• Title/Summary/Keyword: Converter control

Search Result 3,157, Processing Time 0.032 seconds

Stability Analysis of DC-DC Boost Converters Based on Output Impedance in HSS (고조파 상태 공간 출력임피던스에 기반한 DC-DC 부스트 컨버터의 안정도 해석)

  • Heryanto, Nur A.;Park, Bumsu;Lee, Dong-Choon
    • Proceedings of the KIPE Conference
    • /
    • 2020.08a
    • /
    • pp.455-456
    • /
    • 2020
  • This paper proposes stability evaluation of DC/DC boost converters based on output impedance in harmonic transfer function matrix considering line impedance and cascaded voltage and current control loops. The harmonic state-space (HSS) model of converter and controller is developed to obtain the harmonic transfer function matrix of closed-loop output impedance. This work is useful for impedance-based stability analysis of converters connected to DC power systems.

  • PDF

Analysis of the Injected Zero-Sequence Voltage for Improving Dynamics of Energy Balancing Control with Wye-Connected CHB Converter (Y 결선 CHB 컨버터 에너지 균형 제어 동특성 향상을 위한 주입 영상분 분석)

  • Kim, Jae-Myeong;Kim, Ye-Rin;Kim, Heung-Geun;Jung, Jae-Jung
    • Proceedings of the KIPE Conference
    • /
    • 2020.08a
    • /
    • pp.336-337
    • /
    • 2020
  • Static synchronous compensator(STATCOM)은 무효전력을 공급하여 외란을 완화하는 등 전력 품질을 향상시켜 전력 계통을 안정화하는 시스템이다. Cascaded H-bridge(CHB) 컨버터는 멀티레벨 구조를 가지므로 STATCOM 시스템 적용에 많은 이점이 있다. 하지만, 이러한 멀티레벨 CHB 컨버터의 안정적인 동작을 위해서는 균형 제어가 필수적이다. 본 논문에서는 Y 결선 CHB 컨버터의 레그 에너지 균형 제어에 사용되는 주입 영상분 전압에 대하여 분석하고 균형 제어의 동특성 향상을 위한 전향 보상 계산 방법을 제안하였다. 제안한 방법을 적용하여 부하 불평형뿐만 아니라 계통 사고로 인한 계통 및 부하 동시 불균형에서도 안정적으로 시스템을 동작할 수 있다. 마지막으로 제안한 방법에 대한 수학적 타당성을 제시하고, 50MVA의 실제 스케일의 시뮬레이션을 통해 제안하는 방법을 검증하였다.

  • PDF

Light-load Efficiency Optimization Control Strategy for Active Clamp Forward Converter (액티브 클램프 포워드 컨버터에 적용 가능한 경부하 효율 최적화 제어 기법)

  • Kim, Dongmin;Lee, Young-Dal;Kim, Chong-Eun;Moon, Gun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2020.08a
    • /
    • pp.142-144
    • /
    • 2020
  • 본 논문은 액티브 클램프 포워드 컨버터(ACFC)에 적용 가능한 경부하 조건 효율 최적화 제어 기법을 제안한다. 기존의 액티브 클램프 포워드 컨버터는 경부하 조건에서 과도한 프리휠링 전류로 인해 큰 도통 손실이 발생하여 높은 효율을 기대하기가 어렵다. 제안하는 제어 방식은 복잡한 추가 회로 없이도 전도 손실을 줄이면서 경부하 효율을 유의미하게 개선할 수 있다. 제안하는 제어 방식의 실현 가능성 및 성능은 범용 AC 입력 및 65W 최대 출력에서 설계된 USB PD 어댑터 프로토타입 회로 구성을 통하여 실험 검증된다.

