• Title/Summary/Keyword: Conventional water supply

Search Result 137, Processing Time 0.029 seconds

Epidemiologic Investigation to Identify the Cause of an Infant Methemoglobinemia (서울 S지역에서 발생한 영아 메트헤모글로빈혈증 1례의 원인구명을 위한 역학조사)

  • Kim, Young-Yeul;Choi, Bo-Youl;Park, Hang-Bae;Kim, Min-Young;Yeo, In-Hak
    • Journal of Preventive Medicine and Public Health
    • /
    • v.26 no.2 s.42
    • /
    • pp.192-201
    • /
    • 1993
  • Epidemiologic investigation was conducted on January, 1993 in Seoul to identify the cause of an infant methemoglobinemia. Field investigation of the area of outbreak, survey of household and family members, analysis of ground water, and blood tests of involved family members were performed. Following results were obtained On analyzing the quality of the ground water on patient's household high levels of nitrate was found indicating contamination of water as the cause of a methemoglobinemia outbreak. On analysing the quality of the ground waters on seven other places within the neighborhood five were contaminated by nitrate in concentration that exceeded the permissible limit implying presence nearby source of contamination. Sources of contamination were thought to be originating from human waste in conventional bathroom facilities, chicken manure used in nearby orchards and plant fields or fertilizers. But the results of water analysis with presence of bacteria or E.coli, concentration of potassium, phosphate and the past history of diarrhea among family members, chicken manure suggested the most possible source of contamination. To evaluate the health status of members in the neighborhood past history was reviewed revealing no prior existence of patient with cyanosis and 65 people in the neighborhood had normal levels of methemoglobin concentration in their blood. Conclusively, the ground water on patient's household was contaminated with nitrate and despite provision of adequate water supply, family members of the patient along with their distrust in the water supply system had used ground water as their source of drinking water resulting of methemoglobinemia. Many suburban area of Seoul and country side thought to be having similar problems concerning contaminated ground water supply and dormant outbreak of patients as a result of the drinking of the contaminated water. Epidemiologic investigation and water analysis of ground waters are advised.

  • PDF

Application of a Watershed-Based Land Prioritization Model for the Protection of Drinking Water Reservoir (상수원 보호를 위한 유역기반 토지관리 우선순위 모델 적용)

  • Lee, Jee Hyun;Choi, Ji Yang;Park, Seok Soon
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.5
    • /
    • pp.397-408
    • /
    • 2004
  • Due to the growing impact of non-point source pollution and limitation of water treatment technology, a new policy of water quality management, called a source protection, is now becoming more important in drinking water supply. The source protection means that the public agency purchases the pollution sensitive area, such as riparian zone, and prohibit locations of point and non-point sources. Many studies have reported that this new policy is more economical in drinking water supply than the conventional one. However, it is very difficult to determine location and size of the pollution sensitive zone in the watershed. In this paper, we presented the scientific criteria for the priority of the pollution sensitive zone, along with a case study of the upstream watershed of the Paldang Reservoir, Han River. This study includes applications of the analytical hierarchy process(AHP) and a watershed-based land prioritization(WLP) model. After major criteria affecting water quality were selected, the AHP and geographic analysis were performed. The WLP model allowed us to include both quantity and quality criteria, using AHP as the multi-criteria method in making decision and reflecting local characteristics and various needs. By adding a travel-time function, which represents the prototype effectively, the results secured adaptability and scientific objectivity as well. As such, the WLP model appeared to provide reasonable criteria in determining the prioritization of land acquisition. If the tested data are used with a validated travel-time and AHP method is applied after further discussion among experts in such field, highly reliable results can be obtained.

An experimental study on decision making for multi-source water (다중수원 수처리 의사결정에 관한 실험적 연구)

  • Jung, Jungwoo;Cho, Hyeong-Rak;Lee, Sangho;Chae, Soo-Kwon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.1
    • /
    • pp.1-9
    • /
    • 2015
  • A combined treatment system using multiple source water is becoming important as an alternative to conventional water supply for small-scale water systems. In this research, combined water treatment systems were investigated for simultaneous use of multi-source water including rainwater, ground water, river water, and reclaimed wastewater. A laboratory-scale system was developed to systematically compare various combinations of water treatment processes, including sand filtration, microfiltration (MF), granular activated carbon (GAC), and nanofiltration (NF). Results showed that the efficiency of combined water treatment systems was affected by the quality of feed waters. In addition, a simply approach based on the concept of linear combination was suggested to support a decision-making for the optimum water treatment systems with the consideration of final water quality.

