• Title/Summary/Keyword: Cool area

Search Result 183, Processing Time 0.021 seconds

Comparative Evaluation of Cool Surface Ratio in University Campus: A Case Study of KNU and UC Davis (대학 캠퍼스의 쿨표면 비율 비교평가: 경북대학교와 UC Davis를 사례로)

  • Hwang, Young-Seok;Um, Jung-Sup
    • KIEAE Journal
    • /
    • v.15 no.1
    • /
    • pp.117-127
    • /
    • 2015
  • The cool surface ratio could be used as a proxy of the overall thermal environment contributing to heat islands in urban area. This research proposes a comparative evaluation framework in an objective and quantitative way for measuring cool surface ratios. Two university campuses (Kyungpook National University: KNU, South Korea and UC Davis: University of California, Davis, USA) were selected as case study sites in order to monitor cool surface condition. Google Earth combined with digital maps realistically identified the major type of cool surfaces such as cool roofs and water bodies in the study area. Cool surfaces were sparsely identified over the KNU campus while the UC Davis campus was heavily covered by cool surfaces such as cool roofs and water bodies, resulting in almost four times more first-grade cool surfaces, as compared to KNU. It is confirmed that standard remote sensing technology can offer the viable method of measuring and comparing the campus-wide cool surface condition. It is anticipated that this research output could be used as a valuable reference to initiate a nation-wide cool surface strategy since objective evidence has been provided based on area-wide measurement for the cool surface in the two university context.

A Study on the Korean Ondol-System Application in Apartment Houses (공동주택의 한국형 온돌시스템 적용에 관한 연구)

  • Ahn, Min-Hee;Choi, Chang-Ho;Yu, Ki-Hyung;Cho, Dong-Woo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.860-865
    • /
    • 2006
  • The traditional Korean Ondol System that is a radiant floor heating system was made as warm floor and cool indoor temperature. Nowaday, Ondol is developed as the hydronic floor heating system. But unbalance of floor temperature and indoor temperature is occurred bocause strengthen thermal insulation and airtightness in building changes thermal performance. To solve these problems, we examine actual indoor environment of heating system methods in existing apartments and present the new method of floor heating system. The existing heating system made definite indoor temperatures but floor temperatures that is $22^{\circ}C-26^{\circ}C$ was maintained. To solve these problems, we adopted the differential heating system which made warm area and cool area. A differential heating system was made different pitches of heating pipe in single zone and ratio of warm area to cool area is 1 to 2. As a result of experiments, warm area temperature is $40.7^{\circ}C$, cool area temperature is $36.1^{\circ}C$. A difference of temperature between both area is 4K. A distribution of indoor vertical temperature is similar to both warm area and cool area.

  • PDF

Expansion of Cool Roof Policy through Thermal Measurement of Eco-Friendly Ceramic Coating (친환경 세라믹 도료 열적측정을 통한 쿨루프 정책 확대방안)

  • Park, Min Yong;Lee, Dong Ho
    • Land and Housing Review
    • /
    • v.11 no.3
    • /
    • pp.75-82
    • /
    • 2020
  • The urban heat island phenomenon that accelerates global warming has always been controversial when summer heatwaves have occurred since it was first investigated and described by Luke Howard in the 1810s. In Korea, since 2014, government have been interested in Cool Roof and painted white coating on the rooftops of the aging and weak buildings, and the cool roof business has expanded nationwide. However, the roof occupies 20-25% of the entire city surface, much less than 37-45% of the pavement area consisting of roads, parking lots and sidewalks, there is a need to expand the policy of Cool Pavement as a way to reduce the urban heat island phenomenon. Domestic cities are high-rise buildings centered on apartments, and the area occupied by outer walls is larger than that of rooftops compared to foreign low-rise buildings. Therefore, as a way to reduce the urban heat island phenomenon, there is a need for a policy to expand the Cool Roof in buildings and use Cool Wall in parallel. Therefore, this study aims to present the expansion of Cool Wall in buildings and Cool Pavement in urban areas, expanding the installation range of Cool Roof, by comparing and reviewing the thermal characteristics of eco-friendly ceramic coating with excellent thermal proof performance and coatings used for roof waterproofing.

