• Title/Summary/Keyword: Conventional water supply

Search Result 137, Processing Time 0.027 seconds

A Study on the Performance Characteristics of a Heat Pump System using Stack Wast Heat in Fuel Cell Vehicles (스택 폐열을 이용한 연료전지 자동차용 열펌프 시스템의 성능 특성에 관한 연구)

  • Jeon, Byungyong;Ko, Wonbin;Park, Youn Cheol
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.8
    • /
    • pp.325-330
    • /
    • 2016
  • This study was conducted to develop a heating system for a fuel cell-driven electric vehicle. The system consists of a compressor, an expansion device and three heat exchangers. A conventional air source heat exchanger is used as primary heat exchanger of the system, and an additional water source heat exchanger is used as a pre-heater to supply heat to the upstream air of the primary heat exchanger. On the other hand, the third heat exchanger consists of a water-to-refrigerant heat exchanger. The heat source of the pre-heater and the water-refrigerant heat exchanger is the waste heat from the fuel cell's stack. In the experiment, the indoor and the outdoor air temperature were fixed, and the compressor speed, EEV opening and waste heat temperature were varied. The results indicate that the $COP_h$ of the proposed system is 3.01 when the system is operating at a 1,200 rpm compressor speed, 50% EEV opening, and $50^{\circ}C$ waste heat source temperature in air pre-heater operation. However, when the system uses a water-refrigerant heat exchanger, the $COP_h$ increases to up to 9.42 at the same compressor speed and waste heat source temperature with 75% EEV openings.

Effect of Water Stress at Different Growth Stages on the Growth and Yield of the Transplanted Rice Plants (벼의 생육기별 수분결핍장애가 생육 및 수량에 미치는 영향)

  • 남상용;권용웅;권순국
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.28 no.2
    • /
    • pp.31-41
    • /
    • 1986
  • Knowledge of the degree of yield reduction due to water stress at different crop growth stages in rice production is important for rational scheduling of irrigation during periods of insufficient water supply. Previous studies to determine the degree of yield reduction duo to water stress suffered from interruptions by rain during experiment. Also the findings did rot relate the degree of water stress to the soil water potential and water deficit status of rice plants. In this study, two years experiments were conducted using the high yielding rice varieties, an Indica x Japonica (Nampoong) and a Japonica variety(Choochung). These were grown in 1/200$^{\circ}$ plastic pots placed under a rainfall autosensing, sliding clear plastic roof facility to control rainfall interruptions. The results obtained were as follows. 1.The two varieties differed in the growth stage most sensitive to water stress as well as the degree of yield reductions. When rice plants were stressed to the leaf rolling score 4 and soil water potential of about - 20 bar at major crop growth stages which included heading, booting, non-effective tillering, panicle initiation and early tillering stages, the yield reductions in the Indica x Japonica variety were 58%, 34%, 27%, 22%, and 21%, respectively, whereas in the Japonica vairety they were 23%, 36%, 1%, 13% and 22%, respectively. This result show that the recommended drainage during non-effective tillering is valid only for the Japonica variety. Sufficient irrigation at booting, heading and early tillering stages are necessary for both varieties. 2.The two varieties showed visible wilting symptoms when the soil water potential dropped to about - 3.0 bar. The Japonica variety showed more leaf rolling than the Indica X Japonica. However, it had a higher retention of leaf water content and greater stomatal diffusive resistance. When the soil water potential dropped, the Japonica variety showed leaf rolling score (LRS) 1 at 0 soil-5. 0 bar and LRS 2 at 0 soil -6.0 bar while the Indica X Japonica showed LRS 1 at 0 soil - 5.5 bar and LRS 2at 0 Soil - 9.0 bar. The stomatal diffusive resistance was maximum at the second top leaf blade in both varieties at intermediate water stress of 0 soil - 4.5 bar. 3.The number of days that was required for the soil water potential to drop to-3. 0 bar and to - 20.0 bar after drainage of irrigation water from the 20cm deep silty clay loam soil in the pots were 6 and 13 days, respectively for booting stage, and 7 and 11 days, respectively for heading stage, 9 and 12 days, respectively for panicle initiation stage, and 12 and 19 days, respectively for early tillering stage. 4.Water stress during the early tillering stage recorded the longest delay in beading time, the largest reduction in panicle numbers and a substantial yield decrease of 20%. This calls for better water management to ensure the availability of water at this stage, particularly during drought periods. In addition, a reexamination of the conventional inter-drainage practice during the non-effective tillering stage is necessary for the high yielding Indica X Japonica varieties.

