• Title/Summary/Keyword: Conversion loss

Search Result 737, Processing Time 0.024 seconds

Feasibility Study on Modified OTEC (Ocean Thermal Energy Conversion) by Plant Condenser Heat Recovery (발전소 복수기 배열회수 해양온도차 발전설비 적용타당성 검토)

  • Jung, Hoon;Kim, Kyung-Yol;Heo, Gyun-Young
    • New & Renewable Energy
    • /
    • v.6 no.3
    • /
    • pp.22-29
    • /
    • 2010
  • The concept of Ocean Thermal Energy Conversion (OTEC) is simple and various types of OTEC have been proposed and tried. However the location of OTEC is limited because OTEC requires $20^{\circ}C$ of temperature difference as a minimum, so most of OTEC plants were constructed and experimented in tropical oceans. To solve this we proposed the modified OTEC which uses condenser discharged thermal energy of existing fossil or nuclear power plants. We call this system CTEC (Condenser Thermal Energy Conversion) as this system directly uses $32^{\circ}C$ partially saturated steam in condenser instead of $20{\sim}25^{\circ}C$ surface sea water as heat source. Increased temperature difference can improve thermal efficiency of Rankine cycle, but CTEC should be located near existing plant condenser and the length of cold water pipe between CTEC and deep cold sea water also increase. So friction loss also increases. Calculated result shows the change of efficiency, pumping power, net power and other parameters of modeled 7.9 MW CTEC at given condition. The calculated efficiency of CTEC is little larger than that of typical OTEC as expected. By proper location and optimization, CTEC could be considered another competitive renewable energy system.

Characteristic of Three-Phase Voltage Type Soft-Switching Inverter using the Novel Active Auxiliary Resonant DC Link Snubber (새로운 액티브 보조 공진 DC 링크 스너버를 이용한 3상 전압형 소프트 스위칭 인버터의 특성)

  • Sung, Chi-Ho;Heo, Young-Hwan;Mun, Sang-Pil;Park, Han-Seok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.2
    • /
    • pp.114-121
    • /
    • 2016
  • This paper is Instant space vector PWM(Pulse Width Modulation)power conversion devices in switching power semiconductors from my generation to losses and switching when the voltage surge and current surge of electronic noise(EMI: Electro Magnetic Interference / RFI: Radio Frequency Interference)to effectively minimize the power soft-switching power conversion circuit topologies of auxiliary resonant DC tank for the purpose of high performance realization of the electric power conversion system by the high-speed switching of a semiconductor device(AQRDCT simultaneously : an active auxiliary resonance using auxiliary Quasi-resonant DC tank)DC link snubber switch has adopted a three-phase voltage inverter. AQRDCL proposed in this paper can reduce the effective and current peak stress of the power semiconductors of the auxiliary resonant snubber circuit compared to the conventional active-resonant DC link snubber, it is not necessary to install the clamp switch of the auxiliary resonant DC link, DC the peak current and power loss of the bus line can be reduced.

The Study on Electrocardiographic Changes after Mitral Valvular Replacement (승모판막 수술에 따른 심전도 변화)

  • Yeo, Seung-Dong;Im, Seung-Pyeong
    • Journal of Chest Surgery
    • /
    • v.24 no.4
    • /
    • pp.421-427
    • /
    • 1991
  • Atrial fibrillation[Af] is closely related to thrombus in left atrium, systemic embolism, and loss of the contribution of atrial contraction to cardiac output. Therefore maintenance of sinus rhythm[SR] is undoubtedly hemodynamically superior to Af in the clinical course of mitral valvular disease especially in the unstable period immediately after surgery. In this article, the conversion rate and the factors influencing the conversion of Af to SR after surgery were studied. Ninety-three patients with mitral valvular replacement at Chungnam National University Hospital were analysed with electrocardiography before and after surgery during the period from June 1985 to June 1990. Eighty patients presented Af before surgery. Twenty-four[30Yo] of the patients were converted to SR[A group] and fifty six presented continuous Af after surgery[B group]. The duration of preoperative Af, preoperative left atrial dimension[LAD], preoperative functional status[NYHA classification] and cardiothoracic[CT] ratio were factors influencing the conversion of Af to SR after surgery. The mean preoperative duration of Af was 3.5$\pm$2.6yr in group A and 7.6$\pm$4.9yr in group B. The mean preoperative LAD was 53. 7$\pm$9.4mm in group A and 62.5$\pm$11.2mm in group B. Before surgery, eleven patients[46%] were belong to NYHA class I, II in group A and eight[14%] in group B. The preoperative CT ratio was 62$\pm$6% in group A and 69$\pm$8% in group B.

