• Title/Summary/Keyword: Conversion Type

Search Result 1,376, Processing Time 0.027 seconds

Antisymmetric-Symmetric Mode Conversion of Ultrasonic Lamb Waves and Negative Refraction on Thin Steel Plate

  • Sung, Jin Woo;Kim, Young H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.3
    • /
    • pp.270-275
    • /
    • 2013
  • In this study, focusing of ultrasonic Lamb wave by negative refraction with mode conversion from antisymmetric to symmetric mode was investigated. When a wave propagates backward by negative refraction, the energy flux is antiparallel to the phase velocity. Backward propagation of Lamb wave is quite well known, but the behavior of backward Lamb wave at an interface has rarely been investigated. A pin-type transducer is used to detect Lamb wave propagating on a steel plate with a step change in thickness. Conversion from forward to backward propagating mode leads to negative refraction and thus wave focusing. By comparing the amplitudes of received Lamb waves at a specific frequency measured at different distance between transmitter and interface, the focusing of Lamb wave due to negative refraction was confirmed.

Power Conversion System and Technical Trend of Fuel Cell Electric Vehicles (FCEV용 전력변환장치와 FCEV의 기술동향)

  • Choi U. D.;Min B. D.;Lee J. C.;Kim J. C.;Lee J. P.
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.593-597
    • /
    • 2002
  • The power conversion system for Fuel Cell Electric Vehicle(FCEV), technical trend, and a various type of Fuel Cell and its characteristics are presented. Especially, this paper is focused on the control methods of power conversion devices applied for the Fuel Cell Electric Vehicle, configuration of power system and operation mode of the bidirectional DC/DC converter. The prevalent topology for the power conversion systems, simulation results and development a tendency of FCEV and it's market investigations are introduced.

  • PDF

Synthesis of Fe-Mn Bimetallosilicate and Its Catalytic Performance on NO Decomposition

  • Kang, Misook
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.E
    • /
    • pp.9-16
    • /
    • 1999
  • This study has been focused on NO conversion for metal-incorporated silicates(Fe-silicate, Mn-silicate, and Fe-Mn-bimetallosilicate) with a similar MFI type. Used metallosilicates were prepared by the rapid crystallization method. Their catalytic performance for the conversion of NO under excess O2(10%) condition with the addition of hydrocarbon of low concentration(1,100ppm n-C8H18) were investigated. As a result, the NO conversion on the Fe-Mn-bimetallosilicate was enhanced compared with on the Fe- or Mn-silicates. Furthermore, the performances for NO concentration on Fe-Mn-bimetallosilicate more increased with an increased in n-C8H18 concentration, a decrease in NO concentration, and an increase in O2 concentration.

  • PDF

A study on the RF-DC Conversion Efficiency of Microstrip Patch Rectenna (Microstrip Patch 형 Rectenna의 변환효율 분석에 관한 연구)

  • Park, Yang-Ha;Youn, Dong-Gi;Kim, Kwan-Ho;Rhee, Young-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2177-2179
    • /
    • 2000
  • We designed and manufactured micros trip patch antenna mainly used in the Rectenna and then analysed RF-DC conversion efficiency of wireless power transmission system. We analyse conversion efficiency of load, direction of linear and dual polization rectenna. We found that the maximum efficiency would be about 70% of load and direction in patch type. In conclusion, we found that total conversion efficiency is 64%$\sim$71% in patch Rectenna.

  • PDF

Wire Electric Discharge Machining Process of Various Crystalline Silicon Wafers (다양한 실리콘 웨이퍼 제조를 위한 와이어 전기 방전가공)

  • Moon, Hee-chan;Choi, Sun-ho;Park, Sung-hee;Jang, Bo-yun;Kim, Jun-soo;Han, Moon-hee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.5
    • /
    • pp.301-306
    • /
    • 2017
  • Wire electrical discharge machining (WEDM) process was evaluated to slice Silicon (Si) for various applications. Specifically, various Si workpieces with various resistances, such as single and multi crystalline Si bricks and wafers were used. As conventional slicing processes, such as slurry-on or diamond-on wire slicing, are based on mechanical abrasions between Si and abrasive, there is a limitation to decrease the wafer thickness as well as kerf-loss. Especially, when the wafer thickness is less than $150{\mu}m$, wafer breakage increases dramatically during the slicing process. Single crystalline P-type Si bricks and wafers were successively sliced with considerable slicing speed regardless of its growth direction. Also, typical defects, such as microcracks, craters, microholes, and debris, were introduced when Si was sliced by electrical discharge. Also, it was found that defect type is also dependent on resistance of Si. Consequently, this study confirmed the feasibility of slicing single crystalline Si by WEDM.

