• Title/Summary/Keyword: Coolant Heater

Search Result 37, Processing Time 0.162 seconds

하나로 수조 방사선 준위의 저감 특성 (Reduction Characteristics of Pool Top Radiation Level in HANARO)

  • 박용철
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.221-226
    • /
    • 2001
  • HANARO, 30MW of research reactor, was installed at the depth of 13m of open pool, The $90\%$ of primary coolant was designed to pass through the core and to remove the reaction heat of the core. The rest $10\%$, of the primary coolant was designed to bypass the core. And the reactor coolant through and bypass the core was inhaled at the top of chimney by the coolant pump to protect that the radiated gas was lifted to the top of reactor pool. But, the part of core bypass coolant was not inhaled by the reactor coolant pump and reached at the top of reactor pool by natural convection and increased the radiation level on the top of reactor pool. To reduce the radiation level by protecting the natural convection of the core bypass flow, the hot water layer (HWL, hereinafter) was installed with the depth of 1.2m from the top of reactor pool. As the HWL was normally operated, the radiation level was reduced to five percent ($5\%$) in comparing with that before the installation of the HWL. When HANARO was operated with higher temperature than the normal temperature of the HWL by operating the standby heater, it was found that the radiation level was more reduced than that before operation. To verify the reason, the heat loss of the HWL was calculated. It was confirmed through the results that the larger the temperature difference between the HWL and reactor hall was, the more the evaporation loss was increased. And it was verified that the radiation level above was reduced more safely by increasing the capacity of heater.

  • PDF

연료전지 차량 스택 냉각수 부족 감지 방법에 관한 연구 (A Study on Sensing Method of the Stack Coolant Deficiency for FCEV)

  • 김형국;한수동;남기영;김치명;박용선
    • 한국수소및신에너지학회논문집
    • /
    • 제25권5호
    • /
    • pp.525-532
    • /
    • 2014
  • The sensing of a stack coolant deficiency is very important in that cooling performance of a fuel cell, overheating prevention of a stack or coolant heater. This paper explains the performance comparison between the coolant contact/noncontact level sensors and coolant deficiency sensing logic using the pressure sensor in a stagnant or circulating flow. Throughout the comparison, the pressure sensor is more suitable than the other sensors in terms of the precision, fast response, sensing frequency. After the experiment, the pressure sensor is equipped to an FCEV(Fuel Cell Electric Vehicle) to verify sensing definitely. There was no miss-sensing using pressure sensor while FCEV runs in the conditions of the paved road and cross country road.

자동차 에틸렌글리콜 부동액의 혼합 농도 측정 장치 개발 (Device Development of Mixture Concentration of Ethylene Glycol Antifreeze Coolant for Vehicles)

  • 이대웅;이은웅
    • 설비공학논문집
    • /
    • 제28권8호
    • /
    • pp.331-336
    • /
    • 2016
  • This study presents a coolant density calculation device and its corresponding method by using a mass flowmeter and the LabVIEW program. The method can be easily measured with a mixture of coolant and by calculating the percentage of ethylene-glycol without additional investment. The cooling water is very important in a vehicle to protect the engine, and the cooling performance is affected by the mixture concentration and coolant density. The coolant density calculation device measures the mixed concentration in the anti-freeze cooling mixture made from distilled water and ethylene-glycol in real time with the mass flowmeter that is commonly attached to the radiator or heater core. The calculation program for the mixture concentration percentage was developed using the LabVIEW software. The correlation between experimental results and the calculation was conducted for a range of temperature from 40 to $90^{\circ}C$ and by varying the mixture ratio of distilled water and ethylene-glycol. As a result, the anti-freeze coolant concentration in the volume percentage is able to monitor the coolant density in a timely basis by implementing a mixture concentration calculation program without the need for additional equipment investment. The results of the calculation for the mixture concentration level show a maximum 2.7% deviation compared to the experimental results.

