상완혈 자침시 복부 장기의 안전성 확보를 위한 초음파시스템의 신뢰도 측정 (Reliability Measurement of the Ultrasound for Safety of the Abdominal Organs on Acupuncturing Sangwan (CV13))

  • 김지혜;백태현
    • 대한한의진단학회지
    • /
    • 제15권2호
    • /
    • pp.203-214
    • /
    • 2011
  • Objectives: The objective of the current study is to determine whether an ultrasound device system is adequate for measuring distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver. Methods: We recruited 3 healthy young male subjects and 2 sonographers. The each sonographer measured vertical shortest distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver with a ultrasound device with three methods of 3.5 MHz convex probe and gel, 9 MHz linear probe and gel, and 9 MHz linear probe and solid gel pad, three times in random order. Because the total variation could be divided into repeatability, reproducibility and subject-to-subject variation in Gage R&R method, we compared the sources of variation associated with the measurement system with an analysis of variance model. Results & Conclusions: Number of distinct categories is calculated on the basis of standard deviation of subject-to-subject divided by standard deviation of total Gage R&R. If the number of categories is five or more, the measurement system may be acceptable for the analysis of the process. The number of distinct categories of the ultrasound device system for measuring distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver were 9.20 (9 MHz linear probe and gel), 14.70 (9 MHz linear probe and solid gel pad). So we concluded that repeatabilities and reproducibilities of the ultrasound device system for measuring distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver with the methods of 9 MHz linear probe and gel, and 9 MHz linear probe and solid gel pad were acceptable.

초음파검사에서 인체모의 매질팬텀을 이용한 온도 변화와 TI MI 분석 (An Analysis of Temperature Change and TI MI using Tissue Mimicking Phantom in Ultrasonic Examination)

  • 전철민;한재복;곽종길;송종남
    • 한국방사선학회논문지
    • /
    • 제16권6호
    • /
    • pp.751-759
    • /
    • 2022
  • 현재 진단 초음파 및 건강검진 목적의 초음파 검사는 널리 이용되고 있고 건강보험 적용으로 더욱 증가 추세를 보이고 있다. 하지만 초음파검사의 위해성은 현재까지 명확히 밝혀진 바가 없어 초음파 검사 시 인체 조직의 온도가 상승하는 열효과를 알아보고자 본 연구에서는 인체 모의 매질 팬텀을 이용해 주파수, 모드별에 따른 표면과 심부 온도 변화를 시간별로 측정하였고 TI, MI 값도 비교하였다. 인체와 유사한 음향 특성 있는 카파 카라기난 분말과 고형화를 위해 염화칼륨을 소량 첨가하여 모의 팬텀 제작하였고 표면 온도계와 탐침용 온도계를 사용하여 표면과 심부 온도 변화를 측정하였다. 그 결과 저주파수를 사용하는 Convex Probe가 고주파를 사용하는 Linear Probe보다 높은 온도 상승을 보여 유의미한 차이를 보였고 표면에서 온도 상승이 가장 높았으며 1 cm의 낮은 깊이는 일시적 온도상승은 나타내지만 유의미한 온도변화는 없었다. 5 cm ~ 15 cm의 심부온도 변화는 없었으며 검사 시간동안 TI, MI값은 변화가 없었다. 이는 15분 실험동안 표면온도만 상승하였고 심부에는 온도변화가 없었기 때문에 인체에 유해할 만큼의 온도 변화를 나타내지 않을 것으로 사료되며 통상적인 진단초음파의 15분의 검사시간은 임상에서의 사용에는 무리가 없을 것으로 생각되지만 특정 부위의 장시간 검사는 온도 상승을 일으킬 수 있으므로 지양해야 될 것으로 사료된다.

Convex Probe 소독 필요성 검증에 관한 연구 (A Study on the Necessity Verification of Convex Probe Disinfection)

