• Title/Summary/Keyword: Conversion Factor

Search Result 970, Processing Time 0.035 seconds

Nitrogen Conversion Factors and in vitro Protein Digestibility of some Seaweeds (수종해조의 단백계수와 in vitro Digestibility)

  • Ryu Hong-Soo;SATTERLEE Lowell D.;LEE Kang-Ho
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.15 no.4
    • /
    • pp.263-270
    • /
    • 1982
  • In an attempt to evaluate the nutritional quality of seaweed protein, the effects of heat treatment on the in vitro digestibility and trypsin inhibitor content in seaweed were determined. In this study, the nitrogen-to-protein conversion factors were also calculated on the basis of quantitative amino acid data. The results are as follows : 1. The in vitro protein digestbilty of red seaweeds (P. teoera anc P. suborbiculata) were ranged from 78.5 to 82.2, and green seawerd (E. linza) and brown seaweeds showed value under 80 in vitro digestibility. In general, trypsin inhibitor contents in brown seaweed were higher (0.33-0.54 mg/g) than those of red seaweeds (0.26-0.39 mg/g). And it is noted that the lowest trypsin inhibitor content was shown in green seaweed (E. linza) in spite of lowest in spite digestibility (78.5). 2. The in vitro protein digestibility of sun dried laver (P. tenera) was increased with cooling time (microwave heating), but it was not significant. Hot plate cooking raised the in vitro digestibility from 81. 1 to 84.5. The influence pot cooking time on trypsin inhibitor content was inversely proportional to in vitro digestibility. 3. Computed nitrogen factor, based on amino acid content (Factor method) and Kjeldahl nitrogen content (Kjeldahl mettled), were 5.83 (H. fusiforme)- 6.52 (P. tencra) as Factor method and 5.40 (U. pinnatifida)-6.29 (P. tenera) as Kjeldahl method. Individual value for each nitrogen conversion factor differed by species, especially in brown seaweeds. The best estimate of the protein content of seaweed can be calculated, from multiplying the summed amino acid content by conversion factor (Factor method).

  • PDF

ABSORBED INTERNAL DOSE CONVERSION COEFFICIENTS FOR DOMESTIC REFERENCE ANIMALS AND PLANT

  • Keum, Dong-Kwon;Jun, In;Lim, Kwang-Muk;Choi, Yong-Ho
    • Nuclear Engineering and Technology
    • /
    • v.42 no.1
    • /
    • pp.89-96
    • /
    • 2010
  • This paper describes the methodology of calculating the internal dose conversion coefficient in order to assess the radiological impact on non-human species. This paper also presents the internal dose conversion coefficients of 25 radionuclides ($^3H,\;^7Be,\;^{14}C,\;^{40}K,\;^{51}Cr,\;^{54}Mn,\;^{59}Fe,\;^{58}Co,\;^{60}Co,\;^{65}Zn,\;^{90}Sr,\;^{95}Nb,\;^{99}Tc,\;^{106}Ru,\;^{129}I,\;^{131}I,\;^{136}Cs,\;^{137}Cs,\;^{140}Ba,\;^{140}La,\;^{144}Ce,\;^{238}U,\;^{239}Pu,\;^{240}Pu$) for domestic seven reference animals (roe deer, rat, frog, snake, Chinese minnow, bee, and earthworm) and one reference plant (pine tree). The uniform isotropic model was applied in order to calculate the internal dose conversion coefficients. The calculated internal dose conversion coefficient (${\mu}Gyd^{-1}$ per $Bqkg^{-1}$) ranged from $10^{-6}$ to $10^{-2}$ according to the type of radionuclides and organisms studied. It turns out that the internal does conversion coefficient was higher for alpha radionuclides, such as $^{238}U,\;^{239}Pu$, and $^{240}Pu$, and for large organisms, such as roe deer and pine tree. The internal dose conversion coefficients of $^{239}U,\;^{240}Pu,\;^{238}U,\;^{14}C,\;^3H$, and $^{99}Tc$ were independent of the organism.