  • PDF

A New Synchronous Rectifier Control Method for High Efficiency Phase-Shifted Full-Bridge Converter with Coupled Inductor Rectifier (고효율 결합 인덕터 정류단 위상천이 풀브릿지 컨버터를 위한 새로운 동기정류기 제어 기법)

  • Kim, Jae-Sang;Kim, Keon-Woo;Moon, Gun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2020.08a
    • /
    • pp.145-147
    • /
    • 2020
  • 본 논문에서는, 결합 인덕터 정류단을 갖는 위상천이 풀브릿지 컨버터에 적용할 수 있는 새로운 동기정류기 제어 기법을 제안한다. 결합 인덕터 정류단을 활용하면 1차측 환류 전류를 감소 시켜 도통 손실을 줄일 수 있지만, 동시에 줄어든 전류로 인하여 레깅-레그 스위치의 영전압 스위칭을 달성하기 어려워진다. 이를 해결하기 위하여 변압기의 자화 전류를 이용할 수 있지만, 컨버터가 넓은 출력 전압 범위로 설계되는 경우 낮은 시비율을 기준으로 작게 설계된 자화 인덕턴스로 인하여, 높은 시비율로 구동 시 과도한 자화 전류로 인한 불필요한 도통 손실이 증가하는 문제점을 갖는다. 제안하는 제어 기법은 기존 동기정류기 제어와 달리 동기정류기를 기존보다 먼저 구동시켜 1차측에 환류 전류를 순간적으로 재생성할 수 있고, 이를 이용하여 레깅-레그 스위치의 영전압 스위칭을 달성할 수 있다. 따라서, 작은 자화 전류로 영전압 스위칭을 달성할 수 있으므로 1차측의 도통 손실을 줄여 높은 효율을 얻을 수 있다. 제안하는 동기정류기 제어 기법의 효용성을 증명하기 위하여, 400V 입력, 27-54V/13A 출력에서 실험 검증을 진행하였다.

  • PDF

A Study on the Internal Loss and Efficiency Analysis by Loss Factors in PFC Switching Rectifier (PFC 스위칭 정류기에서 손실인자에 의한 내부손실과 효율분석에 관한 연구)

  • Tae Young Ahn
    • Journal of the Semiconductor & Display Technology
    • /
    • v.23 no.2
    • /
    • pp.50-54
    • /
    • 2024
  • In this paper, we propose a theoretical method to systematically analyze the power conversion efficiency of a single-phase PFC switching rectifier. Boost-type PFC was organized in order of highest correlation with load current using steady-state analysis results and introduced the concept of loss factor. The loss factors for each major element are summarized and presented in a table. This paper makes it easier to understand the internal loss and power conversion efficiency of the rectifier for loss factors. Lastly, to confirm the validity of the efficiency analysis results reflecting the loss factors, loss and efficiency analysis of the 2.5kW PFC rectifier was performed. The results were compared with data from a 2.5kW PFC circuit for evaluation. As a result, the usefulness of power conversion efficiency analysis reflecting the loss factors proposed in this paper was confirmed.

  • PDF

Multi Remote Control of Ship's Emergency Lighting Power Supply (선박 비상조명 전원장치의 다중 원격제어)

  • Lee Sung-Geun;Lim Hyun-Jung
    • Journal of Navigation and Port Research
    • /
    • v.29 no.10 s.106
    • /
    • pp.859-863
    • /
    • 2005
  • This paper describes the improvement of power control characteristics of ship's emergency lighting power supply(SELPS), by which electric power is controlled extensively, and power ON-OFF is controlled and system parameter monitored in remote distance by PC serial communication. Proposed system is composed of step-down converter(SDC), emergency power supply circuit(EPSC), half bridge(HB) inverter, fluorescent lamp(FL) starting circuit, microprocessor control and multi communication circuit. Experimental works confirm that relative system stops when over current is detected and speedy and stable emergency power is supplied when main power source cut-off, and controls input power up to 35[$\%$] by adjusting pulse frequency of the HB inverter, and ON-OFF control of multiple SELS, real time transmission and monitor of parameters as to voltage, current, and power values are performed appropriately by PC communication.

MPPT Control of PV Water Pumping Using BLDC Motor-Inverter (BLDC 모터용 인버터를 이용한 PV 양수펌프의 MPPT 제어)

  • 김성남;백승길;조정민;이승환;오봉환;이훈구;한경희
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.6
    • /
    • pp.498-505
    • /
    • 2001
  • This paper shows how to design a global control of water pumping system using PV array, and tracked maximum power point of PV array only the inverter using the vector control of BLDC motor, and finding the relationships among the DC magnitudes and AC ones in order to omit the DC/DC converter. Conventional MPPT controller was unstable of reason of the ripple-current of DC link in three-phase invertor. Thus, in this paper the control algorithm of BLDC motor using $i_qs$ current is composed to improve the insecurity of conventional MPPT controller To prove the excellence of the proposed method, the contents of this paper is analyzed by means of simulation and testing for the results applying the method that J. A Domfnguez had applied to asynchronous motor to BLDC motor and that of the proposed method in this paper.