The Effect of Promoters Addition on NOx Removal by $NH_3$ over V$V_2O_5/TiO_2$

  • Lee, Keon-Joo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.E1
    • /
    • pp.29-36
    • /
    • 2002
  • The selective catalytic reduction (SCR) reaction of promoter catalysts was investigated in this study. A pure anatase type of TiO$_2$ was used as support. Activation measurement of prepared catalysts was practiced on a fixed reactor packing by the glass bead after filling up catalysts in 1/4 inch stainless tube. The reaction temperature was measured by K-type thermocouple and catalyst was heated by electric furnace. The standard compositions of the simulated flue gas mixture in this study were as follows: NO 1,780ppm, NH$_3$1,780ppm, $O_2$1% and $N_2$ as balance gas. In this study, gas analyzer was used to measure the outgassing gas. Catalyst bed was handled for 1hr at 45$0^{\circ}C$, and the reactivity of the various catalyst was determined in a wide temperature range. Conversion of NH$_3$/NO ratio and of $O_2$ concentration was practiced at 1,1.5 and 2, respectively. The respective space velocity were as follows . 10,000, 15,000 and 17,000 hr-1. It was found that the maximum conversion temperature range was in a 5$0^{\circ}C$. It was also found toi be very sensitive at space velocity, $O_2$ concentration, and NH$_3$/NO ratio. We also noticed that the maximum conversion temperature of (W, Mo, Sn) -V$_2$O$_{5}$/TiO$_2$ catalysts was broad. Specially WO$_3$-V$_2$O$_{5}$TiO$_2$2 catalyst appeared nearly 100% conversion at not only above 30$0^{\circ}C$ ut also below 25$0^{\circ}C$. At over 30$0^{\circ}C$, NH$_3$ oxidation decreased with decrease of surface excess oxygen. In addition, WO$_3$-V$_2$O$_{5}$TiO$_2$ catalyst did not appear to affect space velocity, $O_2$ concentration, and NH$_3$/NO ratio.ratio.

An Observation on Bacteriological Conversion of Lapromatous Leprosy Cases Treated by Antileprosy Mobile Service (이동진료반(移動診療班) 치료(治療)에 의(衣)한 나종양환자(癩腫樣患者)의 균음전(菌陰轉)에 관(關)한 관찰(觀察))

  • Han, In-Soo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.7 no.2
    • /
    • pp.313-318
    • /
    • 1974
  • An observation on bacteriological conversion upon 56 bocteriological positives out of 131 cases of lepromatous leprosy treated by antileprosy morbile service was carried out. Those 131 lepromatous cases were a part of 335 total registered from three Guns of Gangjin, Hwa sun, and Goheung, Cheollanamdo, since 1957 to 1973 that has been under the control of antileprosy morbile unit. The results obtained are summalized as follows, 1. Lepromatous type was 36.9% of all cases. The ratio of male to female was 4.9 to 1. Age between 30-44, the most productive ages, occupied 38.0% and age over 60 occupied 18.0% of all. 2. 42.7% of lepromatous type was bacteriological positive. 43.1% was for male and 43.1% was for female. Age between 20 to 24 shown the highest positive at 63.7% and followed by aged over 60 (62.5%) and under 19 (60.0%). The lowest one was seen at age between 40 to 44 at 29.2%. 3. Bacteriological positive rate at registration was different in accordance with duration of treatment received befor registration. It came up to the highest 100.0% at the group treated one year before registration. That of the group not received any treatment was 56.4%, and the group received 4-5 years was the lowest at 26.1% 4. Bacteriological conversion rate was 44.6% and 14.3% of all positive casese regressed in bacterial number. 37.5% of all active cases converted bacteriologically within 5 years. 5. Bacteriological conversion rate in group received 1 year treatment before registattion was 66.6%. That in group not received any treatment was 31.8% and group received 4-5 years was 33.3%. 6. Considering of total duration reaseved treatment together with before and after registration, 33.9% of all active cases resulted bacteriological conversion or regression within 5 years.