Balanced Forward-Flyback Converter for High Efficiency and High Power Factor LED Driver (고효율 및 고역률 LED 구동회로 위한 Balanced Forward-Flyback 컨버터)

  • Hwang, Min-Ha;Kang, Jeong-Il;Han, Sang-Kyoo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.492-500
    • /
    • 2013
  • A balanced forward-flyback converter for high efficiency and high power factor using a foward and flyback converter topologies is proposed in this paper. The conventional AC/DC flyback converter can achieve a good power factor but it has the high offset current through the transformer magnetizing inductor, which results in a large core loss and low power conversion efficiency. And, the conventional forward converter can achieve the good power conversion efficiency with the aid of the low core loss but the input current dead zone near zero cross AC input voltage deteriorates the power factor. On the other hand, since the proposed converter can operate as the forward and flyback converters during switch turn-on and turn-off periods, respectively, it cannot only perform the power transfer during an entire switching period but also achieve the high power factor due to the flyback operation. Moreover, since the current balanced capacitor can minimize the offset current through the transformer magnetizing inductor regardless of the AC input voltage, the core loss and volume of the transformer can be minimized. Therefore, the proposed converter features a high efficiency and high power factor. To confirm the validity of the proposed converter, theoretical analysis and experimental results from a prototype of 24W LED driver are presented.

A Classification of Conversion Factors of Relative Values in the National Health Insurance (건강보험 환산지수의 유형별 분류방안)

  • Kim, Jin-Hyun;Choi, Byung-Ho
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.10 no.2
    • /
    • pp.147-158
    • /
    • 2006
  • The purpose of this paper is to review the empirical study results of conversion factors(unit prices) for relative values of health care services in the national health insurance system and establish optimal classification of health care institutions for feasible contract of conversion factors between National Health Insurance Corporation(NHIC) and provider groups, based on legal backgrounds and types of health care service delivery system. some empirical research evidences shows the validity of applying multiple conversion factors to annual contract for reimbursement in the national health insurance. Policy recommendations suggest that clinic, hospital, general hospital, tertiary hospital, dental clinic, oriental medical clinic, pharmacy, and public health centers would be a basic category of provider groups for a meaningful price contract between the NHIC and providers.

  • PDF

The Effect of Fit between Knowledge Conversion Preference and Job Character on Job Effectiveness (지식전환선호도와 직무특성이 직무유효성에 미치는 영향)

  • Ha Gab-Jin;Seong Jeong-Hyeon
    • Management & Information Systems Review
    • /
    • v.17
    • /
    • pp.161-189
    • /
    • 2005
  • As the importance of intellectual assets has been brought into relief, this study aims at positively verifying where the intellectual workers' overall level of their knowledge conversion preference and their job character has reached, and how much the knowledge conversion preference, the job character and the fitness of both factors affects the job effectiveness respectively. For this purpose 3 types of research hypotheses were set up and the result of the verification of the hypotheses is summarized as follows: First, the verification of the relation between the knowledge conversion preference and the job effectiveness revealed that the workers who have the higher synthetic ability in knowledge conversion preference show the higher job satisfaction and job product. Secondly, the verification of the relation between the MPS representing the job character by measured index and the job satisfaction revealed that the absolute value of relative coefficient between the 4 factors excluding the public welfare factor and the MPS is 4, interpreted as medium correlation. Thirdly, the analysis on the degree of relation between the job product measured by the quality of job result and the input effort and the MPS showed that the absolute value of person relative coefficient is 5, interpreted not only as medium correlation but also very meaningful. Accordingly, the main purpose of this study was to give a guideline which can be utilized as an indicator for educating, training and placing the workers. As results, the main effect that the variable of knowledge conversion preference and job character chosen as the independent variable influences on the dependent variable of job satisfaction and job product is very meaningful except the public welfare factor.

  • PDF

Analysis of Impedance Performance for Condenser by Harmonic Current Source (고조파 전류원에 의한 콘덴서 임피던스 특성 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.4
    • /
    • pp.57-64
    • /
    • 2011
  • Most of the user has been used linear load and non-linear load. The former is usually inductive load which is needed power factor compensation, the latter is power conversion system device. Actually two kinds of load is used together in the customer application. Generally capacitor is used for power-factor compensation of inductive load and reduction harmonics of non linear load with reactor. Non-linear load generates harmonic current for its energy conversion process. If harmonic current pass along the low impedance side of distribution system, the magnification of voltage and current is appeared by the series and parallel resonance. As a result, condenser has received a bitter electrical stress by the harmonic component. In this paper, we analyzed that how resonance is changed by the 5-th harmonic current pattern and proposed an alternative plan for non-magnification.