A Study on the Development of Dance Sportswear with Cool-touch Function (냉감 기능성 댄스스포츠 웨어 개발에 관한 연구)

  • Jun, Mi-Hwa;Jang, Jeong-Ah;Koo, Young-Seok
    • Fashion & Textile Research Journal
    • /
    • v.22 no.1
    • /
    • pp.66-75
    • /
    • 2020
  • This study helps develop cool-touch functional dance sportswear. We suggest a draft design for dance sportswear that chooses appropriate cool-touch functional materials based on an investigation of the changes of body surface temperature before and after exercise, the physical properties of cool-touch materials on the market, and the preference for cooling tools. The results are as follows. First, cool-touch functional sportswear products on the market utilize materials such as PCM, Delta fabric, high gauge fabric, and ice chips as well as incorporate functions such as UV block and eyelets for enhanced breathability. Polyester and polyurethane fibers are mainly used for cool-touch functional sportswear. Second, the neck area showed the highest surface temperatures (32.7℃ and 32.1℃) before and after exercise. Body surface temperatures measured after exercise were also lower than temperatures measured before exercise when wearing dance sportswear. Third, as for the physical properties of cool-touch materials, material 1 showed amaximum drying speed (130 min), material 3 the best moisture absorption speed (122 × 132 min), and material 4 the best thermal conductivity (0.013 7 w/m·K). Fourth, a draft design for a cool-touch functional dance sportswear was suggested, including a neckband made of removable soft PVC material on the neck area and applying material 4 in F1, B4, S2 and lower arm areas and material 1 in the armpit area. Deodorant tape was also attached to the armpit area for added comfort and antibacterial deodorant effect.

Ablation Characteristics of Bovine Liver According to Cool-Tip Temperature of RFA Equipment (고주파 열치료 장비의 Cool-Tip 온도에 따른 소간의 소작 특성)

  • Choi, Young-Jae;Kim, Jeong-Koo
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.155-161
    • /
    • 2015
  • This study confirmed the correlation between the change of the cooling water in internal cooling system and the size of the ablation site of bovine liver in RF heat treatment equipment. The bovine liver was resection with $4{\times}4{\times}4cm^3$ in 2cm cool-tip and with $6{\times}6{\times}6cm^3$ in 3cm cool-tip for the experiments. Area and perimeter of the ablation site for bovine liver were measured by Freehand techniques of MRI. It showed area and perimeter decreased during cool-tip temperature rises 6 and 12 minutes ablation using a 2cm and 3cm cool-tip. The correlation of cool-tip temperature and area and perimeter was statistically significant the result are shown(p=.000). The measurements of area and perimeter were more accurate with MRI in actual measurements and MRI for ablation range. The statistical results using Paired sample T-test was also significant(p=.038). The ablation range of bovine liver decreased according as cooling water temperature increases in RF heat treatment equipment for reason of carbonization occurred due to does not accurately pass the RF energy. Therefore, it is considered the effect of RF heat treatment would be increased if the temperature of the cooling water consistently maintain the low temperature in order to reduce the generation of carbide at RF heat treatment and RF energy is delivered accurately.

Comparative Evaluation of Surface Temperature among Rooftop Colors of Flat Roof Building Models : Towards Performance Evaluation of Cool Roof (평지붕 건물 축소모형의 지붕색에 대한 표면 온도의 비교평가: 쿨루프 성능평가 차원에서)

  • Ryu, Taek Hyoung;Um, Jung-Sup
    • KIEAE Journal
    • /
    • v.13 no.6
    • /
    • pp.83-91
    • /
    • 2013
  • Cool roofs are currently being emerged as one of important mechanism to save energy in relation to the building. It is specifically proposed that the changing trends of rooftop surface temperature in the flat roof building model could be used effectively as an indicator to reduced cooling load reduced by cool roof since it can present stable temperature record, that is not influenced according to the nearby physical as well as human variables. The temperature of cool roof in summer was lower around $20^{\circ}C$, compared to the general roofs. Such a seasonal or daily comparative study for rooftop temperature in the building model will highlight that the cool roof efficiency could be calculated in much area-wide context according to rooftop color distribution in urban residential area. It is anticipated that this research output could be used as a valuable reference in identifying energy saving by cool roof since an objective monitoring has been proposed based on the rooftop temperature in the building model, fully quantitative performance of thermal infrared image.

Development of Triacetate-containing Functional Coolness Fabrics with Cool-Touch and Cool-Absorbent (접촉 냉감 및 흡수 냉감을 갖는 트리아세테이트 함유 기능성 냉감 직물 개발)

  • Kim, Myoung Ok;Lee, Jung-Soon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.42 no.5
    • /
    • pp.799-808
    • /
    • 2018
  • This study develops triacetate-containing functional fabrics with a cool-touch and cool-absorbent. For this purpose we used composite yarns made using triacetate filament and PET High absorbance quick dry filament as well as the composite fabric woven. The fineness of the yarn and structure of fabric varied the cover factor varied. The blend ratio of triacetate was differently set. When the triacetate content was the same, the cool touch of the fabric having a large cover factor and small SMD increased. The surface became smooth and the contact area became large; in addition, both the Qmax value and the cool-touch became large. In the case of similar density, the cool-touch of the fabric having a large content of triacetate increased. The cool-absorbent of the fabric containing triacetate showed a similar level of the PET High absorbance quick dry filament fabric treated with and endothermic cooling agent. It was possible to develop a functional coolness fabric with a cool-touch and a cool-absorbent when the content of triacetate and cover factor were well combined.

