• 제목/요약/키워드: Conventional water supply

검색결과 137건 처리시간 0.02초

분산형 용수공급시스템 구축을 위한 정수처리시설 최적 위치 결정 (Determination of the Optimal Location for Water Treatment Plants in the Decentralized Water Supply System)

  • 장동일;하금률;전환돈;김정현;강기훈
    • 상하수도학회지
    • /
    • 제27권1호
    • /
    • pp.1-10
    • /
    • 2013
  • Major issues in water supply service have changed from expansion of service area to improvement of service quality, i.e., water quality and safety, and early response to emergency situation. This change in the service concept triggers the perceptions of limitation with the current centralized water supply system and of necessities of decentralized (distributed) water supply system (DWSS), which can make up the limitations. DWSS can reduce the possibility of water supply outage by establishing multiple barriers such as emergency water supply system, and secure better water quality by locating treatment facilities neighboring consumers. On the other hand, fluctuation of water demand will be increased due to the reduced supply area, which makes difficult to promptly respond the fluctuating demand. In order to supplement this, hybrid water supply system was proposed, which combined DWSS with conventional water supply system using distributing reservoir to secure the stability of water supply. The Optimal connection point of DWSS to existing water supply network in urban area was determined by simulating a supply network using EPANET. Optimal location of decentralized water treatment plant (or connection point) is a nodal point where changes in pressure at other nodal points can be minimized. At the same time, the optimal point should be selected to minimize hydraulic retention time in supply network (water age) to secure proper water quality. In order to locate the point where these two criteria are satisfied optimally, Distance measure method, one of multi-criteria decision making was employed to integrate the two results having different dimensions. This methodology can be used as an efficient decision-support criterion for the location of treatment plant in decentralized water supply system.

공공하수처리시설 수질기준 선진화 방안 (Improvement on Sewerage Effluent Standard of Public Sewerage Treatment Plants)

  • 유순주;박상민;권오상;박수정;염익태
    • 한국물환경학회지
    • /
    • 제29권2호
    • /
    • pp.276-287
    • /
    • 2013
  • Domestic sewage contains increasingly more pharmaceuticals and personal care products (PPCPs), due to rising use of medicines, health supplement food and daily necessities. And various types of industrial wastewater from pollution sources in treatment areas could flow into the public sewerage treatment plants (PSTPs) in metropolitan areas. The conventional PSTPs are designed to treat suspended solids, biodegradable organics, nitrogen and phosphorous from residential and industrial areas and public facilities. However, toxic, conventional, and non-coventional pollutants from non-domestic sources that discharge into sewer system as well as domestic source with various chemicals could not be treated in the conventional PSTPs and discharged untreated to public basin. In this paper we aim to consider the establishment system of effluent standard of PSTPs in comparison with water quality standard of water environment and wastewater discharge regulation. And also we suggest the necessity of regulations on the pretreatment of industrial wastewater as part of efforts to improve water quality in sewerage systems and to protect public basin.

BYG형 급수기의 MINI PC 제어 시스템 (Mini PC control system for BYG type water supply units)

  • 박용규;강영모
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1993년도 한국자동제어학술회의논문집(국내학술편); Seoul National University, Seoul; 20-22 Oct. 1993
    • /
    • pp.1167-1171
    • /
    • 1993
  • A highly efficient hydropneumatic water supply system type BGY is designed and built in accordance with ISO standard. The technical features of BYG type pump unit can be summarized as follows: - reduce hydropneumatic tank capacity at the ratio of 1/10 - 1/30 compared with conventional method. - ISO standard pumps can be used. - the development of highly efficient water supply system type BYG is based on long-term experiences with the proven constant pressure water supply technique which minimize pressure fluctuation, rapid pilsation, etc. The text contains the operation principle of BYG type water supply system, introduction of closed cycle control process focused on Mini PC and experimental results of type BYG-IVS-90x45.

  • PDF

마이크로 용적형 수차의 개발에 관한 연구 (A Study on the Development of a New Micro Positive Displacement Hydraulic Turbine)

  • 이영호;최영도
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권2호
    • /
    • pp.284-290
    • /
    • 2006
  • For the case of high head and critical low flow rate range of micro hydropower resources, it requires very low specific speed turbines which are lower than conventional impulse turbine's specific speed. In order to satisfy the request for very low specific speed turbine with high efficiency, a new positive displacement turbine is developed. The performance characteristics of the new turbine is tested and compared with a conventional impulse turbine, which is used for automatic water faucet system. The purpose of present study is to develop an high performance turbine that can be used to extract micro hydropower potential of a water supply system. The test results show that the positive displacement turbine is much more efficient than the conventional turbine and it can sustain high efficiency under the wide range of operating conditions. The pressure pulsations at the inlet and outlet of the positive displacement turbine can be considerably minimized by using simple pressure damper.

