 의한 내부헬륨농도 저하현상 연구 (HELIUM CONCENTRATION DECREASE DUE TO AIR ENTRAINMENT INTO GLASS FIBER COOLING UNIT IN A HIGH SPEED OPTICAL FIBER DRAWING PROCESS)

  • 김경진;김동주;곽호상;박상희;송시호
    • 한국전산유체공학회지
    • /
    • 제15권4호
    • /
    • pp.92-98
    • /
    • 2010
  • In a modern high speed drawing process of optical fibers, it is necessary to use helium as a cooling gas in a glass fiber cooling unit in order to sufficiently cool down the fast moving glass fiber freshly drawn from the heated silica preform in the furnace. Since the air is entrained unavoidably when the glass fiber passes through the cooling unit, the helium is needed to be injected constantly into the cooling unit. The present numerical study investigates and analyzes the air entrainment using an axisymmetric geometry of glass fiber cooling unit. The effects of helium injection rate and direction on the air entrainment rate are discussed in terms of helium purity of cooling gas inside the cooling unit. For a given rate of helium injection, it is found that there exists a certain drawing speed that results in sudden increase in the air entrainment rate, which leads to the decreasing helium purity and therefore the cooling performance of the glass fiber cooling unit. Also, the helium injection in aiding direction is found to be more advantageous than the injection in opposing direction.