• 제목/요약/키워드: Conversion Factor

검색결과 976건 처리시간 0.036초

Correlation Between the Optical Performance of the Reflective Polarizer and the Structure of LCD Backlight

  • Yu, Mi-Yeon;Lee, Byung-Woo;Lee, Jeong-Ho;Ko, Jae-Hyeon
    • Journal of the Optical Society of Korea
    • /
    • 제13권2호
    • /
    • pp.256-260
    • /
    • 2009
  • The optical performance of the reflective polarizer was investigated over three kinds of direct-lit backlights and/or different configurations of the optical sheets. The optical gain factor achieved by using the reflective polarizer increased as the diffuse nature of the optical sheet was enhanced, because of the more efficient polarization conversion. In addition, the gain factor decreased substantially in flat-lamp backlights compared to tubular-lamp backlights, which was ascribed to the high loss factor during the polarization recycling process due to the complex structure and large area of flat lamps. All these results suggested that reducing the loss factor of the backlight is very important for efficient polarization conversion and thus high optical gain of the reflective polarizer.

고압 나트륨 램프 구동용 전력변환장치의 역률 개선 (Power Factor improvement of Power Conversion Equipment for High Pressure Sodium Lamps)

  • 이상현;서기영;이현우;이수흠;문상필
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.147-150
    • /
    • 2002
  • HPSL(High Pressure Sodium lamp)have attracted much attention in recent years, because they offer high luminous efficiency and very long life. Recently, AC-DC converters have been widely as power factor improvement circuits in the power conversion equipment An application of the ZVT-PWM(Zero Voltage Transition Pulse Width Modulation) boost converter, which has great advantage on miniaturization and high power density, to the power factor improvement circuit of the HPSL inverter are described to identify the power factor correction characteristics of the inverter. In this paper the series-parallel resonant inverter(electronic ballast) for driving a HPS lamp is discussed. Finally, a power factor corrector is cascaded in front of the electronic ballast. Consequently, a high power factor above 0.99 and low THD on the line current can be achieved.

  • PDF

고정시간과 임의시간에 따른 우리나라 연최대강우량의 환산계수 산정 (Conversion Factor Calculation of Annual Maximum Precipitation in Korea Between Fixed and Sliding Durations)

  • 오태석;문영일
    • 대한토목학회논문집
    • /
    • 제28권5B호
    • /
    • pp.515-524
    • /
    • 2008
  • 합리적인 수공구조물의 설계를 위해서는 안정적인 확률강우량을 산정하는 것은 가장 중요한 과정 중의 하나이다. 확률강우량은 강우관측소에서 관측된 강우자료로부터 각 지속기간에 해당하는 연최대치 강우계열을 구성한 자료의 빈도해석을 통해 산정하게 된다. 연최대치 강우 계열은 대부분 시간강우량 또는 일강우량 자료를 통해 추출하므로, 적절한 고정시간-임의시간 환산계수를 연최대치 강우 계열에 반영할 필요성이 있다. 따라서 본 연구에서는 기상청에서 관측한 37개 지점의 분단위 강우자료와 시간 및 일 단위 강우자료를 활용하여 지속기간별로 고정시간-임의시간 환산계수를 추정하였다. 또한, 추정된 환산계수를 회귀분석하여 지속기간에 따른 고정시간-임의시간 환산계수의 회귀식을 유도하였다. 추정된 환산계수를 연최대치 강우 자료에 반영함으로써 보다 안정적인 확률강우량을 산정하는 기초자료로 활용할 수 있다.

기준연도 조정에 따른 환산지수 민감도 분석 연구 (A Study on the Sensitivity of Conversion Factor According to Change of Base Year)

  • 오동일
    • 한국산학기술학회논문지
    • /
    • 제21권4호
    • /
    • pp.201-209
    • /
    • 2020
  • 본 연구에서는 최근 수가계약 과정에서 논란이 되고 있는 기준연도 변경과 관련된 이슈를 살펴보았다. 이와 관련하여 기준연도 변경이 유형별 환산지수에 미치는 영향과 관련해 민감도분석을 실시하였다. 그리고 기준연도변경이 특정유형에 미치는 유리하거나 불리한 상황을 분석하였다. 또한 단일 환산지수 체계라고 가정하는 경우 기준연도 변경에 따른 환산지수 변동도 고찰하였다. 본 연구의 주요한 결론은 다음과 같다. 첫째, 기준연도를 현재시점에 가깝게 변경하는 경우 병원의 환산지수에는 유리한 효과가 발생한다. 둘째, 기준연도를 현재 시점에 가깝게 변경하는 경우 약국과 의원의 환산지수에는 불리한 효과가 발생하며 의원의 경우 불리한 효과가 크다. 셋째, 유형 전체에 단일 환산지수를 일괄적으로 적용한다고 가정하면 기준연도를 현재 시점에 가깝게 변경하는 경우 모든 유형에 유리한 효과가 발생한다. 기준연도 변동은 보험자와 의료공급자, 의료공급자 사이에 이해충돌을 가지고 올 수 있다. 따라서 자원 배분의 합리적인 근거를 바탕으로 상호 합의에 추진되어야 하며 손실이 초래되는 유형에 대해서는 한시적 보상을 위한 인센티브를 제시할 필요가 있다.