  • PDF

A Study on Feasibility Analysis and Optimum Range Calculation Model by Conversion of Water Supply System (상수도 급수방식 전환의 타당성 분석 및 최적 범위 산정모델 연구)

  • Park, Junyeol;Shin, Hwisu;Seo, Jeewon;Kim, Kibum;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.2
    • /
    • pp.177-186
    • /
    • 2017
  • This study concerned the analysis on the efficiency of the conversion of water tank type supply system to direct water supply system to examine the feasibility of the conversion, as well as the calculation of optimal conversion range that enables the supply of safe, high-quality water at stable pressure in accordance with the standards of water supply facility. The results of this research showed that when converting water supply system from water tank type supply system to direct water supply system, more nodal points could be properly converted and more reduction of electricity usage was expected in case water pressure rather than residence time was fixed. This means that higher efficacy can be obtained by fixing water pressure when converting water supply system. However, since the number of the locations that received on-spot inspection was small and the electricity usage measured was not exclusively by water supply facility, it is difficult to judge that such reduction of electricity usage accurately represents reduced electricity usage by water supply facility alone. therefore, after having secured on-spot information about a larger number of locations in apartment complexes that have converted water supply system, and utilizing information about electricity usage exclusively by water supply facility, the proposed method of this research could be applied to accurately deducing expected reduction of electricity usage by water supply facilities of various other apartment complexes. It is also considered possible to deduce an effective operation method of water supply system by finding out an area that shows low pressure or low residual chlorine concentration in the optimal conversion range of water supply, followed by estimating the proper location of pumping station or the proper chlorine dosage at the power purification plant that supply water to the target area.

A Study on the Development of Defense Performance Specification and Conversion into it (국방 성능형 규격 작성 및 전환 방안에 관한 연구)

  • Choi, Seok-Cheol;Song, Yu-Ha
    • Journal of the military operations research society of Korea
    • /
    • v.33 no.1
    • /
    • pp.135-155
    • /
    • 2007
  • A performance specification states requirements in terms of the required results, such as performance, environment and interchangeability, but without stating the methods for achieving the required results, such as material and process. therefore the performance specification is applied to attain economic efficiency and high reliability by using the advanced commercial Technology for the weapon systems and The development of performance specification and conversion into performance specification have been activated in the advanced nations. The Ministry of National Defence of Korea has regulated the specification to make performance type in developing specification and prepared performance specification guide. but the result of the development of and conversion into performance specification is very unsatisfactory, To efficiently develop and convert into performance specification, this study gives the way of market research, the creation of the performance specification from development of weapon system and part localization, the process and method for conversion of detail specification into performance specification, the use of hybrid type of performance and detail specification.

The Performance & Operation Analysis of a Plate Type Reformet for 2 kW Class MCFC Stack (2 kW급 MCFC용 평편형 개질기 운전결과)

  • Seo, Hal-Kung;Ahn, Kyo-Sang;Lim, Hee-Chun;Lee, Sang-Deuk
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.13 no.2
    • /
    • pp.159-167
    • /
    • 2002
  • The operation results of the 2kW class plate type reformer, which has several advantages compared with the tubular burner type reformer, are analyzed. This plate type reformer is composed of six combustion chambers and five reforming chambers by turns. The methane conversion rate at 1.6 absolute pressure is about 84%, which is reasonably similar to theoretical value, 85.3%. Though the abrupt interruption was made just by the carbon deposition during heating the fuel line to combustion chambers around 200 hours operation, the overall steady state operation is more than 450 hours. These operation results show the verification of long run performance and the possibility of direct connection between plate reformer and fuel cell stack.