최적화 기법을 이용한 광역상수도 관로시스템 설계 (Design of Multi-Regional Water Supply System Based on the Optimization Technique)

  • 김주환;김종우;박재홍
    • 상하수도학회지
    • /
    • 제13권1호
    • /
    • pp.95-112
    • /
    • 1999
  • In this research, it is proposed that optimization method is introduced and applied to the design of pipeline system in multi-regional water supply project, which has been constructed to settle the regional unbalance problems of available water resources. For the purpose, interface programs are developed to integrate linear programming model and KYPIPE model which is used for optimization and hydraulic analysis, respectively. The developed program is applied to the pipeline system design of multi-regional water supply project. The optimal diameters from the application of linear programming technique are compared with those from conventional method that is time-consuming and tedious trail and error process. Since the conventional design largely depends upon the experience of designers and the results of general hydraulic analysis, it can not be reasonable and consistent. The application of linear programming technique can make it possible to design pipeline system optimally by using same design factors of general hydraulic models. The model can select commercial discrete pipe diameter as optimal size by using pipe length as decision variables. The developed model is applied to Pohang multi-regional water supply system design with two different objective functions, which are initial construction cost and annual cost including electric cost. As results, it is calculated that the initial construction cost of 1,449,740 thousand won is saved and annual cost of 128,951 thousand won is saved for a year within study year. Also, the optimal site of pump station is selected on 5th pipe, which is located between the diverging junction to Kangdong(2) province and the diverging junction to Cheonbuk province. It is explained that pump cost is less than pipe cost in this application case study due to little pump station scale. In the case of water supply with large pump capacity, it is reasonal that the increase of pipe size is more efficient instead the increase of pump station capacity to save annual cost.

  • PDF

자연순환형 태양열 온수기 축열조의 압력식 설계 개조 (Design Modification of a Thermal Storage Tank of Natural-Circulation Solar Water Heater for a Pressurized System)

  • 부준홍;정의국
    • 한국태양에너지학회 논문집
    • /
    • 제27권3호
    • /
    • pp.45-54
    • /
    • 2007
  • For a conventional natural-circulation type solar water heater, the pressure head is limited by the height between the storage tank and hot water tap. Therefore, it is difficult to provide sufficient hot water flow rate for general usage. This study deals with a design modification of the storage tank to utilize the tap-water pressure to increase hot-water supply Based on fluid dynamic and heat transfer theories, a series of modeling and simulation is conducted to achieve practical design requirements. An experimental setup is built and tested and the results are compared with theoretical simulation model. The storage tank capacity is 240 l and the outer diameter of piping was 15 mm. Number of tube turns tested are 5, 10, and 15. Starting with initial storage tank temperature of $80^{\circ}C$, the temperature variation of the supply hot water is investigated against time, while maintaining minimum flow rate of 10 1/min. Typical results show that the hot water supply of minimum $30^{\circ}C$ can be maintained for 34 min with tap-water supply pressure of 2.5 atm, The relative errors between modeling and experiments coincide well within 10% in most cases.

현장조사 관개 기준에 따른 농업용 저수지 운영 분석 (Agricultural Reservoir Operation Analysis According to Surveyed Irrigation Guideline)

  • 김마가;최진용;방재홍;윤푸른;김귀훈
    • 한국농공학회논문집
    • /
    • 제65권5호
    • /
    • pp.37-49
    • /
    • 2023
  • The drought risk has been increasing recently due to climate change causing the extreme climate to be more frequent. In order to supply agricultural water stably under drought, it is necessary to operate an agricultural reservoir in response to drought. To this end, it is crucial to establish appropriate drought response operation rules considering weather conditions and reservoir status. In the reservoir operation simulation, the supply amount differs from the actual reservoir supply for many reasons, including maintaining water levels for supply and accommodating farmers' requests. So, for a more realistic reservoir operation simulation, it is necessary to reflect the reservoir operation rules of the actual water management site. Therefore, in this study, through a survey, the standards for limitation of agricultural water supply applied to agricultural reservoirs in Korea were investigated, and the criteria for drought response reservoir operation (DRO) were established based on the survey. Then, the DRO was applied to the irrigation period for nine subject reservoirs. The applicability was evaluated by comparing the DRO result to the operation result of HOMWRS (Hydrological Operation Model for Water Resources System). The reservoir drought index, storage rate, and daily supply were compared for evaluation. From the result, DRO showed more stable operation results in most cases against drought as it has fewer days of water supply limitation and a somewhat reservoir storage rate which can be utilized for prolonged drought.