비다짐 성토지반의 합리적 토량평가를 위한 토량환산계수 추정 (Estimation of Soil Conversion Factor for the Non-compacted Soil in Embankment)

  • 오세욱;이봉직;김홍석
    • 한국지반환경공학회 논문집
    • /
    • 제18권11호
    • /
    • pp.13-18
    • /
    • 2017
  • 단지조성을 위한 성토과정에서 비다짐 시공은 별도의 다짐을 수행하지 않고 장비하중에 의해 다져지게 하는 공법으로 대부분의 현장에서 적용하고 있으나 구체적인 시공지침이나 시방에 명시되지 않아 토공량 평가에 불명확한 점이 있다. 본 연구에서는 단지조성을 위한 지반조성을 수행함에 있어 비다짐 성토지반에 대한 설계 토량환산계수와 실제 토량환산계수 값을 비교하여 타당성 여부를 검토하고 실내시험 및 현장시험, 하중-침하시험 등을 수행하여 합리적인 토량환산계수를 제안함으로써 현장에서의 토공 적정성을 검토하기 위한 기초연구이다. 비다짐 시 토량환산계수 C값은 1.0으로 설계하고 있으나, 현장실험결과 0.86으로 설계보다 작은 것으로 나타나 성토량이 증가될 것으로 예측되었으며, 시공결과 실제로 성토량에 차이가 발생하였다. 따라서 비다짐 성토의 경우 현장여건 및 성토고의 자중을 고려하여 현장조건에 적합한 C값을 실험을 통하여 적용하는 것이 타당할 것으로 판단된다.

Validation of a Model for Estimating Individual External Dose Based on Ambient Dose Equivalent and Life Patterns

  • Sato, Rina;Yoshimura, Kazuya;Sanada, Yukihisa;Sato, Tetsuro
    • Journal of Radiation Protection and Research
    • /
    • 제47권2호
    • /
    • pp.77-85
    • /
    • 2022
  • Background: After the Fukushima Daiichi Nuclear Power Station (FDNPS) accident, a model was developed to estimate the external exposure doses for residents who were expected to return to their homes after evacuation orders were lifted. However, the model's accuracy and uncertainties in parameters used to estimate external doses have not been evaluated. Materials and Methods: The model estimates effective doses based on the integrated ambient dose equivalent (H*(10)) and life patterns, considering a dose reduction factor to estimate the indoor H*(10) and a conversion factor from H*(10) to the effective dose. Because personal dose equivalent (Hp(10)) has been reported to agree well with the effective dose after the FDNPS accident, this study validates the model's accuracy by comparing the estimated effective doses with Hp(10). The Hp(10) and life pattern data were collected for 36 adult participants who lived or worked near the FDNPS in 2019. Results and Discussion: The estimated effective doses correlated significantly with Hp(10); however, the estimated effective doses were lower than Hp(10) for indoor sites. A comparison with the measured indoor H*(10) showed that the estimated indoor H*(10) was not underestimated. However, the Hp(10) to H*(10) ratio indoors, which corresponds to the practical conversion factor from H*(10) to the effective dose, was significantly larger than the same ratio outdoors, meaning that the conversion factor of 0.6 is not appropriate for indoors due to the changes in irradiation geometry and gamma spectra. This could have led to a lower effective dose than Hp(10). Conclusion: The estimated effective doses correlated significantly with Hp(10), demonstrating the model's applicability for effective dose estimation. However, the lower value of the effective dose indoors could be because the conversion factor did not reflect the actual environment.