  • 최관용;유세종;이준호;홍성용
    • 한국방사선학회논문지
    • /
    • 제13권2호
    • /
    • pp.193-200
    • /
    • 2019
  • 본 연구는 대전, 충청지역 초음파실 종사자를 대상으로 병원감염관리에 관한 설문 조사를 실시하여 분석하였고, ATP를 이용하여 임상에서 사용되는 초음파 Probe의 오염도를 측정하였으며, 70% 알코올 이용하여 소독한 후 결과를 확인하였다. 기본적인 조사 대상자의 일반적인 특성 및 직종 별 대상자의 특성으로 나누어 학력, 직종, 초음파 전문자격증 보유 유무, 기관 내 감염 담당 부서 및 감염 교육의 여부를 분석하였다. 검사 후 젤 제거 여부 및 방법, Probe의 소독여부 및 변수 별 상관분석을 수행하여 초음파 Probe의 세균감염에 관한 인식 및 세척 및 소독에 대한 수행 정도를 분석하였다. 검사 후 Probe 세척에 관하여 수건을 가장 많이 사용하였으며, Gel 용기는 3개월 이상 교환하지 않는 것으로 나타났다. 70% 알코올 소독 후 ATP 오염도는 $1055.4{\pm}944.2$에서 $133.5{\pm}93.2$으로 감소하였고 통계적으로 유의한 것으로 분석되었다.(${\rho}<0.01$) 병원균종은 CNS, Gram positive bacillus, Micrococcus species 검출되었다. 이를 해결하기 위해 시중에서 손쉽게 구할 수 있는 70% 알코올을 이용하여 소독을 실시하였으며 소독 후 병원균종은 검출되지 않았다. 연구 결과 초음파실을 관리하는 의료인 또는 의료기사 등은 감염관리에 대한 주기적인 교육과 감염예방에 대한 노력이 필요하다고 볼 수 있으며, 70% 알코올은 병원균 사멸에 효과적인 것으로 나타났다. 따라서 의료기관은 적극적인 병원감염관리 교육을 실시하여 종사자들의 병원감염에 관한 인식을 개선하고, 환자 감염 예방에 기여해야 할 것이다. 또한 본 연구 결과를 적절히 활용한다면 초음파 Probe를 매개로 한 감염 예방에 도움이 될 것으로 사료된다.

강아지에서 컨벡스스캐너를 이용한 정상적인 심장구조물의 초음파상 (Ultrasound Imaging of Normal Cardiac Structures with Convex Scanner in Puppies)

  • 정순욱;박희명;한숙희;윤정희;한홍율
    • 한국임상수의학회지
    • /
    • 제11권2호
    • /
    • pp.529-537
    • /
    • 1994
  • Sector scanner which has a conical end is used to image through the intercostal space because heart is protected by the ribs. Cardiac data published all around the world were also obtained by sector scanner. Although scanners being used in every small animal practice and animal hospital at college in Korea include convex ape and linear type, linear type is not appropriate f3r cardiac scan because of a wide contact surface. The purpose of this study is to establish ultrasonographic images of normal cardiac structures by measuring shape, size of reflectable cardiac structure according to restraint position in scanning normal heart of the puppies with 6.5 MHz convex scanner(SonoAce 4500, Medison, Korea) used in our veterinary teaching hospital, Seoul national university. Seventeen male and female puppies considered having healthy hear by X-ray and clinical examination are used feom April to July 1994. Scanning point selection of probe head and the distinction of imaged cardiac structures were accomplished by necropsy and cardiac scanning performed through thoracotomy under general anesthesia. At 10 o'clock position of transducer(at an angle of 30$^{\circ}$ between imaginary line from elbow joint to 3rd sternum and probe head, 60$^{\circ}$ from body surface, 4th intercostal space of right thorax) with the marker of scanner toward the head of dogs right atrium, left atrium and left ventricle were observed in 2, 3, 4, 5 intercostal space(2cm from the sternum) of experimental dog positioned ventrodorsally under general anesthesia. Under these conditions, the numerical values of imaged diastolic hear are as follows : the distance from skin to apex(mean$\pm$S.D) 47.53$\pm$6.94mm, thickness of left ventricular wall 6.00$\pm$1.60mm, length of left ventricle 16.27$\pm$5.31mm, width of left ventricle 15,33$\pm$4.25mm, length of left atrium 12.33$\pm$3.82mm, width of left atrium 11. 33$\pm$3.94mm, length of right atrium 1.00$\pm$2.41mm, width of right atrium 11.21$\pm$2.76mm and the area of left ventricle 270.92$\pm$109.81mm$^2$, area of left atrium 98.00$\pm$41.08mm$^2$, area of right atrium 62.75$\pm$21.04mm$^2$.