  • PDF

DC-Link Voltage Unbalancing Compensation of Four-Switch Inverter for Three-Phase BLDC Motor Drive (3상 BLDC 전동기 구동을 위한 4-스위치 인버터의 DC-Link 전압 불평형 보상)

  • Park, Sang-Hoon;Yoon, Yong-Ho;Lee, Byoung-Kuk;Lee, Su-Won;Won, Chung-Yuen
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.391-396
    • /
    • 2009
  • In this paper, a control algorithm for DC-Link voltage unbalancing compensation of a four-switch inverter for a three-phase BLDC motor drive is proposed. Compared with a conventional six-switch inverter, the split source of the four-switch inverter can be obtained by splitting DC-link capacitor into two capacitors to drive the three phase BLDC motor. The voltages across each of two capacitors are not always equal in steady state because of the unbalance in the impedance of the DC-link capacitors $C_1$ and $C_2$ or the variable current flowed into the capacitor's neutral point in motor control. Despite the unbalance, if the BLDC motor may be run for a long time the voltage across one of the capacitors is more increased. So the unbalance in the capacitors voltages will be accelerated. As a result, The current ripple and torque ripple is increased due to the fluctuation of input current which flows into 3-phase BLDC motor. According to that, the vibration of motor will be increased and the whole system will be instable. This paper presents a control algorithm for DC-Link voltage unbalancing compensation. The sampling from the voltages across each of two capacitors is used to perform the voltage control of DC-Link by using the feedforward controller.

Design and Implementation of Progress Management System Using Swing Component Based on Internet (Swing 컴포넌트를 이용한 인터넷 기반 공정관리시스템 설계와 구현)

  • Kim, Tai-Suk;Kim, Jong-Soo
    • Journal of Korea Multimedia Society
    • /
    • v.13 no.8
    • /
    • pp.1163-1170
    • /
    • 2010
  • In this paper, in order to develop a remote progress management system through the Internet, we show a design method to make easy maintenance by developing the system with both the JAVA language and GoF Design Patterns. For the system implementation, we added the RS232C and RS422/RS485 communication modules to PLC(Programmable Logic Controller) in the control box which provide the real time status data of machines. Also we set up the RS232C to Ethernet converter based on wireless environment to communicate the PLC control data. We use JAVA Swing components to implement the multi-tier architecture system supported the GUI of the Applet and Frame at the same time so that the manager grasps the progress of work easily at the remote machines through the Internet. The key objective of the multi-tier architecture is to share resources among clients, this proposed system can help to develop the software to control the remote machine, and also it has the advantage that developer who wants to make a similar software can make easy to add new function reusing the existing codes.

The Feed-forward Controller and Notch Filter Design of Single-Phase Photovoltaic Power Conditioning System for Current Ripple Mitigation (단상 PVPCS 출력 전류의 리플 개선을 위한 노치 필터 및 피드 포워드 제어기 설계)

  • Kim, Seung-Min;Yang, Seung-Dae;Choi, Ju-Yeop;Choy, Ick;Lee, Young-Gwon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.325-330
    • /
    • 2012
  • A single-phase PVPCS(photovoltaic power conditioning system) that contains a single phase dc-ac inverter tends to draw an ac ripple current at twice the out frequency. Such a ripple current may shorten passive elements life span and worsen output current THD. As a result, it may reduce the efficiency of the whole PVPCS system. In this paper, the ripple current propagation is analyzed, and two methods to reduce the ripple current are proposed. Firslyt, this paper presents notch filter with IP voltage controller to reject specific current ripple in single-phase PVPCS. The notch filter can be designed that suppress just only specific frequency component and no phase delay. The proposed notch filter can suppress output command signal in the ripple bandwidth for reducing output current THD. Secondly, for reducing specific current ripple, the other method is feed-forward compensation to incorporate a current control loop in the dc-dc converter. The proposed notch filter and feed-forward compensation method have been verified with computer simulation and simulation results obtained demonstrate the validity of the proposed control scheme.

  • PDF