AC-DC 전력변환기의 역률개선 제어기법에 관한 연구 (A study on control strategy of power factor correction for AC-DC power conversion system)

  • 곽동걸;이현우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 추계학술대회 논문집
    • /
    • pp.263-266
    • /
    • 2003
  • The high power factor converters are classified step-up, step-up-down and step-down converter, The power conversion system must be increased switching frequency in order to achieve a small size, a light weight and a low noise. And the power system brings on a high efficiency and high power factor. When a switch of the step down converter is operated with a commercial frequency(60Hz), a reactor using the converter is gone with a great number of harmonics waveforms of low grade. As results of this, the converter is decreased input power factor and is increased system size. To improved these, this paper proposes a PSM(Pulse Size Modulation) control strategy operated with high power factor.

  • PDF

매립폐기물의 겉보기밀도와 체적환산계수의 상관관계 연구 (A Study on Correlation between Volume Conversion Factor and Apparent Density of Wastes Buried in Landfill)

  • 조진우
    • 한국지반신소재학회논문집
    • /
    • 제19권4호
    • /
    • pp.33-40
    • /
    • 2020
  • 최근 대규모 택지개발 현장에서 굴착공정 중 매립폐기물이 발견되는 사례가 빈번히 발생되고 있다. 발생된 매립폐기물을 환경적으로 처리하기 전에는 대상지역의 개발사업을 진행할 수 없으며, 매립폐기물에 대한 처리대책을 수립하여 환경적이고 경제적으로 처리하여야 한다. 본 연구에서는 매립폐기물의 처리에 있어 단가 산정의 기본적인 계수가 되는 매립폐기물의 겉보기밀도와 체적환산계수의 상관관계를 분석하고자 하였다. 이를 위하여 ◯◯지역의 사용종료 매립지 10지점에서 매립폐기물을 채취하여 물리적성상을 분석한 후, 성상별 및 혼합폐기물의 겉보기밀도를 측정하였다. 매립폐기물의 겉보기밀도와 체적 환산계수의 상관관계를 분석하기 위하여, 매립폐기물의 겉보기밀도로부터 유추한 체적환산계수와 실측한 체적환산계수, 경험식에 의한 체적환산계수를 비교하였다. 분석결과, 겉보기밀도로부터 유추한 체적환산계수, 경험식에 의한 체적환산계수, 그리고 실측한 체적환산계수는 일정한 상관관계를 나타내고 있어, 겉보기밀도와 체적환산계수에 관한 기초자료로서 활용할 수 있을 것으로 판단된다.

A New Single-Stage PFC AC/DC Converter with Low Link-Capacitor Voltage

  • Lee, Byoung-Hee;Kim, Chong-Eun;Park, Ki-Bum;Moon, Gun-Woo
    • Journal of Power Electronics
    • /
    • 제7권4호
    • /
    • pp.328-335
    • /
    • 2007
  • A conventional Single-Stage Power-Factor-Correction (PFC) AC/DC converter has a link capacitor voltage problem under high line input and low load conditions. In this paper, this problem is analyzed by using the voltage conversion ratio of the DC/DC conversion cell. By applying this analysis, a new Single-Stage PFC AC/DC converter with a boost PFC cell integrated with a Voltage-Doubler Rectified Asymmetrical Half-Bridge (VDRAHB) is proposed. The proposed converter features good power factor correction, low current harmonic distortions, tight output regulations and low voltage of the link capacitor. An 85W prototype was implemented to show that it meets harmonic requirements and standards satisfactorily with near unity power factor and high efficiency over universal input.

PWM-based Integral Sliding-mode Controller for Unity Input Power Factor Operation of Indirect Matrix Converter

  • Rmili, Lazhar;Hamouda, Mahmoud;Rahmani, Salem;Blanchette, Handy Fortin;Al-Haddad, Kamal
    • Journal of Power Electronics
    • /
    • 제17권4호
    • /
    • pp.1048-1057
    • /
    • 2017
  • An indirect matrix converter (IMC) is a modern power generation system that enables a direct ac/ac conversion without the need for any bulky and limited lifetime electrolytic capacitor. This system also allows four-quadrant operation, generation of sinusoidal output voltage waveforms with variable frequency and amplitude, and control of input power factor. This study proposes a pulse-width modulation-based sliding-mode controller to achieve unity input-power factor operation of the IMC independently of the active power exchanged with the grid, as well as a fast dynamic response. The designed equivalent control law determines, at each sampling period, the appropriate q-axis component of the modulated input current to be injected into the grid through the LC input filter. An integral term of the error is included in the expression of the sliding surface to increase the accuracy of the control method. A double space vector modulation method is used to synthesize the direction of the space vector of the input currents as required by the sliding-mode controller and the space vectors of the target output voltages. Simulation and experimental results are provided to show the effectiveness and evaluate the performance of the proposed control method.