  • PDF

진단용 초음파 Probe 및 Mode 변화에 따른 초음파 주사빈도가 콩나물 발아 과정에 미치는 영향 (Effect of the Bean Sprouts Growth by Scanning Frequency of Diagnostic Ultrasound Probe Type and Mode Change)

  • 최관용;임현수
    • 대한의용생체공학회:의공학회지
    • /
    • 제36권5호
    • /
    • pp.150-154
    • /
    • 2015
  • Long time ultrasound scan can cause a temperature rise in human tissue and affect the physical body. This is closely connected with patients' safety. So many researchers have been studied on this matter with animals such as mammals and experimental rat, because diagnostic ultrasound has been used many types of human organ to find disease. Therefore, this study is tested on bean sprouts to search how far the tissue temperature changes because of the excessive scanning consequence from ultrasound diagnosis and frequent number of ultrasonic scanning and how much affect their growth. The United States and several European countries have restrictions for number of scanning, while South Korea does not have any limitation for using ultrasound diagnosis. Comparison was that how different condition affect its' growing. The testing group is like many pregnancy moms to have 50 minutes in B-mode and color doppler mode by linear, convex and sector probe every day for a week and the other is to scan only once during the testing period. As a result, it was confirmed that there was a significant growing difference on frequent ultrasonic scanning group compared to normal one. So the final conclusion is that there needs to have a significant limitation of ultrasound scan time and a number of inspection when having for diagnostic ultrasound and recommendation like USA and a few European countries.

신소재를 사용한 인체조직모사물질의 합성과 초음파 물리적 특성에 관한 연구 (The Study on Ultrasound Physical Characteristic and Synthesis of Tissue Mimicking Materials Used New Materials)

  • 마상철;김화선;안영만
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제33권3호
    • /
    • pp.245-252
    • /
    • 2010
  • 본 연구는 주제인 폴리우레탄(polyurethane, PU)과 새로운 형태의 n-type 산란재를 사용하여 합성한 조직모사물질(tissue mimicking materials : TMM)에 대해 국제표준규격 IEC 60601-2-37(2007)의 Annex D.D가 권고한 인체 연조직(soft tissue)의 음향학적 특성 기준에 준해, 전파속도, 임피던스, 감쇠계수 특성 등을 분석하였으며, 영상특성은 SONOACE 9900C PRIME(MEDESON Co.), 3.5 MHz 컨벡스 프로브(2.5-5.0 MHz)로 초음파 휘도와 최대투과심도를 분석 평가하여 다음과 같은 결론을 얻었다. 주제인 prepolymer와 polyol mixture를 혼합하고 n-type 산란재를 0~8%로 점차 증가하여 합성하였을 때, 1. 조직모사물질의 전파속도는 산란재가 증가할수록 연조직에 더 가깝게 수렴(convergence)하였다. 2. 음향임피던스는 산란재가 감소할수록 연조직에 더 가깝게 수렴하였다. 3. 감쇠계수는 산란재가 증가할수록 증가하였다. 4. 영상 평균휘도는 산란재가 증가할수록 증가하였으나 역치가 있었다. 5. 최대투과심도는 산란재 6% 조직모사물질에서 연조직에 가깝게 수렴하였다.

외이염 발생견에서 고막평가를 위한 초음파 및 이경 검사법 비교 (Comparison of Ultrasonography and Video-otoscopy for the Evaluation of the Tympanic Membrane in Otitis Dogs)

  • 이종원;엄기동;성윤상;이해운;문금정;배선희;변태경;송경호;전종훈;장광호;오태호;이근우
    • 한국임상수의학회지
    • /
    • 제22권4호
    • /
    • pp.382-385
    • /
    • 2005
  • The aim of this study was to compare ultrasonography with video-otoscopy for the evalution of the external ear canal and the tympanum. Fifty dogs with clinical signs ot the bilateral ear diseases were examined using otoscopy under general anesthesia. Ultrasonographic examination was performed with an 11 MHz linear-arrary probe and a 6.5MHz convex probe, with the external ear canal filled with saline. Saline functioned as a contrast media and enhanced image quality of ultrasonography. The images of 100 ears before and after the ear cleansing were obtained at otoscopy and ultrasonography. On the video-otoscopic images, the tympanic membrane was identified in 59 ears before the ear cleansing and 91 ears after cleansing. On the ultrasonography, the tympanic membrane was detected in 98 ears before the ear cleansing and in all ears after cleansing. With these results, it was concluded that ultrasonography with infusing saline into the ear canal, could be a useful diagnostic procedure to identify the tympanic membrane in otitis dogs.