  • PDF

The Characteristics of Planar EMI Filter with Bi-Ground Layers Considering Impedance Mismatching

  • Wang, Shishang;Song, Zheng;Lou, Qianceng
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.1200-1208
    • /
    • 2016
  • Planar electromagnetic interference (EMI) filter has significant engineering significance to power electronic system integration and miniaturization. However, the value of differential mode capacitance cannot meet the demand of noise suppression because of the size limit of ceramics. In this case, the EMI filter of novel multilayers is recommended to address this issue. A novel integrated structure of EMI filter based on multilayer ceramic is proposed in this study. The inductance and capacitance of the new structure can be designed separately, which is an advantage in manufacturing. Insertion loss is measured more closely to the actual situation in this study, which is different from the condition where source and load impedances are both 50 Ω. In the process of designing a novel EMI filter, noise impedance is considered. Moreover, the prototype is created and applied to a small switching power supply, which verifies the effectiveness of the developed EMI filter.

Efficiency Improvement with $Al_2O_3/SiN_x$ Rear Passivation of p-type Mono-crystalline Silicon Solar Cells ($Al_2O_3/SiN_x$ 후면 적층 패시베이션을 이용한 결정질 실리콘 태양전지의 효율 향상 연구)

  • Cheon, Joo Yong;Beak, Sin Hey;Kim, In Seob;Chun, Hui Gon
    • Journal of the Semiconductor & Display Technology
    • /
    • v.12 no.3
    • /
    • pp.47-51
    • /
    • 2013
  • Current research trends of solar cells has focused on the high conversion efficiency and low-cost production technology. Passivation technology that can be easily adapted to mass production. Therefore, this study conducted experiments with aim of the following two methods for the fabrication of high-efficiency crystalline silicon solar cells. In the first task, an attempt is formation of local Al-BSF to a number of locally doped dots to increase the conversion efficiency of solar cells to reduce the loss of $V_{oc}$ overcome. The second major task, rear surface apply in $Al_2O_3/SiN_x$ stack layer, $Al_2O_3$ prominent negative fixed charge characteristics. As the result of task, Local Al-BSF and $Al_2O_3/SiN_x$ stack layer applied to the p-type single crystalline silicon solar cells, the average $V_{oc}$ of 644mV, $I_{sc}$ of 918mV and conversion efficiency of 18.70% were obtained.

Characteristics of DC 48[V] telecommunication power supply (DC 48[V] 통신용 전원 장치의 특성)

  • Jung, H.T.;Jo, M.C.;Youn, Y.T.;Kim, J.Y.;Mun, S.P.;Suh, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2462-2464
    • /
    • 2005
  • The AC-DC converter, which has three-phase AC power as input and isolated DC power as output is used for the regulated DC power supply of the telecommunication power processing system for several kilowatt class applications. The conventional DC power supply for the telecommunication power system comprises a PWM rectifier with sine-wave shaping input current unity power factor and a DC/DC converter connected to the PWM converter, which obtains DC 48[V]. Since power passes through these two power stage converters, the conversion power loss is difficult to provide high efficiency. To resolve these problems, this paper presents a new PWM rectified as a 1-stage power conversion method. It simulation and experimental results as proved from a Practical point of view that 92.1[%]of conversion efficiency and input current which can meet harmonics regulation of the Class-A in IEC61000-3-3 are achieved.