  • PDF

Water Quality Analysis and Evaluation of Management Strategies and Policies in Laguna Lake, Philippines (필리핀 라구나호수의 수질분석 및 관리 정책 평가)

  • Reyes, Nash Jett D.G.;Geronimo, Franz Kevin F.;Redillas, Marla M.;Hong, Jungsun;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.20 no.1
    • /
    • pp.43-53
    • /
    • 2018
  • Laguna Lake is the largest inland fresh water body in the Philippines. It primarily serves as a site for aquaculture, hydropower, transportation, and water supply industries. Due to Laguna Lake's diverse functionalities, competition among water users became prominent. Water quality began to deteriorate due to various pollutant contributions in this process, thereby affecting the soundness of the aquatic ecosystem. This study was conducted to evaluate the current water quality management policy from the viewpoint of ecological environment through the evaluation of the water quality of Laguna Lake. Concentrations of water pollutants such as ammonia ($NH_3$), biochemical oxygen demand (BOD), chloride ($Cl^-$), pH, and total suspended solids (TSS) exceeded the water quality standards of the Philippines' Department of Environment and Natural Resources (DENR). The water quality of the lake was also affected by the pollutant load due to agriculture and urban stormwater runoff in the watershed. The salinity and contaminated water from Pasig River also affected the water quality of Laguna Lake. Long-term water quality analysis showed that the water quality of Laguna Lake is also influenced by rainfall-related seasonal variations. The results of the water quality analysis of Laguna Lake indicated that the environmental management techniques of the Philippines should be changed from the conventional water management into an integrated watershed management scheme in the future. It is therefore necessary to study and introduce advanced watershed management measures in the Philippines based from the policies of other developed countries.

Development of prediction models of chlorine bulk decay coefficient by rechlorination in water distribution network (상수도 공급과정 중 재염소 투입에 따른 잔류염소농도 수체감소계수 예측모델 개발)

  • Jeong, Bobae;Kim, Kibum;Seo, Jeewon;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.1
    • /
    • pp.17-29
    • /
    • 2019
  • This study developed prediction models of chlorine bulk decay coefficient by each condition of water quality, measuring chlorine bulk decay coefficients of the water and water quality by water purification processes. The second-reaction order of chlorine were selected as the optimal reaction order of research area because the decay of chlorine was best represented. Chlorine bulk decay coefficients of the water in conventional processes, advanced processes before rechlorination was respectively $5.9072(mg/L)^{-1}d^{-1}$ and $3.3974(mg/L)^{-1}d^{-1}$, and $1.2522(mg/L)^{-1}d^{-1}$ and $1.1998(mg/L)^{-1}d^{-1}$ after rechlorination. As a result, the reduction of organic material concentration during the retention time has greatly changed the chlorine bulk decay coefficient. All the coefficients of determination were higher than 0.8 in the developed models of the chlorine bulk decay coefficient, considering the drawn chlorine bulk decay coefficient and several parameters of water quality and statistically significant. Thus, it was judged that models that could express the actual values, properly were developed. In the meantime, the chlorine bulk decay coefficient was in proportion to the initial residual chlorine concentration and the concentration of rechlorination; however, it may greatly vary depending on rechlorination. Thus, it is judged that it is necessary to set a plan for the management of residual chlorine concentration after experimentally assessing this change, utilizing the methodology proposed in this study in the actual fields. The prediction models in this study would simulate the reduction of residual chlorine concentration according to the conditions of the operation of water purification plants and the introduction of rechlorination facilities, more reasonably considering water purification process and the time of chlorination. In addition, utilizing the prediction models, the reduction of residual chlorine concentration in the supply areas can be predicted, and it is judged that this can be utilized in setting plans for the management of residual chlorine concentration.