발전용댐 이수능력 평가 연구 (III): 한강수계 발전용댐 가뭄단계별 운영기준 개발 및 효과 분석 (Evaluation of hydropower dam water supply capacity (III): development and application of drought operation rule for hydropower dams in Han river)

  • 정기문;강두선;김태순
    • 한국수자원학회논문집
    • /
    • 제55권7호
    • /
    • pp.531-543
    • /
    • 2022
  • 최근 국내에서는 수량, 수질 등 기후변화로 인한 다양한 수자원 문제에 효율적으로 대응하기 위한 통합물관리 체계가 점차 고도화되고 있으며, 특히 친환경적인 관점에서 이미 개발된 수자원시설물의 탄력적인 활용 방안이 주목받고 있다. 이처럼 용수를 사전에 확보하고, 적시에 공급하기 위한 대표적인 수자원 관리 시설로 다목적댐, 용수전용댐 등이 가장 잘 알려져 있으나, 지난 2021년 '한강수계 발전용댐 다목적 활용 협약'을 기점으로 발전용댐 또한 기존의 수력발전 용도를 넘어 수자원 관리 기여도가 한층 높아지게 되었다. 댐에서는 가뭄 발생시 구체적인 가뭄단계 파악 및 용수공급량 조절을 통해 용수공급을 조절해야 한다. 이미 다목적댐 및 용수전용댐의 경우 가뭄대응을 위한 용수공급 운영기준이 마련되어 적용 중에 있으나, 최근에 다목적 활용이 추진된 발전용댐의 경우 구체적인 관련 기준이 마련되어 있지 않은 실정이다. 본 연구에서는 기존 다목적댐 및 용수전용댐 운영기준을 참고하여, 발전용댐의 가뭄단계별 기준저수량 산정 방안 및 용수공급 조정 방안 등을 제시하였다. 제시된 방법은 국내 대부분의 발전용댐이 위치한 한강수계 발전용댐을 대상으로 적용하였으며, 지난 2014~2017년 발생한 가뭄사례를 바탕으로 그 적용 효과를 분석한 결과, 대상 발전용댐의 용수공급 안정성이 개선되는 효과를 확인하였다. 수자원의 효율적인 이용을 위한 발전용댐의 역할은 점차 중요해질 것으로 예상되며, 본 연구 결과는 발전용댐을 활용한 용수공급 관련 연구에 폭넓게 활용될 수 있을 것으로 기대된다.

간헐포기 활성슬러지 중수처리공정의 현장적용 연구 (A Study on the Field Application of Intermittently Aerated Activated Sludge Process for Water Reuse System)

  • 서인석;김병군;박승국;권선웅
    • 한국물환경학회지
    • /
    • 제16권4호
    • /
    • pp.513-521
    • /
    • 2000
  • Intermittently aerated activated sludge process was applied as a water reuse process of $70m^3/day$ for the upgrade of organic, nitrogen and phosphorus removal efficiency and clarifier performance. After application of the intermittently aeration, removal efficiency of BOD, SS, T-N and T-P were achieved 95%, 90%, 80% and 60%, respectively. Removal efficiencies in intermittently aerated process were considerably increased. comparing to those of continuously aerated activated sludge process. Also sludge rising problem in clarifier was improved. Average concentration of supplied reusing water were BOD 5 mg/L, turbidity 4 NTU and after chlorination, residual chlorine 0.4 mg/L, coliform 0 MPN/100mL. Intermittently aerated activated sludge process could be one of the best alternative process for the retrofit of conventional activated sludge process for the removal of nutrient in water reuse system.

  • PDF

SRI 물관리 방법이 논의 관개용수량과 비점오염원 저감에 미치는 영향 (Evaluation of SRI Water Management on the Reduction of Irrigation Supply and NPS Pollution in Paddies)

  • 서지연;박배경;박운지;윤광식;최동호;김용석;류지철;최중대
    • 한국물환경학회지
    • /
    • 제32권2호
    • /
    • pp.183-190
    • /
    • 2016
  • Monitored data (rainfall runoff and water quality) from 4 different paddy sites over 3 years were compared to analyze the effect of irrigation water management on irrigation supply and rainfall runoff quality in Korea. The system of rice intensification water management was adopted at one site (SRI) while the conventional water management method was used for rice culture at the other three sites (CT, SD and HD). The soil texture at SRI, CT and SD was sandy loam while that at HD was silt loam. The average reduction of irrigation supply at SRI compared with CT, SD and HD during the 3 years studied was 49%, 51% and 55%, respectively. The average event mean concentration (EMC) at SRI compared with that at CT, SD and HD was decreased by 35% (BOD), 44% (COD), 47% (SS), 19% (TN) and 38% (TP). The correlation between rainfall runoff and the measured non-point source (NPS) pollutants was very good in general. The comparison revealed that SRI water management significantly reduced both irrigation supply and EMC in rainfall runoff. Paddy NPS pollution was closely related to factors that induce runoff such as rainfall and irrigation supply. It was concluded that SRI management could be an effective and practical option to cope with both water shortage due to climate change and water quality improvement in rural watersheds. However, further studies are recommended in large irrigation districts for use in the development and implementation of NPS pollution policies since the data was collected from field sized paddies.