  • PDF

Characteristics of DC 48[V] telecommunication power supply (DC 48[V] 통신용 전원 장치의 특성)

  • Jung, H.T.;Jo, M.C.;Youn, Y.T.;Kim, J.Y.;Mun, S.P.;Suh, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1820-1822
    • /
    • 2005
  • The AC-DC converter, which has three-phase AC power as input and isolated DC power as output is used for the regulated DC power supply of the telecommunication power processing system for several kilowatt class applications. The conventional DC power supply for the telecommunication power system comprises a PWM rectifier with sine-wave shaping input current unity power factor and a DC/DC converter connected to the PWM converter, which obtains DC 48[V]. Since power passes through these two power stage converters, the conversion power loss is difficult to provide high efficiency. To resolve these problems, this paper presents a new PWM rectified as a 1-stage power conversion method. It simulation and experimental results as proved from a practical point of view that 92.1[%]of conversion efficiency and input current which can meet harmonics regulation of the Class-A in IEC61000-3-3 are achieved.

  • PDF

Construction and Testing of a radiation-beam powered TA (ThermoAcoustic) washer for grease removal

  • Chen, Kuan;DaCosta, David H.;Kim, Yeongmin;Oh, Seung Jin;Chun, Wongee
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.1
    • /
    • pp.21-28
    • /
    • 2015
  • A small washer powered directly and solely by thermal radiation was constructed and tested to explore the feasibility of using solar energy or other types of thermal radiation for washing and cleaning. In principle, TA (ThermoAcoustic) washers have the benefits of simpler design and operation and fewer energy conversion processes, thus should be more energy efficient and cost less than electric washing/cleaning systems. The prototype TA converter we constructed could sustain itself with consistent fluid oscillations for more than 20 minutes when powered by either concentrated solar radiation or an IR (infrared) heater. The frequencies of water oscillations in the wash chamber ranged from 2.6 to 3.6 Hz. The overall conversion efficiency was lower than the typical efficiencies of TA engines. Change in water temperature had little effect on the oscillatory flow in the TA washer due to its low efficiency. On the other hand higher water temperatures enhanced grease removal considerably in our tests. Methods for measuring the overall conversion efficiency, frictional loss, and grease removal of the TA washing system we designed were developed and discussed.

ECONOMIC ANALYSIS BY GLASS TYPES IN BALCONY CONVERSION OF MULTI-FAMILY HOUSING PROJECTS

  • H.G. Kim;D.I. Kim;D.W. Ko;T.H. Hong;C.T. Hyun;K.J. Koo
    • International conference on construction engineering and project management
    • /
    • 2007.03a
    • /
    • pp.625-634
    • /
    • 2007
  • Energy-saving is one of important issues in multi-family housing projects in South Korea. According to the study by Yu et al. (2002), the balcony conversion causes energy loss approximately one and a half times. Therefore, it is important to select the economical glass type in the balcony window. In order to identify the most economical glass type of balcony conversion in multi-family housing projects, the most typical type of the multifamily housing projects in the metropolitan area was selected as a candidate project. The selected candidate project has been simulated using ENERGY-10 program to estimate the heat load by the different five types of glasses as well as their life cycle cost analysis (LCCA) using present worth method. Finally, sensitivity analysis has been conducted to determine the most economical glass types under a different discount rate (interest rate) and service life of building.

  • PDF

A Study on the Conversion Condition of Shallow Water 3-layered Model into 2-layered Model with Correlation (상관관계를 이용한 천해 3층모델의 2층 모델로의 전환조건에 대한 연구)

  • Kim, Young-Sun;Kim, Sung-Boo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.2
    • /
    • pp.92-101
    • /
    • 2008
  • To dissolve the multi-layered model problems, and to complement 2-layered model's simplicity, assumed fluid-fluid-solid 3-layered model. Generally it is known that if the sediment thickness is more than 10 wavelength, the half space's influence to the in-water acoustic field could be disregarded. By tracking the maximum correlation coefficient of calculated results and experimental ones we confirmed that the requirement could be more realized. To calculate the maximum correlation coefficient we used single sensor transmission loss. On the assumption that the sediment sound velocity was 1813 m/s and frequency range 50 kHz to 120 kHz, the conversion condition was from 2.5 to 7.7 wavelength.