전기차용 7kW급 고전압 히터 유로 형상 설계를 위한 열유동 시뮬레이션 (Thermo-Fluid Simulation for Flow Channel Design of 7kW High-Voltage Heater for Electric Vehicles)

  • 손권중
    • 한국융합학회논문지
    • /
    • 제13권3호
    • /
    • pp.191-196
    • /
    • 2022
  • 내연기관 자동차 히터는 연소과정 중에 발생하는 엔진 열을 이용하므로 열원이 추가로 필요치 않지만, 배터리로부터 동력원을 얻는 전기자동차용 히터는 별도의 전열 장치가 요구된다. 지금까지 개발된 전기차용 히터 중에서 냉매를 이용하는 고전압 히터는 효율이 높고 작동 온도 범위가 넓은 장점이 있다. 고전압 히터 내부의 냉각수 유로의 형상은 열교환 성능을 크게 좌우하므로 히터 개발 시 유로 설계는 기술적으로 매우 중요하다. 본 논문에서는 대칭형 서펜타인 유로를 갖는 7kW급 고전압 히터의 유로 형상 설계를 위해 고전압 열유동 시뮬레이션을 수행하였다. 해석결과로부터 입출구간 차압과 차온 및 유로에서의 유동 균일도를 계산하여 히터의 성능을 평가하였다. 도출된 대칭형 서펜타인 유로 설계안은 기존 평행 서펜타인 비해 차압은 높지만, 열교환 성능은 비등하며 저온부가 비교적 넓게 존재하여 제어 회로의 설치 공간으로 활용할 수 있다는 장점이 있다.

차량용 연소식 난방기의 열 및 유동특성에 대한 수치연구 (Numerical Investigation on the Thermal and Flow Characteristics of Combustion Heater for Commercial Vehicle)

  • 황창환;백승욱
    • 한국연소학회지
    • /
    • 제16권2호
    • /
    • pp.40-46
    • /
    • 2011
  • The diesel pre-heater has being used in cabin heating and coolant heating of engine to reduce the engine warm up time for commercial vehicle. The pre-heaters are classified as diesel spray combustor and it forms diffusion flame. By using swirler, a recirculation flow of hot product gases is established near the fuel nozzle and it helps the maintaining of diffusion flame. The design difference of swirler can affect on reaction characteristics and temperature distribution inside pre-heater. The purpose of this study is the investigation of the effect of swirler configuration on combustion characteristics. To solve spray combustion problem, the Euler-Lagrange approach discrete model is used to track droplet trajectory and evaporation history. The PDF equilibrium model is used for chemical reaction model. These models are implemented into the FLUENT code.

ENHANCEMENT OF DRYOUT HEAT FLUX IN A DEBRIS BED BY FORCED COOLANT FLOW FROM BELOW

  • Bang, Kwang-Hyun;Kim, Jong-Myung
    • Nuclear Engineering and Technology
    • /
    • 제42권3호
    • /
    • pp.297-304
    • /
    • 2010
  • In the design of advanced light water reactors (ALWRs) and in the safety assessment of currently operating nuclear power plants, it is necessary to evaluate the possibility of experiencing a degraded core accident and to develop innovative safety technologies in order to assure long-term debris cooling. The objective of this experimental study is to investigate the enhancement factors of dryout heat flux in debris beds by coolant injection from below. The experimental facility consists mainly of an induction heater, a double-wall quartz-tube test section containing a steel-particle bed and coolant injection and recovery condensing loop. A fairly uniform heating of the particle bed was achieved in the radial direction and the axial variation was within 20%. This paper reports the experimental data for 3.2 mm and 4.8 mm particle beds with a 300 mm bed height. The dryout heat density data were obtained for both the top-flooding and the forced coolant injection from below with an injection mass flux of up to $1.5\;kg/m^2s$. The dryout heat density increased as the rate of coolant injection increased. At a coolant injection mass flux of $1.0\;kg/m^2s$, the dryout heat density was ${\sim}6.5\;MW/m^3$ for the 4.8 mm particle bed and ${\sim}5.6\;MW/m^3$ for the 3.2 mm particle bed. The enhancement factors of the dryout heat density were 1.6-1.8.