Treatment Technologies for Removal of Polybrominated Diphenyl Ethers (PBDEs) from Wastewater (하·폐수내 브롬화 디페닐 에테르(Polybrominated Diphenyl Ether, PBDEs)의 분포 및 제거기술 동향)

  • Kim, Minhee;Hyun, Seunghun;Lee, Won-Seok
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.6
    • /
    • pp.754-768
    • /
    • 2017
  • Polybrominated diphenyl ethers (PBDEs) are a group of industrial aromatic organobromine chemicals that have been used since the 1970s as flame retardants in a wide range of consumer products and articles, including plastics, computers, textiles and upholstery. Commercial PBDEs were added to Annex A of the Stockholm Convention as persistent organic pollutants in May 2009. PBDEs are still frequently found in sludge and effluent from wastewater treatment plants, even though commercial PBDEs were prohibited or voluntarily phased out several years ago. Conventional wastewater treatment processes are not designed to effectively remove PBDEs. This indicates that there is an urgent need for new developments and improvements to enhance upon the treatment techniques which are currently available. Several studies have suggested the potential removal and degradation technologies for PBDEs in wastewater. In this study, the concentrations and compositional profiles of PBDE congeners in sludge and effluent are investigated by analyzing the relevant literature data in relation to their usage patterns in commercial products in North America and South Korea. The strengths and weaknesses of the current PBDEs removal techniques (i.e., biodegradation, zero-valent iron, photolysis, sorption, etc.) are discussed critically. In addition, future research direction regarding the treatment and removal of PBDEs from wastewater is also suggested, based on the literature review.

Performance Evaluation of Water Loss Management in Urban Areas Using Different Performance Indicators (여러 가지 지표를 이용한 전국도시의 물손실관리 수행능 비교평가)

  • Chung, Shin-Ho;Yu, Myong-Jin;Koo, Ja-Yong;Lee, Hwa-Kyoung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.2
    • /
    • pp.117-127
    • /
    • 2006
  • Recently International Water Association(IWA) has proposed new performance indicators for water supply services and their successful applications are being reported continually. According to the various reports, the percentage indicators were suggested not to be used for performance comparison, especially where the targeted areas have great difference in consumption per service connection. But unfortunately in Korea the revenue water ratio, one of the percentage indicators is still being used to set up the goal of water-related administration and to compare the performances between systems. Therefore this study aimed to prove the inapplicability of the percentage indicators with nation-wide data and to suggest better performance indicators for more efficient water loss management. According to the result of the comparison of various performance indicators with conventional one, it is roved that percentage indicators ca not evaluate the performance efficiently where the local situations are significantly different. It is suggested that the better performance indicators such as real losses per service connection or ILI should be used to benchmark the performances of water suppliers on water loss management so thai the problems of water losses could be identified easily and recovered effectively.

Prediction of Pull-Out Force of Steel Pegs Using the Relationship Between Degree of Compaction and Hardness of Soil Conditioned on Water Content (함수비에 따른 토양의 다짐도와 경도의 관계를 이용한 철항의 인발저항력 예측 연구)

  • Choi, In-Hyeok;Heo, Gi-Seok;Lee, Jin-Young;Kwak, Dong-Youp
    • Journal of the Korean Geotechnical Society
    • /
    • v.39 no.12
    • /
    • pp.23-35
    • /
    • 2023
  • The Ministry of Agriculture, Food and Rural Affairs has announced design standards for disaster-resilient greenhouses capable of resisting wind speeds with a 30-year frequency to respond to the destruction of greenhouses caused by strong winds. However, many greenhouses are still being maintained or newly installed as conventional standard facilities for the supply type. In these supply-type greenhouses, a small pile called a steel peg is used as reinforcement to resist wind-induced damage. The wind resistance of steel pegs varies depending on the soil environment and installation method. In this study, a correlation analysis was performed between the wind resistance of steel pegs installed in loam and sandy loam, using a soil hardness meter. To estimate the pull-out force of steel pegs based on soil water content and compaction, soil compaction tests and laboratory soil box and field tests were performed. The soil compaction degree was measured using a soil hardness meter that could easily confirm soil compaction. This was used to analyze the correlation between the soil compaction degree in the tests. In addition, a correlation analysis was performed between the pull-out force of steel pegs in the soil box and field. The findings of this study will be useful in predicting the pull-out force of steel pegs based on the method of steel peg installation and environmental changes.