Site Suitability Analysis for Bank Filtration Using AHP (AHP를 이용한 강변여과 적지 분석)

  • Kim, Byeong-Chan;Lee, Seung-Chui;Ryu, Ji-Hyeob
    • Journal of Korean Society of societal Security
    • /
    • v.1 no.2
    • /
    • pp.53-59
    • /
    • 2008
  • The lack of water resources is becoming a serious issue throughout the world. The water shortage in Korea is expected to increase. Groundwater can be a solution to this matter in some places. Especially, bank filtrations are known to be advantageous over conventional reserviors, even if they have some drawbacks such as their limited location for development and small sizes. The AHP(Analytic Hierarchy Process) is an analytical tool, supported by simple mathematics, which enables one to explicitly rank tangible and intangible factors against each other for the purpose of resolving conflicts or setting priorities. In order to check the applicability of AHP to the evaluation of bank filtration sites, four candidate locations were chosen. They have suffered from problems like water-supply shortage and delayed dam construction. The analysis results are compared with those of the previous study using a conventional method. It is believed that the developed method can a basis for reasonable decision-making regarding bank filtration development.

  • PDF

Site Suitability Analysis for Underground Dam Using Analytic Hierarchy Process (계층분석과정을 이용한 지하댐 적지분석)

  • 이상일;김병찬
    • Journal of Soil and Groundwater Environment
    • /
    • v.8 no.4
    • /
    • pp.36-44
    • /
    • 2003
  • The lack of water resources is becoming a serious issue throughout the world. The water shortage in Korea is expected to increase dramatically through 2020. The amount of water shortage could amount to 1.8 and 2.6 billion cubic meters in 2011 and 2020, respectively. Groundwater can be a solution to this matter in some places. Especially, underground dams are known to be advantageous over conventional dams, evert if they have some drawbacks such as their limited location for development and small sizes. The analytic hierarchy process(AHP) is an analytical tool, supported by simple mathematics, which enables one to explicitly rank tangible and intangible factors against each other for the purpose of resolving conflicts or setting priorities. In order to check the applicability of AHP to the evaluation of underground dam sites, lour candidate locations were chosen. They have suffered from problems like water-supply shortage and delayed dam construction. The analysis results are compared with those of the previous study using a conventional method. It is believed that the developed method can provide central or local government with a basis for reasonable decision-making regarding underground dam development.

A Ten-year Survey of Giardia Cysts in Drinking Water Supplies of Seoul, the Republic of Korea

  • Lee, Mok-Young;Cho, Eun-Joo;Lee, Jin-Hyo;Han, Sun-Hee;Park, Yong-Sang
    • Parasites, Hosts and Diseases
    • /
    • v.49 no.1
    • /
    • pp.9-15
    • /
    • 2011
  • To understand the distribution of Giardia cysts in drinking water supplies in Seoul, Korea, we collected water samples quarterly at 6 intakes in the Han River, its largest stream and 6 conventional water treatment plants (WTPs) serving drinking water, from 2000 to 2009. Giardia cysts in each of 10 L water were confirmed in 35.0% of intake water samples and the arithmetic mean was 1.65 cysts/10 L (range 0-35 cysts/10 L). The lowest cyst density was observed at Paldang and Kangbuk intakes, and the pollution level was higher at 4 intakes downstream. It seemed that these 4 intakes were under influence of Wangsuk stream at the end of which cysts were found in all samples with the mean of 140 cysts/10 L. The annual mean number of cysts was 0.21-4.21 cysts/10 L, and the cyst level at the second half of the 10 years was about 1/5 of that at first half on average. The cysts were more frequently found in winter, and their mean density was 3.74 cysts/10 L in winter and 0.80-1.08 cysts/10 L in other seasons. All finished water samples collected at 6 WTPs were negative for Giardia in each of 100 L sample for 10 years and cyst removal by physical process was average 2.9-log. It was concluded that conventional water treatment at 6 WTPs of Seoul appears to remove the cysts effectively under the present level of their source water. Domestic wastewater from the urban region could be an important source of Giardia pollution in the river.