Organic Photovoltaic Devices on $HNO_3$-Treated Multilayer Graphene Electrodes

  • Jung, Yong Un;Na, Seok-In;Kim, Han-Ki;Kang, Seong Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.235-235
    • /
    • 2013
  • We reported on the characteristics of organic solar cells (OSCs) fabricated on $HNO_3$-treated multilayer graphene (MLG) transparent electrodes. MLG electrodes were prepared using a chemical vapor deposition and a multi-transfer process. Compared to organic solar cells (OSCs) on the ITO electrodes had a fill factor of 65.97%, and a power conversion efficiency (PCE) of 3.364%, OSCs on the MLG (three-layer graphene) electrodes with sheet resistance of $274{\pm}1{\Omega}$/square and transparency of 92.1% had a fill factor of 43.46%, and a power conversion efficiency (PCE) of 2.019%. However, OSCs on the HNO3-treated MLG electrodes with lower sheet resistance of $119{\pm}1{\Omega}$/square had a fill factor of 57.54%, and a PCE of 2.861%. The results would provide a promising method to improve the performance of large-area OSCs based on MLG electrodes.

  • PDF

COD Pollutants Load Estimation Schemes in Lake Shihwa and Incheon Coastal Zone (시화호 및 인천연안의 COD 오염부하량 추정기법)

  • Cho Hong-Yeon;Cho Bum-Jun
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.18 no.3
    • /
    • pp.262-267
    • /
    • 2006
  • For the concentration management in COD parameters, it requires the measurement and estimation of the COD pollutants load (hereinafter PL) in the watershed. The estimation method of the PL, however, is provided only based on the BOD parameters. The development of COD PL estimation schemes is expected to execute total PL management in coastal zone and needs to more observation and much time. This study provides COD PL estimation schemes using statistical information about ratio analysis with COD & BOD concentration of rivers and drainages of an industrial complex in Lake Shiwha and Incheon Coastal Zone watershed. The COD PL is computed with ease by multiplying the conversion factor, which is calculated as the sum of the average and 1 to 3 (safety factors) times standard deviation. The conversion factor of Lake Shihwa and Incheon Coastal Zone is estimated as 1.7, 2.3 and 2.9 with respect to the safety factor 1, 2, and 3, respectively.

Characteristics of Internal and External Exposure of Radon and Thoron in Process Handling Monazite (모나자이트 취급공정에서의 라돈 및 토론 노출 특성)

  • Chung, Eun Kyo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.2
    • /
    • pp.167-175
    • /
    • 2019
  • Objectives: The purpose of this study was to evaluate airborne radon and thoron levels and estimate the effective doses of workers who made household goods and mattresses using monazite. Methods: Airborne radon and thoron concentrations were measured using continuous monitors (Rad7, Durridge Company Inc., USA). Radon and thoron concentrations in the air were converted to radon doses using the dose conversion factor recommended by the Nuclear Safety and Security Commission in Korea. External exposure to gamma rays was measured at the chest height of a worker from the source using real-time radiation instruments, a survey meter (RadiagemTM 2000, Canberra Industries, Inc., USA), and an ion chamber (OD-01 Hx, STEP Co., Germany). Results: When using monazite, the average concentration range of radon was $13.1-97.8Bq/m^3$ and thoron was $210.1-841.4Bq/m^3$. When monazite was not used, the average concentration range of radon was $2.6-10.8Bq/m^3$ and the maximum was $1.7-66.2Bq/m^3$. Since monazite has a higher content of thorium than uranium, the effects of thoron should be considered. The effective doses of radon and thoron as calculated by the dose conversion factor based on ICRP 115 were 0.26 mSv/yr and 0.76 mSv/yr, respectively, at their maximum values. The external radiation dose rate was $6.7{\mu}Sv/hr$ at chest height and the effective dose was 4.3 mSv/yr at the maximum. Conclusions: Regardless of the use of monazite, the total annual effective doses due to internal and external exposure were 0.03-4.42 mSv/yr. Exposures to levels higher than this value are indicated if dose conversion factors based on the recently published ICRP 137 are applied.