Evaluation on the removal efficiency of pharmaceutical compounds in conventional drinking water treatment processes (정수처리 공정에서 잔류의약물질 제어 효율 평가)

  • Seo, Hee-Jeong;Park, Yong-Hoon;Kang, In-Sook;Myong, Hwa-Bong;Song, Yang-Suk;Kang, Yeong-Ju
    • Analytical Science and Technology
    • /
    • v.29 no.3
    • /
    • pp.126-135
    • /
    • 2016
  • In the present study, we evaluated the efficiency of the drinking water treatment unit processes controlled by targeting high pharmaceutical compounds that are likely to be released into the water supply. In the coagulation process, the removal rate of sulfonamide, an antibiotic, amounted to 22.6~42.1 %, that of naproxen to 28.2 %, and that of acetaminophen to 20 %. Trimethoprim has demonstrated a low removal rate (4.4 %), while the removal rate of erythromycin was 2.4 %; aspirin was not removed at all. When applying a mixture of chlorination and the coagulation process, the removal rate was increased with increasing the chlorine dosage. When the chlorine injection with the concentration of 3 mg/L was applied, sulfonamide antibiotics, acetaminophen and naproxen, were completely removed. Trimethoprim exhibited a high removal efficiency of ca. 98%, while the removal efficiency of erythromycin was about 55 %; at the same time, aspirin showed a lower removal ratio (ca. 10 %). When applying the powdered activated carbon adsorption process, the removal rate was increased with increase of the concentration of the powder activated carbon injection. Sulfonamide antibiotics showed about 18~50 % removal efficiency in the 1 mg/L, the removal rate was increased by at least 80 % in 25 mg/L. The evaluation results of the titration injection concentration of chlorine treatment and adsorption, coagulation process for the efficient processing of the remaining pharmaceutical compounds in the water treatment process, when applying the chlorine 3 mg/L, powdered activated carbon 10 mg/L and coagulant 15 mg/L were removed more than 90 %.

Frequency control method of ozonator power supply (오존발생기 구동장치의 주파수제어에 관한 연구)

  • 최규남
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.3 no.4
    • /
    • pp.887-893
    • /
    • 1999
  • The characteristics of ozone generator targeted for air or water sterilizing in the vessel utilizing the surface corona discharge between the electrodes on the ceramic substrate was investigated by using the frequency control method. The frequency control was achieved by controlling the degree of resonance between the secondary winding inductance of transformer and the electrode capacitance of ceramic discharge plate, and the range of control was found to be 5 times of discharge current. This frequency control method showed the efficiency of 28 mP ozone generation and the stability within 3.4 % when the input voltage was varied within 40% range. The frequency control method is regarded to be more efficient way of corona discharge control compared to the conventional on/off control or voltage control methods.

  • PDF

A Study on Interlayer Dielectric CMP Using Diamond Conditioner (다이아몬드 컨디셔너를 이용한 ILD CMP에 관한 연구)

  • 서헌덕;김형재;김호윤;정해도
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.86-89
    • /
    • 2003
  • Chemical Mechanical Planarization(CMP) has been accepted as the most effective processes for ultra large scale integrated (ULSI) chip manufacturing. However, as the polishing process continues, pad pores get to be glazed by polishing residues, which hinder the supply of new slurry. And pad surface is ununiformly deformed as real contact distance. These defects make material removal rate(MRR) decrease with a number of polishied wafer. Also the desired within-chip planarity, within wafer non-uniformity(WIWNU) and wafer to wafer non-uniformity(WTWNU) arc unable to be achieved. So, pad conditioning in CMP Process is essential to overcome these defects. The eletroplated or brazed diamond conditioner is used as the conventional conditioning. And. allumina long fiber, the jet power of high pressure deionized water, vacuum compression. ultrasonic conditioner aided by cavitation effect and ceramic plate conditioner are once used or under investigation. But. these methods arc not sufficient for ununiformly deformed pad surface and the limits of conditioning effect. So this paper focuses on the characteristics of diamond conditioner which reopens glazed pores and removes ununiformly deformed pad away.

  • PDF