전투차량 냉각수 호스 분리현상 개선에 관한 연구 (A Study on the Improvement of the Separation Phenomenon of Coolant Hose in the Tracked Combat Vehicle)

  • 강태우;신헌용;류정민;박경철;김재규;이헌기
    • 한국기계가공학회지
    • /
    • 제17권3호
    • /
    • pp.59-64
    • /
    • 2018
  • In general, tracked combat vehicles require excellent output performance of a power unit system to drive on special terrains and in extreme environmental conditions. However, high temperature and pressure are readily applied to the coolant hose in the power unit of the vehicles during high-speed driving under extreme road and weather conditions. These driving conditions can cause the separation phenomenon of the coolant hose in the power unit and consequentially engine overheating during driving. Therefore, a newly designed decompression device for the coolant hose has been proposed and manufactured to solve these problems in the present study. To validate of the newly proposed decompression device, the input and output pressures were measured under the before- and after-improvement conditions using experimental methods for different engine RPMs. In addition, the pre-heater temperature was measured under both conditions. From the experimental results, we expect that the current investigation can help to improve the driving performance of tracked combat vehicles.

3차원 열특성해석을 통한 히터트리거 고온초전도 스위치의 설계 (Design of Heater-trigger HTS Switch through 3-Dimensional Thermal Characteristic Analysis)

  • 안민철;윤용수;김호민;김태중;김영식;배덕권;이상진;한태수;고태국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.714-716
    • /
    • 2001
  • This paper is about the characteristic analysis of a heater-trigger HTS switch. It is composed of a BSCCO tape wire and a heater as a thermal quench source. To minimize the heat flow to the liquid nitrigen, the epoxy was used around them. The heater-trigger switch operates in the process that the HTS tape is thermally quenched by the current flowing through the heater. Since the switch works in coolant, it needs to be designed by the accurate thermal characteristic analysis. Here, we focus on FEM for it.

  • PDF

엔진 및 차량냉각계의 냉각수유량 측정실험 및 계산방법에 관한 연구 (A Study of the Experiment and the Calculation Method on the Coolant Flow Rate of Engine and Vehicle Cooling System)

  • 오창석;유택용;이은현;최재권
    • 한국자동차공학회논문집
    • /
    • 제7권6호
    • /
    • pp.1-7
    • /
    • 1999
  • In this study, the prediction method of coolant flow rates has been developed and applied to an engine and vehicle cooling system. The flow rate passing through each component of the system is very important parameter to evaluate the heat transfer process form the combustion gas to the coolant and the heat rejection process form the radiator /heater to the ambient air. However, the present study reveals that the measurement using the flowmeter fails to give practical flow rates due to its additive resistance. In contrast, the present method which uses the parallel and serial relationship of flow resistance proved to be a good tool to predict the real flow rates. It can be also used to design the cooling system in the incipient stage of engine/vehicle development . The procedure was coded to the computer program so as to use it flexibly and, in the future, to expand it into an independent design tool of the whole cooling system including the heat release and rejection.

  • PDF

냉각수 순환 가열 방식을 이용한 요소수의 동결 및 해동 특성에 관한 수치적 연구 (Numerical Investigation of Urea Freezing and Melting Characteristics Using Coolant Heater)

  • 이승엽;김남일;박윤범;김만영
    • 대한기계학회논문집B
    • /
    • 제37권8호
    • /
    • pp.717-724
    • /
    • 2013
  • Urea-SCR은 동절기, 북유럽과 북미지역과 같은 $-20^{\circ}C$ 이하의 환경에서 요소수가 동결되는 문제점을 해결해야 한다. 따라서 이러한 요소수 저장탱크에 해동 시스템을 적용하여 시동 초기, 요소수를 적정 시간 내 분사하기 위한 기술의 확보가 필요하다. 본 연구에서는 저장탱크 내 요소수의 동결현상과 냉각수 순환 가열방식을 적용한 해동현상에 대하여 상용 소프트웨어인 Fluent 6.3을 이용하여 3차원 비정상상태 수치해석을 수행하였다. 이를 통하여 요소수의 동결 및 해동과정 중 나타난 온도분포, 상경계면, 그리고 액상분율을 분석하여 열전달 특성을 고찰하였다. 결론적으로 요소수의 동결은 저장탱크 벽면으로부터 중심부로 이루어졌으며, 해동현상은 순환 파이프와 인접할수록 요소수의 상변화가 빠르게 진행하였다. 또한, 냉각수의 $70^{\circ}C$, $200{\ell}/h$ 조건에서 $1{\ell}$의 액상 요소수를 얻는데 약 190초의 시간이 필요하였다.