Analysis of Surface Fibers by Wavelet Transform and Subjective Evaluation of Wool Fabrics (웨이블릿 변환을 이용한 모직물의 표면섬유 분석과 주관적 감각 평가)

  • 김동옥;김은애;유신정
    • Science of Emotion and Sensibility
    • /
    • v.5 no.3
    • /
    • pp.53-59
    • /
    • 2002
  • The surface fibers on the fabric is one of decisive factors which affects human sensory evaluation as well as heat and moisture transfer characteristics. In this study the length and distribution of surface fibers that are extruded from the fabric surface of the wool/wool blend fabrics (14 wool fabrics and 10 wool blend fabrics) and its contribution to subjective sensory evaluation were investigated. In order to quantify the length and distribution of surface fibers, image analysis and wavelet transform technique were introduced. Instant warm-cool feeling of touch, Q$\_$max/, and contact area were also measured and related to the quantified surface fibers. To figure out the effect of surface characteristics on sensory evaluation, human sensory responses to three adjectives which represent surface characteristics and warm-cool feeling of touch were obtained and analyzed. The relationship between the quantified surface fibers assessed by wavelet energy and both warm-cool reeling of touch, Qmax, and human sensory response were discussed.

  • PDF

A Study on the Utilizing of Cool-season Turfgrass of Golf Courses in Korea (우리나라 골프 코스에서 한지형 잔디의 활용방안)

  • 이상재;심경구;허근영
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.29 no.2
    • /
    • pp.77-84
    • /
    • 2001
  • This study was carried out to investigate the utilizing of cool-season turfgrass in areas, excluding greens, of Korean golf courses. Data collected from 120 golf courses were subjected to frequency and T-test analysis using SPSSWIN. The results obtained were as follows: 1) seventy eight golf curses were utilizing cool-season turfgrass in areas except of the greens. At thirty five golf courses (46.0%) of them, the area utilized appeared tee, green collar, green approach etc. (tee>green collar>green approach). At 37 golf courses(48.7%), a mix of Kentucky Bluegrass and Perennial Ryegrass was utilized and the ratio of the mix was 70:30(v/v). At 57 golf courses(76.0%), seed sowing was utilized. 2) In Korean golf courses, the cognition of utilizing cool-season turfgrass depended on the existence of the practice. The cognition of the experienced was more´ affirmative´ than that of the inexperienced. 3) In the experienced, the preference was determined by turfgrass quality and good appearance and recuperative rate of cool-season turfgrass. In the inexperienced, the preference was determined by turfgrass quality god appearance. 4) The experienced recommended the mix of Kentucky bluegrass and Perennial Ryegrass. 5) It seems that the golf courses having used cool-season turfgrass have difficulties in the maintenance in summer while the golf courses without using cool-season turfgrass have difficulties in the maintenance in summer and the selection of turfgrass variety.

  • PDF

Climate Change Vulnerability Assessment of Cool-Season Grasslands Based on the Analytic Hierarchy Process Method

  • Lee, Bae Hun;Cheon, Dong Won;Park, Hyung Soo;Choi, Ki Choon;Shin, Jeong Seop;Oh, Mi Rae;Jung, Jeong Sung
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.41 no.3
    • /
    • pp.189-197
    • /
    • 2021
  • Climate change effects are particularly apparent in many cool-season grasslands in South Korea. Moreover, the probability of climate extremes has intensified and is expected to increase further. In this study, we performed climate change vulnerability assessments in cool-season grasslands based on the analytic hierarchy process method to contribute toward effective decision-making to help reduce grassland damage caused by climate change and extreme weather conditions. In the analytic hierarchy process analysis, vulnerability was found to be influenced in the order of climate exposure (0.575), adaptive capacity (0.283), and sensitivity (0.141). The climate exposure rating value was low in Jeju-do Province and high in Daegu (0.36-0.39) and Incheon (0.33-0.5). The adaptive capacity index showed that grassland compatibility (0.616) is more important than other indicators. The adaptation index of Jeollanam-do Province was higher than that of other regions and relatively low in Gangwon-do Province. In terms of sensitivity, grassland area and unused grassland area were found to affect sensitivity the most with index values of 0.487 and 0.513, respectively. The grassland area rating value was low in Jeju-do and Gangwon-do Province, which had large grassland areas. In terms of vulnerability, that of Jeju-do Province was lower and of Gyeongsangbuk-do Province higher than of other regions. These results suggest that integrating the three aspects of vulnerability (climate exposure, sensitivity, and adaptive capacity) may offer comprehensive and spatially explicit adaptation plans to reduce the impacts of climate change on the cool-season grasslands of South Korea.