The Difference of the Changes of Images on Ultrasound Scanner Setting Parameters

  • Kang, Hae-Kyung;Kim, Youn-Min;Kim, Hyun-Soo;Lee, Sung-Hee;Cho, Se-Youn;Lyu, Young-Eun;Jung, In-A
    • 대한디지털의료영상학회논문지
    • /
    • 제12권2호
    • /
    • pp.81-87
    • /
    • 2010
  • The setting parameters of ultrasound scanner give influences to change of image. Sonographers have used a Matlab program to make Low Contrast Sensitivity(LCS) value and compared original images in order to evaluate the use of the supersonic diagnosis machinery. We confirmed the change of image in Grayscale values using Photoshop program. Experiment equipment of our research used A Medison Accuvix V10, A Multi-Tissue Ultrasound Phantom(040 GSE) of CHRIS Company, A Adobe Photoshop CS4 Program, A Convex Probe, A USB memory stick, A Probe Fixation Equipment. The method used Gain, Dynamic Range(DR) of the setting parameters of ultrasound scanner and researched Gain and DR was set to 10 dB. We changed the different settings to see the changes of images using Grayscale values of a Photoshop program about tissue images of a phantom. This study evaluated DR and Gain whether it is an image controller to get the optimum contrast to produce an image to see the how effect on the images. We did not use Gateway in supersonic diagnosis machinery. We can easily open to open the files through Photoshop program before we get Digital Imaging and Communications in Medicine(DICOM) files use USB memory stick in supersonic diagnosis machinery. When we diagnosed the lesion of the patient with ultrasound, the contrast and the Gray scale value of image are very important. In this research, we determined the optimum setting parameters that provided useful information to diagnose disease and evaluated the change of improved images.

  • PDF

초음파 스캔에서 알코올 겔 적용 시 화질과 소독효과 분석 (Analyzing Image Quality and Disinfection Effectiveness of Alcohol Gel Application in Ultrasound Scans)

  • 김현주
    • 한국방사선학회논문지
    • /
    • 제18권4호
    • /
    • pp.365-372
    • /
    • 2024
  • 초음파 스캔에서 알코올 겔 적용 시 화질과 소독 효과 분석을 위해 초음파 겔과 알코올 함유량이 다른 소독용 알코올 겔을 변경 적용하여 실험하였다. 화질 분석은 ATS-539 다목적 팬텀을 이용하여 사각 구역, 축 및 측 방향 분해능, 민감도, 회색 조의 변화 항목을 비교해 보았고, 소독 효과 분석은 임상에서 사용 중인 볼록형 탐촉자 3개의 덮개 면을 swab을 통해 검체 수집과 24시간 증균배양한 후 gram stain과 identification을 하였다. 화질 분석 결과 알코올 함유량과 상관없이 모든 항목에서 초음파 겔 적용 영상과 차이가 없는 영상으로 구현되었으며, 모든 탐촉자에서 staphylococcus aureus, streptococcus, enterococcus 등의 병원균이 검출되었고 소독용 알코올 겔 적용으로 모두 사멸하였다. 초음파 검사 시 알코올 겔 적용은 화질 유지와 소독 효과 측면에서 의미가 있었으며 본 연구결과를 바탕으로 지속적인 후속 연구를 진행하고 보완하여시 제품화한다면 초음파 겔 대체재로 알코올 겔 적용은 화질뿐만 아니라 감염 예방 측면까지 고려할 수 있어 임상 검사 시 매우 유용할 것으로 판단된다.

Identification of High Frequency Peakers with long-term monitoring observation at 22 and 43 GHz

  • Jeong, Yongjin;Sohn, Bong Won;Chung, Aeree
    • 천문학회보
    • /
    • 제39권2호
    • /
    • pp.68.2-68.2
    • /
    • 2014
  • High Frequency Peakers (HFPs) are radio-loud Active Galactic Nuclei (AGN), which are regarded as being in the earliest evolutionary phase (102-103 years) of radio galaxies. They are expected to be small in size (< ~1 kpc) compared to their host galaxies (~a few 10s kpc), and have convex spectra, which are peaking at high radio frequency (> 5 GHz). Their size and spectral shape are the most obvious supporting evidence of extremely young ages. HFPs are therefore ideal targets to probe the earliest stage of radio sources. To date however, the young radio source classification has been relying mainly on the spectral shape which usually does not cover high enough frequencies where the true peak flux is located. Hence HFPs are often confused with blazars which may show a similar spectral shape and apparent compactness but are a somewhat evolved form of AGNs. Therefore, we have been challenging to identify HFPs among the sample of 19 candidates using the Korean VLBI Network (KVN) which enables us to extend the radio spectrum baseline up to 22 and 43 GHz. These are higher than the frequencies used in most previous studies of HFPs, allowing us to select genuine HFPs. By long-term monitoring of 18 epochs, we have also inspected the variability of the sample to select out blazars which are highly variable yet with a similar radio spectrum. In this work, we present the light curves and spectral properties of the HFP candidates. We discuss the results of our re-identification of HFPs.