The Development and Performance Analysis of Compact Type Solar Thermal/Ground Coupled Heat Pump Hybrid System for Heating, Cooling and Hot water (콤팩트형 태양열/지열히트펌프 하이브리드 냉난방 및 급탕 시스템 개발 및 성능분석)

  • Baek, Nam-Choon;Jeong, Seon-Yeong;Yoon, Eung-Sang;Lee, Kyoung-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.5
    • /
    • pp.59-67
    • /
    • 2012
  • In this study,the compact type solar thermal and ground coupled heat pump hybrid system for space heating/cooling and hot water supply has been developed. This hybrid system was installed in Zero Energy Solar House(ZeSH) in KIER for the demonstration. The thermal performance and operational characteristics of this hybrid system were analysed especially. The results are as follows. (1) This hybrid system was designed in order to address the existing disadvantages of solar thermal/ground coupled heat pump system. For this design, all parts except solar collector and ground coupled heat pump were integrated into a single product in a factory. The compact type unit includes two buffer tanks, an expansion tank, pumps, valves, a controller, etc. This system has an advantage of easy installation with simple plumbing work even in narrow space. (2) The thermal charging and discharging time of the buffer tanks and its characteristics by ground coupled heat pump, and heat pump COP according to geo-source temperature and buffer storage temperature have been studied. This system was found to meet well to the heat load without any other auxiliary heating equipment. (3) The operating hours of the ground coupled heat pump as a backup device of solar thermal can be reduced significantly by using solar heat. It was also found that the minimum heating water supply setting temperature and maximum cooling water supply setting temperature make an influence on the heat pump COP. The lower heating water and the higher cooling water temperature, the higher COP. In this respect, the hybrid system's performance can be improved in ZeSH than conventional house.

A Water Budget Analysis with Inter-basin Water Transfer Taken Spatially into Considerations (외부공급을 공간적으로 고려한 물수지 분석)

  • Yoon, Yong Nam;Kim, Tae Guen
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.1
    • /
    • pp.89-96
    • /
    • 1993
  • The conventional water budget analysis methods for major water works do not take the spatial variation of available water resources into account. There has also been a tendency of over-estimation of water supply capacity when a significant inter-basin water transfer is involved. Therefore, a revised water budget analysis methodology is proposed which can take care of the spatial variation of the water resources available within the basin and with the inter-basin transferable water. For the purpose of present study, the Saemangeum project area is taken for the analysis, which includes both the Dongjin and the Mangyungs River basin, one of the regions with the most complex water utilization.

  • PDF

Development of IoT-Based Automatic Paddy Inlet for Efficient Water Management (효율적 물관리를 위한 IoT 기반 논 관개수로 자동 물꼬 개발)

  • Song, Soekho;Ahn, Chiyong;Song, Chulmin
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.66 no.2
    • /
    • pp.13-24
    • /
    • 2024
  • This study aims to contribute to efficient paddy field water management by developing an IoT-based automatic paddy inlet that can consider water level changes according to variations in the supplied water quantity through irrigation channels. This IoT-based automatic paddy inlet not only ensures water level changes based on the supply of irrigation water but also secures irrigation efficiency. The effectiveness and efficiency of the developed IoT-based automatic paddy inlet were presented to contribute to efficient paddy field water management. As a result, the IoT-based automatic paddy inlet demonstrated the capability to maintain the optimal water level in the paddy field. Particularly, it exhibited up to 18.4% higher water resource usage efficiency compared to conventional paddy inlet, emphasizing the IoT-based automatic paddy inlet's advantage in terms of water resource usage.

Membrane Technology for Waste Water Recovery

  • Okazaki, Minoru
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1996.10a
    • /
    • pp.22-33
    • /
    • 1996
  • With the experience of the 1994 drought, and the shortage of water resources in Japan, it has been re-informed upon us ensure and maintain the stability of water resources. Accordingly, with each plant, a serious appraisal has begun looking at the re-use of waste water. Membrane technology is an important process for waste water recovery. Effluent kom waste water facilities changes the quality of water significantly. The conventional pre-treatment of RO is hard to supply good quality feed water to RO in the waste water recovery system. The microfiltration system as a pre-treatment of RO in the paper overcomes the fouling with the air backwash and is operated in direct flow mode at a low pressure producing a high flux. The paper will focus the waste water recovery using membrane technology and many examples will be given.

  • PDF